{ "_meta": { "built_by": "矿脉C 会话 2026-09-02 (subagent, repo-only)", "purpose": "把 param_dict 阈值与 status_codes 触发条件对接: 回答\"该阈值有没有真的接到一条码/该码在10min层可不可测/自动还是手动复位\"", "source": [ "status_codes.json", "param_dict.json" ], "method": "正则 PAR_[A-Za-z0-9_]+ 扫 trigger_en/trigger_cn/reset_en/reset_cn/set_delay/repeat_n/repeat_period/powerup_delay; 过程变量粒度取 trigger 里 gr* 后缀", "evidence_tier": { "A_cross_system": "RTW控制律与PLC PAR_ 两套独立体系给同一数值 (最强, 需人工标注, 见 cross_system_hits)", "B_golden_tuned": "golden_kk_2014_12 ≠ default = **字面不同(已撤回'=实调=真实机值'的解读, 见 param_dict.meta.SELF_CORRECTION)**; 差异更可能是跨18个月版本增量", "B_golden_only": "仅存在于 Golden 模板 (无 default 可比, 但属实调包)", "C_partial": "列间有差异但 golden==default", "D_template_default": "五列全同 = 模板从未被调过 = 最弱证据, 禁作独立锚", "X_param_not_in_dict": "码引用了字典里没有的 PAR (字典不全)" }, "counts": { "codes_total": 1295, "codes_with_par_ref": 211, "params_referenced": 215, "params_referenced_unknown": 36, "params_never_referenced": 701, "params_total": 880 }, "caveat": "SC-1=EN136 4MW海上鼠笼; 我方远景场多为1.5-2.2MW陆上DFIG。阈值数值禁直接外推(见 README 可迁性表), 本表用途是\"结构与接线\"而非\"数值\"", "provenance": { "kind": "OEM 调试包解析产物 (生成器/模板层), **非整机回读**", "evidence_grade": "**模板值** — 按三级标签(实机回读/模板值·生效/模板值·空置), 本包**无一条够得上'实机回读'**", "not": "不是任何一台机的实际设定; '一致/闭环/自洽'指模板与模板 或 模板与实测数据 之间的一致, **不代表某台机的实际值**", "usage": "证据强度=模板值 × 用途: 作**分组依据/设计意图**合格; 作**阈值锚不合格**", "see": "README '证据规矩' 节 + param_dict.json meta.SELF_CORRECTION_2026_09_02", "stamped": "2026-09-02 结构污染审计补标" } }, "param_code_xref": { "PAR_UnfilHydraulicLoad": { "codes": [ "02_09_024" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_WCSInletPreHigh1": { "codes": [ "02_08_123", "02_08_126", "03_05_048", "03_05_051" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_WCSInletPreHigh2": { "codes": [ "02_08_122", "02_08_125", "03_05_047", "03_05_049", "03_05_058" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_WCSInletPreLow1": { "codes": [ "02_08_127", "03_05_052" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_WCSInletPreLow2": { "codes": [ "02_08_128", "03_05_053" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_WCSInletTempLow": { "codes": [ "02_08_131", "03_05_056" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_WCSOutletPreLow1": { "codes": [ "02_08_129", "03_05_054" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_WCSOutletPreLow2": { "codes": [ "02_08_130", "03_05_055" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_YawMotorProtectionReverse": { "codes": [ "02_02_046" ], "in_param_dict": true, "cn": "偏航电机热保护触发电平", "unit": "", "subsystem": "YawSystem", "values": { "default": "FALSE", "value_sc1_4mw": "0", "value_sc1_4mw_b": "False", "golden_kk_2014_12": "0", "value_xuyi_legacy_other_model": "1" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_bActivatePitchAndTorqueExternal": { "codes": [ "03_06_032" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_bAsymControlEn": { "codes": [ "01_05_072", "01_05_073" ], "in_param_dict": true, "cn": "不对称变桨功能使能", "unit": "1", "subsystem": "CoreController", "values": { "default": "FALSE", "value_sc1_4mw": "0", "value_sc1_4mw_b": "0", "golden_kk_2014_12": "0", "value_xuyi_legacy_other_model": "0" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_bAutoGreaseEnable": { "codes": [ "02_10_109" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_bAutoGreaseError": { "codes": [ "02_10_106", "02_10_110" ], "in_param_dict": true, "cn": "偏航自润滑报警电位", "unit": "", "subsystem": "YawSystem", "values": { "default": "FALSE", "value_sc1_4mw": "False", "value_sc1_4mw_b": "False", "golden_kk_2014_12": "1", "value_xuyi_legacy_other_model": "1" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_bTowerDoorSwitchSignal": { "codes": [ "03_07_010" ], "in_param_dict": true, "cn": "是否有塔筒门信号监测", "unit": "1", "subsystem": "Cabinet", "values": { "default": "False", "value_sc1_4mw": "False", "value_sc1_4mw_b": "False", "golden_kk_2014_12": "0", "value_xuyi_legacy_other_model": "0" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_bTowerResonanceMode": { "codes": [ "03_09_114" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_bUPSAlarmSignal": { "codes": [ "03_02_002" ], "in_param_dict": true, "cn": "GEN系列变频器UPS报警信号电平", "unit": "1", "subsystem": "Cabinet", "values": { "default": "False", "value_sc1_4mw": "False", "value_sc1_4mw_b": "False", "golden_kk_2014_12": "1", "value_xuyi_legacy_other_model": "1" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_iMaxNumberOfTraceLogs": { "codes": [ "03_06_020" ], "in_param_dict": true, "cn": "Tracelog存储个数限制", "unit": "", "subsystem": "LogSystem", "values": { "default": "1000", "value_sc1_4mw": "1000", "value_sc1_4mw_b": "1000", "golden_kk_2014_12": "1000", "value_xuyi_legacy_other_model": "1000" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_iNumberMaxPitchComError": { "codes": [ "04_02_036" ], "in_param_dict": true, "cn": "变桨通讯报警频繁次数上限", "unit": "", "subsystem": "Pitchsystem", "values": { "default": "3", "value_sc1_4mw": "3", "value_sc1_4mw_b": "3", "golden_kk_2014_12": "3", "value_xuyi_legacy_other_model": "" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_iNumberMaxStartHydPump": { "codes": [ "02_09_021" ], "in_param_dict": true, "cn": "液压泵开启频繁次数上限", "unit": "", "subsystem": "HSBrakeSystem", "values": { "default": "10", "value_sc1_4mw": "10", "value_sc1_4mw_b": "10", "golden_kk_2014_12": "10", "value_xuyi_legacy_other_model": "10" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rAccelLimit1ForeaftDirection": { "codes": [ "02_04_021" ], "in_param_dict": true, "cn": "前后方向震动阈值Level1", "unit": "无", "subsystem": "NacelleSystem", "values": { "default": "1", "value_sc1_4mw": "1", "value_sc1_4mw_b": "1", "golden_kk_2014_12": "1", "value_xuyi_legacy_other_model": "1" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rAccelLimit1OmniDirection": { "codes": [ "02_04_018", "02_04_019" ], "in_param_dict": true, "cn": "左右方向震动阈值Level1", "unit": "无", "subsystem": "NacelleSystem", "values": { "default": "1.2", "value_sc1_4mw": "1.2", "value_sc1_4mw_b": "1.2", "golden_kk_2014_12": "1.2", "value_xuyi_legacy_other_model": "1.2" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rAccelLimit2ForeaftDirection": { "codes": [ "02_04_022" ], "in_param_dict": true, "cn": "前后方向震动阈值Level2", "unit": "无", "subsystem": "NacelleSystem", "values": { "default": "1.2", "value_sc1_4mw": "1.2", "value_sc1_4mw_b": "1.2", "golden_kk_2014_12": "1.2", "value_xuyi_legacy_other_model": "1.2" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rBladeZeroPositionInsideOffsetAlarm": { "codes": [ "04_02_140", "04_02_141", "04_02_142" ], "in_param_dict": true, "cn": "零位传感器范围向内侧偏移故障值", "unit": "°", "subsystem": "Pitchsystem", "values": { "default": "1", "value_sc1_4mw": "", "value_sc1_4mw_b": "1", "golden_kk_2014_12": "1", "value_xuyi_legacy_other_model": "" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rBladeZeroPositionOutsideOffsetAlarm": { "codes": [ "04_02_140", "04_02_141", "04_02_142" ], "in_param_dict": true, "cn": "零位传感器范围向外侧偏移故障值", "unit": "°", "subsystem": "Pitchsystem", "values": { "default": "1", "value_sc1_4mw": "", "value_sc1_4mw_b": "1", "golden_kk_2014_12": "1", "value_xuyi_legacy_other_model": "" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rCVT_IGBT_TempHigh": { "codes": [ "04_12_023" ], "in_param_dict": true, "cn": "IGBT温度高(不停机)", "unit": "摄氏度", "subsystem": "ConverterContainer", "values": { "default": "120", "value_sc1_4mw": "", "value_sc1_4mw_b": "120", "golden_kk_2014_12": "120", "value_xuyi_legacy_other_model": "" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rCVT_IGBT_TempVeryHigh": { "codes": [ "04_12_024" ], "in_param_dict": true, "cn": "IGBT温度太高(太高)", "unit": "摄氏度", "subsystem": "ConverterContainer", "values": { "default": "130", "value_sc1_4mw": "", "value_sc1_4mw_b": "130", "golden_kk_2014_12": "130", "value_xuyi_legacy_other_model": "" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rCVT_IGBT_TempVeryHighOR": { "codes": [ "04_12_024" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rDiffForSetValuePitchReached": { "codes": [ "03_06_135", "03_09_011" ], "in_param_dict": true, "cn": "桨角控制到位偏差容忍值", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "0.2", "value_sc1_4mw": "0.2", "value_sc1_4mw_b": "0.2", "golden_kk_2014_12": "0.2", "value_xuyi_legacy_other_model": "0.2" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rEndpositionPitchZeroDegrees": { "codes": [ "03_09_110" ], "in_param_dict": true, "cn": "风机finepitch角度", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "-0.25", "value_sc1_4mw": "0", "value_sc1_4mw_b": "0", "golden_kk_2014_12": "-5", "value_xuyi_legacy_other_model": "-0.4" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rGearOilPressure_MAX": { "codes": [ "02_05_008" ], "in_param_dict": true, "cn": "齿轮箱压力报警上限", "unit": "", "subsystem": "Gearbox", "values": { "default": "20", "value_sc1_4mw": "12", "value_sc1_4mw_b": "12", "golden_kk_2014_12": "10", "value_xuyi_legacy_other_model": "16" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rGearboxRatio": { "codes": [ "02_04_001", "02_04_009", "02_04_010" ], "in_param_dict": true, "cn": "齿轮箱变比", "unit": "", "subsystem": "Gearbox", "values": { "default": "119.752", "value_sc1_4mw": "119.752", "value_sc1_4mw_b": "119.752", "golden_kk_2014_12": "119.752", "value_xuyi_legacy_other_model": "106" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rGenOverSpeedLevel1": { "codes": [ "02_04_001", "02_04_003" ], "in_param_dict": true, "cn": "发电机一级过速阈值", "unit": "", "subsystem": "Drivetrain", "values": { "default": "1705", "value_sc1_4mw": "1705", "value_sc1_4mw_b": "1705", "golden_kk_2014_12": "1705", "value_xuyi_legacy_other_model": "1980" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rGenOverSpeedLevel2": { "codes": [ "02_04_004" ], "in_param_dict": true, "cn": "发电机2级过速阈值", "unit": "rpm", "subsystem": "SafetySystem", "values": { "default": "1860", "value_sc1_4mw": "1860", "value_sc1_4mw_b": "1860", "golden_kk_2014_12": "1860", "value_xuyi_legacy_other_model": "2250" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rGenSpeedDiffCompareRotGen_RPM": { "codes": [ "02_04_006", "02_04_039" ], "in_param_dict": true, "cn": "低速端高低速偏差最大差异阈值", "unit": "", "subsystem": "Drivetrain", "values": { "default": "20", "value_sc1_4mw": "20", "value_sc1_4mw_b": "20", "golden_kk_2014_12": "20", "value_xuyi_legacy_other_model": "20" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rGenSpeedDiffCompareRotGen_RPM_HIGH": { "codes": [ "02_04_006", "02_04_039" ], "in_param_dict": true, "cn": "高速端高低速偏差最大差异阈值", "unit": "", "subsystem": "Drivetrain", "values": { "default": "15", "value_sc1_4mw": "15", "value_sc1_4mw_b": "15", "golden_kk_2014_12": "15", "value_xuyi_legacy_other_model": "15" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rGenSpeedLimitToAutoGrease": { "codes": [ "02_10_109" ], "in_param_dict": true, "cn": "允许偏航自润滑最高发电机转速", "unit": "", "subsystem": "YawSystem", "values": { "default": "200", "value_sc1_4mw": "200", "value_sc1_4mw_b": "200", "golden_kk_2014_12": "200", "value_xuyi_legacy_other_model": "200" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rGenSpeedSetValueBrakeModeVanePos": { "codes": [ "03_06_135" ], "in_param_dict": true, "cn": "刹车时最高发电机转速", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "500", "value_sc1_4mw": "500", "value_sc1_4mw_b": "500", "golden_kk_2014_12": "500", "value_xuyi_legacy_other_model": "500" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rGenSpeedSetValueBrakeModeVanePos_x000D_": { "codes": [ "03_09_011", "03_09_012" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rGenSpeedSlipLimit_MIN": { "codes": [ "02_04_102", "02_08_001", "02_08_002" ], "in_param_dict": true, "cn": "正常运行时发电机最小转速,低于此转速进入Trundle模式", "unit": "", "subsystem": "Drivetrain", "values": { "default": "1065", "value_sc1_4mw": "450", "value_sc1_4mw_b": "450", "golden_kk_2014_12": "720", "value_xuyi_legacy_other_model": "1065" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rGenSpeedStartCompareRotGen": { "codes": [ "02_04_006", "02_04_009", "02_04_010", "02_04_039" ], "in_param_dict": true, "cn": "开始监测速度不匹配故障发电机转速", "unit": "", "subsystem": "Drivetrain", "values": { "default": "350", "value_sc1_4mw": "350", "value_sc1_4mw_b": "350", "golden_kk_2014_12": "350", "value_xuyi_legacy_other_model": "350" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rGenSpeedStartDetectDirection": { "codes": [ "02_04_007" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rGenSpeedStopDetectDirection": { "codes": [ "02_04_007" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rGenSpeedUnequalDefectingHighSpeed": { "codes": [ "02_04_006", "02_04_039" ], "in_param_dict": true, "cn": "高低速偏差检测分界线", "unit": "", "subsystem": "Drivetrain", "values": { "default": "700", "value_sc1_4mw": "700", "value_sc1_4mw_b": "700", "golden_kk_2014_12": "700", "value_xuyi_legacy_other_model": "700" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rGridFrequencyMAX_Hz": { "codes": [ "03_04_010", "03_04_020" ], "in_param_dict": true, "cn": "电网频率过高Level2", "unit": "Hz", "subsystem": "GridMeasurement", "values": { "default": "52", "value_sc1_4mw": "51", "value_sc1_4mw_b": "51", "golden_kk_2014_12": "51.5", "value_xuyi_legacy_other_model": "51" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rGridFrequencyMIN_Hz": { "codes": [ "03_04_011", "03_04_021" ], "in_param_dict": true, "cn": "电网频率过低Level2", "unit": "Hz", "subsystem": "GridMeasurement", "values": { "default": "47.5", "value_sc1_4mw": "48.5", "value_sc1_4mw_b": "48.5", "golden_kk_2014_12": "47.5", "value_xuyi_legacy_other_model": "48" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rGridVoltageMAX_percent": { "codes": [ "03_04_002", "03_04_003", "03_04_004" ], "in_param_dict": true, "cn": "电网电压过高百分比", "unit": "无", "subsystem": "GridMeasurement", "values": { "default": "10", "value_sc1_4mw": "10", "value_sc1_4mw_b": "10", "golden_kk_2014_12": "10", "value_xuyi_legacy_other_model": "10" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rGridVoltageMIN_percent": { "codes": [ "03_04_006", "03_04_007", "03_04_008" ], "in_param_dict": true, "cn": "电网电压过低百分比", "unit": "无", "subsystem": "GridMeasurement", "values": { "default": "10", "value_sc1_4mw": "10", "value_sc1_4mw_b": "10", "golden_kk_2014_12": "11", "value_xuyi_legacy_other_model": "10" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rHVRTVolLevel0Multiplier": { "codes": [ "03_04_022" ], "in_param_dict": true, "cn": "高电压穿越Level1", "unit": "", "subsystem": "GridMeasurement", "values": { "default": "1.1", "value_sc1_4mw": "1.1", "value_sc1_4mw_b": "1.1", "golden_kk_2014_12": "1.11", "value_xuyi_legacy_other_model": "1.1" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rHydSystemPressMAX_STOP": { "codes": [ "02_09_005" ], "in_param_dict": true, "cn": "预充压力报警上限", "unit": "", "subsystem": "HSBrakeSystem", "values": { "default": "65", "value_sc1_4mw": "250", "value_sc1_4mw_b": "250", "golden_kk_2014_12": "210", "value_xuyi_legacy_other_model": "100" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rHydSystemPressMIN_STOP": { "codes": [ "02_09_003" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rHydSystemPressMIN_Warn": { "codes": [ "02_09_001" ], "in_param_dict": true, "cn": "预充压力警告下限", "unit": "", "subsystem": "HSBrakeSystem", "values": { "default": "50", "value_sc1_4mw": "80", "value_sc1_4mw_b": "80", "golden_kk_2014_12": "50", "value_xuyi_legacy_other_model": "50" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rHydSystemPressMainCircuitMIN_STOP": { "codes": [ "02_09_007" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rHydSystemPressMainCircuitMIN_Warn": { "codes": [ "02_09_006" ], "in_param_dict": true, "cn": "主回路压力报警下限", "unit": "", "subsystem": "HSBrakeSystem", "values": { "default": "140", "value_sc1_4mw": "140", "value_sc1_4mw_b": "140", "golden_kk_2014_12": "0", "value_xuyi_legacy_other_model": "140" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxCurrentDiff_A": { "codes": [ "03_04_200" ], "in_param_dict": true, "cn": "三相电流最大差异", "unit": "A", "subsystem": "GridMeasurement", "values": { "default": "200", "value_sc1_4mw": "200", "value_sc1_4mw_b": "200", "golden_kk_2014_12": "300", "value_xuyi_legacy_other_model": "200" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxDeviation_WindDirection": { "codes": [ "04_09_008" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rMaxDeviation_WindSpeed": { "codes": [ "04_09_009" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rMaxDiffSensorsBladeAngle_PitchLimit1": { "codes": [ "01_05_072", "01_05_073" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rMaxDiffSensorsBladeAngle_PitchLimit2": { "codes": [ "01_05_073" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rMaxDiffSensorsBladeAngle_PitchLimit5": { "codes": [ "01_05_001", "01_05_021", "01_05_041" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rMaxGenSpeedAtManualOperation": { "codes": [ "03_09_009" ], "in_param_dict": true, "cn": "风机在维护模式最高发电机转速设定", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "1500", "value_sc1_4mw": "1500", "value_sc1_4mw_b": "1500", "golden_kk_2014_12": "800", "value_xuyi_legacy_other_model": "1500" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxPower10min": { "codes": [ "02_08_001" ], "in_param_dict": true, "cn": "10min平均功率最大值", "unit": "KW", "subsystem": "GridMeasurement", "values": { "default": "4000", "value_sc1_4mw": "4050", "value_sc1_4mw_b": "4050", "golden_kk_2014_12": "4300", "value_xuyi_legacy_other_model": "1600" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxPower1sec": { "codes": [ "02_08_003" ], "in_param_dict": true, "cn": "1sec平均功率最大值", "unit": "KW", "subsystem": "GridMeasurement", "values": { "default": "4000", "value_sc1_4mw": "4600", "value_sc1_4mw_b": "4600", "golden_kk_2014_12": "4850", "value_xuyi_legacy_other_model": "1780" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxPower30sec": { "codes": [ "02_08_002" ], "in_param_dict": true, "cn": "30sec平均功率最大值", "unit": "KW", "subsystem": "GridMeasurement", "values": { "default": "4000", "value_sc1_4mw": "4400", "value_sc1_4mw_b": "4400", "golden_kk_2014_12": "4650", "value_xuyi_legacy_other_model": "1600" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxPowerDiff100ms": { "codes": [ "02_08_009" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rMaxPowerDiff100ms_x000D_": { "codes": [ "02_08_009" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rMaxRecoverWindSpeed_10min": { "codes": [ "02_11_103" ], "in_param_dict": true, "cn": "10分钟风速过大停机状态字消失的10分钟平均风速阈值", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "20", "value_sc1_4mw": "22", "value_sc1_4mw_b": "22", "golden_kk_2014_12": "22", "value_xuyi_legacy_other_model": "18" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxRecoverWindSpeed_1sec": { "codes": [ "02_11_101" ], "in_param_dict": true, "cn": "1秒钟风速过大停机状态字消失的1秒钟平均风速阈值", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "25", "value_sc1_4mw": "16", "value_sc1_4mw_b": "16", "golden_kk_2014_12": "16", "value_xuyi_legacy_other_model": "15" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxRecoverWindSpeed_30sec": { "codes": [ "02_11_102" ], "in_param_dict": true, "cn": "30秒风速过大停机状态字消失的30秒平均风速阈值", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "23", "value_sc1_4mw": "19", "value_sc1_4mw_b": "19", "golden_kk_2014_12": "19", "value_xuyi_legacy_other_model": "17" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxWindForManualModeOrService": { "codes": [ "02_11_113" ], "in_param_dict": true, "cn": "运行进入手动模式、维护模式的最大风速", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "15", "value_sc1_4mw": "12", "value_sc1_4mw_b": "12", "golden_kk_2014_12": "12", "value_xuyi_legacy_other_model": "12" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxWindSpeed_10min": { "codes": [ "02_11_103" ], "in_param_dict": true, "cn": "10分钟风速过大停机状态字触发的10分钟平均风速阈值", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "25", "value_sc1_4mw": "24", "value_sc1_4mw_b": "24", "golden_kk_2014_12": "24", "value_xuyi_legacy_other_model": "20" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxWindSpeed_1sec": { "codes": [ "02_11_101" ], "in_param_dict": true, "cn": "1秒钟风速过大停机状态字触发的1秒钟平均风速阈值", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "30", "value_sc1_4mw": "30", "value_sc1_4mw_b": "30", "golden_kk_2014_12": "30", "value_xuyi_legacy_other_model": "25" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rMaxWindSpeed_30sec": { "codes": [ "02_11_102" ], "in_param_dict": true, "cn": "30秒风速过大停机状态字触发的30秒平均风速阈值", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "28", "value_sc1_4mw": "27", "value_sc1_4mw_b": "27", "golden_kk_2014_12": "27", "value_xuyi_legacy_other_model": "23" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMaxWindUntwistCable": { "codes": [ "02_11_112" ], "in_param_dict": true, "cn": "允许偏航解缆最高风速", "unit": "", "subsystem": "YawSystem", "values": { "default": "34", "value_sc1_4mw": "25", "value_sc1_4mw_b": "25", "golden_kk_2014_12": "25", "value_xuyi_legacy_other_model": "25" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rMinRecoverWindSpeed_10min": { "codes": [ "02_11_109" ], "in_param_dict": true, "cn": "10分钟平均风速过小状态字消失的10分钟平均风速阈值", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "3.8", "value_sc1_4mw": "3.8", "value_sc1_4mw_b": "3.8", "golden_kk_2014_12": "3.8", "value_xuyi_legacy_other_model": "3.2" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rMinWindSpeed_10min": { "codes": [ "02_11_109" ], "in_param_dict": true, "cn": "10分钟平均风速过小状态字触发的10分钟平均风速阈值", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "2.8", "value_sc1_4mw": "3.3", "value_sc1_4mw_b": "3.3", "golden_kk_2014_12": "3.3", "value_xuyi_legacy_other_model": "2.9000001" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rNominalVoltage_Level_690V": { "codes": [ "03_04_002", "03_04_003", "03_04_004", "03_04_006", "03_04_007", "03_04_008", "03_04_022" ], "in_param_dict": true, "cn": "额定电网电压", "unit": "V", "subsystem": "GridMeasurement", "values": { "default": "690", "value_sc1_4mw": "690", "value_sc1_4mw_b": "690", "golden_kk_2014_12": "690", "value_xuyi_legacy_other_model": "690" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rPitchAngleSetValueVanePosition": { "codes": [ "01_05_072", "01_05_073", "03_06_135", "03_09_011" ], "in_param_dict": true, "cn": "风机Vane桨叶角度设定", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "89", "value_sc1_4mw": "89", "value_sc1_4mw_b": "89", "golden_kk_2014_12": "89", "value_xuyi_legacy_other_model": "89" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rPitchMoveLimit": { "codes": [ "03_09_110" ], "in_param_dict": true, "cn": "进入桨叶自润滑,桨叶角度范围", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "15", "value_sc1_4mw": "15", "value_sc1_4mw_b": "15", "golden_kk_2014_12": "6", "value_xuyi_legacy_other_model": "15" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rPower100msDiffMax": { "codes": [ "02_08_009" ], "in_param_dict": true, "cn": "外部设备、变频器测得功率允许的最大差异", "unit": "KW", "subsystem": "GridMeasurement", "values": { "default": "150", "value_sc1_4mw": "150", "value_sc1_4mw_b": "150", "golden_kk_2014_12": "350", "value_xuyi_legacy_other_model": "150" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rPowerAboveUntwistCablePreSTOP": { "codes": [ "02_10_102" ], "in_param_dict": true, "cn": "允许偏航预解缆的最高发电机功率", "unit": "", "subsystem": "YawSystem", "values": { "default": "400", "value_sc1_4mw": "400", "value_sc1_4mw_b": "400", "golden_kk_2014_12": "400", "value_xuyi_legacy_other_model": "400" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rPre_CS_LowError": { "codes": [ "04_08_015" ], "in_param_dict": true, "cn": "冷却系统压力过低故障", "unit": "Bar", "subsystem": "CoolingSystem", "values": { "default": "0.1", "value_sc1_4mw": "0.1", "value_sc1_4mw_b": "0.1", "golden_kk_2014_12": "0.2", "value_xuyi_legacy_other_model": "0.1" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rPre_CS_LowWarning": { "codes": [ "04_08_014" ], "in_param_dict": true, "cn": "冷却系统压力过低报警", "unit": "Bar", "subsystem": "CoolingSystem", "values": { "default": "1", "value_sc1_4mw": "1", "value_sc1_4mw_b": "1", "golden_kk_2014_12": "0.4", "value_xuyi_legacy_other_model": "1" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rPressHysteresisLower": { "codes": [ "02_09_020" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rPressHysteresisUpper": { "codes": [ "02_09_019" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rPressToReleaseYawMotor_MAX": { "codes": [ "02_09_020" ], "in_param_dict": true, "cn": "偏航动作期间主回路压力", "unit": "", "subsystem": "YawSystem", "values": { "default": "20", "value_sc1_4mw": "20", "value_sc1_4mw_b": "20", "golden_kk_2014_12": "17", "value_xuyi_legacy_other_model": "20" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rPressToReleaseYawMotor_MIN": { "codes": [ "02_09_019" ], "in_param_dict": true, "cn": "泄压动作最高主回路压力", "unit": "", "subsystem": "YawSystem", "values": { "default": "0", "value_sc1_4mw": "0", "value_sc1_4mw_b": "0", "golden_kk_2014_12": "0", "value_xuyi_legacy_other_model": "0" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rRotorLockPushOutPressureLowError": { "codes": [ "04_03_006" ], "in_param_dict": true, "cn": "风轮锁销子退出压力过低故障阈值", "unit": "Bar", "subsystem": "RotorLock", "values": { "default": "5", "value_sc1_4mw": "5", "value_sc1_4mw_b": "5", "golden_kk_2014_12": "5", "value_xuyi_legacy_other_model": "5" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rRotorLockPushOutPressureLowWarning": { "codes": [ "04_03_005" ], "in_param_dict": true, "cn": "风轮锁销子退出压力过低警告阈值", "unit": "Bar", "subsystem": "RotorLock", "values": { "default": "20", "value_sc1_4mw": "20", "value_sc1_4mw_b": "20", "golden_kk_2014_12": "20", "value_xuyi_legacy_other_model": "20" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rRotorLockPushOutPressureOK": { "codes": [ "04_03_003" ], "in_param_dict": true, "cn": "风轮锁销子退出压力正常", "unit": "Bar", "subsystem": "RotorLock", "values": { "default": "80", "value_sc1_4mw": "150", "value_sc1_4mw_b": "150", "golden_kk_2014_12": "150", "value_xuyi_legacy_other_model": "80" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rSSDMax": { "codes": [ "02_01_006", "04_01_017" ], "in_param_dict": true, "cn": "检测SSD震动的阈值", "unit": "无", "subsystem": "NacelleSystem", "values": { "default": "5", "value_sc1_4mw": "5", "value_sc1_4mw_b": "5", "golden_kk_2014_12": "7", "value_xuyi_legacy_other_model": "5" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rShutDownSlowForLowPower": { "codes": [ "03_09_101", "03_09_102" ], "in_param_dict": true, "cn": "功率过低停机10min平均功率阈值", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "5", "value_sc1_4mw": "5", "value_sc1_4mw_b": "5", "golden_kk_2014_12": "5", "value_xuyi_legacy_other_model": "5" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempGearOilBelowMonitoringFilter": { "codes": [ "02_05_001" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rTempGen_HeaterON": { "codes": [ "02_08_100" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rTempHigh_CabinetNacelle": { "codes": [ "02_02_009", "02_02_010" ], "in_param_dict": true, "cn": "机舱控制柜高温报警阈值", "unit": "℃", "subsystem": "Cabinet", "values": { "default": "50", "value_sc1_4mw": "40", "value_sc1_4mw_b": "40", "golden_kk_2014_12": "40", "value_xuyi_legacy_other_model": "50" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempHigh_CabinetTower": { "codes": [ "03_02_024" ], "in_param_dict": true, "cn": "塔底控制柜高温报警阈值", "unit": "℃", "subsystem": "Cabinet", "values": { "default": "50", "value_sc1_4mw": "40", "value_sc1_4mw_b": "40", "golden_kk_2014_12": "40", "value_xuyi_legacy_other_model": "50" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempHigh_GearBearingDE": { "codes": [ "02_05_028" ], "in_param_dict": true, "cn": "齿轮箱驱动端温度高", "unit": "", "subsystem": "Gearbox", "values": { "default": "85", "value_sc1_4mw": "85", "value_sc1_4mw_b": "85", "golden_kk_2014_12": "90", "value_xuyi_legacy_other_model": "85" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempHigh_GearBearingNDE": { "codes": [ "02_05_033", "02_05_035" ], "in_param_dict": true, "cn": "齿轮箱非驱动端温度高", "unit": "", "subsystem": "Gearbox", "values": { "default": "85", "value_sc1_4mw": "85", "value_sc1_4mw_b": "85", "golden_kk_2014_12": "85", "value_xuyi_legacy_other_model": "85" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempHigh_GearOilInlet": { "codes": [ "02_05_019" ], "in_param_dict": true, "cn": "齿轮箱入口温度高", "unit": "", "subsystem": "Gearbox", "values": { "default": "70", "value_sc1_4mw": "70", "value_sc1_4mw_b": "70", "golden_kk_2014_12": "70", "value_xuyi_legacy_other_model": "0" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rTempHigh_GearOilSump": { "codes": [ "02_05_015", "02_05_017" ], "in_param_dict": true, "cn": "齿轮箱油池温度高", "unit": "", "subsystem": "Gearbox", "values": { "default": "70", "value_sc1_4mw": "70", "value_sc1_4mw_b": "70", "golden_kk_2014_12": "70", "value_xuyi_legacy_other_model": "70" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempHigh_GenBearDE": { "codes": [ "02_08_026", "02_08_030" ], "in_param_dict": true, "cn": "发电机驱动端温度高", "unit": "", "subsystem": "Generator", "values": { "default": "85", "value_sc1_4mw": "85", "value_sc1_4mw_b": "85", "golden_kk_2014_12": "95", "value_xuyi_legacy_other_model": "85" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempHigh_GenBearNDE": { "codes": [ "02_08_030" ], "in_param_dict": true, "cn": "发电机非驱动端温度高", "unit": "", "subsystem": "Generator", "values": { "default": "85", "value_sc1_4mw": "75", "value_sc1_4mw_b": "75", "golden_kk_2014_12": "95", "value_xuyi_legacy_other_model": "85" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempHigh_GenCoolingInlet": { "codes": [ "02_08_035" ], "in_param_dict": true, "cn": "发电机冷却入口温度高", "unit": "", "subsystem": "Generator", "values": { "default": "90", "value_sc1_4mw": "90", "value_sc1_4mw_b": "90", "golden_kk_2014_12": "90", "value_xuyi_legacy_other_model": "90" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempHigh_GenCoolingOutlet": { "codes": [ "02_08_035" ], "in_param_dict": true, "cn": "发电机冷却出口温度高", "unit": "", "subsystem": "Generator", "values": { "default": "125", "value_sc1_4mw": "125", "value_sc1_4mw_b": "125", "golden_kk_2014_12": "125", "value_xuyi_legacy_other_model": "125" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempHigh_GenStator": { "codes": [ "02_08_013", "02_08_017", "02_08_021" ], "in_param_dict": true, "cn": "发电机定子温度高", "unit": "", "subsystem": "Generator", "values": { "default": "130", "value_sc1_4mw": "150", "value_sc1_4mw_b": "150", "golden_kk_2014_12": "145", "value_xuyi_legacy_other_model": "130" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempHigh_Nacelle": { "codes": [ "02_03_001" ], "in_param_dict": true, "cn": "机舱温度过高阈值1", "unit": "℃", "subsystem": "NacelleSystem", "values": { "default": "40", "value_sc1_4mw": "45", "value_sc1_4mw_b": "45", "golden_kk_2014_12": "47", "value_xuyi_legacy_other_model": "45" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempHigh_Outdoor": { "codes": [ "02_11_016" ], "in_param_dict": true, "cn": "舱外温度过高阈值1", "unit": "℃", "subsystem": "NacelleSystem", "values": { "default": "35", "value_sc1_4mw": "35", "value_sc1_4mw_b": "35", "golden_kk_2014_12": "35", "value_xuyi_legacy_other_model": "35" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempHigh_RotorBearingA": { "codes": [ "02_04_026" ], "in_param_dict": true, "cn": "主轴轴承温度过高警告", "unit": "℃", "subsystem": "Drivetrain", "values": { "default": "55", "value_sc1_4mw": "60", "value_sc1_4mw_b": "60", "golden_kk_2014_12": "60", "value_xuyi_legacy_other_model": "55" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempHigh_TowerBase": { "codes": [ "03_03_001" ], "in_param_dict": true, "cn": "塔底高温报警阈值(sc-1在变频器集装箱)", "unit": "℃", "subsystem": "Cabinet", "values": { "default": "400", "value_sc1_4mw": "40", "value_sc1_4mw_b": "40", "golden_kk_2014_12": "40", "value_xuyi_legacy_other_model": "40" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempHysteresisGenStatorDew": { "codes": [ "02_08_100" ], "in_param_dict": true, "cn": "机舱与发电机定子温差上限", "unit": "", "subsystem": "Generator", "values": { "default": "5", "value_sc1_4mw": "5", "value_sc1_4mw_b": "5", "golden_kk_2014_12": "10", "value_xuyi_legacy_other_model": "2" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempHysteresisLowerTemp": { "codes": [ "02_03_002", "02_03_004", "02_05_016", "02_05_018", "02_05_020", "02_05_022", "02_05_033", "02_08_014", "02_08_016", "02_08_018", "02_08_020", "02_08_022", "02_08_024", "02_08_027", "02_08_029", "02_08_031", "02_08_033", "02_08_036", "02_08_038", "02_11_017", "02_11_019", "03_02_025", "03_02_027", "03_03_002", "03_03_004" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rTempHysteresisUpperTemp": { "codes": [ "02_02_009", "02_02_010", "02_02_011", "02_02_012", "02_03_001", "02_03_003", "02_04_026", "02_04_028", "02_05_015", "02_05_017", "02_05_019", "02_05_021", "02_05_028", "02_05_030", "02_05_035", "02_08_013", "02_08_015", "02_08_017", "02_08_019", "02_08_021", "02_08_023", "02_08_026", "02_08_028", "02_08_030", "02_08_032", "02_08_035", "02_08_037", "02_11_016", "02_11_018", "03_02_024", "03_02_026", "03_03_001", "03_03_003" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rTempLow_CabinetTower": { "codes": [ "03_02_025" ], "in_param_dict": true, "cn": "塔底控制柜低温报警阈值", "unit": "℃", "subsystem": "Cabinet", "values": { "default": "2", "value_sc1_4mw": "0", "value_sc1_4mw_b": "0", "golden_kk_2014_12": "0", "value_xuyi_legacy_other_model": "0" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempLow_GearBearingNDE": { "codes": [ "02_05_033" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rTempLow_GearOilInlet": { "codes": [ "02_05_020" ], "in_param_dict": true, "cn": "齿轮箱入口温度低", "unit": "", "subsystem": "Gearbox", "values": { "default": "5", "value_sc1_4mw": "5", "value_sc1_4mw_b": "5", "golden_kk_2014_12": "-20", "value_xuyi_legacy_other_model": "0" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempLow_GearOilSump": { "codes": [ "02_05_016" ], "in_param_dict": true, "cn": "齿轮箱油池温度低", "unit": "", "subsystem": "Gearbox", "values": { "default": "5", "value_sc1_4mw": "5", "value_sc1_4mw_b": "5", "golden_kk_2014_12": "0", "value_xuyi_legacy_other_model": "0" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempLow_GenBearDE": { "codes": [ "02_08_027" ], "in_param_dict": true, "cn": "发电机驱动端温度低", "unit": "", "subsystem": "Generator", "values": { "default": "-25", "value_sc1_4mw": "-20", "value_sc1_4mw_b": "-20", "golden_kk_2014_12": "-15", "value_xuyi_legacy_other_model": "-25" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempLow_GenBearNDE": { "codes": [ "02_08_031" ], "in_param_dict": true, "cn": "发电机非驱动端温度低", "unit": "", "subsystem": "Generator", "values": { "default": "-25", "value_sc1_4mw": "-20", "value_sc1_4mw_b": "-20", "golden_kk_2014_12": "-15", "value_xuyi_legacy_other_model": "-25" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempLow_GenCoolingInlet": { "codes": [ "02_08_036" ], "in_param_dict": true, "cn": "发电机冷却入口温度低", "unit": "", "subsystem": "Generator", "values": { "default": "-222", "value_sc1_4mw": "-222", "value_sc1_4mw_b": "-222", "golden_kk_2014_12": "-222", "value_xuyi_legacy_other_model": "-273" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rTempLow_GenCoolingOutlet": { "codes": [ "02_08_036" ], "in_param_dict": true, "cn": "发电机冷却出口温度低", "unit": "", "subsystem": "Generator", "values": { "default": "-222", "value_sc1_4mw": "-222", "value_sc1_4mw_b": "-222", "golden_kk_2014_12": "-222", "value_xuyi_legacy_other_model": "-35" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rTempLow_GenStator": { "codes": [ "02_08_014", "02_08_018", "02_08_022" ], "in_param_dict": true, "cn": "发电机定子温度低", "unit": "", "subsystem": "Generator", "values": { "default": "-25", "value_sc1_4mw": "-20", "value_sc1_4mw_b": "-20", "golden_kk_2014_12": "-15", "value_xuyi_legacy_other_model": "-25" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempLow_Nacelle": { "codes": [ "02_03_002" ], "in_param_dict": true, "cn": "机舱温度过低阈值1", "unit": "℃", "subsystem": "NacelleSystem", "values": { "default": "-5", "value_sc1_4mw": "-25", "value_sc1_4mw_b": "-25", "golden_kk_2014_12": "-25", "value_xuyi_legacy_other_model": "-25" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempLow_Outdoor": { "codes": [ "02_11_017" ], "in_param_dict": true, "cn": "舱外温度过低阈值1", "unit": "℃", "subsystem": "NacelleSystem", "values": { "default": "-5", "value_sc1_4mw": "-15", "value_sc1_4mw_b": "-15", "golden_kk_2014_12": "-15", "value_xuyi_legacy_other_model": "-15" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempLow_TowerBase": { "codes": [ "03_03_002" ], "in_param_dict": true, "cn": "塔底低温报警阈值(sc-1在变频器集装箱)", "unit": "℃", "subsystem": "Cabinet", "values": { "default": "-150", "value_sc1_4mw": "0", "value_sc1_4mw_b": "0", "golden_kk_2014_12": "0", "value_xuyi_legacy_other_model": "-30" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMAX_CabinetNacelle": { "codes": [ "02_02_011" ], "in_param_dict": true, "cn": "机舱控制柜温度超过设计值", "unit": "℃", "subsystem": "Cabinet", "values": { "default": "52", "value_sc1_4mw": "50", "value_sc1_4mw_b": "50", "golden_kk_2014_12": "52", "value_xuyi_legacy_other_model": "52" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rTempMAX_CabinetTower": { "codes": [ "03_02_026" ], "in_param_dict": true, "cn": "塔底控制柜温度超过设计值", "unit": "℃", "subsystem": "Cabinet", "values": { "default": "52", "value_sc1_4mw": "50", "value_sc1_4mw_b": "50", "golden_kk_2014_12": "52", "value_xuyi_legacy_other_model": "52" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rTempMAX_GearBearingDE": { "codes": [ "02_05_030" ], "in_param_dict": true, "cn": "齿轮箱中速段驱动端温度超过设计值", "unit": "", "subsystem": "Gearbox", "values": { "default": "90", "value_sc1_4mw": "90", "value_sc1_4mw_b": "90", "golden_kk_2014_12": "75", "value_xuyi_legacy_other_model": "90" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMAX_GearBearingNDE": { "codes": [ "02_05_035" ], "in_param_dict": true, "cn": "齿轮箱非驱动端温度超过设计值", "unit": "", "subsystem": "Gearbox", "values": { "default": "90", "value_sc1_4mw": "90", "value_sc1_4mw_b": "90", "golden_kk_2014_12": "90", "value_xuyi_legacy_other_model": "90" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempMAX_GearOilInlet": { "codes": [ "02_05_021" ], "in_param_dict": true, "cn": "齿轮箱入口温度超过设计值", "unit": "", "subsystem": "Gearbox", "values": { "default": "75", "value_sc1_4mw": "75", "value_sc1_4mw_b": "75", "golden_kk_2014_12": "75", "value_xuyi_legacy_other_model": "0" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rTempMAX_GearOilSump": { "codes": [ "02_05_017" ], "in_param_dict": true, "cn": "齿轮箱油温高于设计值", "unit": "", "subsystem": "Gearbox", "values": { "default": "75", "value_sc1_4mw": "75", "value_sc1_4mw_b": "75", "golden_kk_2014_12": "75", "value_xuyi_legacy_other_model": "75" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempMAX_GenBearDE": { "codes": [ "02_08_028" ], "in_param_dict": true, "cn": "发电机驱动端温度太高", "unit": "", "subsystem": "Generator", "values": { "default": "90", "value_sc1_4mw": "90", "value_sc1_4mw_b": "90", "golden_kk_2014_12": "100", "value_xuyi_legacy_other_model": "90" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMAX_GenBearNDE": { "codes": [ "02_08_032" ], "in_param_dict": true, "cn": "发电机非驱动端温度太高", "unit": "", "subsystem": "Generator", "values": { "default": "90", "value_sc1_4mw": "80", "value_sc1_4mw_b": "80", "golden_kk_2014_12": "100", "value_xuyi_legacy_other_model": "90" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMAX_GenCoolingInlet": { "codes": [ "02_08_037" ], "in_param_dict": true, "cn": "发电机冷却入口温度上限", "unit": "", "subsystem": "Generator", "values": { "default": "95", "value_sc1_4mw": "95", "value_sc1_4mw_b": "95", "golden_kk_2014_12": "95", "value_xuyi_legacy_other_model": "95" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempMAX_GenCoolingOutlet": { "codes": [ "02_08_037" ], "in_param_dict": true, "cn": "发电机冷却出口温度上限", "unit": "", "subsystem": "Generator", "values": { "default": "130", "value_sc1_4mw": "130", "value_sc1_4mw_b": "130", "golden_kk_2014_12": "130", "value_xuyi_legacy_other_model": "130" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempMAX_GenStator": { "codes": [ "02_08_015", "02_08_019", "02_08_023" ], "in_param_dict": true, "cn": "发电机定子温度上限", "unit": "", "subsystem": "Generator", "values": { "default": "150", "value_sc1_4mw": "160", "value_sc1_4mw_b": "160", "golden_kk_2014_12": "160", "value_xuyi_legacy_other_model": "150" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMAX_Nacelle": { "codes": [ "02_03_003" ], "in_param_dict": true, "cn": "机舱温度过高阈值2", "unit": "℃", "subsystem": "NacelleSystem", "values": { "default": "48", "value_sc1_4mw": "48", "value_sc1_4mw_b": "48", "golden_kk_2014_12": "50", "value_xuyi_legacy_other_model": "48" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMAX_Outdoor": { "codes": [ "02_11_018" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rTempMAX_RotorBearingA": { "codes": [ "02_04_028" ], "in_param_dict": true, "cn": "主轴轴承温度太高故障", "unit": "℃", "subsystem": "Drivetrain", "values": { "default": "60", "value_sc1_4mw": "70", "value_sc1_4mw_b": "70", "golden_kk_2014_12": "70", "value_xuyi_legacy_other_model": "60" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMAX_TowerBase": { "codes": [ "03_03_003" ], "in_param_dict": true, "cn": "塔底温度超过设计值(sc-1在变频器集装箱)", "unit": "℃", "subsystem": "Cabinet", "values": { "default": "450", "value_sc1_4mw": "45", "value_sc1_4mw_b": "45", "golden_kk_2014_12": "45", "value_xuyi_legacy_other_model": "45" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMIN_CabinetNacelle": { "codes": [ "02_02_012", "03_02_109" ], "in_param_dict": true, "cn": "机舱控制柜温度低于设计值", "unit": "℃", "subsystem": "Cabinet", "values": { "default": "-5", "value_sc1_4mw": "-20", "value_sc1_4mw_b": "-20", "golden_kk_2014_12": "-5", "value_xuyi_legacy_other_model": "-5" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rTempMIN_CabinetTower": { "codes": [ "03_02_027", "03_02_109" ], "in_param_dict": true, "cn": "塔底控制柜温度低于设计值", "unit": "℃", "subsystem": "Cabinet", "values": { "default": "0", "value_sc1_4mw": "-20", "value_sc1_4mw_b": "-20", "golden_kk_2014_12": "-3", "value_xuyi_legacy_other_model": "-3" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMIN_GearBearingDE": { "codes": [ "02_05_033" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rTempMIN_GearOilInlet": { "codes": [ "02_05_022" ], "in_param_dict": true, "cn": "齿轮箱入口温度低于设计值", "unit": "", "subsystem": "Gearbox", "values": { "default": "-20", "value_sc1_4mw": "-20", "value_sc1_4mw_b": "-20", "golden_kk_2014_12": "-25", "value_xuyi_legacy_other_model": "0" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMIN_GearOilSump": { "codes": [ "02_05_018" ], "in_param_dict": true, "cn": "齿轮箱温度低于设计值", "unit": "", "subsystem": "Gearbox", "values": { "default": "5", "value_sc1_4mw": "-20", "value_sc1_4mw_b": "-20", "golden_kk_2014_12": "-25", "value_xuyi_legacy_other_model": "-5" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMIN_GenBearDE": { "codes": [ "02_08_029" ], "in_param_dict": true, "cn": "发电机驱动端温度太低", "unit": "", "subsystem": "Generator", "values": { "default": "-30", "value_sc1_4mw": "-20", "value_sc1_4mw_b": "-20", "golden_kk_2014_12": "-20", "value_xuyi_legacy_other_model": "-30" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMIN_GenBearNDE": { "codes": [ "02_08_033" ], "in_param_dict": true, "cn": "发电机非驱动端温度太低", "unit": "", "subsystem": "Generator", "values": { "default": "-30", "value_sc1_4mw": "-20", "value_sc1_4mw_b": "-20", "golden_kk_2014_12": "-20", "value_xuyi_legacy_other_model": "-30" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMIN_GenCoolingInlet": { "codes": [ "02_08_038" ], "in_param_dict": true, "cn": "发电机冷却入口温度下限", "unit": "", "subsystem": "Generator", "values": { "default": "-222", "value_sc1_4mw": "-222", "value_sc1_4mw_b": "-222", "golden_kk_2014_12": "-222", "value_xuyi_legacy_other_model": "-273" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rTempMIN_GenCoolingOutlet": { "codes": [ "02_08_038" ], "in_param_dict": true, "cn": "发电机冷却出口温度下限", "unit": "", "subsystem": "Generator", "values": { "default": "-222", "value_sc1_4mw": "-222", "value_sc1_4mw_b": "-222", "golden_kk_2014_12": "-222", "value_xuyi_legacy_other_model": "-40" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rTempMIN_GenStator": { "codes": [ "02_08_016", "02_08_020", "02_08_024" ], "in_param_dict": true, "cn": "发电机定子温度下限", "unit": "", "subsystem": "Generator", "values": { "default": "-30", "value_sc1_4mw": "-30", "value_sc1_4mw_b": "-30", "golden_kk_2014_12": "-20", "value_xuyi_legacy_other_model": "-30" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMIN_Nacelle": { "codes": [ "02_03_004" ], "in_param_dict": true, "cn": "机舱温度过低阈值2", "unit": "℃", "subsystem": "NacelleSystem", "values": { "default": "-10", "value_sc1_4mw": "-30", "value_sc1_4mw_b": "-30", "golden_kk_2014_12": "-30", "value_xuyi_legacy_other_model": "-30" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTempMIN_Outdoor": { "codes": [ "02_11_019" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rTempMIN_TowerBase": { "codes": [ "03_03_004" ], "in_param_dict": true, "cn": "塔底温度低于设计值(sc-1在变频器集装箱)", "unit": "℃", "subsystem": "Cabinet", "values": { "default": "-200", "value_sc1_4mw": "-200", "value_sc1_4mw_b": "-200", "golden_kk_2014_12": "-200", "value_xuyi_legacy_other_model": "-200" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempRearBearingHighError": { "codes": [ "04_04_006" ], "in_param_dict": true, "cn": "SC1-主轴后轴承温度高报警", "unit": "℃", "subsystem": "Drivetrain", "values": { "default": "70", "value_sc1_4mw": "70", "value_sc1_4mw_b": "70", "golden_kk_2014_12": "70", "value_xuyi_legacy_other_model": "70" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempRearBearingHighWarning": { "codes": [ "04_04_005" ], "in_param_dict": true, "cn": "SC1-主轴后轴承温度高报警", "unit": "℃", "subsystem": "Drivetrain", "values": { "default": "60", "value_sc1_4mw": "60", "value_sc1_4mw_b": "60", "golden_kk_2014_12": "60", "value_xuyi_legacy_other_model": "60" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTempToDisableOverPower": { "codes": [ "03_03_102" ], "in_param_dict": true, "cn": "电缆温度超过允许最大温度,禁止超发功能", "unit": "℃", "subsystem": "NacelleSystem", "values": { "default": "80", "value_sc1_4mw": "80", "value_sc1_4mw_b": "80", "golden_kk_2014_12": "80", "value_xuyi_legacy_other_model": "80" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTemp_CS_GENOutletHigh": { "codes": [ "04_08_013" ], "in_param_dict": true, "cn": "冷却系统发电机出口水温过高报警", "unit": "摄氏度", "subsystem": "CoolingSystem", "values": { "default": "130", "value_sc1_4mw": "130", "value_sc1_4mw_b": "130", "golden_kk_2014_12": "130", "value_xuyi_legacy_other_model": "130" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rTowerResoGenSpeedDown": { "codes": [ "03_09_114" ], "in_param_dict": true, "cn": "共振区转速下限", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "600", "value_sc1_4mw": "690", "value_sc1_4mw_b": "690", "golden_kk_2014_12": "690", "value_xuyi_legacy_other_model": "650" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rTowerResoGenSpeedUp": { "codes": [ "03_09_114" ], "in_param_dict": true, "cn": "共振区转速上限", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "700", "value_sc1_4mw": "760", "value_sc1_4mw_b": "760", "golden_kk_2014_12": "760", "value_xuyi_legacy_other_model": "850" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rVibrationForeaftDirection": { "codes": [ "02_04_025" ], "in_param_dict": true, "cn": "统计震动过大的阈值", "unit": "无", "subsystem": "NacelleSystem", "values": { "default": "1.2", "value_sc1_4mw": "1.2", "value_sc1_4mw_b": "1.2", "golden_kk_2014_12": "1.2", "value_xuyi_legacy_other_model": "1" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rVibrationOmniDirection": { "codes": [ "02_04_024" ], "in_param_dict": true, "cn": "统计震动过大的阈值", "unit": "无", "subsystem": "NacelleSystem", "values": { "default": "1.2", "value_sc1_4mw": "1.2", "value_sc1_4mw_b": "1.2", "golden_kk_2014_12": "1.2", "value_xuyi_legacy_other_model": "1.2" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rVoltageForGridLost_Volt": { "codes": [ "03_04_018" ], "in_param_dict": true, "cn": "电网掉电电压阈值", "unit": "", "subsystem": "GridMeasurement", "values": { "default": "50", "value_sc1_4mw": "50", "value_sc1_4mw_b": "50", "golden_kk_2014_12": "50", "value_xuyi_legacy_other_model": "50" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rWCSGENInletTempHigh2": { "codes": [ "02_08_124" ], "in_param_dict": true, "cn": "发电机高澜水冷入口温度高二级阈值", "unit": "", "subsystem": "Generator", "values": { "default": "50", "value_sc1_4mw": "50", "value_sc1_4mw_b": "50", "golden_kk_2014_12": "50", "value_xuyi_legacy_other_model": "50" }, "five_col_identical": true, "golden_differs_from_default": false, "evidence_tier": "D_template_default" }, "PAR_rWindAboveActivateYawTracking": { "codes": [ "02_11_105" ], "in_param_dict": true, "cn": "小风禁止自动对风风速", "unit": "", "subsystem": "YawSystem", "values": { "default": "2.5", "value_sc1_4mw": "2", "value_sc1_4mw_b": "2", "golden_kk_2014_12": "3", "value_xuyi_legacy_other_model": "2" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rWindAboveStart": { "codes": [ "02_11_104" ], "in_param_dict": true, "cn": "启动风速", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "3.5", "value_sc1_4mw": "3.5", "value_sc1_4mw_b": "3.5", "golden_kk_2014_12": "3.5", "value_xuyi_legacy_other_model": "2.5" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rWindRestartAtMaxWind": { "codes": [ "02_11_106" ], "in_param_dict": true, "cn": "大风恢复风速门限阈值", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "18", "value_sc1_4mw": "22", "value_sc1_4mw_b": "22", "golden_kk_2014_12": "22", "value_xuyi_legacy_other_model": "18" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rWindSpeedCheckSensors": { "codes": [ "02_11_107" ], "in_param_dict": true, "cn": "监测风速仪、风向标数据不刷新的起始风速值", "unit": "m/s", "subsystem": "NacelleSystem", "values": { "default": "2.5", "value_sc1_4mw": "3", "value_sc1_4mw_b": "3", "golden_kk_2014_12": "3", "value_xuyi_legacy_other_model": "2" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rWindSpeedLimitToAutoGrease": { "codes": [ "02_10_109" ], "in_param_dict": true, "cn": "允许偏航自润滑的最高风速", "unit": "", "subsystem": "YawSystem", "values": { "default": "15", "value_sc1_4mw": "25", "value_sc1_4mw_b": "25", "golden_kk_2014_12": "25", "value_xuyi_legacy_other_model": "25" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_rXX": { "codes": [ "04_04_005", "04_04_006" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_rYawSensorOffsetAtNorthPos": { "codes": [ "02_10_012" ], "in_param_dict": true, "cn": "机舱对北角度偏差", "unit": "", "subsystem": "YawSystem", "values": { "default": "0", "value_sc1_4mw": "0", "value_sc1_4mw_b": "0", "golden_kk_2014_12": "0", "value_xuyi_legacy_other_model": "90" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rYawTurnsCableTwistPreSTOP": { "codes": [ "02_10_012", "02_10_102" ], "in_param_dict": true, "cn": "预解缆偏航圈数", "unit": "", "subsystem": "YawSystem", "values": { "default": "1.4", "value_sc1_4mw": "1.4", "value_sc1_4mw_b": "1.4", "golden_kk_2014_12": "1.4", "value_xuyi_legacy_other_model": "2.4" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_rYawTurnsCableTwist_STOP": { "codes": [ "02_10_012" ], "in_param_dict": true, "cn": "一级限位开关偏航角度", "unit": "", "subsystem": "YawSystem", "values": { "default": "1.5", "value_sc1_4mw": "1.5", "value_sc1_4mw_b": "1.5", "golden_kk_2014_12": "1.5", "value_xuyi_legacy_other_model": "2.5" }, "five_col_identical": false, "golden_differs_from_default": false, "evidence_tier": "C_partial" }, "PAR_tCBCheckBlockConverterError": { "codes": [ "03_05_005", "03_06_014" ], "in_param_dict": false, "evidence_tier": "X_param_not_in_dict" }, "PAR_tCVTWaterCoolHeaterOnWorking": { "codes": [ "03_05_063" ], "in_param_dict": true, "cn": "高澜变频器水冷加热器运行超时", "unit": "", "subsystem": "ConverterContainer", "values": { "default": "T#60m", "value_sc1_4mw": "T#60m", "value_sc1_4mw_b": "T#60m", "golden_kk_2014_12": "3600000", "value_xuyi_legacy_other_model": "T#60m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tCVT_DCLinkChargeTimeout": { "codes": [ "04_12_015" ], "in_param_dict": true, "cn": "变频器直流母线充电超时", "unit": "", "subsystem": "ConverterContainer", "values": { "default": "T#30s", "value_sc1_4mw": "T#45s", "value_sc1_4mw_b": "T#10s", "golden_kk_2014_12": "10000", "value_xuyi_legacy_other_model": "T#30s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tCVT_LVRT_Timeout": { "codes": [ "04_12_022" ], "in_param_dict": true, "cn": "LVRT超时时间", "unit": "", "subsystem": "ConverterContainer", "values": { "default": "T#5s", "value_sc1_4mw": "", "value_sc1_4mw_b": "T#5s", "golden_kk_2014_12": "5000", "value_xuyi_legacy_other_model": "" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tCVT_MCBCloseTimeout": { "codes": [ "04_12_021" ], "in_param_dict": true, "cn": "变频器合MCB超时时间", "unit": "", "subsystem": "ConverterContainer", "values": { "default": "T#20s", "value_sc1_4mw": "", "value_sc1_4mw_b": "T#20s", "golden_kk_2014_12": "20000", "value_xuyi_legacy_other_model": "" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tConverterHeatingModeTimeout": { "codes": [ "03_05_060" ], "in_param_dict": true, "cn": "变频器加热模式超时", "unit": "", "subsystem": "ConverterContainer", "values": { "default": "T#60m", "value_sc1_4mw": "T#60m", "value_sc1_4mw_b": "T#120m", "golden_kk_2014_12": "5400000", "value_xuyi_legacy_other_model": "T#60m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tDelayCircuitBrakerClose": { "codes": [ "03_05_008" ], "in_param_dict": true, "cn": "变频器主断路器闭合超时", "unit": "", "subsystem": "ConverterContainer", "values": { "default": "T#10s", "value_sc1_4mw": "T#10s", "value_sc1_4mw_b": "T#10s", "golden_kk_2014_12": "10000", "value_xuyi_legacy_other_model": "T#10s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tDelayForHydraulicsCompressionLevel1": { "codes": [ "02_09_020" ], "in_param_dict": true, "cn": "主回路打压到20BAR超时", "unit": "", "subsystem": "HSBrakeSystem", "values": { "default": "T#1s", "value_sc1_4mw": "T#1s", "value_sc1_4mw_b": "T#1s", "golden_kk_2014_12": "15000", "value_xuyi_legacy_other_model": "T#1s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tDelayForHydraulicsDecompression": { "codes": [ "02_09_019" ], "in_param_dict": true, "cn": "主回路泄压到0BAR超时", "unit": "", "subsystem": "HSBrakeSystem", "values": { "default": "T#1s", "value_sc1_4mw": "T#1s", "value_sc1_4mw_b": "T#1s", "golden_kk_2014_12": "20000", "value_xuyi_legacy_other_model": "T#1s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tDelayGearOilFilterClogged_STOP": { "codes": [ "02_05_003" ], "in_param_dict": true, "cn": "油滤堵塞判断时间延迟", "unit": "", "subsystem": "Gearbox", "values": { "default": "T#100h", "value_sc1_4mw": "T#100h", "value_sc1_4mw_b": "T#100h", "golden_kk_2014_12": "360000000", "value_xuyi_legacy_other_model": "T#15s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tDelayGearOilLevel_STOP": { "codes": [ "02_05_005" ], "in_param_dict": true, "cn": "油位停机故障时间延迟", "unit": "", "subsystem": "Gearbox", "values": { "default": "T#20s", "value_sc1_4mw": "T#40s", "value_sc1_4mw_b": "T#40s", "golden_kk_2014_12": "400000", "value_xuyi_legacy_other_model": "T#40s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tDelayGearOilLevel_Warning": { "codes": [ "02_05_004" ], "in_param_dict": true, "cn": "油位报警时间延迟", "unit": "", "subsystem": "Gearbox", "values": { "default": "T#10s", "value_sc1_4mw": "T#20s", "value_sc1_4mw_b": "T#20s", "golden_kk_2014_12": "200000", "value_xuyi_legacy_other_model": "T#20s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tDelayHydPumpTime_MAX": { "codes": [ "02_09_017" ], "in_param_dict": true, "cn": "液压泵运行时间过长时间上限", "unit": "", "subsystem": "HSBrakeSystem", "values": { "default": "T#20s", "value_sc1_4mw": "T#20s", "value_sc1_4mw_b": "T#20s", "golden_kk_2014_12": "30000", "value_xuyi_legacy_other_model": "T#20s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tGearboxHeatingModeTimeout": { "codes": [ "02_05_110" ], "in_param_dict": true, "cn": "齿轮箱冷启动超时判断", "unit": "", "subsystem": "Gearbox", "values": { "default": "T#6h", "value_sc1_4mw": "T#6h", "value_sc1_4mw_b": "T#6h", "golden_kk_2014_12": "21600000", "value_xuyi_legacy_other_model": "T#6d" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tGenStatorDewShortCircuit": { "codes": [ "02_08_100" ], "in_param_dict": true, "cn": "发电机定子冷凝故障延时", "unit": "", "subsystem": "Generator", "values": { "default": "T#30m", "value_sc1_4mw": "T#30m", "value_sc1_4mw_b": "T#30m", "golden_kk_2014_12": "43200000", "value_xuyi_legacy_other_model": "T#12h" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tGenWaterCoolHeaterOnWorking": { "codes": [ "02_08_136" ], "in_param_dict": true, "cn": "发电机高澜水冷加热器运行超时", "unit": "", "subsystem": "Generator", "values": { "default": "T#60m", "value_sc1_4mw": "T#60m", "value_sc1_4mw_b": "T#60m", "golden_kk_2014_12": "3600000", "value_xuyi_legacy_other_model": "T#60m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tIntervalMaxPitchComError": { "codes": [ "04_02_036" ], "in_param_dict": true, "cn": "监测变桨通讯报警频繁时间间隔", "unit": "", "subsystem": "Pitchsystem", "values": { "default": "t#5m", "value_sc1_4mw": "t#5m", "value_sc1_4mw_b": "t#5m", "golden_kk_2014_12": "300000", "value_xuyi_legacy_other_model": "" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tIntervalMaxStartHydPump": { "codes": [ "02_09_021" ], "in_param_dict": true, "cn": "监测液压泵启动频繁时间间隔", "unit": "", "subsystem": "HSBrakeSystem", "values": { "default": "T#10m", "value_sc1_4mw": "T#10m", "value_sc1_4mw_b": "T#10m", "golden_kk_2014_12": "600000", "value_xuyi_legacy_other_model": "T#10m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tMaxTimeWithoutPitchMove": { "codes": [ "03_09_110" ], "in_param_dict": true, "cn": "桨叶自润滑周期", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "T#48h", "value_sc1_4mw": "T#48h", "value_sc1_4mw_b": "T#48h", "golden_kk_2014_12": "172800000", "value_xuyi_legacy_other_model": "T#48h" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tResonanceModeTimeMax": { "codes": [ "03_09_114" ], "in_param_dict": true, "cn": "风机处于共振区超时", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "T#20s", "value_sc1_4mw": "T#30s", "value_sc1_4mw_b": "T#30s", "golden_kk_2014_12": "30000", "value_xuyi_legacy_other_model": "T#30s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tSELFTEST_PitchBatteryStatusError": { "codes": [ "03_09_030", "03_09_031", "03_09_032" ], "in_param_dict": true, "cn": "桨叶自检超时延时", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "T#12s", "value_sc1_4mw": "T#12s", "value_sc1_4mw_b": "T#12s", "golden_kk_2014_12": "14000", "value_xuyi_legacy_other_model": "T#12s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tSetDelayForBatteryChargerFault": { "codes": [ "01_05_062" ], "in_param_dict": true, "cn": "变桨系统电池充电回路故障setdelay", "unit": "", "subsystem": "Pitchsystem", "values": { "default": "T#2m", "value_sc1_4mw": "T#2m", "value_sc1_4mw_b": "T#2m", "golden_kk_2014_12": "120000", "value_xuyi_legacy_other_model": "T#2m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tSetDelayForCANProfibus": { "codes": [ "01_05_070", "01_05_104", "01_05_106" ], "in_param_dict": true, "cn": "变桨系统CAN故障Setdelay", "unit": "", "subsystem": "Pitchsystem", "values": { "default": "t#120ms", "value_sc1_4mw": "t#120ms", "value_sc1_4mw_b": "t#120ms", "golden_kk_2014_12": "120", "value_xuyi_legacy_other_model": "t#120ms" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tSetDelayForEtherCAT": { "codes": [ "03_06_018" ], "in_param_dict": true, "cn": "EtherCAT故障延时", "unit": "", "subsystem": "PLCSystem", "values": { "default": "t#100ms", "value_sc1_4mw": "t#100ms", "value_sc1_4mw_b": "t#100ms", "golden_kk_2014_12": "20", "value_xuyi_legacy_other_model": "t#100ms" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tSetDelayForFrequencyHigh": { "codes": [ "03_04_010" ], "in_param_dict": true, "cn": "电网频率高延时", "unit": "", "subsystem": "GridMeasurement", "values": { "default": "T#30m", "value_sc1_4mw": "T#2m", "value_sc1_4mw_b": "T#2m", "golden_kk_2014_12": "420000", "value_xuyi_legacy_other_model": "T#2m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tSetDelayForFrequencyLow": { "codes": [ "03_04_011" ], "in_param_dict": true, "cn": "电网频率低延时", "unit": "", "subsystem": "GridMeasurement", "values": { "default": "T#30m", "value_sc1_4mw": "T#30m", "value_sc1_4mw_b": "T#30m", "golden_kk_2014_12": "1920000", "value_xuyi_legacy_other_model": "T#30m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tSetDelayForFrequencyMax": { "codes": [ "03_04_020" ], "in_param_dict": true, "cn": "电网频率太高延时", "unit": "", "subsystem": "GridMeasurement", "values": { "default": "T#200ms", "value_sc1_4mw": "T#200ms", "value_sc1_4mw_b": "T#200ms", "golden_kk_2014_12": "5000", "value_xuyi_legacy_other_model": "T#200ms" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tSetDelayForFrequencyMin": { "codes": [ "03_04_021" ], "in_param_dict": true, "cn": "电网频率太低延时", "unit": "", "subsystem": "GridMeasurement", "values": { "default": "T#500ms", "value_sc1_4mw": "T#500ms", "value_sc1_4mw_b": "T#500ms", "golden_kk_2014_12": "8000", "value_xuyi_legacy_other_model": "T#500ms" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tSetDelayForGridVoltageLow": { "codes": [ "03_04_006", "03_04_007", "03_04_008" ], "in_param_dict": true, "cn": "低电压故障延时", "unit": "", "subsystem": "GridMeasurement", "values": { "default": "T#5s", "value_sc1_4mw": "T#5s", "value_sc1_4mw_b": "T#5s", "golden_kk_2014_12": "5000", "value_xuyi_legacy_other_model": "T#5s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeOutBrakeMode100": { "codes": [ "03_09_012" ], "in_param_dict": true, "cn": "100号刹车超时", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "t#20s", "value_sc1_4mw": "t#42s", "value_sc1_4mw_b": "t#42s", "golden_kk_2014_12": "42000", "value_xuyi_legacy_other_model": "T#42s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeOutBrakeMode50": { "codes": [ "03_09_013" ], "in_param_dict": true, "cn": "50号刹车超时", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "t#60s", "value_sc1_4mw": "t#60s", "value_sc1_4mw_b": "t#60s", "golden_kk_2014_12": "60000", "value_xuyi_legacy_other_model": "t#60s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeOutBrakeMode51": { "codes": [ "03_09_011" ], "in_param_dict": true, "cn": "51号刹车超时", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "t#60s", "value_sc1_4mw": "t#60s", "value_sc1_4mw_b": "t#60s", "golden_kk_2014_12": "75000", "value_xuyi_legacy_other_model": "t#60s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeOutParallelOperationOK": { "codes": [ "03_05_003" ], "in_param_dict": true, "cn": "变频器机侧开启超时", "unit": "", "subsystem": "ConverterContainer", "values": { "default": "T#20s", "value_sc1_4mw": "T#35s", "value_sc1_4mw_b": "T#10s", "golden_kk_2014_12": "20000", "value_xuyi_legacy_other_model": "T#20s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeOutReadyToOperateOK": { "codes": [ "03_05_001" ], "in_param_dict": true, "cn": "变频器运行在转速范围内,未发送Ready信号超时", "unit": "", "subsystem": "ConverterContainer", "values": { "default": "T#20s", "value_sc1_4mw": "T#12s", "value_sc1_4mw_b": "T#12s", "golden_kk_2014_12": "12000", "value_xuyi_legacy_other_model": "T#20s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeoutCutInMode": { "codes": [ "04_16_006" ], "in_param_dict": true, "cn": "切入并网超时时间", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "T#1m", "value_sc1_4mw": "T#1m", "value_sc1_4mw_b": "T#1m", "golden_kk_2014_12": "60000", "value_xuyi_legacy_other_model": "T#1m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeoutSelftest1": { "codes": [ "04_16_001" ], "in_param_dict": true, "cn": "自检1超时时间", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "T#1m", "value_sc1_4mw": "T#1m", "value_sc1_4mw_b": "T#1m", "golden_kk_2014_12": "60000", "value_xuyi_legacy_other_model": "T#1m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeoutSelftest2": { "codes": [ "04_16_002" ], "in_param_dict": true, "cn": "自检2超时时间", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "T#1m", "value_sc1_4mw": "T#1m", "value_sc1_4mw_b": "T#1m", "golden_kk_2014_12": "60000", "value_xuyi_legacy_other_model": "T#1m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeoutSelftest3": { "codes": [ "04_16_003" ], "in_param_dict": true, "cn": "自检3超时时间", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "T#1m", "value_sc1_4mw": "T#1m", "value_sc1_4mw_b": "T#1m", "golden_kk_2014_12": "60000", "value_xuyi_legacy_other_model": "T#1m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeoutSelftest4": { "codes": [ "04_16_004" ], "in_param_dict": true, "cn": "自检4超时时间", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "T#1m", "value_sc1_4mw": "T#1m", "value_sc1_4mw_b": "T#15m", "golden_kk_2014_12": "1200000", "value_xuyi_legacy_other_model": "T#1m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeoutSelftest5": { "codes": [ "04_16_015" ], "in_param_dict": true, "cn": "自检5超时时间", "unit": "min", "subsystem": "TurbineStateMachine", "values": { "default": "T#10m", "value_sc1_4mw": "", "value_sc1_4mw_b": "T#10m", "golden_kk_2014_12": "600000", "value_xuyi_legacy_other_model": "" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tTimeoutStartMode": { "codes": [ "04_16_005" ], "in_param_dict": true, "cn": "启动模式超时时间", "unit": "", "subsystem": "TurbineStateMachine", "values": { "default": "T#5m", "value_sc1_4mw": "T#10m", "value_sc1_4mw_b": "T#10m", "golden_kk_2014_12": "600000", "value_xuyi_legacy_other_model": "T#5m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tUPS_Batt_Low_Shutdown_Time": { "codes": [ "04_11_026" ], "in_param_dict": true, "cn": "UPS过低持续时长", "unit": "", "subsystem": "GCC", "values": { "default": "T#180s", "value_sc1_4mw": "T#180s", "value_sc1_4mw_b": "T#180s", "golden_kk_2014_12": "180000", "value_xuyi_legacy_other_model": "T#180s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tWarningToSTOP_GeneratorBrushes": { "codes": [ "02_08_007" ], "in_param_dict": true, "cn": "发电机碳刷磨损停机延时", "unit": "", "subsystem": "Generator", "values": { "default": "T#168h", "value_sc1_4mw": "T#168h", "value_sc1_4mw_b": "T#168h", "golden_kk_2014_12": "604800000", "value_xuyi_legacy_other_model": "T#96h" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tYawMotorTimeTooLong": { "codes": [ "02_10_010" ], "in_param_dict": true, "cn": "偏航电机运行时间过长延时", "unit": "", "subsystem": "YawSystem", "values": { "default": "T#45m", "value_sc1_4mw": "T#45m", "value_sc1_4mw_b": "T#45m", "golden_kk_2014_12": "2700000", "value_xuyi_legacy_other_model": "T#45m" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" }, "PAR_tYawSlowDelay": { "codes": [ "02_10_008" ], "in_param_dict": true, "cn": "偏航速度过慢延时", "unit": "", "subsystem": "YawSystem", "values": { "default": "T#20S", "value_sc1_4mw": "T#10S", "value_sc1_4mw_b": "T#10S", "golden_kk_2014_12": "10000", "value_xuyi_legacy_other_model": "T#10s" }, "five_col_identical": false, "golden_differs_from_default": true, "evidence_tier": "B_golden_tuned" } }, "code_attributes": { "03_05_001": { "name": "SC_NoSignalForReadyToOperate", "cn": "变频器没有做好运行准备", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeOutReadyToOperateOK", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "03_05_002": { "name": "SC_RepFaultNoSignalReadyToOperate", "cn": "变频器没有做好运行准备的故障重复出现", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_003": { "name": "SC_NoSignalForParallelOperation", "cn": "变频器接入电网时间过长", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeOutParallelOperationOK", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_004": { "name": "SC_RepFaultNoSignalParallelOperation", "cn": "变频器接入电网时间过长故障重复出现", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_005": { "name": "SC_FaultInverter_CollectiveInformation", "cn": "变频器多种警告", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_027": { "name": "SC_ConverterCircuitBrakerTripped", "cn": "断路器断开", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_050": { "name": "SC_CutInTooFrequently_20m_5", "cn": "接入电网动作过于频繁", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#60s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_081": { "name": "SC_GridFailureByConverter", "cn": "变频器报告电网故障", "subsystem": "ConverterContainer", "level": "180-电网故障", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_101": { "name": "OC_ConverterReadyToOperate", "cn": "变频器做好运行准备", "subsystem": "ConverterContainer", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_102": { "name": "OC_ConverterGridConnected", "cn": "变频器报告电网已接入", "subsystem": "ConverterContainer", "level": "79-无限制发电", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "79", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_103": { "name": "OC_ConverterReadyToSwitchON", "cn": "变频器做好并网准备", "subsystem": "ConverterContainer", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_104": { "name": "OC_ConverterCircuitBrakerActive", "cn": "变频器报告断路器断开", "subsystem": "ConverterContainer", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_014": { "name": "SC_InterruptionCANbusConverter", "cn": "与变频器CAN通讯故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#15ms", "powerup_delay": "T#10s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_001": { "name": "OC_CS_Pump1LowON", "cn": "冷却系统循环泵1低速电机启动", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_002": { "name": "OC_CS_Pump2LowON", "cn": "冷却系统循环泵2低速电机启动", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_003": { "name": "OC_CS_Pump1HighON", "cn": "冷却系统循环泵1高速电机启动", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_004": { "name": "OC_CS_Pump2HighON", "cn": "冷却系统循环泵2高速电机启动", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_005": { "name": "SC_CS_Pump1LowControlManualMode", "cn": "冷却系统循环泵1低速电机手动模式开启", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_006": { "name": "SC_CS_Pump2LowControlManualMode", "cn": "冷却系统循环泵2低速电机手动模式开启", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_007": { "name": "SC_CS_Pump1LowControlForcelMode", "cn": "冷却系统循环泵1低速电机强制模式开启", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_008": { "name": "SC_CS_Pump2LowControlForcelMode", "cn": "冷却系统循环泵2低速电机强制模式开启", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_009": { "name": "SC_CS_Pump1HighControlManualMode", "cn": "冷却系统循环泵1高速电机手动模式开启", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_010": { "name": "SC_CS_Pump2HighControlManualMode", "cn": "冷却系统循环泵2高速电机手动模式开启", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_011": { "name": "SC_CS_Pump1HighControlForcelMode", "cn": "冷却系统循环泵1高速电机强制模式开启", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_012": { "name": "SC_CS_Pump2HighControlForcelMode", "cn": "冷却系统循环泵2高速电机强制模式开启", "subsystem": "CoolingSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_013": { "name": "SC_CS_GENOutletTempHighWarining", "cn": "冷却系统发电机出口温度过高", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_014": { "name": "SC_CS_PreLowWaringing", "cn": "冷却系统(入口或出口)压力低报警", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_015": { "name": "SC_CS_PreLowError", "cn": "冷却系统(入口或出口)压力低故障", "subsystem": "CoolingSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_016": { "name": "SC_CS_PumpOutputTempSensorFault", "cn": "冷却系统泵出口PT100故障", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_017": { "name": "SC_CS_GENOutletTempSensorFault", "cn": "冷却系统发电机出口PT100故障", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_018": { "name": "SC_CS_GBXOutletTempSensorFault", "cn": "冷却系统齿轮箱出口PT100故障", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": null, "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_019": { "name": "SC_CS_PumpOutletPreSensorFault", "cn": "冷却系统循环泵压力侧压力传感器故障", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_020": { "name": "SC_CS_PumpInletPreSensorFault", "cn": "冷却系统循环泵吸入侧压力传感器故障", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_021": { "name": "SC_CS_Pump1LowOverload", "cn": "水冷循环泵1低速热继触发", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_022": { "name": "SC_CS_Pump2LowOverload", "cn": "水冷循环泵2低速热继触发", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_023": { "name": "SC_CS_Pump1HighOverload", "cn": "水冷循环泵1高速热继触发", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_024": { "name": "SC_CS_Pump2HighOverload", "cn": "水冷循环泵2高速热继触发", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_025": { "name": "SC_CS_Pump1MCB", "cn": "水冷循环泵1空开跳开", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_026": { "name": "SC_CS_Pump2MCB", "cn": "水冷循环泵2空开跳开", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_027": { "name": "SC_CS_GBXOutletTempHighWarining", "cn": "冷却系统齿轮箱出口温度过高", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_13_003": { "name": "OC_AsymProxOffsetCalcRequired", "cn": "独立变桨需要自动校准", "subsystem": "CoreController", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_13_004": { "name": "SC_AsymSensorError", "cn": "独立变桨控制系统故障", "subsystem": "CoreController", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_13_005": { "name": "OC_AsymScaleDeltaFault", "cn": "独立变桨控制系统标定故障", "subsystem": "CoreController", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_032": { "name": "SC_NoCOM_C_Task", "cn": "与核心控制器通讯失败", "subsystem": "CoreController", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_118": { "name": "SC_PoweringUp", "cn": "主控制器上电初始化", "subsystem": "DataFlow", "level": "230-上电初始化", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "230", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_132": { "name": "SC_Init_Done", "cn": "初始化全部完成", "subsystem": "DataFlow", "level": "20-无原因待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "20", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_104": { "name": "OC_PLCPowerUpDelayElapsed", "cn": "PLC主任务重启后第一个执行周期完成", "subsystem": "DataFlow", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_060": { "name": "SC_FaultInputPT100_RotorBearingA", "cn": "主轴承温度测量PT100传感器故障", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_04_001": { "name": "SC_RotorOverSpeedLevel1", "cn": "低速端转速高于1级超速门限值", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms" ], "detectable_in_10min": false }, "02_04_003": { "name": "SC_GeneratorOverSpeedLevel1", "cn": "发电机转速高于1级超速门限值", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_005": { "name": "SC_RepFaultOverspeedLevel1", "cn": "风机低速端或发电机转速高于1级超速门限值故障重复出现", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_006": { "name": "SC_RotorSpeedUnequalGeneratorSpeed", "cn": "低速端转速与发电机转速不匹配", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1500ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_04_007": { "name": "SC_RotorDirectionWrong", "cn": "低速端旋转方向错误", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#2s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms" ], "detectable_in_10min": false }, "02_04_026": { "name": "SC_TempRotorBearingA_high", "cn": "主轴的轴承座温度过高警告", "subsystem": "Drivetrain", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_04_028": { "name": "SC_TempRotorBearingA_MAX", "cn": "主轴的轴承座温度过高故障", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_04_030": { "name": "SC_RepFaultTempRotorBearingA", "cn": "主轴的轴承座温度过高警告重复出现", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_039": { "name": "SC_GeneratorSpeedUnequalConverter", "cn": "主控系统测得的发电机转速与从变频器读得的不匹配", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_04_102": { "name": "OC_GeneratorSpeedBelowSlipLimit_MIN", "cn": "发电机转速小于切出电网转速", "subsystem": "Drivetrain", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms" ], "detectable_in_10min": false }, "03_09_009": { "name": "SC_MaxGenSpeedAtManualOP", "cn": "手动控制模式下,发电机转速过大", "subsystem": "Drivetrain", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms" ], "detectable_in_10min": false }, "04_04_001": { "name": "SC_MainBearingTempDeviationWarning", "cn": "前后主轴承温差异常", "subsystem": "DriveTrain", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_005": { "name": "SC_RearMainBearingTempWarning", "cn": "主轴后轴承温度过高报警", "subsystem": "DriveTrain", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_006": { "name": "SC_RearMainBearingTempError", "cn": "主轴后轴承温度过高故障", "subsystem": "DriveTrain", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_007": { "name": "SC_FaultPT100_RearMainRotorBearing", "cn": "主轴后轴承PT100故障", "subsystem": "DriveTrain", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_008": { "name": "SC_CouplingSlip", "cn": "传动链联轴器打滑", "subsystem": "DriveTrain", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_009": { "name": "SC_MainBearingsLubLevelLow", "cn": "主轴承润滑系统油位过低", "subsystem": "DriveTrain", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_010": { "name": "SC_MainBearingsLubPreHigh", "cn": "主轴承润滑系统油压过高", "subsystem": "DriveTrain", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_011": { "name": "SC_MainBearingsLubPistonNotMove", "cn": "主轴承润滑系统油脂分配器故障", "subsystem": "DriveTrain", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_012": { "name": "SC_Sensor1GeneratorImpulsesDefect", "cn": "发电机#1接近开关失效", "subsystem": "DriveTrain", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_013": { "name": "SC_Sensor2GeneratorImpulsesDefect", "cn": "发电机#2接近开关失效", "subsystem": "DriveTrain", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_027": { "name": "SC_MotorProtection_GearOilPump", "cn": "机舱柜中齿轮箱的油泵电机保护空开跳开", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_029": { "name": "SC_MotorProtection_GearFan", "cn": "机舱柜中齿轮箱冷却风扇保护空开跳开", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_031": { "name": "SC_NacelleFuseGearboxHeater", "cn": "机舱柜中齿轮箱油池加热器保护空开跳开", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_042": { "name": "SC_NacelleFuseMotorHeater_GearFanAndOilPump", "cn": "机舱柜中齿轮箱冷却风扇电机加热器或齿轮箱油泵电机加热器保护空开跳开", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_043": { "name": "SC_NacelleFuseHeater_GearOilPipe", "cn": "机舱柜中齿轮箱油管加热器保护开关跳开", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_054": { "name": "SC_FaultInputPT100_GearOilSump", "cn": "齿轮箱油池油温测量PT100传感器故障", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_02_055": { "name": "SC_FaultInputPT100_GearOilInlet", "cn": "齿轮箱入口油温测量PT100传感器故障", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_02_058": { "name": "SC_FaultInputPT100_GearBearingDE", "cn": "驱动端轴承温度测量PT100传感器故障", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_02_059": { "name": "SC_FaultInputPT100_GearBearingNDE", "cn": "非驱动端轴承温度测量PT100传感器故障", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_02_061": { "name": "SC_FaultInputPT100_GearBearingInterDE", "cn": "齿轮箱驱动端的中间轴温度测量PT100传感器故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_02_062": { "name": "SC_FaultInputPT100_GearBearingInterNDE", "cn": "齿轮箱非驱动端中间轴温度测量PT100传感器故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_02_064": { "name": "SC_FaultAI_GearOilPressureFilterInlet", "cn": "齿轮箱过滤器入口压力传感器故障", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_065": { "name": "SC_FaultAI_GearOilPressureGBXInlet", "cn": "齿轮箱入口压力传感器故障", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_104": { "name": "OC_HeaterGearOilPump_ON", "cn": "齿轮箱油泵加热器运行", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_105": { "name": "OC_GearFanLS_ON", "cn": "齿轮箱低速冷却风扇运行", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_106": { "name": "OC_GearOilPumpLS_ON", "cn": "齿轮箱低速油泵运行", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_107": { "name": "OC_GearOilPumpHS_ON", "cn": "齿轮箱高速油泵运行", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_108": { "name": "OC_GearOilHeater_ON", "cn": "齿轮箱油池加热器运行", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_112": { "name": "OC_GearFanHS_ON", "cn": "齿轮箱高速冷却风扇高速运行", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_113": { "name": "OC_HeaterGearFan_ON", "cn": "齿轮箱冷却风扇加热器运行", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_130": { "name": "OC_GearOilFilter_ON", "cn": "齿轮箱精滤器运行", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_132": { "name": "SC_GearOilFilter_Overload", "cn": "齿轮箱精滤器保护空开跳开", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_001": { "name": "SC_GearOilFilterClogged_Warning", "cn": "齿轮箱过滤器阻塞警告", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_05_002": { "name": "SC_RepFaultGearOilFilterClogged", "cn": "齿轮箱过滤器堵塞故障", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_003": { "name": "SC_GearOilFilterClogged_STOP", "cn": "齿轮箱过滤器阻塞故障,要求停机", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tDelayGearOilFilterClogged_STOP", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_004": { "name": "SC_GearOilLevel_Warning", "cn": "齿轮箱油池油位警告", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "PAR_tDelayGearOilLevel_Warning", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_005": { "name": "SC_GearOilLevel_STOP", "cn": "齿轮箱油池油位故障", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tDelayGearOilLevel_STOP", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_006": { "name": "SC_RepFaultGearOilLevel", "cn": "齿轮箱油池油位警告重复出现", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_008": { "name": "SC_GBXFilterOilPressure_MAX_STOP", "cn": "齿轮箱油压高于上限值", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#60s", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_05_015": { "name": "SC_TempGearOilSump_high", "cn": "齿轮箱油池温度过高警告", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_05_016": { "name": "SC_TempGearOilSump_low", "cn": "齿轮箱油池温度过低警告", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "50", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_05_017": { "name": "SC_TempGearOilSump_MAX", "cn": "齿轮箱油池温度过高故障", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min", "_10min" ], "detectable_in_10min": false }, "02_05_018": { "name": "SC_TempGearOilSump_MIN", "cn": "齿轮箱油池温度过低故障", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_05_019": { "name": "SC_TempGearOilInlet_high", "cn": "齿轮箱入口油温过高警告", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_05_020": { "name": "SC_TempGearOilInlet_low", "cn": "齿轮箱入口油温过低警告", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_05_021": { "name": "SC_TempGearOilInlet_MAX", "cn": "齿轮箱入口油温过高故障", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_05_022": { "name": "SC_TempGearOilInlet_MIN", "cn": "齿轮箱入口油温过低故障", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_05_027": { "name": "SC_RepFaultTempGearOilSump", "cn": "齿轮箱油池温度高于过高设定值或低于过低设定值故障重复出现", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_028": { "name": "SC_TempGearBearingDE_high", "cn": "齿轮箱驱动端轴承温度过高警告", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_05_030": { "name": "SC_TempGearBearingDE_MAX", "cn": "齿轮箱驱动端轴承温度过高故障", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_05_032": { "name": "SC_RepFaultTempGearBearingDE", "cn": "齿轮箱驱动端轴承温度过于过高设定值或低于过低设定值故障重复出现", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_033": { "name": "SC_TempGearBearingNDE_high", "cn": "齿轮箱非驱动端轴承温度过高警告", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_05_035": { "name": "SC_TempGearBearingNDE_MAX", "cn": "齿轮箱非驱动端轴承温度过高故障", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min", "_10min" ], "detectable_in_10min": false }, "02_05_037": { "name": "SC_RepFaultTempGearBearingNDE", "cn": "齿轮箱非驱动端轴承温度高于过高设定值或低于过低设定值故障重复出现", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_038": { "name": "SC_TempGearBearingInterDE_high", "cn": "齿轮箱驱动端轴承入口温度过高警告", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_039": { "name": "SC_TempGearBearingInterDE_MAX", "cn": "齿轮箱驱动端轴承入口温度过高故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_041": { "name": "SC_TempGearBearingInterNDE_high", "cn": "齿轮箱驱动端轴承入口温度过高警告", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_042": { "name": "SC_TempGearBearingInterNDE_MAX", "cn": "齿轮箱驱动端轴承入口温度过高故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_043": { "name": "SC_GearOilFilter_TempHigh", "cn": "齿轮箱过滤器的油温过高", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_044": { "name": "SC_GearOilFilter_PressureHigh", "cn": "齿轮箱过滤器压力过大", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_045": { "name": "SC_GearOilFilterOffLine_Blocking", "cn": "齿轮箱精滤器堵塞", "subsystem": "GearBox", "level": "40-警告待机", "reset_mode": "M", "type": "I", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0S", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_100": { "name": "OC_NoMonitoringOfGearOilFilter", "cn": "齿轮箱过滤器不监测阻塞情况", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_05_110": { "name": "SC_GearboxHeatingModeTimeout", "cn": "齿轮箱暖机超时", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tGearboxHeatingModeTimeout", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_001": { "name": "OC_GearFanLSForceMode", "cn": "齿轮箱低速风扇强制模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_002": { "name": "OC_GearFanLSManualMode", "cn": "齿轮箱低速风扇手动模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_003": { "name": "OC_GearFanHSForceMode", "cn": "齿轮箱高速风扇强制模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_004": { "name": "OC_GearFanHSManualMode", "cn": "齿轮箱高速风扇手动模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_005": { "name": "OC_GearOilHeaterForceMode", "cn": "齿轮箱油池加热器强制模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_006": { "name": "OC_GearOilHeaterManualMode", "cn": "齿轮箱油池加热器手动模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_007": { "name": "OC_GearOilFilterForceMode", "cn": "齿轮箱精滤器强制模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_008": { "name": "OC_GearOilFilterManualMode", "cn": "齿轮箱精滤器手动模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_009": { "name": "OC_GearOilPumpLSForceMode", "cn": "齿轮箱低速泵强制模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_010": { "name": "OC_GearOilPumpLSManualMode", "cn": "齿轮箱低速泵手动模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_011": { "name": "OC_GearOilPumpHSForceMode", "cn": "齿轮箱高速泵强制模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_012": { "name": "OC_GearOilPumpHSManualMode", "cn": "齿轮箱高速泵手动模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_013": { "name": "OC_GearboxFanHeaterForceMode", "cn": "齿轮箱风扇加热器强制模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_014": { "name": "OC_GearboxFanHeaterManualMode", "cn": "齿轮箱风扇加热器手动模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_015": { "name": "OC_GearboxOilPumpHeaterForceMode", "cn": "齿轮箱油泵加热器强制模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_016": { "name": "OC_GearboxOilPumpHeaterManualMode", "cn": "齿轮箱油泵加热器手动模式开启", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_017": { "name": "SC_GBXOilPumpMotorLS_Overload", "cn": "齿轮箱低速泵热继跳开", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_018": { "name": "SC_GBXOilPumpMotorHS_Overload", "cn": "齿轮箱高速泵热继跳开", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_020": { "name": "SC_GBXOilInletPressureTooLow", "cn": "齿轮箱油入口压力过低故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_021": { "name": "SC_GBXBearingIMS_GSGS_TempHigh", "cn": "齿轮箱中速轴(GSGS)温度高警告", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_022": { "name": "SC_GBXBearingIMS_GSGS_TempMax", "cn": "齿轮箱中速轴(GSGS)温度高故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_023": { "name": "SC_GBXBearingIMS_GSRS_TempHigh", "cn": "齿轮箱中速轴(GSRS)温度高警告", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_024": { "name": "SC_GBXBearingIMS_GSRS_TempMax", "cn": "齿轮箱中速轴(GSRS)温度高故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_025": { "name": "SC_GBXBearingIMS_RS_TempHigh", "cn": "齿轮箱中速轴(RS)温度高警告", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_026": { "name": "SC_GBXBearingIMS_RS_TempMax", "cn": "齿轮箱中速轴(RS)温度高故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_027": { "name": "SC_GBXBearingHSS_GSGS_TempHigh", "cn": "齿轮箱高速轴(GSGS)温度高警告", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_028": { "name": "SC_GBXBearingHSS_GSGS_TempMax", "cn": "齿轮箱高速轴(GSGS)温度高故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_029": { "name": "SC_GBXBearingHSS_GSRS_TempHigh", "cn": "齿轮箱高速轴(GSRS)温度高警告", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_030": { "name": "SC_GBXBearingHSS_GSRS_TempMax", "cn": "齿轮箱高速轴(GSRS)温度高故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_031": { "name": "SC_FaultAIAI_Gearbox_Bearing_IMS_GSGS_Temp", "cn": "齿轮箱中速轴(GSGS)PT100传感器故障", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_032": { "name": "SC_FaultAIAI_Gearbox_Bearing_IMS_GSRS_Temp", "cn": "齿轮箱中速轴(GSRS)PT100传感器故障", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_033": { "name": "SC_FaultAIAI_Gearbox_Bearing_IMS_RS_Temp", "cn": "齿轮箱中速轴(RS)PT100传感器故障", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_034": { "name": "SC_FaultAIAI_Gearbox_Bearing_HSS_GSGS_Temp", "cn": "齿轮箱高速轴(GSGS)PT100传感器故障", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_035": { "name": "SC_FaultAIAI_Gearbox_Bearing_HSS_GSRS_Temp", "cn": "齿轮箱高速轴(GSRS)PT100传感器故障", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_036": { "name": "SC_FaultAIAI_Gearbox_Bearing_HSS_RS_Temp", "cn": "齿轮箱高速轴(RS)PT100传感器故障", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_037": { "name": "SC_GBXBearingHSS_RS_TempHigh", "cn": "齿轮箱高速轴(RS)温度高警告", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_038": { "name": "SC_GBXBearingHSS_RS_TempMax", "cn": "齿轮箱高速轴(RS)温度高故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_039": { "name": "SC_GBXOfflineFitrationSystemMCB", "cn": "齿轮箱离线精滤器空开跳开", "subsystem": "Gearbox", "level": "10-其他", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_040": { "name": "SC_GearOilPumpMotorPreheaterMCB", "cn": "齿轮箱油泵加热器空开跳开", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_041": { "name": "SC_GearFilterPumpClogging", "cn": "齿轮箱油泵滤网堵塞", "subsystem": "GearBox", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_042": { "name": "OC_GearOilPumpValve_ON", "cn": "齿轮箱两位三通阀开启", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_043": { "name": "OC_GearOilPumpValveForceMode", "cn": "齿轮箱两位三通阀强制模式开启", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_044": { "name": "OC_GearOilPumpValveManualMode", "cn": "齿轮箱两位三通阀手动模式开启", "subsystem": "GearBox", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_036": { "name": "SC_MotorProtection_GenFanExternal", "cn": "机舱柜中发电机冷却风扇保护空开跳开", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_038": { "name": "SC_NacelleFuseGenSpaceHeater", "cn": "机舱柜中发电机空间加热器保护空开跳开", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_067": { "name": "SC_FaultInputPT100_GeneratorStatorU", "cn": "发电机定子U相绕组温度测量PT100传感器故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_02_069": { "name": "SC_FaultInputPT100_GeneratorStatorV", "cn": "发电机定子V相绕组温度测量PT100传感器故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_02_071": { "name": "SC_FaultInputPT100_GeneratorStatorW", "cn": "发电机定子W相绕组温度测量PT100传感器故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_02_073": { "name": "SC_FaultInputPT100_GeneratorBearingDE", "cn": "发电机驱动端轴承温度测量PT100传感器故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_02_074": { "name": "SC_FaultInputPT100_GeneratorBearingNDE", "cn": "发电机非驱动端轴承温度测量PT100传感器故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_02_101": { "name": "OC_GenFanExternal_ON", "cn": "发电机冷却风扇运行", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_103": { "name": "OC_GenSpaceHeaterON", "cn": "发电机空间加热器运行", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_128": { "name": "SC_MotorProtection_WCSG", "cn": "机舱柜中发电机水冷系统保护空开跳开", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_006": { "name": "SC_GeneratorBrushesWaste_Warning", "cn": "发电机碳刷磨损警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_007": { "name": "SC_GeneratorBrushesWaste_STOP", "cn": "发电机碳刷磨损故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tWarningToSTOP_GeneratorBrushes", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_012": { "name": "SC_GEN_StatorTempDiffExceedLimit", "cn": "发电机定子两相绕组温差大于设定值", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_013": { "name": "SC_TempGenStatorU_high", "cn": "发电机定子U相绕组温度过高警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_014": { "name": "SC_TempGenStatorU_low", "cn": "发电机定子U相绕组温度过低警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_015": { "name": "SC_TempGenStatorU_MAX", "cn": "发电机定子U相绕组温度过高故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_016": { "name": "SC_TempGenStatorU_min", "cn": "发电机定子U相绕组温度过低故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_017": { "name": "SC_TempGenStatorV_high", "cn": "发电机定子V相绕组温度过高警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_018": { "name": "SC_TempGenStatorV_low", "cn": "发电机定子V相绕组温度过低警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_019": { "name": "SC_TempGenStatorV_MAX", "cn": "发电机定子V相绕组温度过高故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_020": { "name": "SC_TempGenStatorV_MIN", "cn": "发电机定子V相绕组温度过低故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_021": { "name": "SC_TempGenStatorW_high", "cn": "发电机定子W相绕组温度过高警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_022": { "name": "SC_TempGenStatorW_low", "cn": "发电机定子W相绕组温度过低警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_023": { "name": "SC_TempGenStatorW_MAX", "cn": "发电机定子W相绕组温度过高故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_024": { "name": "SC_TempGenStatorW_MIN", "cn": "发电机定子W相绕组温度过低故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_025": { "name": "SC_RepFaultTempGenStator", "cn": "发电机定子绕组温度过高或过低警告重复出现", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_026": { "name": "SC_TempGenBearingDE_high", "cn": "发电机驱动端轴承温度过高警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_027": { "name": "SC_TempGenBearingDE_low", "cn": "发电机驱动端轴承温度过低警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_028": { "name": "SC_TempGenBearingDE_MAX", "cn": "发电机驱动端轴承温度过高故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_029": { "name": "SC_TempGenBearingDE_MIN", "cn": "发电机驱动端轴承温度过低故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_030": { "name": "SC_TempGenBearingNDE_high", "cn": "发电机非驱动端轴承温度过高警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_031": { "name": "SC_TempGenBearingNDE_low", "cn": "发电机非驱动端轴承温度过低警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_032": { "name": "SC_TempGenBearingNDE_MAX", "cn": "发电机非驱动端轴承温度过高故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_033": { "name": "SC_TempGenBearingNDE_MIN", "cn": "发电机非驱动端轴承温度过低故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_034": { "name": "SC_RepFaultTempGenBearing", "cn": "发电机轴承温度过高或过低警告重复出现", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_035": { "name": "SC_TempGenCoolingInletOrOutlet_high", "cn": "发电机冷却系统入口或出口温度过高警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_036": { "name": "SC_TempGenCoolingInletOrOutlet_low", "cn": "发电机冷却系统入口或出口温度过低警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_037": { "name": "SC_TempGenCoolingInletOrOutlet_MAX", "cn": "发电机冷却系统入口或出口温度过高故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_038": { "name": "SC_TempGenCoolingInletOrOutlet_MIN", "cn": "发电机冷却系统入口或出口温度过低故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "02_08_039": { "name": "SC_RepFaultTempGenCoolingInletOrOutlet", "cn": "发电机冷却系统入口或出口温度过高或过低警告重复出现", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_042": { "name": "SC_FaultPT100_GenCoolingInlet", "cn": "发电机冷却系统入口PT100传感器故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_043": { "name": "SC_FaultPT100_GenCoolingOutlet", "cn": "发电机冷却系统出口PT100传感器故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_100": { "name": "SC_TempGenStatorDewShortCircuit", "cn": "发电机定子温度低于露点温度", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "PAR_tGenStatorDewShortCircuit", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "04_06_001": { "name": "SC_TempGenStatorU1Error", "cn": "发电机U相温度信号1错误,报警不停机", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_002": { "name": "SC_TempGenStatorU2Error", "cn": "发电机U相温度信号2错误,报警不停机", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_003": { "name": "OC_TempGenStatorU1U2DiffMax", "cn": "发电机U相两PT100读书差值过大,报警不停机", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_005": { "name": "SC_TempGenStatorV1Error", "cn": "发电机V相温度信号1错误,报警不停机", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_006": { "name": "SC_TempGenStatorV2Error", "cn": "发电机V相温度信号2错误,报警不停机", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_007": { "name": "OC_TempGenStatorV1V2DiffMax", "cn": "发电机V相两PT100读书差值过大,报警不停机", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_009": { "name": "SC_TempGenStatorW1Error", "cn": "发电机W相温度信号1错误,报警不停机", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_010": { "name": "SC_TempGenStatorW2Error", "cn": "发电机W相温度信号2错误,报警不停机", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_011": { "name": "OC_TempGenStatorW1W2DiffMax", "cn": "发电机W相两PT100读书差值过大,报警不停机", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_013": { "name": "OC_GENFanControlManualMode", "cn": "发电机风扇控制进入手动模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_014": { "name": "OC_GENFanControlForcelMode", "cn": "发电机风扇控制进入强制模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_015": { "name": "OC_GENHeaterControlManualMode", "cn": "发电机加热器控制进入手动模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_016": { "name": "OC_GENHeaterControlForceMode", "cn": "发电机加热器控制进入强制模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_035": { "name": "SC_GENWaterLeakWarning", "cn": "发电机空水冷却器漏水警告", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_036": { "name": "SC_GENLubricationWarning", "cn": "发电机润滑系统警告", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_001": { "name": "SC_GenMaxPower10min", "cn": "发电机10分钟平均功率高于上限值", "subsystem": "GridMeasurement", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "5", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_08_002": { "name": "SC_GenMaxPower30s", "cn": "发电机30秒平均功率高于上限值", "subsystem": "GridMeasurement", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_003": { "name": "SC_GenMaxPower1s", "cn": "发电机1秒平均功率高于上限值", "subsystem": "GridMeasurement", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_08_004": { "name": "SC_RepFaultGenMaxPower10min", "cn": "发电机10分钟平均功率高于上限值故障重复出现", "subsystem": "GridMeasurement", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_009": { "name": "SC_DevicePowerUnequalGenPower", "cn": "外部设备测得发电机功率与变频器测得的差异大于设定值", "subsystem": "GridMeasurement", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_08_040": { "name": "SC_RepFaultGenMaxPower30s", "cn": "发电机30秒平均功率高于上限值故障重复出现", "subsystem": "GridMeasurement", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_041": { "name": "SC_RepFaultGenMaxPower1s", "cn": "发电机1秒平均功率高于上限值故障重复出现", "subsystem": "GridMeasurement", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_002": { "name": "SC_GridVoltageL1_high", "cn": "电网电压L1相超出上限值", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_003": { "name": "SC_GridVoltageL2_high", "cn": "电网电压L2相超出上限值", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_004": { "name": "SC_GridVoltageL3_high", "cn": "电网电压L3相超出上限值", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_005": { "name": "SC_RepFaultGridVoltageHigh", "cn": "电网电压过高故障重复出现", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_006": { "name": "SC_GridVoltageL1_low", "cn": "电网电压L1相超出下限值", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "PAR_tSetDelayForGridVoltageLow", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_007": { "name": "SC_GridVoltageL2_low", "cn": "电网电压L2相超出下限值", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "PAR_tSetDelayForGridVoltageLow", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_008": { "name": "SC_GridVoltageL3_low", "cn": "电网电压L3相超出下限值", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "PAR_tSetDelayForGridVoltageLow", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_009": { "name": "SC_RepFaultGridVoltageLow", "cn": "电网电压过低故障重复出现", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_010": { "name": "SC_GridFrequencyHigh", "cn": "电网频率过高", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "PAR_tSetDelayForFrequencyHigh", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms" ], "detectable_in_10min": false }, "03_04_011": { "name": "SC_GridFrequencyLow", "cn": "电网频率过低", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "PAR_tSetDelayForFrequencyLow", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms" ], "detectable_in_10min": false }, "03_04_012": { "name": "SC_RepFaultGridFrequency", "cn": "电网频率过高过低故障重复出现", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_018": { "name": "SC_GridLost_PowerFailure", "cn": "掉网故障", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_020": { "name": "SC_GridFrequencyMax", "cn": "电网频率高于上限值", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "PAR_tSetDelayForFrequencyMax", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms" ], "detectable_in_10min": false }, "03_04_021": { "name": "SC_GridFrequencyMin", "cn": "电网频率低于下限值", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "PAR_tSetDelayForFrequencyMin", "powerup_delay": "T#0s", "repeat_n": "10", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms" ], "detectable_in_10min": false }, "03_04_022": { "name": "OC_HVRT_Activated", "cn": "高电压穿越", "subsystem": "GridMeasurement", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#2m", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_200": { "name": "SC_GridCurrentAsymmetric", "cn": "电网三相电流不平衡", "subsystem": "GridMeasurement", "level": "180-电网故障", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#4s", "powerup_delay": "T#10s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_101": { "name": "OC_PowerAboveShutDown_10min", "cn": "发电机10分钟平均功率大于正常运行下限值", "subsystem": "GridMeasurement", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_09_102": { "name": "OC_PowerAboveShutDown_30s", "cn": "发电机30秒平均功率大于正常运行下限值", "subsystem": "GridMeasurement", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_041": { "name": "SC_MotorProtection_HydrPump", "cn": "机舱柜中液压站的液压泵保护空开跳开", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_090": { "name": "SC_FaultAI_HydraulicPressurePreCharge", "cn": "液压站储能罐压力传感器故障", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_091": { "name": "SC_FaultAI_HydraulicPressureSump", "cn": "液压站主回路压力传感器故障", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_092": { "name": "SC_FaultAI_HydraulicPressureBrake", "cn": "液压站刹车回路压力传感器故障", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_093": { "name": "SC_NacelleFuseHeaterHydrOil", "cn": "液压站油加热器熔丝开关跳开", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_094": { "name": "SC_AccumulatorPressure_High", "cn": "储能罐压力高", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_095": { "name": "SC_AccumulatorPressure_Low", "cn": "储能罐压力低", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_100": { "name": "OC_Valve1RotorBrake_ON", "cn": "机械刹车1号阀动作", "subsystem": "HSBrakeSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_109": { "name": "OC_HydrPump_ON", "cn": "液压站的液压泵运行", "subsystem": "HSBrakeSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_117": { "name": "OC_Valve2RotorBrake_ON", "cn": "机械刹车2号阀动作", "subsystem": "HSBrakeSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_118": { "name": "OC_Valve3RotorBrake_ON", "cn": "机械刹车3号阀动作", "subsystem": "HSBrakeSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_119": { "name": "OC_Valve4RotorBrake_ON", "cn": "机械刹车4号阀动作", "subsystem": "HSBrakeSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_07_001": { "name": "SC_MotorOverLoad_HydrPump", "cn": "液压泵电机过载", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_07_002": { "name": "SC_RotorBrakePadsWorn_Alarm", "cn": "机械刹车刹车盘磨损警告", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_07_003": { "name": "SC_RotorBrakePadsWorn_STOP", "cn": "机械刹车刹车盘磨损故障", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_07_005": { "name": "SC_RotorBrakeClosed", "cn": "机械刹车释放失灵", "subsystem": "HSBrakeSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_09_001": { "name": "SC_HydrPressureSystemMin_Warning", "cn": "液压系统刹车回路压力低于下限值警告", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#3m", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_09_003": { "name": "SC_HydrPressureSystemMin_STOP", "cn": "液压系统刹车回路压力低于下限值故障", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#3m", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_09_004": { "name": "SC_HydrSystemOilTemp_High", "cn": "液压系统刹车回路油温过高", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_09_005": { "name": "SC_HydrSystemPressMAX_STOP", "cn": "液压系统压力高于最大限值", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_09_006": { "name": "SC_HydrPressureSystemMainCircuitMin_Warning", "cn": "液压系统主回路压力低于下限值警告", "subsystem": "HSBrakeSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#3m", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_09_007": { "name": "SC_HydrPressureSystemMainCircuitMin_STOP", "cn": "液压系统主回路压力低于下限值故障", "subsystem": "HSBrakeSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#3m", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_09_008": { "name": "OC_ManualControlHydrPump", "cn": "液压泵手动控制模式", "subsystem": "HSBrakeSystem", "level": "10-其他", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_09_009": { "name": "OC_ForceControlHydrPump", "cn": "液压泵强制控制模式", "subsystem": "HSBrakeSystem", "level": "10-其他", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_09_010": { "name": "OC_RemControlHydrStart", "cn": "远程控制液压泵启动", "subsystem": "HSBrakeSystem", "level": "10-其他", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_09_011": { "name": "OC_ManualControlHSBrk", "cn": "手动控制液压刹车", "subsystem": "HSBrakeSystem", "level": "10-其他", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_09_017": { "name": "SC_HydrPumpTime_MAX", "cn": "液压泵运行时间过长", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "PAR_tDelayHydPumpTime_MAX", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_09_018": { "name": "SC_RepFault_HydrPumpTime_MAX", "cn": "液压泵运行时间过长故障重复出现", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_09_019": { "name": "SC_HydrPumpDecompressionTimeOut", "cn": "液压系统泄压超时", "subsystem": "HSBrakeSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tDelayForHydraulicsDecompression", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_09_020": { "name": "SC_HydrPumpCompressionLevel1TimeOut", "cn": "液压系统打压超时", "subsystem": "HSBrakeSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tDelayForHydraulicsCompressionLevel1", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_09_021": { "name": "SC_HydrPumpTooManyStarts", "cn": "液压泵开启过于频繁", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#30s", "repeat_n": "PAR_iNumberMaxStartHydPump", "repeat_period": "PAR_tIntervalMaxStartHydPump", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_09_024": { "name": "SC_UnfilHydraulicLoadManual", "cn": "用户手动释放液压系统压力", "subsystem": "HSBrakeSystem", "level": "30-待机", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_09_033": { "name": "SC_HYDSumpLevelLow", "cn": "液压站液位低", "subsystem": "HSBrakeSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "t#0S", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_005": { "name": "SC_SELFTEST_BrakeTestFailed", "cn": "刹车功能自检失败", "subsystem": "HSBrakeSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_002": { "name": "SC_LogErrorRingBufferStatuscodes", "cn": "状态字数据记录出错", "subsystem": "LogSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_011": { "name": "SC_LogErrorTrace", "cn": "Tracelog记录出错", "subsystem": "LogSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_001": { "name": "SC_Blade1_OnePitchSensorDefect", "cn": "1号桨出现角度传感器故障", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_003": { "name": "SC_PitchModeFeedbackError", "cn": "变桨系统状态反馈错误", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_004": { "name": "SC_Blade1_DetachEndPos91Failed", "cn": "1号桨叶从91度限位脱开失败", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_005": { "name": "SC_Blade2_DetachEndPos91Failed", "cn": "2号桨叶从91度限位脱开失败", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_006": { "name": "SC_Blade3_DetachEndPos91Failed", "cn": "3号桨叶从91度限位脱开失败", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_009": { "name": "SC_Blade1_EndPos95Deg", "cn": "1号桨的95度限位开关被撞开", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_011": { "name": "SC_Blade1_EndPos91Deg", "cn": "1号桨的91度限位开关被撞开", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_016": { "name": "SC_Blade1_PositionIncoherence", "cn": "1号桨实际值与给定值相差过大", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_021": { "name": "SC_Blade2_OnePitchSensorDefect", "cn": "2号桨出现角度传感器故障", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_029": { "name": "SC_Blade2_EndPos95Deg", "cn": "2号桨的95度限位开关被撞开", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_031": { "name": "SC_Blade2_EndPos91Deg", "cn": "2号桨的91度限位开关被撞开", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_036": { "name": "SC_Blade2_PositionIncoherence", "cn": "2号桨实际值与给定值相差过大", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_041": { "name": "SC_Blade3_OnePitchSensorDefect", "cn": "3号桨出现角度传感器故障", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_049": { "name": "SC_Blade3_EndPos95Deg", "cn": "3号桨的95度限位开关被撞开", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_051": { "name": "SC_Blade3_EndPos91Deg", "cn": "3号桨的91度限位开关被撞开", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_056": { "name": "SC_Blade3_PositionIncoherence", "cn": "3号桨实际值与给定值相差过大", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_063": { "name": "SC_AllBlades_EndPos91Or95", "cn": "1号,2号和3号桨都撞开91度或95度限位开关", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_064": { "name": "SC_PitchEmergencyMode", "cn": "变桨系统处在紧急模式", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_072": { "name": "SC_Pitch_SyncError_Limit1_5s", "cn": "两桨叶间的角度差大于设定值(相差1度持续10秒)", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "2", "repeat_period": "T#12h", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_073": { "name": "SC_Pitch_SyncError_Limit2_1s", "cn": "两桨叶间的角度差大于设定值(相差2度持续200毫秒)", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#200ms", "powerup_delay": "T#0s", "repeat_n": "2", "repeat_period": "T#12h", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_06_001": { "name": "SC_PitchNoFeedBackEFC_Signal", "cn": "主控制器没有收到来自变桨系统的EFC确认信号", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#150ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_018": { "name": "SC_NacelleFuse400VPitch", "cn": "机舱柜中变桨系统400V电源保护空开跳开", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#1s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_125": { "name": "OC_PitchBypassFeatherSwitchPitch_ON", "cn": "变桨系统96度限位开关的旁路信号设定发出", "subsystem": "Pitchsystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_014": { "name": "SC_RotorBoltLocked", "cn": "风机风轮锁被锁定", "subsystem": "RotorLock", "level": "210-维护", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_101": { "name": "OC_RotorBoltUnlocked", "cn": "风机风轮锁解锁", "subsystem": "RotorLock", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_01_001": { "name": "SC_SafetyChain_EmergencySTOP1nacelle", "cn": "机舱柜柜门急停按钮被拍下触发了紧急停机", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "210", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_01_002": { "name": "SC_SafetyChain_EmergencySTOP2nacelle", "cn": "机舱柜预留急停按钮节点断开触发了紧急停机", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "210", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_01_003": { "name": "SC_SafetyChain_VibrationSwitch", "cn": "PCH的振动过大继电器断开导致安全链断开", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#15s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_01_004": { "name": "SC_SafetyChain_OverspeedRelayTriggered", "cn": "过速继电器断开导致安全链断开", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_01_005": { "name": "SC_SafetyChain_SSDSwitch", "cn": "PCH的SSD开关断开导致安全链断开", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#15s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_01_006": { "name": "SC_SafetyChain_SSDMax", "cn": "PCH测得的SSD震动值高于设定值", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms" ], "detectable_in_10min": false }, "02_01_007": { "name": "SC_NacelleNoFeedBack24VOutHumanOrMachine", "cn": "机舱人员安全链或机器安全链没有反馈信号", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#120ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_01_101": { "name": "OC_SafetyChainResetFromNacelle", "cn": "机舱柜安全链复位按钮被按下对安全链进行复位", "subsystem": "SafetySystem", "level": "185-复位操作", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "185", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_015": { "name": "SC_NacelleOL24VOutputsSafetyChain", "cn": "机舱人工安全链或机舱机器安全链的24V电源开路", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_002": { "name": "SC_RotorOverSpeedLevel2", "cn": "风机低速端转速高于2级超速门限值", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_004": { "name": "SC_GeneratorOverSpeedLevel2", "cn": "发电机转速高于2级超速门限值", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_01_001": { "name": "SC_SafetyChainEmergencySTOP_TowerBase", "cn": "塔底柜急停按钮被拍下触发了紧急停机", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "210", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_01_003": { "name": "SC_TowerNoFeedBack24VOut_Human", "cn": "塔底人工安全链没有反馈信号", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#120ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_01_004": { "name": "SC_SafetyChainOpenedByConverter", "cn": "变频柜上的急停按钮被拍下触发了紧急停机", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_01_005": { "name": "SC_TowerNoFeedBack24VOut_Machine", "cn": "塔底机器安全链没有反馈信号", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#120ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_01_006": { "name": "SC_SafetyChainResetFromTowerBase", "cn": "塔底发出复位安全链命令", "subsystem": "SafetySystem", "level": "185-复位操作", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "185", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_01_007": { "name": "SC_SafetyChainResetRemoteOrTargetVISU", "cn": "远程发出复位安全链命令", "subsystem": "SafetySystem", "level": "185-复位操作", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "185", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_01_009": { "name": "SC_ResetSatetyChainStart", "cn": "系统复位", "subsystem": "SafetySystem", "level": "185-复位操作", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "185", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_01_010": { "name": "SC_SafetyChainOpenedByConverterOverPower", "cn": "变频器过功率触发安全链断开", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_013": { "name": "SC_TowerFuse24V_SafetyChain", "cn": "塔底柜安全链回路24V电源保护空开跳开", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_015": { "name": "SC_TowerOL24VOutputsSafetyChain", "cn": "塔底柜安全链24V电源开路", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_101": { "name": "OC_SafetyChainSingleShotRelayON", "cn": "塔底安全链单稳态继电器闭合", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_08_104": { "name": "OC_RESET_SAFETY_CHAIN", "cn": "风机接收到复位安全链指令", "subsystem": "SafetySystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_01_008": { "name": "SC_ResetStatusCodesStart", "cn": "复位状态字", "subsystem": "UserAccess", "level": "185-复位操作", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "185", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_08_003": { "name": "SC_ForceMajeure", "cn": "不可抗力停机", "subsystem": "UserAccess", "level": "240-不可抗力", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "240", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_08_004": { "name": "SC_STOP_RemoteOrServiceNotebook", "cn": "远程发出风机停机指令", "subsystem": "UserAccess", "level": "200-用户停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "200", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_08_006": { "name": "SC_OperatorStop", "cn": "操作员停机", "subsystem": "UserAccess", "level": "190-操作员停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "190", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_08_103": { "name": "OC_ManualTriggerTraceLog", "cn": "远程命令手动触发Tracelog生成", "subsystem": "UserAccess", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_300": { "name": "SC_STOP_ForGridLimitation", "cn": "电网容量原因停机", "subsystem": "WindFarm", "level": "180-电网故障", "reset_mode": "A", "type": "I", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_027": { "name": "SC_NoHeartBeat_WindparkCOM", "cn": "风场通讯故障", "subsystem": "WindFarm", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_007": { "name": "SC_NacelleFuseHeaterYawMotors", "cn": "偏航电机加热器保护空开跳开", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_023": { "name": "SC_NacelleMotorProtectionYawMotorsGroup", "cn": "机舱柜中偏航电机保护空开跳开", "subsystem": "YawSystem", "level": "50-偏航警告", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_046": { "name": "SC_MotorProtection_YawMotor1", "cn": "偏航系统1号电机热保护继电器触发", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_047": { "name": "SC_MotorProtection_YawMotor2", "cn": "偏航系统2号电机热保护继电器触发", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_048": { "name": "SC_MotorProtection_YawMotor3", "cn": "偏航系统3号电机热保护继电器触发", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_049": { "name": "SC_MotorProtection_YawMotor4", "cn": "偏航系统4号电机热保护继电器触发", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_078": { "name": "SC_NacelleFuseElectricalMotorBrakeYaw", "cn": "机舱柜中偏航电机抱闸的保护空开跳开", "subsystem": "YawSystem", "level": "50-偏航警告", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_088": { "name": "SC_FaultAI_YawPosition", "cn": "偏航系统位置传感器故障", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_110": { "name": "OC_HeaterYawMotors_ON", "cn": "偏航系统电机加热器设定打开", "subsystem": "YawSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_114": { "name": "OC_YawCW_ON", "cn": "偏航系统设定顺时针偏航", "subsystem": "YawSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_115": { "name": "OC_YawCCW_ON", "cn": "偏航系统设定逆时针偏航", "subsystem": "YawSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_116": { "name": "OC_OpenElectricalYawBrake_ON", "cn": "偏航系统电机抱闸设定打开", "subsystem": "YawSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_001": { "name": "SC_CableTwistMax_CW", "cn": "偏航系统顺时针2级限位开关被撞开", "subsystem": "YawSystem", "level": "50-偏航警告", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#500ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_002": { "name": "SC_CableTwistMax_CCW", "cn": "偏航系统逆时针2级限位开关被撞开", "subsystem": "YawSystem", "level": "50-偏航警告", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#500ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_008": { "name": "SC_YawSpeedTooSlow", "cn": "偏航系统速度过慢", "subsystem": "YawSystem", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "PAR_tYawSlowDelay", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_009": { "name": "SC_RepFault_YawSpeedTooSlow", "cn": "偏航系统速度过慢故障重复出现", "subsystem": "YawSystem", "level": "50-偏航警告", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_010": { "name": "SC_YawMotorTimeTooLong", "cn": "偏航系统电机运行时间过长", "subsystem": "YawSystem", "level": "50-偏航警告", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "PAR_tYawMotorTimeTooLong", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_011": { "name": "SC_STOP_ForBlockedYaw", "cn": "机舱与风向偏离过大,但偏航系统被禁止", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_012": { "name": "SC_YawPositionEncoderFault", "cn": "偏航系统位置编码器数值错误", "subsystem": "YawSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_013": { "name": "SC_YawAndWinddirDeviationTooHigh", "cn": "机舱与风向偏离过大", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_019": { "name": "SC_TempYawMotors1_MAX", "cn": "偏航系统1号电机PTC测温电阻触发", "subsystem": "YawSystem", "level": "50-偏航警告", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_020": { "name": "SC_TempYawMotors2_MAX", "cn": "偏航系统2号电机PTC测温电阻触发", "subsystem": "YawSystem", "level": "50-偏航警告", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_021": { "name": "SC_TempYawMotors3_MAX", "cn": "偏航系统3号电机PTC测温电阻触发", "subsystem": "YawSystem", "level": "50-偏航警告", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_022": { "name": "SC_TempYawMotors4_MAX", "cn": "偏航系统4号电机PTC测温电阻触发", "subsystem": "YawSystem", "level": "50-偏航警告", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_101": { "name": "SC_YawManualOperation", "cn": "偏航系统处于手动模式", "subsystem": "YawSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_102": { "name": "SC_StartRewindingLoopCables", "cn": "偏航系统开始自动解缆", "subsystem": "YawSystem", "level": "30-待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms", "_10min" ], "detectable_in_10min": false }, "02_10_105": { "name": "OC_RewindingLoopCablesActive", "cn": "偏航系统处于自动解缆模式", "subsystem": "YawSystem", "level": "30-待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_106": { "name": "SC_AutoGreaseError", "cn": "偏航系统自润滑设备故障", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_107": { "name": "SC_StartAutoGrease", "cn": "偏航系统开始自润滑", "subsystem": "YawSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#40s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_109": { "name": "SC_PreAutoGrease", "cn": "偏航系统自润滑预备", "subsystem": "YawSystem", "level": "30-待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#40s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms" ], "detectable_in_10min": false }, "02_10_110": { "name": "SC_AutoGreaseErrorBeka", "cn": "偏航系统自润滑设备故障", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#60s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_12_003": { "name": "SC_ManualYawBySoftware", "cn": "远程发出手工偏航命令", "subsystem": "YawSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_08_002": { "name": "SC_LimitSwitchCableTwistBridged", "cn": "旁路扭缆限位开关,重新得电后可以手动解缆", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_001": { "name": "SC_Transformer_Gasses_Pressure_Fault", "cn": "变压器油中溶解气体或压力过高", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_002": { "name": "SC_Transformer_Temp_High", "cn": "变压器温度高报警", "subsystem": "GCC", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_003": { "name": "SC_Transformer_Temp_VeryHigh", "cn": "变压器温度高故障", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_004": { "name": "SC_Switchgear_LineDisconnector_Open", "cn": "高压断路器无负荷开关分闸", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_005": { "name": "SC_Switchgear_EarthingContactor_Closed", "cn": "高压断路器接地开关合闸", "subsystem": "GCC", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_006": { "name": "SC_Switchgear_CB_Open", "cn": "开关设备打开", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_007": { "name": "SC_Switchgear_SF6_Pressure_Low", "cn": "SF6压力过低报警", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_009": { "name": "SC_Switchgear_MCB_Trip", "cn": "开关设备空开跳开", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_010": { "name": "SC_Switchgear_CB_Trip", "cn": "开关设备断路器跳开", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_011": { "name": "SC_Switchgear_CB_Opening_Failure", "cn": "开关设备打开失败", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_012": { "name": "SC_Switchgear_CB_Closing_Failure", "cn": "开关设备闭合失败", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_013": { "name": "OC_Switchgear_CB_Closing_Coil", "cn": "开关设备正在关闭", "subsystem": "GCC", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_014": { "name": "OC_Switchgear_CB_Opening_Coil", "cn": "开关设备正在打开", "subsystem": "GCC", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_015": { "name": "SC_Switchboard_690V_In_CB", "cn": "电网到690V的CB跳开", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_016": { "name": "SC_Switchboard_690V_AuxTrafo_CB", "cn": "690V到400V的变压器CB跳开", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_017": { "name": "SC_Switchboard_690V_ExtGen_CB", "cn": "外部发电机到690V的CB跳开", "subsystem": "GCC", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_018": { "name": "SC_Switchboard_690V_Group_CB", "cn": "至少一个690V的CB跳开", "subsystem": "GCC", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_019": { "name": "SC_Switchboard_400V_In_CB", "cn": "400V配电盘进电开关QTR2闭合", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_020": { "name": "SC_Switchboard_400V_UPS_In_CB", "cn": "400V配电盘QA12闭合", "subsystem": "GCC", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_021": { "name": "SC_Switchboard_400V_Group_CB", "cn": "400V配电盘(QA1-Q11+Q13-QA16)闭合", "subsystem": "GCC", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_022": { "name": "SC_Switchboard_400V_UPS_Out_CB", "cn": "UPS供电空开QUPS闭合", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_023": { "name": "SC_Switchboard_400V_UPS_Group_CB", "cn": "230V配电盘(QB1-QB8,QAUX)闭合", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_024": { "name": "SC_UPS_AC_Fail", "cn": "UPS进电故障", "subsystem": "GCC", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_025": { "name": "SC_UPS_Batt_Low", "cn": "UPS电池电压过低", "subsystem": "GCC", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_026": { "name": "SC_UPS_Batt_Low_Timeout", "cn": "UPS进电故障或电池电压过低超时", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "PAR_tUPS_Batt_Low_Shutdown_Time", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_029": { "name": "SC_GCC_Temp_High", "cn": "箱变温度过高报警", "subsystem": "GCC", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_030": { "name": "SC_GCC_Temp_VeryHigh", "cn": "箱变温度过高故障", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_031": { "name": "SC_GCC_Temp_Low", "cn": "箱变温度过低", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_032": { "name": "SC_FaultPT100_GCC_Temp1", "cn": "高压室内温度PT100故障", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_033": { "name": "SC_FaultPT100_Transformer_Temp", "cn": "箱变油温PT100故障", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_14_001": { "name": "SC_PowerMeasurementUnit_Fail", "cn": "电网测量设备故障", "subsystem": "GridMeasurement", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_034": { "name": "SC_UPS_Unhealthy", "cn": "UPS设备供电时间过短", "subsystem": "GCC", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_001": { "name": "SC_Safety_Loop_Open", "cn": "安全系统断开安全链", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_002": { "name": "SC_SafetyController_Not_Alive", "cn": "安全控制器失效", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_003": { "name": "SC_RotorSpeed_Unequal_SafetyController", "cn": "PLC的测得转速与安全控制器不同", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_004": { "name": "SC_SSD_Active", "cn": "SSD振动触发", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_005": { "name": "SC_Tower_Vibration_Active", "cn": "塔筒振动过大", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_006": { "name": "SC_SafetyChain_RotorOverSpeedError", "cn": "过速断开安全链", "subsystem": "SafetySystem", "level": "10-其他", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_007": { "name": "SC_SafetyChain_WTCAliveSignalError", "cn": "来自主控的频率信号丢失断开安全链", "subsystem": "SafetySystem", "level": "10-其他", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_008": { "name": "SC_SafetyChain_SpeedSensorError", "cn": "安全控制器测得转速与主控测得转速不匹配断开安全链", "subsystem": "SafetySystem", "level": "10-其他", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_009": { "name": "SC_SafetyChain_G_Sensor1_Error", "cn": "SSD振动断开安全链", "subsystem": "SafetySystem", "level": "10-其他", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_010": { "name": "SC_SafetyChain_G_Sensor2_Error", "cn": "塔筒振动断开安全链", "subsystem": "SafetySystem", "level": "10-其他", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_011": { "name": "SC_SafetyChain_EmergencyStopActivated", "cn": "急停断开安全链", "subsystem": "SafetySystem", "level": "10-其他", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_012": { "name": "SC_SafetyChain_YawLimitSwitchActivated", "cn": "偏航二级限位断开安全链", "subsystem": "SafetySystem", "level": "10-其他", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_013": { "name": "SC_SafetyChain_SafetyLoopFeedback_Error", "cn": "安全链复位失败", "subsystem": "SafetySystem", "level": "10-其他", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_015": { "name": "SC_SafetyChain_GeneratorOverSpeedError", "cn": "发电机过速断开安全链", "subsystem": "SafetySystem", "level": "10-其他", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_007": { "name": "SC_Blade1PitchAngleWrong91Pos", "cn": "1号桨叶91度限位触发位置故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_008": { "name": "SC_Blade2PitchAngleWrong91Pos", "cn": "2号桨叶91度限位触发位置故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_009": { "name": "SC_Blade3PitchAngleWrong91Pos", "cn": "3号桨叶91度限位触发位置故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_010": { "name": "SC_Blade1PitchAngleWrong95Pos", "cn": "1号桨叶95度限位触发位置故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_011": { "name": "SC_Blade2PitchAngleWrong95Pos", "cn": "2号桨叶95度限位触发位置故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_012": { "name": "SC_Blade3PitchAngleWrong95Pos", "cn": "3号桨叶95度限位触发位置故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_013": { "name": "SC_UndervoltageBackupAxis1", "cn": "1号桨叶后备电源电压过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_014": { "name": "SC_UndervoltageBackupAxis2", "cn": "2号桨叶后备电源电压过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_015": { "name": "SC_UndervoltageBackupAxis3", "cn": "3号桨叶后备电源电压过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_016": { "name": "SC_OvervoltageBackupAxis1", "cn": "1号桨叶后备电源电压过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_017": { "name": "SC_OvervoltageBackupAxis2", "cn": "2号桨叶后备电源电压过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_018": { "name": "SC_OvervoltageBackupAxis3", "cn": "3号桨叶后备电源电压过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_019": { "name": "SC_OvertemperatureAxisBox1", "cn": "1号轴控柜温度过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_020": { "name": "SC_OvertemperatureAxisBox2", "cn": "2号轴控柜温度过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_021": { "name": "SC_OvertemperatureAxisBox3", "cn": "3号轴控柜温度过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_022": { "name": "SC_UndertemperatureAxisBox1", "cn": "1号轴控柜温度过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_023": { "name": "SC_UndertemperatureAxisBox2", "cn": "2号轴控柜温度过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_024": { "name": "SC_UndertemperatureAxisBox3", "cn": "3号轴控柜温度过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_025": { "name": "SC_InfoTcuActive", "cn": "变桨系统发出内部信息", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_026": { "name": "SC_WarnTcuActive", "cn": "变桨系统发出报警信息", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_027": { "name": "SC_ErrTcuActive", "cn": "变桨系统发出故障信息", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_028": { "name": "SC_ErrPcuActive", "cn": "变桨系统出现内部故障", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_029": { "name": "SC_Blade1DCLinkVoltageNotOK", "cn": "1号桨直流母线电压不正常故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_030": { "name": "SC_Blade2DCLinkVoltageNotOK", "cn": "2号桨直流母线电压不正常故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_031": { "name": "SC_Blade3DCLinkVoltageNotOK", "cn": "3号桨直流母线电压不正常故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_032": { "name": "SC_24VSupplyAxis1", "cn": "1号桨叶24V电源故障", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_033": { "name": "SC_24VSupplyAxis2", "cn": "2号桨叶24V电源故障", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_034": { "name": "SC_24VSupplyAxis3", "cn": "3号桨叶24V电源故障", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_035": { "name": "SC_PitchCommunicationError", "cn": "主控制与变桨间的通讯故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_036": { "name": "OC_PitchCANCommunicationError", "cn": "主控与变桨之间的Canbus通讯故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "PAR_iNumberMaxPitchComError", "repeat_period": "PAR_tIntervalMaxPitchComError", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_037": { "name": "OC_PitchProfibusCommunicationError", "cn": "主控与变桨之间的无线Profibus通讯故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_038": { "name": "SC_PitchInLVRT", "cn": "变桨系统处于低电压穿越模式", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_039": { "name": "SC_OvertemperatureMotorAxis1", "cn": "1号变桨电机温度过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_040": { "name": "SC_OvertemperatureMotorAxis2", "cn": "2号变桨电机温度过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_041": { "name": "SC_OvertemperatureMotorAxis3", "cn": "3号变桨电机温度过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_042": { "name": "SC_UndertemperatureMotorAxis1", "cn": "1号变桨电机温度过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_043": { "name": "SC_UndertemperatureMotorAxis2", "cn": "2号变桨电机温度过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_044": { "name": "SC_UndertemperatureMotorAxis3", "cn": "3号变桨电机温度过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_045": { "name": "SC_PcuOpenSafetychain", "cn": "变桨系统断开EFC反馈信号", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#300ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_046": { "name": "SC_TcuOpenSafetychainFirst", "cn": "主控先断开了EFC信号", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_050": { "name": "SC_Axis1BackupMaintenanceRequired", "cn": "1号超级电容需要维护", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_051": { "name": "SC_Axis2BackupMaintenanceRequired", "cn": "2号超级电容需要维护", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_052": { "name": "SC_Axis3BackupMaintenanceRequired", "cn": "3号超级电容需要维护", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_053": { "name": "SC_Axis1backupTestWarning", "cn": "1号超级电容自检报警", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_054": { "name": "SC_Axis2backupTestWarning", "cn": "2号超级电容自检报警", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_055": { "name": "SC_Axis3backupTestWarning", "cn": "3号超级电容自检报警", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_056": { "name": "SC_Axis1backupTestError", "cn": "1号超级电容自检故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_057": { "name": "SC_Axis2backupTestError", "cn": "2号超级电容自检故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_058": { "name": "SC_Axis3backupTestError", "cn": "3号超级电容自检故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_060": { "name": "SC_LubricationFuseError", "cn": "变桨自润滑系统电源故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_061": { "name": "SC_LubricationSystemFault", "cn": "变桨自润滑系统故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_062": { "name": "SC_LubricationLowLevel", "cn": "变桨自润滑系统低油位故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_063": { "name": "SC_PitchHeatingMode", "cn": "变桨系统处于低温预加热模式", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_064": { "name": "SC_PitchMasterAxis1error", "cn": "1号桨叶的PM出现故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_065": { "name": "SC_PitchMasterAxis2error", "cn": "2号桨叶的PM出现故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_066": { "name": "SC_PitchMasterAxis3error", "cn": "3号桨叶的PM出现故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_067": { "name": "SC_CommunicationErrorPitchMasterAxis1", "cn": "1号桨叶的PM出现通讯故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_068": { "name": "SC_CommunicationErrorPitchMasterAxis2", "cn": "2号桨叶的PM出现通讯故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_069": { "name": "SC_CommunicationErrorPitchMasterAxis3", "cn": "3号桨叶的PM出现通讯故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_070": { "name": "SC_CommunicationErrorTCU", "cn": "变桨系统与主控的通讯出现故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_071": { "name": "SC_SafetyLineTCUOpen", "cn": "主控断开了EFC信号故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_072": { "name": "SC_PCUOpensSafetyLineFirst", "cn": "变桨系统先断开EFC信号", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_073": { "name": "SC_EmmergencyModeCommandFromTCUViaFieldbus", "cn": "主控发出了应急模式命令(信息)", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_074": { "name": "SC_SafetyRunStartedAutonomousByPitchmasterAxis1", "cn": "1号桨叶开始自主回桨", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_075": { "name": "SC_SafetyRunStartedAutonomousByPitchmasterAxis2", "cn": "2号桨叶开始自主回桨", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_076": { "name": "SC_SafetyRunStartedAutonomousByPitchmasterAxis3", "cn": "3号桨叶开始自主回桨", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_077": { "name": "SC_SafetyRunTimeout", "cn": "安全回桨超时故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_078": { "name": "SC_ContactorCyclesGridSupplyAxis", "cn": "400V进线主接触器2Q1的吸合次数超过了设计寿命报警", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_079": { "name": "SC_GridSupplyErrorAxis1", "cn": "1号桨叶400V电源故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_080": { "name": "SC_GridSupplyErrorAxis2", "cn": "2号桨叶400V电源故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_081": { "name": "SC_GridSupplyErrorAxis3", "cn": "3号桨叶400V电源故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_082": { "name": "SC_LVRTError", "cn": "LVRT故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_083": { "name": "SC_DClinkFuseErrorAxis1", "cn": "1号轴控柜内1F2失效故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_084": { "name": "SC_DClinkFuseErrorAxis2", "cn": "2号轴控柜内1F2失效故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_085": { "name": "SC_DClinkFuseErrorAxis3", "cn": "3号轴控柜内1F2失效故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_086": { "name": "SC_DiodeMonitoringAxis1", "cn": "1号轴控柜内1F1跳开故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_087": { "name": "SC_DiodeMonitoringAxis2", "cn": "1号轴控柜内1F1跳开故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_088": { "name": "SC_DiodeMonitoringAxis3", "cn": "1号轴控柜内1F1跳开故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_089": { "name": "SC_Mainsupplycontactoropen", "cn": "主接触器-2Q1断开", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_090": { "name": "SC_ErrorChargerAxis1", "cn": "1号轴控柜充电故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_091": { "name": "SC_ErrorChargerAxis2", "cn": "2号轴控柜充电故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_092": { "name": "SC_ErrorChargerAxis3", "cn": "3号轴控柜充电故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_093": { "name": "SC_ErrorHeatingAxis1", "cn": "1号轴控柜加热器故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_094": { "name": "SC_ErrorHeatingAxis2", "cn": "2号轴控柜加热器故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_095": { "name": "SC_ErrorHeatingAxis3", "cn": "3号轴控柜加热器故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_096": { "name": "SC_OvertemperatureBackupBox1", "cn": "1号后备电源柜温度过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_097": { "name": "SC_OvertemperatureBackupBox2", "cn": "2号后备电源柜温度过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_098": { "name": "SC_OvertemperatureBackupBox3", "cn": "3号后备电源柜温度过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_099": { "name": "SC_UndertemperatureBackupBox1", "cn": "1号后备电源柜温度过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_100": { "name": "SC_UndertemperatureBackupBox2", "cn": "2号后备电源柜温度过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_101": { "name": "SC_UndertemperatureBackupBox3", "cn": "3号后备电源柜温度过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_102": { "name": "SC_WireBreakTemperatureAxisBox1", "cn": "1号轴控柜温度传感器断线故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_103": { "name": "SC_WireBreakTemperatureAxisBox2", "cn": "2号轴控柜温度传感器断线故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_104": { "name": "SC_WireBreakTemperatureAxisBox3", "cn": "3号轴控柜温度传感器断线故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_105": { "name": "SC_WireBreakTemperatureBackupBox1", "cn": "1号后备电源柜温度传感器断线故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_106": { "name": "SC_WireBreakTemperatureBackupBox2", "cn": "2号后备电源柜温度传感器断线故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_107": { "name": "SC_WireBreakTemperatureBackupBox3", "cn": "3号后备电源柜温度传感器断线故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_108": { "name": "SC_WireBreakTemperatureMotorAxis1", "cn": "1号变桨电机温度传感器断线故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_109": { "name": "SC_WireBreakTemperatureMotorAxis2", "cn": "2号变桨电机温度传感器断线故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_110": { "name": "SC_WireBreakTemperatureMotorAxis3", "cn": "3号变桨电机温度传感器断线故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_111": { "name": "SC_WireBreakTemperatureHub", "cn": "轮毂温度传感器断线故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_112": { "name": "SC_ErrorFanPitchmasterAxis1", "cn": "1号PM的风扇故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_113": { "name": "SC_ErrorFanPitchmasterAxis2", "cn": "2号PM的风扇故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_114": { "name": "SC_ErrorFanPitchmasterAxis3", "cn": "3号PM的风扇故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_115": { "name": "SC_BackupSwitchopenaxis1", "cn": "1号轴控柜超级电容开关-1Q1断开", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_116": { "name": "SC_BackupSwitchopenaxis2", "cn": "2号轴控柜超级电容开关-1Q1断开", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_117": { "name": "SC_BackupSwitchopenaxis3", "cn": "3号轴控柜超级电容开关-1Q1断开", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_118": { "name": "SC_ContactorCyclesDCSupplyAxis1", "cn": "1号轴控柜内接触器3Q1的吸合次数超过了设计寿命报警", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_119": { "name": "SC_ContactorCyclesDCSupplyAxis2", "cn": "2号轴控柜内接触器3Q1的吸合次数超过了设计寿命报警", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_120": { "name": "SC_ContactorCyclesDCSupplyAxis3", "cn": "3号轴控柜内接触器3Q1的吸合次数超过了设计寿命报警", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_123": { "name": "SC_OvertemperatureLBA", "cn": "中心柜温度过高故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_124": { "name": "SC_UndertemperatureLBA", "cn": "中心柜温度过低故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_125": { "name": "SC_WireBreakTemperatureLBA", "cn": "中心柜温度传感器断线故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_126": { "name": "SC_OvertemperatureHub", "cn": "轮毂温度过高警告", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_127": { "name": "SC_UndertemperatureHub", "cn": "轮毂温度过低警告", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1S", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_128": { "name": "SC_HVRTdetected", "cn": "HVRT level1 警告", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_129": { "name": "SC_HVRTLevel2detected", "cn": "HVRT level2 警告", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_130": { "name": "SC_HVRTLevel2toolong", "cn": "HVRT 故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_131": { "name": "SC_PitchInReboot", "cn": "远程重启变桨系统", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "A", "type": "I", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_053": { "name": "SC_FaultInputPT100_Nacelle", "cn": "机舱温度测量PT100传感器故障", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_02_077": { "name": "SC_FaultInputPT100_Outdoor", "cn": "舱外环境温度测量PT100传感器故障", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_02_089": { "name": "SC_FaultAI_SensorWindDirection", "cn": "风向标故障", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_111": { "name": "OC_HeaterWindSensors_ON", "cn": "风速仪和风向标的加热器开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_03_001": { "name": "SC_TempNacelle_high", "cn": "机舱温度过高警告", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_03_002": { "name": "SC_TempNacelle_low", "cn": "机舱温度过低警告", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_03_003": { "name": "SC_TempNacelle_max", "cn": "机舱温度过高故障", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_03_004": { "name": "SC_TempNacelle_min", "cn": "机舱温度过低故障", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_03_005": { "name": "SC_RepFaultTempNacelle", "cn": "机舱温度过高或过低警告重复出现", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_018": { "name": "SC_VibrationOmniDirectionLevel1", "cn": "塔架水平方向的加速度高于1级振动门限值", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#2s", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_019": { "name": "SC_VibrationOmniDirectionLevel2", "cn": "塔架水平方向的加速度高于2级振动门限值", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#2s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_020": { "name": "SC_RepFaultVibrationYAxis", "cn": "阵风过大保护性停机", "subsystem": "NacelleSystem", "level": "139-大风停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "139", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_021": { "name": "SC_VibrationForeaftDirection1", "cn": "塔架前后方向的加速度高于1级振动门限值", "subsystem": "NacelleSystem", "level": "30-待机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#2s", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_022": { "name": "SC_VibrationForeaftDirection2", "cn": "塔架前后方向的加速度高于2级振动门限值", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#2s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_023": { "name": "SC_RepFaultVibrationZAxis", "cn": "阵风过大保护性停机", "subsystem": "NacelleSystem", "level": "139-大风停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "139", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_024": { "name": "OC_VibrationOmniDirection", "cn": "塔架水平方向的加速度超限", "subsystem": "NacelleSystem", "level": "30-待机", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_025": { "name": "OC_VibrationForeaftDirection", "cn": "塔架前后方向的加速度超限", "subsystem": "NacelleSystem", "level": "30-待机", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_10_111": { "name": "SC_BlockYawForVibrationHigh", "cn": "前后方向振动值过大禁止偏航一分钟", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_11_001": { "name": "SC_ConstantSignalVane1", "cn": "风向标静止不动", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_11_008": { "name": "SC_ConstantSignalAnemometer1", "cn": "风速仪静止不动", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_11_009": { "name": "OC_ConstantWindVaneReadings", "cn": "风向标读数不变", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#20s", "powerup_delay": "T#5m", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_11_010": { "name": "OC_RestartWindVane", "cn": "重启风向标", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "2", "repeat_period": "T#1m", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_11_016": { "name": "SC_TempOutdoor_high", "cn": "舱外环境温度过高警告", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_11_017": { "name": "SC_TempOutdoor_low", "cn": "舱外环境温度过低警告", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_11_018": { "name": "SC_TempOutdoor_MAX", "cn": "舱外环境温度过高故障", "subsystem": "NacelleSystem", "level": "159-环境温度停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "159", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_11_019": { "name": "SC_TempOutdoor_MIN", "cn": "舱外环境温度过低故障", "subsystem": "NacelleSystem", "level": "159-环境温度停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "159", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_11_020": { "name": "SC_RepFault_TempOutdoor", "cn": "舱外环境温度过高或过低警告重复出现", "subsystem": "NacelleSystem", "level": "159-环境温度停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "1", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "159", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_11_101": { "name": "SC_ShutDownWindspeed_1sMax", "cn": "1秒平均风速高于上限值", "subsystem": "NacelleSystem", "level": "139-大风停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "139", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_11_102": { "name": "SC_ShutDownWindspeed_30sMax", "cn": "30秒平均风速高于上限值", "subsystem": "NacelleSystem", "level": "139-大风停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "139", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_11_103": { "name": "SC_ShutDownWindspeed_10minMax", "cn": "10分钟平均风速高于上限值", "subsystem": "NacelleSystem", "level": "139-大风停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "139", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_11_104": { "name": "OC_WaitingForWind", "cn": "10分钟平均风速低于启动风速", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_11_105": { "name": "OC_MeanWindSpeedAboveActivatingYaw", "cn": "风速条件允许偏航系统进行对风", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_11_106": { "name": "OC_MeanWindSpeedAboveRestartMaxWind", "cn": "1秒平均风速过高", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_11_107": { "name": "OC_NoMonitoringWindSensors", "cn": "风速过低,不对风速仪和风向标进行监测", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_11_109": { "name": "SC_ShutDownWindspeed_10minMin", "cn": "风速过低停机", "subsystem": "NacelleSystem", "level": "129-小风停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "129", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_11_112": { "name": "OC_MeanWindSpeedAboveCableUnwindingOK", "cn": "风速过高,不能自动解缆", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_11_113": { "name": "SC_WindSpeedTooHighForManualModeOrService", "cn": "风速过高,不能手动变桨和手动操作风机", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_14_001": { "name": "SC_PCH_BadDataDetected", "cn": "主控系统读得的PCH震动值长时间不刷新", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#30s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_14_002": { "name": "OC_PCHScaleFactorEqualZero", "cn": "PCH读取的振动值系数为0", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_03_101": { "name": "SC_FaultInputPT100_Cable", "cn": "电缆温度PT100故障", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_03_102": { "name": "OC_CableOverTempToDisableOverPower", "cn": "当电缆温度超过某个值后,则限制超发功能", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_004": { "name": "SC_SELFTEST_PCHTestFailed", "cn": "PCH自检失败", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_001": { "name": "SC_NacelleFireAlarm", "cn": "机舱火警系统触发", "subsystem": "NacelleSystem", "level": "175-故障停机(强)", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_002": { "name": "SC_NacelleFireAlarmSystemDefect", "cn": "机舱火警系统失效", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_003": { "name": "SC_FTWindSensorFail", "cn": "FT风速风向传感器故障", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_004": { "name": "SC_FTHeaterMCB", "cn": "FT加热器空开跳开", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_005": { "name": "SC_AnalogWindDirectionHeaterMCB", "cn": "风向标加热器空开跳开", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_006": { "name": "SC_AnalogWindSpeedHeaterMCB", "cn": "风速仪加热器空开跳开", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_008": { "name": "SC_MaxDeviationWindDirection", "cn": "不同传感器测得风向偏差过大", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#20s", "powerup_delay": "T#1m", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "04_09_009": { "name": "SC_MaxDeviationWindSpeed", "cn": "不同传感器测得风速偏差过大", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#20s", "powerup_delay": "T#1m", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_010": { "name": "SC_NacelleHumidityHigh", "cn": "机舱湿度过大", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_011": { "name": "SC_ForceMode_NacelleOutletDamper", "cn": "机舱出口气流调节器强制模式开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_012": { "name": "SC_NacelleOutletDamperMCB", "cn": "机舱出口气流调节器空开跳开", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_013": { "name": "OC_NacelleOutletDamper_ON", "cn": "机舱出口气流调节器打开", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_014": { "name": "SC_ManualMode_NacelleOutletDamper", "cn": "机舱出口气流调节器手动模式开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_015": { "name": "SC_ForceMode_NacelleOutletFan", "cn": "机舱出口风扇强制模式开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_016": { "name": "SC_NacelleOutletFan1MCB", "cn": "机舱出口风扇1空开跳开", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_017": { "name": "SC_NacelleOutletFan1Overload", "cn": "机舱出口风扇1热继跳开", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_018": { "name": "SC_NacelleOutletFan2MCB", "cn": "机舱出口风扇2空开跳开", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_019": { "name": "SC_NacelleOutletFan2Overload", "cn": "机舱出口风扇2热继跳开", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_020": { "name": "OC_NacelleOutletFan1_ON", "cn": "机舱出口风扇1开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_021": { "name": "OC_NacelleOutletFan2_ON", "cn": "机舱出口风扇2开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_022": { "name": "SC_ManualMode_NacelleOutletFan", "cn": "机舱出口风扇手动模式开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_023": { "name": "SC_ForceMode_NacelleInletDamper", "cn": "机舱入口气流调节器强制模式开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_024": { "name": "SC_NacelleInletDamperMCB", "cn": "机舱入口气流调节器空开跳开", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_025": { "name": "OC_NacelleInletDamper_ON", "cn": "机舱入口气流调节器打开", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_026": { "name": "SC_ManualMode_NacelleInletDamper", "cn": "机舱入口气流调节器手动模式开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_027": { "name": "SC_ForceMode_NacelleHeater", "cn": "机舱加热器强制模式开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_028": { "name": "SC_NacelleHeaterMCB", "cn": "机舱加热器空开跳开", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_029": { "name": "OC_NacelleHeater_ON", "cn": "机舱加热器开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_030": { "name": "SC_ManualMode_NacelleHeater", "cn": "机舱加热器手动模式开启", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_031": { "name": "SC_AviationLightMCB", "cn": "航空灯空开跳开", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_032": { "name": "SC_AviationLightStatus", "cn": "航空灯故障", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_009": { "name": "SC_TempCabinetNacelle_high", "cn": "机舱控制柜温度过高警告", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_02_010": { "name": "SC_TempCabinetNacelle_low", "cn": "机舱控制柜温度过低警告", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_02_011": { "name": "SC_TempCabinetNacelle_MAX", "cn": "机舱控制柜温度过高故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_02_012": { "name": "SC_TempCabinetNacelle_MIN", "cn": "机舱控制柜温度过低故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_02_013": { "name": "SC_RepFaultTempCabinetNacelle", "cn": "机舱控制柜温度过高或过低警告重复出现", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_052": { "name": "SC_FaultInputPT100_CabinetNacelle", "cn": "机舱控制柜温度测量PT100传感器故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "02_12_001": { "name": "SC_ManualSTOP_NacelleOrTowerBase", "cn": "机舱或塔底发出停机命令", "subsystem": "Cabinet", "level": "200-用户停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "200", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_002": { "name": "SC_TowerBaseUPS_Alarm", "cn": "变频柜230V UPS警告", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#60s", "powerup_delay": "T#1s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_023": { "name": "SC_FaultInputPT100_TempTowerBase", "cn": "塔底温度测量PT100传感器故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_02_024": { "name": "SC_TempCabinetTowerBase_high", "cn": "塔底控制柜温度过高警告", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_02_025": { "name": "SC_TempCabinetTowerBase_low", "cn": "塔底控制柜温度过低警告", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_02_026": { "name": "SC_TempCabinetTowerBase_MAX", "cn": "塔底控制柜温度过高故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_02_027": { "name": "SC_TempCabinetTowerBase_MIN", "cn": "塔底控制柜温度过低故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_02_028": { "name": "SC_RepFaultTempCabinetTowerBase", "cn": "塔底控制柜温度过高或过低警告重复出现", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_039": { "name": "SC_FaultInputPT100_TempCabinetTowerBase", "cn": "塔底控制柜温度测量PT100传感器故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_08_001": { "name": "SC_TurbineInServiceTowerBase", "cn": "塔底柜维护开关打开,要求风机进入维护模式", "subsystem": "Cabinet", "level": "210-维护", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_03_001": { "name": "SC_RotorLock_Pin1NotUnlocked", "cn": "风轮锁1不在退出位置", "subsystem": "RotorLock", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_03_002": { "name": "SC_RotorLock_Pin2NotUnlocked", "cn": "风轮锁2不在退出位置", "subsystem": "RotorLock", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_03_003": { "name": "SC_RotorLock_PushOutPressureOK", "cn": "风轮锁退出压力正常", "subsystem": "RotorLock", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_03_004": { "name": "SC_RotorLock_PinPositionError", "cn": "在空转或发电状态,风轮锁不在退出位置", "subsystem": "RotorLock", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_03_005": { "name": "SC_RotorLock_PushOutPressureLowWarning", "cn": "在空转或发电状态,风轮锁退出压力过低报警", "subsystem": "RotorLock", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_03_006": { "name": "SC_RotorLock_PushOutPressureLowError", "cn": "在空转或发电状态,风轮锁退出压力过低停机", "subsystem": "RotorLock", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_03_007": { "name": "SC_RotorLock_PushOutPressureSensorFault", "cn": "风轮锁退出压力传感器故障", "subsystem": "RotorLock", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_001": { "name": "SC_CC_690V_Supply_Fault", "cn": "变频器690V供电故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_002": { "name": "SC_CC_400V_Supply_Fault", "cn": "变频器400V供电故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_003": { "name": "SC_CC_230V_UPS_Supply_Fault", "cn": "变频器230V UPS供电故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_004": { "name": "SC_CC_Temp_High", "cn": "变频柜温度高报警", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_005": { "name": "SC_CC_Temp_VeryHigh", "cn": "变频柜温度高故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_006": { "name": "SC_CC_Temp_Low", "cn": "变频柜温度低故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_007": { "name": "SC_CC_AirCon_Fault", "cn": "变频柜空调故障", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#1s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_008": { "name": "SC_CC_SmokeDetect", "cn": "变频柜中烟雾报警器触发", "subsystem": "ConverterContainer", "level": "175-故障停机(强)", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#1s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_009": { "name": "SC_FaultInputPT100_CC_One", "cn": "变频柜中一个PT100故障", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_010": { "name": "SC_FaultInputPT100_CC_Both", "cn": "变频柜中两个PT100故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_011": { "name": "SC_Heater_Supply_Coverter1_MCB", "cn": "变频器1的加热器供电空开跳开", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_012": { "name": "SC_Heater_Supply_Coverter2_MCB", "cn": "变频器2的加热器供电空开跳开", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_013": { "name": "SC_Converters_Alarm", "cn": "变频器报告警告", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_014": { "name": "SC_Converter_BrakeChopperActive", "cn": "变频器Chopper开启", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_015": { "name": "SC_Converter_DCLinkChargeTimeOut", "cn": "变频器直流母线充电超时", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "PAR_tCVT_DCLinkChargeTimeout", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_013": { "name": "SC_ReturnOfGrid_RideThrough", "cn": "LVRT模式下电网恢复", "subsystem": "TurbineStateMachine", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_014": { "name": "SC_FaultRestartAfterReturnOfGrid", "cn": "LVRT模式下电网恢复后风机重新启动", "subsystem": "TurbineStateMachine", "level": "180-电网故障", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "180", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_017": { "name": "SC_VoltageOutOfRange_RideThrough", "cn": "LVRT模式下电网电压超限", "subsystem": "TurbineStateMachine", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_321": { "name": "OC_UserLimitPower", "cn": "用户限功率", "subsystem": "TurbineStateMachine", "level": "99-用户限功率发电", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "99", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_04_322": { "name": "OC_SystemLimitPower", "cn": "主控限功率", "subsystem": "TurbineStateMachine", "level": "89-主控限功率发电", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "89", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_136": { "name": "OC_ShutDownOutput", "cn": "系统故障时关闭输出", "subsystem": "TurbineStateMachine", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_07_005": { "name": "SC_TestBrakeProgram50", "cn": "Scada发出50#刹车测试指令", "subsystem": "TurbineStateMachine", "level": "210-维护", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_07_006": { "name": "SC_TestBrakeProgram51", "cn": "Scada发出51#刹车测试指令", "subsystem": "TurbineStateMachine", "level": "210-维护", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_07_007": { "name": "SC_TestBrakeProgram100", "cn": "Scada发出100#刹车测试指令", "subsystem": "TurbineStateMachine", "level": "210-维护", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_07_008": { "name": "SC_TestBrakeProgram198", "cn": "Scada发出198#刹车测试指令", "subsystem": "TurbineStateMachine", "level": "210-维护", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_07_011": { "name": "SC_TestBrakeProgram200", "cn": "Scada发出150#刹车测试指令", "subsystem": "TurbineStateMachine", "level": "210-维护", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_001": { "name": "SC_TURBINE_AVAILABLE", "cn": "风机正常运行", "subsystem": "TurbineStateMachine", "level": "69-启动", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#5s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "69", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_008": { "name": "OC_ManualTurbineControlActive", "cn": "Scada发出手动控制风机指令", "subsystem": "TurbineStateMachine", "level": "210-维护", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_011": { "name": "SC_TimeOut_BP51", "cn": "51号刹车模式时间过长", "subsystem": "TurbineStateMachine", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeOutBrakeMode51", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms", "_1sec" ], "detectable_in_10min": false }, "03_09_012": { "name": "SC_TimeOut_BP100", "cn": "100号刹车模式时间过长", "subsystem": "TurbineStateMachine", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeOutBrakeMode100", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms", "_1sec" ], "detectable_in_10min": false }, "03_09_013": { "name": "SC_TimeOut_BP50", "cn": "50号刹车模式时间过长", "subsystem": "TurbineStateMachine", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeOutBrakeMode50", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_105": { "name": "OC_DelayRestartActive", "cn": "风机处于故障后允许复位延迟过程中", "subsystem": "TurbineStateMachine", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_110": { "name": "OC_ActivatePitchMove", "cn": "变桨自润滑启用", "subsystem": "TurbineStateMachine", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "PAR_tMaxTimeWithoutPitchMove", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms" ], "detectable_in_10min": false }, "03_09_111": { "name": "SC_ForceSelfTestEvery720h", "cn": "720小时强制自检", "subsystem": "TurbineStateMachine", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#10s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_114": { "name": "SC_TowerResonanceModeTimeOut", "cn": "升速过程中处于共振区时间过长", "subsystem": "TurbineStateMachine", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "PAR_tResonanceModeTimeMax", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_120": { "name": "OC_TurbineHeatingMode", "cn": "风机暖机模式", "subsystem": "TurbineStateMachine", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_001": { "name": "SC_YawLubricationGreasePressureHigh", "cn": "偏航润滑油脂压力过高", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_002": { "name": "SC_YawLubricationGreaseLevelLow", "cn": "偏航润滑油脂油位过低", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_003": { "name": "SC_MotorProtection_YawMotor5", "cn": "偏航系统5号电机热保护继电器触发", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_004": { "name": "SC_MotorProtection_YawMotor6", "cn": "偏航系统6号电机热保护继电器触发", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_005": { "name": "SC_Yaw_Motor_1_MCB", "cn": "1#偏航电机空开跳开", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_006": { "name": "SC_Yaw_Motor_2_MCB", "cn": "2#偏航电机空开跳开", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_007": { "name": "SC_Yaw_Motor_3_MCB", "cn": "3#偏航电机空开跳开", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_008": { "name": "SC_Yaw_Motor_4_MCB", "cn": "4#偏航电机空开跳开", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_009": { "name": "SC_Yaw_Motor_5_MCB", "cn": "5#偏航电机空开跳开", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_010": { "name": "SC_Yaw_Motor_6_MCB", "cn": "6#偏航电机空开跳开", "subsystem": "YawSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_011": { "name": "SC_Yaw_Stopped_MaxNum_Failure", "cn": "偏航电机失效数量过大", "subsystem": "YawSystem", "level": "50-偏航警告", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "50", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_012": { "name": "SC_YawMotorsHeaterForceMode", "cn": "偏航加热器强制模式开启", "subsystem": "YawSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_013": { "name": "SC_YawMotorsHeaterManualMode", "cn": "偏航加热器手动模式开启", "subsystem": "YawSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_014": { "name": "SC_YawForceMode", "cn": "偏航强制模式开启", "subsystem": "YawSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_016": { "name": "SC_Converter_MasterSlaveConfigureNotFinished", "cn": "变频器主从配置没有完成", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_001": { "name": "SC_TimeOut_Selftest1", "cn": "自检1运行超时", "subsystem": "TurbineStateMachine", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeoutSelftest1", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_002": { "name": "SC_TimeOut_Selftest2", "cn": "自检2运行超时", "subsystem": "TurbineStateMachine", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeoutSelftest2", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_003": { "name": "SC_TimeOut_Selftest3", "cn": "自检3运行超时", "subsystem": "TurbineStateMachine", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeoutSelftest3", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_004": { "name": "SC_TimeOut_Selftest4", "cn": "自检4运行超时", "subsystem": "TurbineStateMachine", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeoutSelftest4", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_005": { "name": "SC_TimeOut_StartMode", "cn": "启动模式运行超时", "subsystem": "TurbineStateMachine", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeoutStartMode", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_006": { "name": "SC_TimeOut_CutInMode", "cn": "切入并网超时", "subsystem": "TurbineStateMachine", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeoutCutInMode", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_007": { "name": "SC_NacellePositionInSector1", "cn": "机舱位置处在扇区1", "subsystem": "TurbineStateMachine", "level": "79-无限制发电", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_008": { "name": "SC_NacellePositionInSector2", "cn": "机舱位置处在扇区2", "subsystem": "TurbineStateMachine", "level": "79-无限制发电", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_009": { "name": "SC_NacellePositionInSector3", "cn": "机舱位置处在扇区3", "subsystem": "TurbineStateMachine", "level": "79-无限制发电", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_010": { "name": "SC_NacellePositionInSector4", "cn": "机舱位置处在扇区4", "subsystem": "TurbineStateMachine", "level": "79-无限制发电", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_132": { "name": "SC_Blade1PositionCheckAlarm", "cn": "1号桨叶角度检查偏差过大警告", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_133": { "name": "SC_Blade2PositionCheckAlarm", "cn": "2号桨叶角度检查偏差过大警告", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_134": { "name": "SC_Blade3PositionCheckAlarm", "cn": "3号桨叶角度检查偏差过大警告", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "165", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_135": { "name": "SC_Pitch230VLineSupplyCBTrip", "cn": "230V信号线供电CB跳开", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_136": { "name": "SC_PitchBackUpTest", "cn": "远程设定变桨后备电源自检测试", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_137": { "name": "SC_PitchForceMode", "cn": "变桨系统处于强制模式,桨角可任意给定", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_138": { "name": "SC_PitchEncoderSet", "cn": "变桨系统设置编码器", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_139": { "name": "SC_PitchCANComErrorTooFrequent", "cn": "变桨CAN通讯报警频繁", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_020": { "name": "SC_HarddiskOverflow", "cn": "CF卡中的Tracelog过多", "subsystem": "LogSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_008": { "name": "SC_DivisionByZero", "cn": "除数为零错误", "subsystem": "PLCSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_009": { "name": "SC_MaxCycleTimeMainPLCTask", "cn": "PLC-Task1任务执行超时", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_012": { "name": "SC_MaxCycleTimeFASTTask", "cn": "PLC-Task2任务执行超时", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_008": { "name": "SC_MaxCycleTimeTask3", "cn": "PLC-Task3任务执行超时", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_013": { "name": "SC_RepFaultMaxCycleTimeTask", "cn": "PLC-Task1或Task2或Task3任务执行超时故障重复出现", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_123": { "name": "OC_PLCPowerUp", "cn": "PLC正在启动中", "subsystem": "PLCSystem", "level": "30-待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_124": { "name": "SC_UpdateModeON", "cn": "远程命令PLC程序升级", "subsystem": "PLCSystem", "level": "250-升级", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "250", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_126": { "name": "SC_RebootPLC", "cn": "远程命令主控制器重启(操作系统,TwinCAT,应用程序)", "subsystem": "PLCSystem", "level": "250-升级", "reset_mode": "M", "type": "F", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "250", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_133": { "name": "SC_ParOutOfRange", "cn": "参数设定超限", "subsystem": "PLCSystem", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_135": { "name": "OC_UpdateModeReady", "cn": "升级模式准备就绪", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": [ "_100ms", "_1sec" ], "detectable_in_10min": false }, "03_06_018": { "name": "SC_InterruptionEtherCAT", "cn": "EtherCAT通讯故障", "subsystem": "PLCSystem", "level": "175-故障停机(强)", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tSetDelayForEtherCAT", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "100", "bp_runtime_2015": "175", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_035": { "name": "OC_NoCOM_EtherCAT", "cn": "EtherCAT通讯出错", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_031": { "name": "SC_RepFault_COM_BKEK_TurbineInternal", "cn": "塔底EK1100,机舱EK1100或BK1250通讯故障多次出现", "subsystem": "PLCSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_030": { "name": "SC_RestoreStatisticsFileFailed", "cn": "读取统计量参数文件失败", "subsystem": "PLCSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_031": { "name": "SC_RestoreUniqueParFileFailed", "cn": "读取个性化参数文件失败", "subsystem": "PLCSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_032": { "name": "SC_RestoreGoldenParFileFailed", "cn": "读取通用性参数文件失败", "subsystem": "PLCSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_033": { "name": "SC_StoreStatisticsFileFailed", "cn": "存储统计量参数文件失败", "subsystem": "PLCSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_034": { "name": "SC_StoreUniqueParFileFailed", "cn": "存储个性化参数文件失败", "subsystem": "PLCSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_035": { "name": "SC_StoreGoldenParFileFailed", "cn": "存储通用性参数文件失败", "subsystem": "PLCSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_017": { "name": "SC_NoCOM_EK1501Nacelle", "cn": "机舱EK1501通讯故障", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_018": { "name": "SC_NoCOM_BK1120Nacelle", "cn": "机舱BK1120通讯故障", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_021": { "name": "SC_NoCOM_EK1252Nacelle", "cn": "机舱EK1252通讯故障", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_024": { "name": "SC_NoCOM_BK1250TowerBase", "cn": "塔底BK1250通讯故障", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_026": { "name": "SC_NoCOM_EK1501TowerBase", "cn": "塔底EK1501通讯故障", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_028": { "name": "SC_NoCOM_EK1501Converter", "cn": "变频器EK1501通讯故障", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_023": { "name": "SC_NoCOM_BK1250Nacelle", "cn": "机舱BK1250通讯故障", "subsystem": "PLCSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_025": { "name": "SC_NoCOM_EK1100Nacelle", "cn": "机舱EK1100通讯故障", "subsystem": "PLCSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_036": { "name": "SC_NoCOM_EL6751Nacelle", "cn": "机舱EL6751通讯故障", "subsystem": "PLCSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_030": { "name": "SC_NoCOM_EL6731Pitch", "cn": "机舱EL6731通讯故障", "subsystem": "PLCSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_028": { "name": "SC_NoCOM_EK1100TowerBase", "cn": "塔底EK1100通讯故障", "subsystem": "PLCSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_06_029": { "name": "SC_NoCOM_EL6751Converter", "cn": "变频器EL6751通讯故障", "subsystem": "PLCSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_015": { "name": "SC_NoCOM_EK1501GCC", "cn": "GCC-EK1501通讯故障", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_016": { "name": "SC_NoCOM_BK1250GCC", "cn": "GCC-BK1250通讯故障", "subsystem": "PLCSystem", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#15ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_014": { "name": "SC_SoftSafetyChain_Tripped", "cn": "硬件安全链失效,软件安全链动作", "subsystem": "SafetySystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_045": { "name": "SC_FaultAI_GearOilDiffPressureInlineFilter", "cn": "齿轮箱过滤器压差传感器故障", "subsystem": "Gearbox", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_047": { "name": "SC_GBXOilInletPressure_MAX_Stop", "cn": "齿轮箱入口压力过高故障", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_046": { "name": "SC_RepFaultGBXOilInletPressure_Stop", "cn": "齿轮箱入口压力过高或过低故障重复出现", "subsystem": "Gearbox", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_033": { "name": "SC_FaultAI_NacelleWindSpeed", "cn": "Thies风向标故障", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_034": { "name": "SC_FaultAI_Nacelle_Humidity", "cn": "机舱湿度传感器故障", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_035": { "name": "SC_WindIrisData_NotValid", "cn": "激光雷达数据无效", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_036": { "name": "OC_WindIrisForControl", "cn": "当前采用激光雷达进行偏航控制", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_014": { "name": "SC_FaultAI_RotorSpeedFromOverspeedRelay", "cn": "过速传感器故障", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_036": { "name": "SC_RestoreStorageFileFailed", "cn": "读取掉电保存变量文件失败", "subsystem": "PLCSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_037": { "name": "SC_StoreStorageFileFailed", "cn": "存储掉电保存变量文件失败", "subsystem": "PLCSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_018": { "name": "SC_TorqeuForceMode", "cn": "扭矩强制模式开启,扭矩可以随意设定", "subsystem": "ConverterContainer", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_07_001": { "name": "SC_BrakePressureHighUnderProduction", "cn": "发电时刹车压力高故障", "subsystem": "HSBrakeSystem", "level": "170-故障停机", "reset_mode": "F", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_07_002": { "name": "SC_HSBrakeIsWorking", "cn": "高速刹车投入中", "subsystem": "HSBrakeSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_005": { "name": "SC_FaultInputAirPressure", "cn": "大气压力传感器故障", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_001": { "name": "SC_PCH_HubBlade1_PeakAlert", "cn": "桨叶1振动峰值过高警告", "subsystem": "MeasurementSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_002": { "name": "SC_PCH_HubBlade1_PeakDanger", "cn": "桨叶1振动峰值过高危险警告", "subsystem": "MeasurementSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_003": { "name": "SC_PCH_HubBlade1_PPAlert", "cn": "桨叶1峰-峰值过高警告", "subsystem": "MeasurementSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_004": { "name": "SC_PCH_HubBlade1_PPDanger", "cn": "桨叶1峰-峰值过高危险警告", "subsystem": "MeasurementSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_005": { "name": "SC_PCH_HubBlade2_PeakAlert", "cn": "桨叶2振动峰值过高警告", "subsystem": "MeasurementSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_006": { "name": "SC_PCH_HubBlade2_PeakDanger", "cn": "桨叶2振动峰值过高危险警告", "subsystem": "MeasurementSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_007": { "name": "SC_PCH_HubBlade2_PPAlert", "cn": "桨叶2峰-峰值过高警告", "subsystem": "MeasurementSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_008": { "name": "SC_PCH_HubBlade2_PPDanger", "cn": "桨叶2峰-峰值过高危险警告", "subsystem": "MeasurementSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_009": { "name": "SC_PCH_HubBlade3_PeakAlert", "cn": "桨叶3振动峰值过高警告", "subsystem": "MeasurementSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_010": { "name": "SC_PCH_HubBlade3_PeakDanger", "cn": "桨叶3振动峰值过高危险警告", "subsystem": "MeasurementSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_011": { "name": "SC_PCH_HubBlade3_PPAlert", "cn": "桨叶3峰-峰值过高警告", "subsystem": "MeasurementSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_012": { "name": "SC_PCH_HubBlade3_PPDanger", "cn": "桨叶3峰-峰值过高危险警告", "subsystem": "MeasurementSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_013": { "name": "SC_PCH_HubFFTBlade1_Alert", "cn": "桨叶1频谱强度异常警告", "subsystem": "MeasurementSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_014": { "name": "SC_PCH_HubFFTBlade1_Danger", "cn": "桨叶1频谱强度异常危险警告", "subsystem": "MeasurementSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#3h", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_015": { "name": "SC_PCH_HubFFTBlade2_Alert", "cn": "桨叶2频谱强度异常警告", "subsystem": "MeasurementSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_016": { "name": "SC_PCH_HubFFTBlade2_Danger", "cn": "桨叶2频谱强度异常危险警告", "subsystem": "MeasurementSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#3h", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_017": { "name": "SC_PCH_HubFFTDangerRepeat", "cn": "桨叶频谱危险警告反复出现", "subsystem": "MeasurementSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_018": { "name": "SC_PCH_HubBadDataDetected", "cn": "主控系统读得的叶片PCH震动值长时间不刷新", "subsystem": "MeasurementSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#30s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_019": { "name": "OC_PCH_HubScaleFactorEqualZero", "cn": "叶片PCH读取的振动值系数为0", "subsystem": "MeasurementSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_101": { "name": "SC_FaultPofibusWCSG", "cn": "主控系统与发电机水冷系统Profibus通讯故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#2m", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_102": { "name": "SC_EmergencyModeOfWCSG", "cn": "发电机水冷系统急停被拍下触发了紧急停机", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_103": { "name": "SC_PumpOverLoadOfWCSG", "cn": "发电机水冷系统循环泵过载", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_104": { "name": "SC_TempHighOfWCSG", "cn": "发电机水冷系统过温", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_105": { "name": "SC_PreHighOfWCSG", "cn": "发电机水冷系统过压", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_106": { "name": "SC_PreLowOfWCSG", "cn": "发电机水冷系统压力过低", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_107": { "name": "SC_NotReadyOfWCSG", "cn": "发电机水冷系统没有做好运行准备", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_108": { "name": "SC_FaultStatusOfWCSG", "cn": "发电机水冷系统故障模式", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_109": { "name": "SC_TempLowOfWCSG", "cn": "发电机水冷系统温度过低", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_110": { "name": "SC_TempSignalErrorOfWCSG", "cn": "发电机水冷系统温度信号错误", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_111": { "name": "SC_PreSignalErrorOfWCSG", "cn": "发电机水冷系统压力信号错误", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_112": { "name": "SC_ServiceModeOfWCSG", "cn": "发电机水冷系统本地模式", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_113": { "name": "SC_OverLoadFanOfWCSG", "cn": "发电机水冷系统散热器过载", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_116": { "name": "OC_GenWaterCoolValveTimeOut", "cn": "发电机水冷三通阀长时间不打开或不闭合", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_117": { "name": "SC_GenWaterCoolPumpAlarm", "cn": "发电机水冷主循环泵或电加热器或三通阀开关跳闸", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#3s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_118": { "name": "SC_GLGenWaterCoolInletPT100Fault", "cn": "发电机水冷供水温度传感器TT01 故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_119": { "name": "OC_GLGenWaterCoolOutletTemp", "cn": "发电机水冷回水温度传感器TT02 故障", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_120": { "name": "OC_GLGenWaterCoolInletPre", "cn": "发电机水冷供水压力变送器PT01 故障", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_121": { "name": "OC_GLGenWaterCoolOutletPre", "cn": "发电机水冷回水压力变送器PT02 故障", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_122": { "name": "SC_GLGenWaterCoolInletTempHigh2", "cn": "发电机水冷供水温度过高故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_123": { "name": "OC_GLGenWaterCoolInletTempHigh1", "cn": "发电机水冷供水温度过高警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_124": { "name": "SC_GLGenWaterCoolOutletTempHigh", "cn": "发电机水冷回水温度高", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_125": { "name": "SC_GLGenWaterCoolInletPreHigh2", "cn": "发电机水冷供水压力过高故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_126": { "name": "OC_GLGenWaterCoolInletPreHigh1", "cn": "发电机水冷供水压力过高警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_127": { "name": "OC_GLGenWaterCoolInletPreLow1", "cn": "发电机水冷供水压力过低警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_128": { "name": "SC_GLGenWaterCoolInletPreLow2", "cn": "发电机水冷供水压力过低故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_129": { "name": "OC_GLGenWaterCoolOutletPreLow1", "cn": "发电机水冷回水压力过低警告", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_130": { "name": "SC_GLGenWaterCoolOutletPreLow2", "cn": "发电机水冷回水压力过低故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_131": { "name": "OC_GLGenWaterCoolInletTempLow", "cn": "发电机水冷供水温度低", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_132": { "name": "OC_GenWaterCoolFan1Alarm", "cn": "发电机水冷空散电机1或2或3开关跳闸", "subsystem": "Generator", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_133": { "name": "SC_GenWaterCoolInOutPressureDiffHigh", "cn": "发电机水冷入口、出口压差过大故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_134": { "name": "SC_GenWaterCoolInOutPressureDiffLow", "cn": "发电机水冷入口、出口压差过低故障", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_135": { "name": "OC_GenWaterCoolInOutPressureDetect", "cn": "发电机水冷系统压力建立,达到加热器启动条件", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_136": { "name": "SC_GenWaterCoolHeaterOnTooLong", "cn": "发电机水冷加热器加热时间过长", "subsystem": "Generator", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tGenWaterCoolHeaterOnWorking", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_017": { "name": "OC_GENGLPumpControlManualMode", "cn": "发电机高澜水冷系统泵控制进入手动模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_018": { "name": "OC_GENGLPumpControlForceMode", "cn": "发电机高澜水冷系统泵控制进入强制模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_019": { "name": "OC_GENGLHeaterControlManualMode", "cn": "发电机高澜水冷系统加热器控制进入手动模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_020": { "name": "OC_GENGLHeaterControlForceMode", "cn": "发电机高澜水冷系统加热器控制进入强制模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_021": { "name": "OC_GENGLValveControlManualMode", "cn": "发电机高澜水冷系统三通阀控制进入手动模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_022": { "name": "OC_GENGLValveControlForceMode", "cn": "发电机高澜水冷系统三通阀控制进入强制模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_023": { "name": "OC_GENGLFan1ControlManualMode", "cn": "发电机高澜水冷系统风扇1控制进入手动模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_024": { "name": "OC_GENGLFan1ControlForceMode", "cn": "发电机高澜水冷系统风扇1控制进入强制模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_025": { "name": "OC_GENGLFan2ControlManualMode", "cn": "发电机高澜水冷系统风扇2控制进入手动模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_026": { "name": "OC_GENGLFan2ControlForceMode", "cn": "发电机高澜水冷系统风扇2控制进入强制模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_027": { "name": "OC_GENGLFan3ControlManualMode", "cn": "发电机高澜水冷系统风扇3控制进入手动模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_028": { "name": "OC_GENGLFan3ControlForceMode", "cn": "发电机高澜水冷系统风扇3控制进入强制模式", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_029": { "name": "OC_GENGLPumpON", "cn": "发电机高澜水冷系统泵开启", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_030": { "name": "OC_GENGLHeaterON", "cn": "发电机高澜水冷系统加热器开启", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_031": { "name": "OC_GENValveON", "cn": "发电机高澜水冷系统三通阀开启", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_032": { "name": "OC_GLFan1ON", "cn": "发电机高澜水冷系统风扇1开启", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_033": { "name": "OC_GLFan2ON", "cn": "发电机高澜水冷系统风扇2开启", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_06_034": { "name": "OC_GLFan3ON", "cn": "发电机高澜水冷系统风扇3开启", "subsystem": "Generator", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_102": { "name": "SC_MotorProtection_WCSC", "cn": "变频器水冷系统保护空开触发", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_008": { "name": "SC_ConverterNoFeedBackForSwitchON_CB", "cn": "断路器长时间不响应闭合命令", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tDelayCircuitBrakerClose", "powerup_delay": "T#10s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_028": { "name": "SC_ConverterCrowbarActive", "cn": "变频器过压保护被触发", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_051": { "name": "OC_CVTWaterCoolInletPreHigh1", "cn": "变频器水冷供水压力高报警", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_052": { "name": "OC_CVTWaterCoolInletPreLow1", "cn": "变频器水冷供水压力低报警", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_053": { "name": "SC_CVTWaterCoolInletPreLow2", "cn": "变频器水冷供水压力低故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_054": { "name": "OC_CVTWaterCoolOutletPreLow1", "cn": "变频器水冷回水压力低报警", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_055": { "name": "SC_CVTWaterCoolOutletPreLow2", "cn": "变频器水冷回水压力低故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_056": { "name": "OC_CVTWaterCoolInletTempLow", "cn": "变频器水冷供水温度低", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_057": { "name": "OC_CVTWaterCoolFanAlarm", "cn": "变频器水冷空散电机或三通阀开关跳闸(空冷器电机跳闸)", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_058": { "name": "SC_CVTWaterCoolInletPreHigh2", "cn": "变频器水冷供水压力高故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_059": { "name": "OC_CVTWaterCoolValveTimeOut", "cn": "变频器水冷三通阀长时间不打开或不闭合", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_060": { "name": "SC_ConverterHeatingModeTimeOut", "cn": "变频器处于暖机模式时间过长", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tConverterHeatingModeTimeout", "powerup_delay": "T#1s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_061": { "name": "SC_CVTWaterCoolInOutPressureDiffHigh", "cn": "变频器水冷入口、出口压差过大", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_062": { "name": "SC_CVTWaterCoolInOutPressureDiffLow", "cn": "变频器水冷入口、出口压差太低", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_063": { "name": "SC_CVTWaterCoolHeaterOnTooLong", "cn": "变频器水冷加热器加热时间过长", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tCVTWaterCoolHeaterOnWorking", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_113": { "name": "OC_ConverterHeatingModeHardWire", "cn": "变频器暖机模式", "subsystem": "ConverterContainer", "level": "30-待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_115": { "name": "OC_ConverterHeatingModeCanBus", "cn": "变频器暖机模式", "subsystem": "ConverterContainer", "level": "30-待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_116": { "name": "OC_CVTWaterCoolInOutPressureDetect", "cn": "变频器水冷系统压力建立,达到加热器启动条件", "subsystem": "ConverterContainer", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0S", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_017": { "name": "SC_FaultOvervoltageProtectionConverter", "cn": "变频柜主电源防雷器故障", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_029": { "name": "SC_FaultPofibusWCSC", "cn": "与变频器水冷系统PROFIBUS通讯故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#2m", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_030": { "name": "SC_EmergencyModeOfWCSC", "cn": "变频器水冷系统急停被拍下", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_031": { "name": "SC_PumpOverLoadOfWCSC", "cn": "变频器水冷系统循环泵过载", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_032": { "name": "SC_TempHighOfWCSC", "cn": "变频器水冷系统过温", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_033": { "name": "SC_PreHighOfWCSC", "cn": "变频器水冷系统过压", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_034": { "name": "SC_PreLowOfWCSC", "cn": "变频器水冷系统压力过低", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_035": { "name": "SC_NotReadyOfWCSC", "cn": "变频器水冷系统没有准备好", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_036": { "name": "SC_FaultStatusOfWCSC", "cn": "变频器水冷系统故障模式", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_037": { "name": "SC_TempLowOfWCSC", "cn": "变频器水冷系统温度过低", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_038": { "name": "SC_TempSignalErrorOfWCSC", "cn": "变频器水冷系统温度信号错误", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_039": { "name": "SC_PreSignalErrorOfWCSC", "cn": "变频器水冷系统压力信号错误", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_040": { "name": "SC_ServiceModeOfWCSC", "cn": "变频器水冷系统维护模式", "subsystem": "ConverterContainer", "level": "210-维护", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_041": { "name": "SC_OverLoadFanOfWCSC", "cn": "变频器水冷系统散热器过载", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#60s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_042": { "name": "SC_CVTWaterCoolPumpAlarm", "cn": "变频器水冷主循环泵或电加热器故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#3s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_043": { "name": "SC_CVTWaterCoolInletTemp", "cn": "变频器水冷供水温度传感器TT01 故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_044": { "name": "OC_CVTWaterCoolOutletTemp", "cn": "变频器水冷回水温度传感器TT02 故障", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_045": { "name": "OC_CVTWaterCoolInletPre", "cn": "变频器水冷供水压力变送器PT01 故障", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_046": { "name": "OC_CVTWaterCoolOutletPre", "cn": "变频器水冷回水压力变送器PT02 故障", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_047": { "name": "SC_CVTWaterCoolInletTempHigh2", "cn": "变频器水冷供水温度高故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_048": { "name": "OC_CVTWaterCoolInletTempHigh1", "cn": "变频器水冷供水温度高报警", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_05_049": { "name": "SC_CVTWaterCoolOutletTempHigh", "cn": "变频器水冷回水温度高", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_009": { "name": "SC_Sensor1RotorImpulsesDefect", "cn": "低速端#1接近开关故障", "subsystem": "Drivetrain", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_04_010": { "name": "SC_Sensor2RotorImpulsesDefect", "cn": "低速端#2接近开关故障", "subsystem": "Drivetrain", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_1sec" ], "detectable_in_10min": false }, "02_04_012": { "name": "SC_OverspeedRelayDetectFail", "cn": "低速端转速与过速继电器测速不匹配", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_001": { "name": "SC_TempNacelleCabinetOutOfSpec", "cn": "机舱柜恒温器测得温度高于设定值", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_003": { "name": "SC_NacelleUPS24VPLC_Alarm", "cn": "机舱柜24V UPS报警", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#15s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_004": { "name": "SC_TowerThermostatsProtBreak", "cn": "塔底温控器电源空开跳开", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": null, "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_005": { "name": "SC_NacelleThermostatsProtBreak", "cn": "机舱温控器电源空开跳开", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": null, "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_006": { "name": "SC_NacelleUPS24VPLC_BatteryMode", "cn": "机舱柜24V UPS处于电池模式", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_008": { "name": "SC_FaultOvervoltageProtectionCabinetNacelle", "cn": "机舱柜690V电源防雷器,机舱柜400V电源防雷器或塔底柜230V电源防雷器发生故障", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_020": { "name": "SC_NacelleFuse690VMainSupply", "cn": "机舱柜690V电源熔断器故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_021": { "name": "SC_NacelleFuse400VMainSupply", "cn": "机舱柜400V电源熔断器故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_026": { "name": "SC_NacelleFuseHeaterSlipring", "cn": "机舱柜中电气滑环加热器保护空开跳开", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_033": { "name": "SC_NacelleFuse230VCabClimatisation", "cn": "机舱柜加热器230V保护空开跳开", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_039": { "name": "SC_NacelleFuse400VAC_24VDC", "cn": "机舱柜中AC400V转DC24V电源模块的供电保护空开跳开", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_120": { "name": "OC_NacelleHeaterCabinetON", "cn": "机舱柜加热器设定打开", "subsystem": "Cabinet", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_02_129": { "name": "OC_Nacelle_24VPLC_BatteryCharge", "cn": "机舱柜中24V UPS处于充电模式", "subsystem": "Cabinet", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_12_002": { "name": "SC_TurbineInServiceNacelle", "cn": "机舱发出风机进入检修或变桨检修命令", "subsystem": "Cabinet", "level": "210-维护", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_12_006": { "name": "SC_ResetStatusCodesFromNacelleOrTowerBase", "cn": "机舱或塔底发出复位状态字命令", "subsystem": "Cabinet", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_001": { "name": "SC_TempTowerBaseCabinetOutOfSpec", "cn": "塔底柜恒温器测得温度高于设定值", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_004": { "name": "SC_TowerNHFuse690VMAINSupply", "cn": "塔底柜690V电源熔断器故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_006": { "name": "SC_FaultOvervoltageProtectionTowerBase", "cn": "塔底柜690V,400V或变频柜主电源防雷器故障", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_007": { "name": "SC_TowerNHFuse400VMainSupply", "cn": "塔底柜400V电源熔断器故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_011": { "name": "SC_TowerFuse230VCabClimatisation", "cn": "塔底柜加热器或散热风扇的230V电源保护空开跳开", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_034": { "name": "SC_TowerUPS24VPLC_Alarm", "cn": "塔底24V UPS报警", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_035": { "name": "SC_TowerUPS24VPLC_BatteryMode", "cn": "塔底24V UPS电池模式", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_036": { "name": "OC_TowerUPS24VPLC_BatteryCharge", "cn": "塔底24V UPS电池充电模式", "subsystem": "Cabinet", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_08_005": { "name": "SC_TurbineInRepairTowerBase", "cn": "塔底柜检修开关打开,要求风机进入检修模式", "subsystem": "Cabinet", "level": "220-维修", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "220", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_08_105": { "name": "SC_TowerBrakeForClimbingActivated", "cn": "塔底柜的攀爬开关打开,要求停机安全爬塔", "subsystem": "Cabinet", "level": "210-维护", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_001": { "name": "OC_CT_HeaterManualMode", "cn": "塔底控制柜加热器手动模式开启", "subsystem": "Cabinet", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "True", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_002": { "name": "OC_CT_HeaterForceMode", "cn": "塔底控制柜加热器强制模式开启", "subsystem": "Cabinet", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "True", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_003": { "name": "OC_CN_HeaterManualMode", "cn": "机舱控制柜加热器手动模式开启", "subsystem": "Cabinet", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "True", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_004": { "name": "OC_CN_HeaterForceMode", "cn": "机舱控制柜加热器强制模式开启", "subsystem": "Cabinet", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "True", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_040": { "name": "SC_TowerFuse24VMediaConvPlusBCSafetyChain", "cn": "塔底以太网交换器24V电源保险丝故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_100": { "name": "OC_TowerHeaterCabinet_ON", "cn": "塔底控制柜加热器打开", "subsystem": "Cabinet", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_02_109": { "name": "OC_ControlCabinetHeatingMode", "cn": "控制柜暖机模式", "subsystem": "Cabinet", "level": "30-待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_02_110": { "name": "SC_CabinetHeatingModeTimeout", "cn": "控制柜暖机超时", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#30m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_03_001": { "name": "SC_TempTowerBase_high", "cn": "塔底温度过高警告", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_03_002": { "name": "SC_TempTowerBase_low", "cn": "塔底温度过低警告", "subsystem": "Cabinet", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#24h", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_03_003": { "name": "SC_TempTowerBase_MAX", "cn": "塔底温度过高故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_03_004": { "name": "SC_TempTowerBase_MIN", "cn": "塔底温度过低故障", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": [ "_10min" ], "detectable_in_10min": true }, "03_03_007": { "name": "SC_RepFaultTempTowerBase", "cn": "塔底温度过高过低警告重复出现", "subsystem": "Cabinet", "level": "170-故障停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_07_010": { "name": "SC_TowerDoorSwitchSignalOpen", "cn": "塔筒门被打开", "subsystem": "Cabinet", "level": "10-其他", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_013": { "name": "SC_Blade1_PilotContactNotConnected", "cn": "1号电池柜航空插头没有插好", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_014": { "name": "SC_Blade1_DCLinkVoltageTooLow", "cn": "1号桨PM直流母线电压低", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_017": { "name": "SC_Blade1_CollectiveWarning", "cn": "1号桨的出现警报", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_018": { "name": "SC_Blade1_ErrorWithBatteryDrivenSTOP", "cn": "1号桨故障,触发电池驱动回桨", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_033": { "name": "SC_Blade2_PilotContactNotConnected", "cn": "2号电池柜航空插头没有插好", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_034": { "name": "SC_Blade2_DCLinkVoltageTooLow", "cn": "2号桨PM直流母线电压低", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_037": { "name": "SC_Blade2_CollectiveWarning", "cn": "2号桨的出现警报", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_038": { "name": "SC_Blade2_ErrorWithBatteryDrivenSTOP", "cn": "2号桨故障,触发电池驱动回桨", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_053": { "name": "SC_Blade3_PilotContactNotConnected", "cn": "3号电池柜航空插头没有插好", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_054": { "name": "SC_Blade3_DCLinkVoltageTooLow", "cn": "3号桨PM直流母线电压低", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_057": { "name": "SC_Blade3_CollectiveWarning", "cn": "3号桨的出现警报", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_058": { "name": "SC_Blade3_ErrorWithBatteryDrivenSTOP", "cn": "3号桨故障,触发电池驱动回桨", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_061": { "name": "SC_PitchSystem24VTripped", "cn": "变桨系统24V电源故障", "subsystem": "pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5.1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_062": { "name": "SC_ErrorBatteryChargerAxis1or2or3", "cn": "变桨系统电池充电回路故障", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tSetDelayForBatteryChargerFault", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_069": { "name": "SC_Pitch_CollectiveFaultMessage", "cn": "变桨系统发生2级故障", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5.1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_070": { "name": "SC_Pitch_ErrorWithBatteryDrivenSTOP", "cn": "变桨系统与主控系统的Profibus通讯或与PM的CAN通讯出现故障", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tSetDelayForCANProfibus", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_076": { "name": "SC_Pitch_CollectiveWarning", "cn": "变桨系统出现警告", "subsystem": "Pitchsystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_077": { "name": "SC_Pitch_MainsFailure", "cn": "变桨系统400V电网存在故障", "subsystem": "Pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#5s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_100": { "name": "SC_Blade3_OvertempStartResistorAxis1or2or3", "cn": "1号,2号或3号桨报告预充电电阻过温", "subsystem": "pitchsystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_104": { "name": "SC_Pitch_CANBusError", "cn": "变桨系统与PM的CAN通讯故障", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "PAR_tSetDelayForCANProfibus", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_106": { "name": "SC_Pitch_MotorEncIncoherence", "cn": "变桨系统报告桨叶间角度相差过大(相差2度持续120毫秒)", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tSetDelayForCANProfibus", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "198", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_107": { "name": "OC_PitchMaintenanceMode", "cn": "变桨系统处于维护模式", "subsystem": "Pitchsystem", "level": "210-维护", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "210", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "01_05_109": { "name": "OC_PitchHeatingMode", "cn": "变桨系统暖机模式", "subsystem": "PitchSystem", "level": "30-待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "50", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": [ "_1min" ], "detectable_in_10min": false }, "01_05_110": { "name": "SC_PitchHeatingModeTimeout", "cn": "变桨系统暖机超时", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#30m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_030": { "name": "SC_SELFTEST_PitchAccumulatorStatusError1", "cn": "桨叶1电池自检失败", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tSELFTEST_PitchBatteryStatusError", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_031": { "name": "SC_SELFTEST_PitchAccumulatorStatusError2", "cn": "桨叶2电池自检失败", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tSELFTEST_PitchBatteryStatusError", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_032": { "name": "SC_SELFTEST_PitchAccumulatorStatusError3", "cn": "桨叶3电池自检失败", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tSELFTEST_PitchBatteryStatusError", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_117": { "name": "SC_TimeOutPitch2SelfTest", "cn": "桨叶2电池自检超时", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#50s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_118": { "name": "SC_TimeOutPitch3SelfTest", "cn": "桨叶3电池自检超时", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#50s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "03_09_116": { "name": "SC_TimeOutPitch1SelfTest", "cn": "桨叶1电池自检超时", "subsystem": "PitchSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#50s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_019": { "name": "OC_ConverterSpeedModeSwitchedOn", "cn": "变频器转速模式开启", "subsystem": "ConverterContainer", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_020": { "name": "OC_ConverterServiceSwichedOn", "cn": "变频器Service功能开启", "subsystem": "ConverterContainer", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "220", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_021": { "name": "SC_Converter_MCBCloseTimeout", "cn": "变频器合主断路器超时", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "PAR_tCVT_MCBCloseTimeout", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_022": { "name": "SC_CVT_LVRT_Timeout", "cn": "变频器LVRT超时", "subsystem": "ConverterContainer", "level": "", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tCVT_LVRT_Timeout", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_023": { "name": "SC_CVT_IGBT_TempHigh", "cn": "IGBT温度高报警", "subsystem": "ConverterContainer", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_024": { "name": "SC_CVT_IGBT_TempVeryHigh", "cn": "IGBT温度高故障", "subsystem": "ConverterContainer", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_025": { "name": "OC_ConverterHeatingModeOn", "cn": "变频器暖机模式", "subsystem": "ConverterContainer", "level": "30-待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_026": { "name": "SC_CVT_MinInterval_TwiceCharge_Waiting", "cn": "变频器两次充电最短时间间隔等待中", "subsystem": "ConverterContainer", "level": "30-待机", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_027": { "name": "SC_FaultInput_CVT_Humidity", "cn": "变频器湿度传感器故障", "subsystem": "ConverterContainer", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_035": { "name": "SC_Transformer_Temp_Sensor_Fault", "cn": "变压器温度传感器失效", "subsystem": "GCC", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_036": { "name": "SC_Transformer_Temp_High_Alarm", "cn": "变压器温度过高警告", "subsystem": "GCC", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_037": { "name": "SC_Transformer_Temp_Winding_different", "cn": "变压器不同绕组温差过大", "subsystem": "GCC", "level": "", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_038": { "name": "SC_Transformer_Temp_No_reading", "cn": "变压器温度值无读数", "subsystem": "GCC", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_039": { "name": "SC_Transformer_WaterLeak", "cn": "变压器水泄漏", "subsystem": "GCC", "level": "", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_040": { "name": "SC_Transformer_Door_Open", "cn": "变压器柜门打开", "subsystem": "GCC", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_041": { "name": "SC_Transformer_Cooling_Motor_Not_running", "cn": "变压器冷却风扇没有运行", "subsystem": "GCC", "level": "", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_042": { "name": "SC_FaultPT100_GCC_Temp2", "cn": "变压器环境温度PT100故障", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_043": { "name": "SC_UPS_Bypass", "cn": "UPS被旁路", "subsystem": "GCC", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_006": { "name": "SC_TowerToNacelle690PowerSupplyOff", "cn": "塔底到机舱690V供电MCB跳开", "subsystem": "Cabinet", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_007": { "name": "SC_TowerToNacelle400PowerSupplyOff", "cn": "塔底到机舱400V供电MCB跳开", "subsystem": "Cabinet", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_008": { "name": "SC_AUXTransformer690PowerSupplyOff", "cn": "控制柜与变压器间690V MCB跳开", "subsystem": "Cabinet", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_009": { "name": "SC_AUXTransformer400PowerSupplyOff", "cn": "控制柜与变压器间400V MCB跳开", "subsystem": "Cabinet", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_140": { "name": "SC_Blade1PositionCheckFault", "cn": "1号桨叶角度检查偏差过大故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_141": { "name": "SC_Blade2PositionCheckFault", "cn": "2号桨叶角度检查偏差过大故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_142": { "name": "SC_Blade3PositionCheckFault", "cn": "3号桨叶角度检查偏差过大故障", "subsystem": "PitchSystem", "level": "40-警告待机", "reset_mode": "M", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_011": { "name": "SC_Selftest5_OK", "cn": "自检5完成结果正常", "subsystem": "TurbineStateMachine", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_012": { "name": "SC_Selftest5_Warning", "cn": "自检5完成结果报警", "subsystem": "TurbineStateMachine", "level": "", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_013": { "name": "SC_TowerFrequency_OK", "cn": "塔筒频率连续监测结果正常", "subsystem": "TurbineStateMachine", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_014": { "name": "SC_TowerFrequencyTest_Warning", "cn": "塔筒频率连续监测结果报警", "subsystem": "TurbineStateMachine", "level": "", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_015": { "name": "SC_Selftest5_Timeout", "cn": "自检5运行超时", "subsystem": "TurbineStateMachine", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "PAR_tTimeoutSelftest5", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_037": { "name": "SC_PCHFault", "cn": "PCH出现异常", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_038": { "name": "OC_SwitchPCHToGJSensor", "cn": "振动检测由PCH切换到G&J传感器", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_039": { "name": "SC_GJSensorFault", "cn": "G&J传感器出现异常", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_040": { "name": "SC_BothVibrationSensorFault", "cn": "PCH与G&J传感器同时出现异常", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#30s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_041": { "name": "SC_VibrationOmniDirectionLevel1_GJ", "cn": "G&J检测到塔架水平方向的加速度高于1级振动门限值", "subsystem": "NacelleSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#2s", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "51", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_042": { "name": "SC_VibrationOmniDirectionLevel2_GJ", "cn": "G&J检测到塔架水平方向的加速度高于2级振动门限值", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#2s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_043": { "name": "SC_RepFaultVibrationXAxis_GJ", "cn": "阵风过大保护性停机", "subsystem": "NacelleSystem", "level": "139-大风停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "139", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_044": { "name": "SC_VibrationForeaftDirection1_GJ", "cn": "G&J检测到塔架前后方向的加速度高于1级振动门限值", "subsystem": "NacelleSystem", "level": "30-待机", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#2s", "powerup_delay": "T#0s", "repeat_n": "3", "repeat_period": "T#1h", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_045": { "name": "SC_VibrationForeaftDirection2_GJ", "cn": "G&J检测到塔架前后方向的加速度高于2级振动门限值", "subsystem": "NacelleSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#2s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_046": { "name": "SC_RepFaultVibrationYAxis_GJ", "cn": "阵风过大保护性停机", "subsystem": "NacelleSystem", "level": "139-大风停机", "reset_mode": "M", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "139", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_047": { "name": "OC_VibrationOmniDirection_GJ", "cn": "塔架水平方向的加速度超限", "subsystem": "NacelleSystem", "level": "30-待机", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_048": { "name": "OC_VibrationForeaftDirection_GJ", "cn": "塔架前后方向的加速度超限", "subsystem": "NacelleSystem", "level": "30-待机", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "30", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_049": { "name": "SC_BlockYawForVibrationHigh_GJ", "cn": "G&J传感器检测到前后方向振动值过大禁止偏航一分钟", "subsystem": "NacelleSystem", "level": "10-其他", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_016": { "name": "SC_SafetyChain_SSDSwitch_GJ", "cn": "G&J传感器测得的SSD震动值高于设定值", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#15s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_017": { "name": "SC_SafetyChain_SSDMax_GJ", "cn": "G&J的SSD开关断开导致安全链断开", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#30s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_018": { "name": "SC_SafetyChain_VibrationSwitch_GJ", "cn": "G&J的振动过大继电器断开导致安全链断开", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#15s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_019": { "name": "SC_VibrationRelayActive_GJ", "cn": "G&J振动过大继电器触发", "subsystem": "SafetySystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_015": { "name": "SC_MainShaftCrack", "cn": "主轴两端转速差过大判断主轴断裂", "subsystem": "Drivetrain", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1m", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "200", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_028": { "name": "SC_TCS_Pump1_Overload", "cn": "塔底水冷泵1过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": null, "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_029": { "name": "SC_TCS_Pump2_Overload", "cn": "塔底水冷泵2过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": null, "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_030": { "name": "SC_TCS_Pumps_Overload", "cn": "塔底水冷泵全部过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": null, "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_031": { "name": "SC_TCS_Pump1_MCB", "cn": "塔底水冷泵1MCB跳开", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_032": { "name": "SC_TCS_Pump2_MCB", "cn": "塔底水冷泵2MCB跳开", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_033": { "name": "SC_TCS_Pumps_MCB", "cn": "塔底水冷泵MCB全部跳开", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_034": { "name": "SC_TCSPump1Failure_NoPressure", "cn": "塔底水冷泵1无压力故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_035": { "name": "SC_TCSPump2Failure_NoPressure", "cn": "塔底水冷泵2无压力故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#10s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_036": { "name": "SC_TCS_Heater_Overload", "cn": "塔底水冷加热器过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": null, "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_037": { "name": "SC_TCS_Heater_MCB", "cn": "塔底水冷加热器MCB跳开", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_038": { "name": "SC_TCS_InletWaterTempLow_Warning", "cn": "塔底水冷进水口水温过低警告", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_039": { "name": "SC_TCS_InletWaterPT100Fault", "cn": "塔底水冷进水口PT100故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_040": { "name": "SC_TCS_InsideFan1_Overload", "cn": "塔底水冷塔内风扇1过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": null, "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_041": { "name": "SC_TCS_InsideFan2_Overload", "cn": "塔底水冷塔内风扇2过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": null, "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_042": { "name": "SC_TCS_InsideFan1_MCB", "cn": "塔底水冷塔内风扇1MCB跳开", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_043": { "name": "SC_TCS_InsideFan2_MCB", "cn": "塔底水冷塔内风扇2MCB跳开", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_044": { "name": "SC_TCS_TowerTempHigh", "cn": "塔内温度高警告", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_045": { "name": "SC_TCS_TowerTempTooHigh", "cn": "塔内温度过高停机", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_046": { "name": "SC_TCS_Cooler1FanA_Overload", "cn": "塔底冷却器1风扇A过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_047": { "name": "SC_TCS_Cooler1FanB_Overload", "cn": "塔底冷却器1风扇B过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_048": { "name": "SC_TCS_Cooler2FanA_Overload", "cn": "塔底冷却器2风扇A过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_049": { "name": "SC_TCS_Cooler2FanB_Overload", "cn": "塔底冷却器2风扇B过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_050": { "name": "SC_TCS_Cooler3FanA_Overload", "cn": "塔底冷却器3风扇A过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_051": { "name": "SC_TCS_Cooler3FanB_Overload", "cn": "塔底冷却器3风扇B过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_052": { "name": "SC_TCS_Cooler4FanA_Overload", "cn": "塔底冷却器4风扇A过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_053": { "name": "SC_TCS_Cooler4FanB_Overload", "cn": "塔底冷却器4风扇B过载", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_054": { "name": "SC_TCS_Cooler1Fans_MCB", "cn": "塔底冷却器1风扇 MCB跳开", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_055": { "name": "SC_TCS_Cooler2Fans_MCB", "cn": "塔底冷却器2风扇 MCB跳开", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_056": { "name": "SC_TCS_Cooler3Fans_MCB", "cn": "塔底冷却器3风扇 MCB跳开", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_057": { "name": "SC_TCS_Cooler4Fans_MCB", "cn": "塔底冷却器4风扇 MCB跳开", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_058": { "name": "SC_TCSWaterPressureTooLow", "cn": "塔底水冷水压力过低故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_059": { "name": "OC_TCS_Pump1_ON", "cn": "塔底水冷泵1启动", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_060": { "name": "OC_TCS_Pump2_ON", "cn": "塔底水冷泵2启动", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_061": { "name": "OC_TCS_Heater_ON", "cn": "塔底水冷加热器启动", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_062": { "name": "SC_TCS_CVTOutletPT100Fault", "cn": "塔底水冷变频器出口PT100故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_063": { "name": "SC_TCS_TrafoOutletPT100Fault", "cn": "塔底水冷变压器出口PT100故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_064": { "name": "SC_TCS_OutletPT100Fault", "cn": "塔底水冷被冷却器出口PT100故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_065": { "name": "SC_TCS_InsideCoolerInletPT100Fault", "cn": "塔底水冷塔内冷却器入口PT100故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_066": { "name": "SC_TCS_PumpManualMode", "cn": "塔底水冷泵开启手动模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_067": { "name": "SC_TCS_PumpForceMode", "cn": "塔底水冷泵开启强制模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_068": { "name": "SC_TCS_FanManualMode", "cn": "塔底水冷系统中有风扇开启了手动模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_069": { "name": "SC_TCS_FanForceMode", "cn": "塔底水冷系统中有风扇开启了强制模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_070": { "name": "SC_TCS_HeaterManualMode", "cn": "塔底水冷加热器开启手动模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_071": { "name": "SC_TCS_HeaterForceMode", "cn": "塔底水冷加热器开启强制模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_072": { "name": "SC_TCS_MixingValveManualMode", "cn": "塔底水冷三通阀开启手动模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_073": { "name": "SC_TCS_MixingValveForceMode", "cn": "塔底水冷加热器开启强制模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_074": { "name": "SC_TCS_PumpInletPreSensorFault", "cn": "塔底水冷泵吸入侧压力传感器故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_075": { "name": "SC_TCS_PumpOutletPreSensorFault", "cn": "塔底水冷泵压力侧压力传感器故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_076": { "name": "SC_TCS_PumpOffAbnormally", "cn": "塔底水冷泵需启动但未启动", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#100ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_044": { "name": "SC_FaultPT100_GCC_Temp3", "cn": "变压器底部温度传感器1故障", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_11_045": { "name": "SC_FaultPT100_GCC_Temp4", "cn": "变压器底部温度传感器2故障", "subsystem": "GCC", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_077": { "name": "SC_FaultOutsideTowerHumidity", "cn": "塔筒外湿度传感器故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_078": { "name": "SC_FaultCabinetFloorHumidity", "cn": "塔底控制柜底部湿度传感器故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_079": { "name": "SC_FaultMixingValvePosition", "cn": "塔底水冷系统三通阀位置传感器故障", "subsystem": "CoolingSystem", "level": "170-故障停机", "reset_mode": "A", "type": "A", "alarm": "True", "set_delay": "T#10ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "100", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_080": { "name": "SC_CCC_Temp_MAX", "cn": "塔底水冷控制柜温度高故障", "subsystem": "CoolingSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_081": { "name": "SC_CCC_Temp_MIN", "cn": "塔底水冷控制柜温度低故障", "subsystem": "CoolingSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_082": { "name": "SC_CCC_Temp_High", "cn": "塔底水冷控制柜温度高警告", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_083": { "name": "SC_CCC_Temp_Low", "cn": "塔底水冷控制柜温度低警告", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_084": { "name": "SC_CCC_690VSupplyTripped", "cn": "塔底水冷系统690V供电跳开", "subsystem": "CoolingSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_085": { "name": "SC_CCC_NoUPS230VSupplyTripped", "cn": "塔底水冷系统230V(无UPS)供电跳开", "subsystem": "CoolingSystem", "level": "170-故障停机", "reset_mode": "M", "type": "F", "alarm": "True", "set_delay": "T#1s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_086": { "name": "SC_CCC_HeaterOrCoolerPowerTripped", "cn": "塔底水冷控制柜加热器或冷却器供电跳开", "subsystem": "CoolingSystem", "level": "40-警告待机", "reset_mode": "A", "type": "A", "alarm": "False", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "40", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_087": { "name": "SC_CCC_FaultPT100Temp", "cn": "塔底水冷控制柜PT100故障", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "F", "alarm": "True", "set_delay": "T#0s", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "51", "bp_runtime_2015": "170", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_088": { "name": "SC_CCC_HeaterManualMode", "cn": "塔底水冷控制柜加热器进入手动模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_089": { "name": "SC_CCC_HeaterForceMode", "cn": "塔底水冷控制柜加热器进入强制模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_090": { "name": "SC_CCC_CoolerManualMode", "cn": "塔底水冷控制柜风扇进入手动模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_091": { "name": "SC_CCC_CoolerForceMode", "cn": "塔底水冷控制柜风扇进入强制模式", "subsystem": "CoolingSystem", "level": "", "reset_mode": "A", "type": "I", "alarm": "False", "set_delay": "T#50ms", "powerup_delay": "T#0s", "repeat_n": "0", "repeat_period": "T#0s", "brake_state_design": "0", "bp_runtime_2015": "10", "src": "plc_dict_2014", "trigger_granularity": null, "detectable_in_10min": null }, "02_01_009": { "name": null, "cn": "变桨系统的400V主接触器未闭合", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_033": { "name": null, "cn": "塔架Z方向的瞬时加速度越限", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "02_04_036": { "name": null, "cn": "塔架Z方向的瞬时加速度告警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "02_08_010": { "name": null, "cn": "变频器测得发电机功率高于过高设定值", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "02_09_034": { "name": null, "cn": "高速液压刹车未释放", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "03_01_011": { "name": null, "cn": "风机保护性停机——自恢复执行中", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "185", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_020": { "name": null, "cn": "变频器急停按钮被拍下触发紧急停机", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_021": { "name": null, "cn": "机舱柜安全链回路24V保护空开跳开", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_022": { "name": null, "cn": "偏航黄盒子终极限位触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_023": { "name": null, "cn": "安全控制器测得低速端编码器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "175", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_01_024": { "name": null, "cn": "安全控制器测得高速端接近开关故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "175", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_143": { "name": null, "cn": "变桨超级电容正在充电", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "30", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_144": { "name": null, "cn": "变桨系统通信中断频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_145": { "name": null, "cn": "自复位变桨通信故障失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_146": { "name": null, "cn": "复位EL6751操作中", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "230", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_147": { "name": null, "cn": "变桨系统与主控的通讯故障频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_148": { "name": null, "cn": "变桨系统与主控的通讯故障自动复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_149": { "name": null, "cn": "1号轴控柜温度过高故障频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_150": { "name": null, "cn": "1号轴控柜温度过高故障自动复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_151": { "name": null, "cn": "2号轴控柜温度过高故障频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_152": { "name": null, "cn": "2号轴控柜温度过高故障自动复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_153": { "name": null, "cn": "3号轴控柜温度过高故障频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_154": { "name": null, "cn": "3号轴控柜温度过高故障自动复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_155": { "name": null, "cn": "1号变桨电机温度过高故障频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_156": { "name": null, "cn": "1号变桨电机温度过高故障自动复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_157": { "name": null, "cn": "2号变桨电机温度过高故障频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_158": { "name": null, "cn": "2号变桨电机温度过高故障自动复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_159": { "name": null, "cn": "3号变桨电机温度过高故障频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_160": { "name": null, "cn": "3号变桨电机温度过高故障自动复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_161": { "name": null, "cn": "1号后备电源柜温度过高故障频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_162": { "name": null, "cn": "1号后备电源柜温度过高故障自动复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_163": { "name": null, "cn": "2号后备电源柜温度过高故障频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_164": { "name": null, "cn": "2号后备电源柜温度过高故障自动复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_165": { "name": null, "cn": "3号后备电源柜温度过高故障频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_166": { "name": null, "cn": "3号后备电源柜温度过高故障自动复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_167": { "name": null, "cn": "中心柜温度过高故障频繁触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_02_168": { "name": null, "cn": "中心柜温度过高故障自动复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_016": { "name": null, "cn": "高速端转速IIR滤波后RMS值报警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_017": { "name": null, "cn": "高速端转速IIR滤波后RMS值停机", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_018": { "name": null, "cn": "高速端转速IIR滤波后RMS值报警重复出现", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_019": { "name": null, "cn": "低速端转速IIR滤波后RMS值报警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_020": { "name": null, "cn": "低速端转速IIR滤波后RMS值停机", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_021": { "name": null, "cn": "低速端转速IIR滤波后RMS值报警重复出现", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_022": { "name": null, "cn": "传动链频率检测正常", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_023": { "name": null, "cn": "传动链频率检测异常", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_024": { "name": null, "cn": "高速端转速的STD异常停机", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_025": { "name": null, "cn": "低速端转速的STD异常停机", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_026": { "name": null, "cn": "主轴承润滑MCB跳开", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_027": { "name": null, "cn": "主轴承润滑系统启动", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_028": { "name": null, "cn": "主轴承润滑系统加热器MCB跳开", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_029": { "name": null, "cn": "主轴承润滑系统加热器启动", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_030": { "name": null, "cn": "主轴承润滑系统未运行超过一星期", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_031": { "name": null, "cn": "主轴润滑泵开启手动模式", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_032": { "name": null, "cn": "主轴润滑泵开启强制模式", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_033": { "name": null, "cn": "主轴润滑泵加热器开启手动模式", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_034": { "name": null, "cn": "主轴润滑泵加热器开启强制模式", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_035": { "name": null, "cn": "低速端转速与发电机转速不匹配复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_036": { "name": null, "cn": "低速端转速与发电机转速不匹配重复出现", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_037": { "name": null, "cn": "主控系统测得的发电机转速与从变频器读得的不匹配复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_038": { "name": null, "cn": "主控系统测得的发电机转速与从变频器读得的不匹配重复出现", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_039": { "name": null, "cn": "低速端转速与发电机转速十分钟平均值不匹配", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_040": { "name": null, "cn": "低速端转速高于1级超速门限值复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_04_041": { "name": null, "cn": "发电机转速高于1级超速门限值复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_048": { "name": null, "cn": "齿轮箱弹性支撑达到极限载荷报警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_049": { "name": null, "cn": "齿轮箱弹性支撑失效报警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_050": { "name": null, "cn": "齿轮箱左扭力臂位置传感器损坏", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_051": { "name": null, "cn": "齿轮箱右扭力臂位置传感器损坏", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_05_052": { "name": null, "cn": "齿轮箱油泵过滤器滤网堵塞停机故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_092": { "name": null, "cn": "塔底水冷系统三通阀MCB跳开", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_093": { "name": null, "cn": "塔底水冷进水口水温过低故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_094": { "name": null, "cn": "塔底水冷三通阀实际位置与设置值不匹配", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_095": { "name": null, "cn": "塔底水冷塔内风扇1启动", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_096": { "name": null, "cn": "塔底水冷塔内风扇2启动", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_097": { "name": null, "cn": "塔底水冷塔外冷却器1风扇启动", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_098": { "name": null, "cn": "塔底水冷塔外冷却器2风扇启动", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_099": { "name": null, "cn": "塔底水冷塔外冷却器3风扇启动", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_100": { "name": null, "cn": "塔底水冷塔外冷却器4风扇启动", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_101": { "name": null, "cn": "机舱冷却系统有漏液风险", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_102": { "name": null, "cn": "塔底冷却系统有漏液风险", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_103": { "name": null, "cn": "机舱冷却系统泵1启动压差低报警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_104": { "name": null, "cn": "机舱冷却系统泵2启动压差低报警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_105": { "name": null, "cn": "塔底冷却系统泵出口压力过高警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_106": { "name": null, "cn": "塔底水冷进水口水温过低故障自复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_107": { "name": null, "cn": "塔底水冷进水口水温过低故障重复出现", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_108": { "name": null, "cn": "机舱水冷系统水冷泵站需启动但未启动", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_08_110": { "name": null, "cn": "塔底水冷控制柜温度过高或过低警告重复出现", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_050": { "name": null, "cn": "机舱前后振动带通滤波值报警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_051": { "name": null, "cn": "机舱前后振动带通滤波值停机", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_052": { "name": null, "cn": "机舱前后振动带通滤波值报警重复出现", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_053": { "name": null, "cn": "机舱左右振动带通滤波值报警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_054": { "name": null, "cn": "机舱左右振动带通滤波值停机", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_055": { "name": null, "cn": "机舱左右振动带通滤波值报警重复出现", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_056": { "name": null, "cn": "叶片面内振动超限报警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_057": { "name": null, "cn": "风轮不平衡报警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_060": { "name": null, "cn": "切换至备用风速仪", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_061": { "name": null, "cn": "PCH的通讯状态为\"Node not found\"", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_09_062": { "name": null, "cn": "发送重启PCH信号", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_015": { "name": null, "cn": "偏航摩擦片润滑系统(2L)油脂底", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_016": { "name": null, "cn": "偏航摩擦片润滑系统(2L)堵塞", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_017": { "name": null, "cn": "偏航传感器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_018": { "name": null, "cn": "偏航速度异常,不在有效区间内", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_10_019": { "name": null, "cn": "偏航速度计算自检", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_028": { "name": null, "cn": "变频器EtherCAT通讯故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_029": { "name": null, "cn": "变频器双通道同步故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_030": { "name": null, "cn": "变频器Fastlink故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_031": { "name": null, "cn": "变频器Watchdog错误", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_032": { "name": null, "cn": "变频器FaultLoop故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_033": { "name": null, "cn": "变频器I2TFault", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_034": { "name": null, "cn": "变频器sharing故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_035": { "name": null, "cn": "变频器DB故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_036": { "name": null, "cn": "变频器水冷故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_037": { "name": null, "cn": "变频器烟感报警", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_038": { "name": null, "cn": "变频器主CB故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_039": { "name": null, "cn": "变频器机侧CB故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_040": { "name": null, "cn": "变频器主PWM滤波器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_041": { "name": null, "cn": "变频器预充电回路故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_042": { "name": null, "cn": "变频器网侧DIBe1故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_043": { "name": null, "cn": "变频器网侧DIBe2故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_044": { "name": null, "cn": "变频器网侧DIBe3故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_045": { "name": null, "cn": "变频器网侧DIBe4故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_046": { "name": null, "cn": "变频器机侧DIBe1故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_047": { "name": null, "cn": "变频器机侧DIBe2故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_048": { "name": null, "cn": "变频器机侧DIBe3故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_049": { "name": null, "cn": "变频器机侧DIBe4故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_050": { "name": null, "cn": "变频器报直流母线故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_051": { "name": null, "cn": "变频器PIBe故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_052": { "name": null, "cn": "变频器机侧防雷故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_053": { "name": null, "cn": "变频器报电机相关故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_054": { "name": null, "cn": "变频器报电网相关故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_055": { "name": null, "cn": "变频器报编码器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_056": { "name": null, "cn": "变频器固件不匹配", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_057": { "name": null, "cn": "变频器报过速故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_058": { "name": null, "cn": "变频器电机控制故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_059": { "name": null, "cn": "变频器报急停", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_060": { "name": null, "cn": "变频器电压检测板故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_061": { "name": null, "cn": "变频器机侧熔丝故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_062": { "name": null, "cn": "变频器报告警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_063": { "name": null, "cn": "变频器CAN通讯闪断", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_064": { "name": null, "cn": "变频器CAN通讯长断", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "50", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_065": { "name": null, "cn": "变频器CAN通讯闪断重复触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "175", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_066": { "name": null, "cn": "变频器CAN通讯自复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "175", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_067": { "name": null, "cn": "变频器CAN通讯长断重复触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "175", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_068": { "name": null, "cn": "变频柜空调电源故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_069": { "name": null, "cn": "变频器直流母线充电超时重复触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "175", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_070": { "name": null, "cn": "变频器直流母线充电超时自复位失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "175", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_071": { "name": null, "cn": "主从配置正在进行", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_072": { "name": null, "cn": "GEPC变频器报告警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_073": { "name": null, "cn": "变频器报告警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_074": { "name": null, "cn": "变频器报告冷却故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_075": { "name": null, "cn": "扭矩设定值与真实值的偏差过大", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_076": { "name": null, "cn": "变频器SDO通讯超时", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_101": { "name": null, "cn": "ABB变频器机侧IGBT故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_102": { "name": null, "cn": "ABB变频器机侧模块故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_103": { "name": null, "cn": "ABB变频器机侧电流异常故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_104": { "name": null, "cn": "ABB变频器直流母线故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_105": { "name": null, "cn": "ABB变频器充电回路故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_106": { "name": null, "cn": "ABB变频器机侧控制器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_107": { "name": null, "cn": "ABB变频器LSU故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_108": { "name": null, "cn": "ABB变频器LSU风扇故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_109": { "name": null, "cn": "ABB变频器冷却系统故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_110": { "name": null, "cn": "ABB变频器风扇故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_111": { "name": null, "cn": "ABB变频器机侧模块风扇故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_112": { "name": null, "cn": "ABB变频器机侧模块通讯故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_113": { "name": null, "cn": "ABB变频器机侧EFB故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_114": { "name": null, "cn": "ABB变频器机侧通讯故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_115": { "name": null, "cn": "ABB变频器电机侧故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_116": { "name": null, "cn": "ABB变频器变频器温度故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_117": { "name": null, "cn": "ABB变频器STO故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_118": { "name": null, "cn": "ABB变频器测量监控信号故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_119": { "name": null, "cn": "ABB变频器动态刹车故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_120": { "name": null, "cn": "ABB变频器机械刹车故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_121": { "name": null, "cn": "ABB变频器急停信号异常故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_122": { "name": null, "cn": "ABB变频器转速信号故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_123": { "name": null, "cn": "ABB变频器FSO故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_124": { "name": null, "cn": "ABB变频器机侧电缆异常故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_125": { "name": null, "cn": "ABB变频器其他故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_126": { "name": null, "cn": "ABB变频器机侧外部故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_127": { "name": null, "cn": "ABB变频器网侧IGBT故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_128": { "name": null, "cn": "ABB变频器网侧模块故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_129": { "name": null, "cn": "ABB变频器网侧电流故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_130": { "name": null, "cn": "ABB变频器电网故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_131": { "name": null, "cn": "ABB变频器网侧控制器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_132": { "name": null, "cn": "ABB变频器网侧模块通讯故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_133": { "name": null, "cn": "ABB变频器EFB通讯故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_134": { "name": null, "cn": "ABB变频器网侧通讯故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_135": { "name": null, "cn": "ABB变频器网侧外部故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_136": { "name": null, "cn": "ABB变频器网侧电缆异常故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_137": { "name": null, "cn": "ABB变频器断路器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_138": { "name": null, "cn": "ABB变频器水冷系统故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_139": { "name": null, "cn": "ABB变频器故障停机", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_12_140": { "name": null, "cn": "ABB变频器未拆分故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_010": { "name": null, "cn": "塔底控制柜左侧温度传感器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_011": { "name": null, "cn": "塔底控制柜右侧温度传感器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_012": { "name": null, "cn": "塔底690V防雷器触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_013": { "name": null, "cn": "塔底400V防雷器触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_014": { "name": null, "cn": "塔底230V防雷器触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_015": { "name": null, "cn": "机舱690V防雷器触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_016": { "name": null, "cn": "机舱400V防雷器触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_017": { "name": null, "cn": "机舱230V防雷器触发", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_018": { "name": null, "cn": "塔底柜24V电源冗余失效", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_019": { "name": null, "cn": "机舱柜24V电源冗余失效", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_020": { "name": null, "cn": "塔底柜左侧加热器与通风风扇230V供电开关断开", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_021": { "name": null, "cn": "塔底柜右侧加热器与冷却风扇230V供电开关断开", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_022": { "name": null, "cn": "机舱柜通风风扇230V供电开关断开", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_023": { "name": null, "cn": "机舱柜加热器230V供电开关断开", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_13_024": { "name": null, "cn": "风机尚有问题禁止离开", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_020": { "name": null, "cn": "IPC45度传感器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_021": { "name": null, "cn": "IPC135度传感器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_022": { "name": null, "cn": "IPC225度传感器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_15_023": { "name": null, "cn": "IPC315度传感器故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_16_016": { "name": null, "cn": "启动模式运行超时重复", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_038": { "name": null, "cn": "读取统计量参数文件失败警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_039": { "name": null, "cn": "读取个性化参数文件失败警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_040": { "name": null, "cn": "读取通用性参数文件失败警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_041": { "name": null, "cn": "读取掉电保存变量文件失败警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_042": { "name": null, "cn": "存储统计量参数文件失败警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_043": { "name": null, "cn": "存储个性化参数文件失败警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_044": { "name": null, "cn": "存储通用性参数文件失败警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_045": { "name": null, "cn": "存储掉电保存变量文件失败警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_046": { "name": null, "cn": "存储掉电保存变量文件失败故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_047": { "name": null, "cn": "存储统计量参数文件失败故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_048": { "name": null, "cn": "存储个性化参数文件失败故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_049": { "name": null, "cn": "存储通用性参数文件失败故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_050": { "name": null, "cn": "读取掉电保存变量文件失败故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_051": { "name": null, "cn": "读取统计量参数文件失败故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_052": { "name": null, "cn": "读取个性化参数文件失败故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_053": { "name": null, "cn": "读取存储通用性参数文件失败故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_054": { "name": null, "cn": "Ethercat通讯故障自恢复", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "230", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_055": { "name": null, "cn": "Ethercat故障自恢复失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "175", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_056": { "name": null, "cn": "Ethercat故障重复出现", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "175", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_057": { "name": null, "cn": "EtherCAT冗余网线连接故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_058": { "name": null, "cn": "EtherCat模块通讯断开", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "175", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_059": { "name": null, "cn": "EtherCAT通讯建立失败", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "175", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_060": { "name": null, "cn": "EtherCAT通讯环网重组", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "10", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_21_061": { "name": null, "cn": "EtherCAT通讯环网重组警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "165", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_29_001": { "name": null, "cn": "齿轮箱颗粒检测装置异常", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_29_002": { "name": null, "cn": "齿轮箱颗粒检测数量异常警告", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "40", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_29_003": { "name": null, "cn": "齿轮箱颗粒检测数量异常故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "170", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_29_004": { "name": null, "cn": "Acoem CMS通讯故障", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_29_005": { "name": null, "cn": "Acoem CMS多次触发危险值", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_29_006": { "name": null, "cn": "前主轴承报警值超限", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_29_007": { "name": null, "cn": "后主轴承报警值超限", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_29_008": { "name": null, "cn": "齿轮箱报警值超限", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_29_009": { "name": null, "cn": "发电机驱动端报警值超限", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "04_29_010": { "name": null, "cn": "发电机非驱动端报警值超限", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null }, "sc04_04_044": { "name": null, "cn": "主轴承润滑系统加热器未运行一周", "subsystem": null, "level": null, "reset_mode": null, "type": null, "alarm": null, "set_delay": null, "powerup_delay": null, "repeat_n": null, "repeat_period": null, "brake_state_design": "", "bp_runtime_2015": null, "src": "scada_lang_2015", "trigger_granularity": null, "detectable_in_10min": null } }, "params_never_referenced_by_any_code": [ "PAR_CVT_CANOpen_AmsNetId", "PAR_CVT_CANOpen_PortNr", "PAR_Gen_CoilTempHigh", "PAR_Gen_CoilTempLow", "PAR_Gen_RatedPower", "PAR_Gen_ReducedPower", "PAR_PowerLimitFromSCADA", "PAR_TempForTurbineColdStart", "PAR_TempForTurbineNormalStart", "PAR_VoltageRatioForUMG103", "PAR_YBox_CANOpen_AmsNetId", "PAR_YBox_CANOpen_PortNr", "PAR_bAVRConverterOn", "PAR_bAVRPowerPriority", "PAR_bAutoRestartFromGridFailure", "PAR_bBatteryVoltSendProtocol", "PAR_bCCTempReduEnabled", "PAR_bCS_EnableWaterLeakMonitor", "PAR_bCableWithTempSensor", "PAR_bConPowerReduEnabled", "PAR_bCutInShopFloorTest", "PAR_bDefectFreeCabinet", "PAR_bDisableOverPower", "PAR_bEnable24ReduMonitor", "PAR_bEnableAutoRebootPLC", "PAR_bEnableBladeZeroPositionFunction", "PAR_bEnableCheckOfRemoteReset", "PAR_bEnableGearboxPowerReduction", "PAR_bEnableMetalScanSensor", "PAR_bEnableMianShaftCrackDetect", "PAR_bEnablePLCWatchdog", "PAR_bEnablePowerReduByGenerator", "PAR_bEnablePowerValueLimit", "PAR_bEnableSPDMonitor", "PAR_bEnableSelfTest", "PAR_bEnableSelftest1", "PAR_bEnableSelftest2", "PAR_bEnableSelftest3", "PAR_bEnableSelftest4", "PAR_bEnableSelftest5", "PAR_bEnableSpeedSpikeFilter", "PAR_bEnableWindCalibration", "PAR_bEnableWindIrisAutoControlMode", "PAR_bEnableWindIrisManualControlMode", "PAR_bEncoderGenSpeedFromFreq", "PAR_bEncoderRotorSpeedFromFreq", "PAR_bFFTStopPowerReductionEnable", "PAR_bFFTWarningPowerReductionEnable", "PAR_bFFTWarningSpeedReductionEnable", "PAR_bGBX_EnableFuseHeater_GearOilPipe", "PAR_bGBX_OilFilter_Enable", "PAR_bGJ_EnableBadDataDetect", "PAR_bGenSpeedFromConverter", "PAR_bGenWithTempInOutlet", "PAR_bHeaterControlByEnvision_WCS", "PAR_bHydrPumpControlledBySwitch", "PAR_bIGBTTempReduEnabled", "PAR_bNAC_EnableHeaterFunction", "PAR_bPCH_EnableBadDataDetect", "PAR_bPCH_HubEnableBadDataDetect", "PAR_bPowerProcessFromConverter", "PAR_bReleaseFunction_PitchMotorStop", "PAR_bSectorReduEnabled", "PAR_bSelectDiffYawStrategy", "PAR_bSelectGenSpeedFromEncoder", "PAR_bSelectReactivePowerSetPointFromWindFarm", "PAR_bSpecialUPSForCT", "PAR_bStartWindIris", "PAR_bSwitchPhiOrReactivePowerCmd", "PAR_bTCSFeedforwardControlON", "PAR_bTCS_EnableWaterLeakMonitor", "PAR_bUseWindIris", "PAR_bWindfarmControlEnable", "PAR_bWinergyGearboxOilInletNoPT100", "PAR_bYawEncoderByCANOpen", "PAR_bYawPositionReversed", "PAR_gbyCountryCode", "PAR_gbyTurbineNumber", "PAR_gsCompanyCode", "PAR_gsTurbineType", "PAR_gsWindPark", "PAR_i5DaysElapsed", "PAR_iAddEtherCAT_GCC_BK1250", "PAR_iAddEtherCAT_Nacelle_BK1120_1", "PAR_iAddEtherCAT_Nacelle_BK1120_2", "PAR_iAddEtherCAT_Nacelle_BK1250", "PAR_iAddEtherCAT_Tower_BK1250", "PAR_iCANConverterTimeoutLevel1FaultCount", "PAR_iCANConverterTimeoutLevel2FaultCount", "PAR_iCVT1CANAddress", "PAR_iCVT2CANAddress", "PAR_iCabinetVersion", "PAR_iConverterType", "PAR_iConverter_DCLinkChargeTimeOutFaultCount", "PAR_iCoolingSystemType", "PAR_iDriveTrainType", "PAR_iDrivetrainFaultRepeatRate", "PAR_iEthercatDevicesNumber", "PAR_iEthercatRepeatRate", "PAR_iFireAlarmType", "PAR_iGCCType", "PAR_iGearBoxType", "PAR_iGearOilFilterOffLineControlStrategy", "PAR_iGearOilFilterOffLine_CheckCycle", "PAR_iGearOilFilterOffLine_CheckDate", "PAR_iGearOilFilterPresureCheckDelayTime", "PAR_iGenType", "PAR_iGridMeasureType", "PAR_iHydraulicType", "PAR_iLIDARSensorType", "PAR_iMainBearingLubType", "PAR_iMeteoWindSensorCtrlMode", "PAR_iNacelleType", "PAR_iNacelleVibrationSensorType", "PAR_iPCH_HubType", "PAR_iPercentOfYawMinimumTime_HighWindSpeed", "PAR_iPercentOfYawMinimumTime_LowWindSpeed", "PAR_iPitchCANAddress", "PAR_iPitchFaultRepeatRateLevel1", "PAR_iPitchFaultRepeatRateLevel2", "PAR_iPitchSystemType", "PAR_iRebootPLCMaxNum", "PAR_iResetCheck_Limit", "PAR_iResetCheck_Period", "PAR_iRotorBrakeType", "PAR_iRotorLockType", "PAR_iSafetySystemType", "PAR_iTowerCoolingSystemType", "PAR_iTraceLogType", "PAR_iTurbineType", "PAR_iUPSTime_Min", "PAR_iWindSingalType", "PAR_iYawGreaseType", "PAR_iYawNewStrategy", "PAR_iYawSystemType", "PAR_rAccelLimit2OmniDirection", "PAR_rAccumulatorPressureLowerLimit", "PAR_rAccumulatorPressureUpperLimit", "PAR_rAirPressureSignalMax", "PAR_rAirPressureSignalMin", "PAR_rAnglePitchNotFollow", "PAR_rAsynPitchAngle_Level1", "PAR_rAsynPitchAngle_Level2", "PAR_rBandFilterNacelleForaftVibrationAlarm", "PAR_rBandFilterNacelleForaftVibrationFault", "PAR_rBandFilterNacelleForaftVibrationNormal", "PAR_rBandFilterNacelleSideSideVibrationAlarm", "PAR_rBandFilterNacelleSideSideVibrationFault", "PAR_rBandFilterNacelleSideSideVibrationNormal", "PAR_rBladeEncoderDefect", "PAR_rBladeZeroPositionInsideOffsetWarning", "PAR_rBladeZeroPositionOutsideOffsetWarning", "PAR_rBrakePressureHighUnderProduction", "PAR_rCCC_LowerTempHyst", "PAR_rCCC_TempHigh", "PAR_rCCC_TempLow", "PAR_rCCC_TempMAX", "PAR_rCCC_TempMIN", "PAR_rCCC_TempStartCooling", "PAR_rCCC_TempStartHeating", "PAR_rCCC_TempStopCooling", "PAR_rCCC_TempStopHeating", "PAR_rCCC_UpperTempHyst", "PAR_rCC_TempHigh_Derate_Start", "PAR_rCC_TempHigh_Derate_Stop", "PAR_rCC_TempHigh_ReducedPower", "PAR_rCC_Temp_High", "PAR_rCC_Temp_Low", "PAR_rCC_Temp_Low_Restart", "PAR_rCC_Temp_VeryHigh", "PAR_rCS_MAXPreDescendRate", "PAR_rCS_PumpInletPressureSignalMax", "PAR_rCS_PumpInletPressureSignalMin", "PAR_rCS_PumpMINPressureErr", "PAR_rCS_PumpOutletPressureSignalMax", "PAR_rCS_PumpOutletPressureSignalMin", "PAR_rCS_TempCoefficient", "PAR_rCVTPositionFollow_DeadBand", "PAR_rCVTSpeedMode_MaxAcceleration", "PAR_rCVTSpeedMode_MaxSpeedSetValue", "PAR_rCVTSpeedMode_MaxWindSpeed", "PAR_rCVTSpeedMode_MinSpeedSetValue", "PAR_rCVTWaterCoolInOutPressureDiffHigh", "PAR_rCVTWaterCoolInOutPressureDiffLow", "PAR_rCVT_IGBT_TempHigh_Derate_Start", "PAR_rCVT_IGBT_TempHigh_Derate_Stop", "PAR_rCVT_IGBT_TempHigh_ReducedPower", "PAR_rCVT_LowerTempHyst", "PAR_rCVT_UpperTempHyst", "PAR_rCabinet_LowerTempHyst", "PAR_rCabinet_UpperTempHyst", "PAR_rCoreControllerMaxPitchAngle", "PAR_rCosPhiSetPointValue", "PAR_rCouplingSlipDetect", "PAR_rDecreaseTempDisableGBXOilSumpHeater", "PAR_rDecreaseTempEnableGBXOilSumpHeater", "PAR_rDiffNacelleDisableNacelleHeating", "PAR_rDiffNacelleEnableNacelleHeating", "PAR_rDiffOverspeedRelayDetectFail", "PAR_rDiffYawTrackingFastReaction", "PAR_rDiffYawTrackingSlowReaction", "PAR_rFFTPowerReductionFactor", "PAR_rFFTPowerReductionLowerLimit", "PAR_rFFTSpeedlimitation", "PAR_rFFTSpeedlimitationFactor", "PAR_rFFTStopPowerReductionLevel", "PAR_rGBXBearingPowerLimitPowerHigh", "PAR_rGBXBearingPowerLimitPowerLow", "PAR_rGBXOilPowerLimitPowerHigh", "PAR_rGBXOilPowerLimitPowerLow", "PAR_rGBXOilPumpMotorPreheaterDisableTemp", "PAR_rGBXOilPumpMotorPreheaterEnableTemp", "PAR_rGBXTempHysteresisLowerTemp", "PAR_rGBXTempHysteresisUpperTemp", "PAR_rGBXTorqueArmPositionAlarm", "PAR_rGBXTorqueArmPositionMax", "PAR_rGBXTorqueArmPositionMin", "PAR_rGBXTorqueArmPositionNormal", "PAR_rGBXTorqueArmPositionWarming", "PAR_rGBX_OilFilter_EndTemp", "PAR_rGBX_OilFilter_StartTemp", "PAR_rGBX_OilFilter_StopTemp", "PAR_rGBX_OilFilter_TempHysteresis", "PAR_rGCC_Temp_High", "PAR_rGCC_Temp_Low", "PAR_rGCC_Temp_Low_Restart", "PAR_rGCC_Temp_VeryHigh", "PAR_rGENCoilTempDiffMAX", "PAR_rGEN_NacelleTempToStartFan", "PAR_rGEN_StatorTempDiffMAX", "PAR_rGEN_StatorTempToStartFan", "PAR_rGLGenWaterCool_InletPressureSignalMax", "PAR_rGLGenWaterCool_InletPressureSignalMin", "PAR_rGLGenWaterCool_OutletPressureSignalMax", "PAR_rGLGenWaterCool_OutletPressureSignalMin", "PAR_rGearOilDiffPressureInlineFilterMax", "PAR_rGearOilDiffPressureInlineFilterMin", "PAR_rGearOilFilterInletPressSignalMax", "PAR_rGearOilFilterInletPressSignalMin", "PAR_rGearOilGBXInletPressSignalMax", "PAR_rGearOilGBXInletPressSignalMin", "PAR_rGearOilPressure_MIN", "PAR_rGearOilPressure_MIN_PumpHS", "PAR_rGearOilPressure_MIN_PumpLS", "PAR_rGenRPMSwitchPumpMode_LS", "PAR_rGenSpeedBandStartMode", "PAR_rGenSpeedBelowMainBrakeON", "PAR_rGenSpeedForConverterRdy_Run", "PAR_rGenSpeedForGBXOilPump", "PAR_rGenSpeedForWindValidation", "PAR_rGenSpeedOfHSBrakeFinish", "PAR_rGenSpeedSetValueBrakeMode50", "PAR_rGenSpeedStartMode", "PAR_rGenSpeedToCheckConverterSpeedOK", "PAR_rGenSpeed_GearboxHeaterOFF", "PAR_rGenSpeed_GearboxHeaterON", "PAR_rGenWaterCoolInOutPressureDiffHigh", "PAR_rGenWaterCoolInOutPressureDiffLow", "PAR_rGeneratorNominalTorque", "PAR_rGridFrequencyHigh_Hz", "PAR_rGridFrequencyLow_Hz", "PAR_rHVRTVolLevel1Multiplier", "PAR_rHVRTVolLevel2Multiplier", "PAR_rHighYawDegree_Sector1", "PAR_rHighYawDegree_Sector2", "PAR_rHighYawDegree_Sector3", "PAR_rHighYawDegree_Sector4", "PAR_rHydSystemPressMIN_Stop", "PAR_rHydSystemPressMainCircuitMIN_Stop", "PAR_rHydrAccuBrakePressSignalMax", "PAR_rHydrAccuBrakePressSignalMin", "PAR_rHydrAccuPreChargePressSignalMax", "PAR_rHydrAccuPreChargePressSignalMin", "PAR_rHydrAccuSumpPressSignalMax", "PAR_rHydrAccuSumpPressSignalMin", "PAR_rHystYawDegree_Sector", "PAR_rIncreaseTempDisableGBXOilSumpHeater", "PAR_rIncreaseTempEnableGBXOilSumpHeater", "PAR_rKpGenSpeedPT2Filter", "PAR_rLifeSignFrequencyWindfarmCom", "PAR_rLowYawDegree_Sector1", "PAR_rLowYawDegree_Sector2", "PAR_rLowYawDegree_Sector3", "PAR_rLowYawDegree_Sector4", "PAR_rMainShaftCrackAlarmRPMDiff", "PAR_rMarginForGenPDMTimeoutDetect", "PAR_rMarginForRotorPDMTimeoutDetect", "PAR_rMarginSensorOutOfRange", "PAR_rMaxDiffSetAndSensorsBladeAngle_PitchLimit3", "PAR_rMaxDiffSetAndSensorsBladeAngle_PitchLimit4", "PAR_rMaxDiffZeroPos", "PAR_rMaxGenSpeedAtBrakeTest", "PAR_rMaxGeneratorTorque", "PAR_rMaxNacelleHumidity", "PAR_rMaxPitchAccelleration", "PAR_rMaxPitchAngleForLimit91", "PAR_rMaxPitchAngleForLimit95", "PAR_rMaxPitchSpeed", "PAR_rMaxPower100ms", "PAR_rMaxWindSpeedByPitchAngle_30sec", "PAR_rMinGeneratorTorque", "PAR_rMinPitchAngleForLimit91", "PAR_rMinPitchAngleForLimit95", "PAR_rMinPitchAngleSector1", "PAR_rMinPitchAngleSector2", "PAR_rMinPitchAngleSector3", "PAR_rMinPitchAngleSector4", "PAR_rMinPitchSpeed", "PAR_rMinSpeedToCalcSpeedByPDM", "PAR_rNacelleTempEnableNacelleHeating", "PAR_rNacelleTempHysteresisLowerTemp", "PAR_rNacelleTempHysteresisUpperTemp", "PAR_rOffsetActiveEnergyConsum", "PAR_rOffsetActiveEnergyOverall", "PAR_rOffsetOfOverSpeedForLVRT", "PAR_rOffsetOfVibrationForLVRT", "PAR_rOffsetPitchAngle1Blade1", "PAR_rOffsetPitchAngle1Blade2", "PAR_rOffsetPitchAngle1Blade3", "PAR_rOffsetPitchAngle2Blade1", "PAR_rOffsetPitchAngle2Blade2", "PAR_rOffsetPitchAngle2Blade3", "PAR_rOffsetReactiveEnergyConsum", "PAR_rOffsetReactiveEnergyOverall", "PAR_rOffsetVane1", "PAR_rOffsetVane2", "PAR_rOffset_Azimuth_Position_Rotor", "PAR_rOutsideTempDisableNacelleHeating", "PAR_rOutsideTempEnableNacelleHeating", "PAR_rOverspeedRelayDetectFailSignalMax", "PAR_rOverspeedRelayDetectFailSignalMin", "PAR_rPCH_HubFFTAlarmResetValue", "PAR_rPCH_HubFFTAlertValue", "PAR_rPCH_HubFFTDangerValue", "PAR_rPCH_HubPPAlarmResetValue", "PAR_rPCH_HubPPAlertValue", "PAR_rPCH_HubPPDangerValue", "PAR_rPCH_HubPeakAlarmResetValue", "PAR_rPCH_HubPeakAlertValue", "PAR_rPCH_HubPeakDangerValue", "PAR_rPitchAngleSelftest1", "PAR_rPitchAngleSelftest2", "PAR_rPitchAngleSetValueBrakeMode50", "PAR_rPitchAxisBoxMaxTemp", "PAR_rPitchAxisBoxMinTemp", "PAR_rPitchBackupMaxTemp", "PAR_rPitchBackupMaxVolt", "PAR_rPitchBackupMinTemp", "PAR_rPitchBackupMinVolt", "PAR_rPitchDeadZoneForSelftest2", "PAR_rPitchHVRT_Level1", "PAR_rPitchHVRT_Level2", "PAR_rPitchHubMaxTemp", "PAR_rPitchHubMinTemp", "PAR_rPitchLBAMaxTemp", "PAR_rPitchLBAMinTemp", "PAR_rPitchMotorMaxTemp", "PAR_rPitchMotorMinTemp", "PAR_rPowerLimitDownRateSector", "PAR_rPowerLimitSector1", "PAR_rPowerLimitSector2", "PAR_rPowerLimitSector3", "PAR_rPowerLimitSector4", "PAR_rPowerLimitUpRateSector", "PAR_rPowerLimitationMargin", "PAR_rPowerLimitationMarginOffset", "PAR_rPreMAX_WCSOfCon", "PAR_rPreMAX_WCSOfGen", "PAR_rPreMIN_WCSOfCon", "PAR_rPreMIN_WCSOfGen", "PAR_rPulsesPerGeneratorRotation", "PAR_rPulsesPerRotorRotation", "PAR_rRMSHighSpeedAlarm", "PAR_rRMSHighSpeedNormal", "PAR_rRMSHighSpeedWarning", "PAR_rRMSLowSpeedAlarm", "PAR_rRMSLowSpeedNormal", "PAR_rRMSLowSpeedWarning", "PAR_rRPMLimitDownRateSector", "PAR_rRPMLimitSector1", "PAR_rRPMLimitSector2", "PAR_rRPMLimitSector3", "PAR_rRPMLimitSector4", "PAR_rRPMLimitUpRateSector", "PAR_rReactivePowerSetPointValue", "PAR_rRotorLockPushOutPressureHyst", "PAR_rRotorLock_PushOutPressureSignalMax", "PAR_rRotorLock_PushOutPressureSignalMin", "PAR_rRotorPosOffset", "PAR_rRotorSpeed_N_Check", "PAR_rRotorSpeed_N_Hyst", "PAR_rRuntimeSelftest1", "PAR_rSTD_GenSpeed_Normal", "PAR_rSTD_GenSpeed_VeryHigh", "PAR_rSTD_RotorSpeed_Normal", "PAR_rSTD_RotorSpeed_VeryHigh", "PAR_rScalingFactorEncPos", "PAR_rScalingFactorGenActivePower", "PAR_rScalingFactorGenPosition", "PAR_rScalingFactorGenSpeed", "PAR_rScalingFactorGenTorque", "PAR_rScalingFactorPhi", "PAR_rScalingFactorReactivePower", "PAR_rSelftestMaxWindspeed", "PAR_rSetValueRPMatNominalPower", "PAR_rShutDownFastForLowPower", "PAR_rSimLVRTTorque", "PAR_rSlipCriticallyDegree", "PAR_rSpeedDiffForSlipBegin", "PAR_rSpeedDiffForSlipEnd", "PAR_rSpeedOKForCVTDetection", "PAR_rStartCabinetHeater", "PAR_rSumPitchStartToCAGEMode", "PAR_rSumPitchStartToDFIGMode", "PAR_rSwitchPumpHours", "PAR_rSystemPressureMainCircuitSTART_HydrPump", "PAR_rSystemPressureMainCircuitSTOP_HydrPump", "PAR_rSystemPressureStart_HydrPump", "PAR_rSystemPressureStop_HydrPump", "PAR_rTCS_ECF_AirTemp_Level1_Disable", "PAR_rTCS_ECF_AirTemp_Level1_Enable", "PAR_rTCS_ECF_AirTemp_Level2_Disable", "PAR_rTCS_ECF_AirTemp_Level2_Enable", "PAR_rTCS_ECF_AirTemp_Level3_Disable", "PAR_rTCS_ECF_AirTemp_Level3_Enable", "PAR_rTCS_ECF_AirTemp_Level4_Disable", "PAR_rTCS_ECF_AirTemp_Level4_Enable", "PAR_rTCS_ECF_Disabled_Time_Min", "PAR_rTCS_ECF_Enabled_Time_Min", "PAR_rTCS_ECF_WaterTemp_Level1_Disable", "PAR_rTCS_ECF_WaterTemp_Level1_Enable", "PAR_rTCS_ECF_WaterTemp_Level2_Disable", "PAR_rTCS_ECF_WaterTemp_Level2_Enable", "PAR_rTCS_ECF_WaterTemp_Level3_Disable", "PAR_rTCS_ECF_WaterTemp_Level3_Enable", "PAR_rTCS_ECF_WaterTemp_Level4_Disable", "PAR_rTCS_ECF_WaterTemp_Level4_Enable", "PAR_rTCS_ICF_AirTemp_Disable", "PAR_rTCS_ICF_AirTemp_Enable", "PAR_rTCS_MAXPreDescendRate", "PAR_rTCS_MaxTowerAirTemp", "PAR_rTCS_MixingValveMaxDiff", "PAR_rTCS_MixingValveMoveMINDiff", "PAR_rTCS_MixingValveMoveSpeed", "PAR_rTCS_OffsetTempInsideCooler", "PAR_rTCS_PID_AcceptErr", "PAR_rTCS_PID_CtrlCycleTime", "PAR_rTCS_PID_CutInErr", "PAR_rTCS_PID_DeadZoneCutOut", "PAR_rTCS_PID_Para_D_1", "PAR_rTCS_PID_Para_D_2", "PAR_rTCS_PID_Para_D_3", "PAR_rTCS_PID_Para_D_Damp", "PAR_rTCS_PID_Para_I_1", "PAR_rTCS_PID_Para_I_2", "PAR_rTCS_PID_Para_I_3", "PAR_rTCS_PID_Para_P_1", "PAR_rTCS_PID_Para_P_2", "PAR_rTCS_PID_Para_P_3", "PAR_rTCS_PumpInletPressureSignalMax", "PAR_rTCS_PumpInletPressureSignalMin", "PAR_rTCS_PumpInletPressureTooLow", "PAR_rTCS_PumpMINPressureErr", "PAR_rTCS_PumpOutletPreHigh", "PAR_rTCS_PumpOutletPressureSignalMax", "PAR_rTCS_PumpOutletPressureSignalMin", "PAR_rTCS_TempCoefficient", "PAR_rTCS_TowerTempHigh", "PAR_rTCS_TowerTempTooHigh", "PAR_rTCS_WaterInletTempLowWarning", "PAR_rTempDIFFHeaterCabinetsON", "PAR_rTempDiffFrontAndRearBearing", "PAR_rTempDisableGBXOilPumpHS", "PAR_rTempDisableGBXOilPumpLS", "PAR_rTempDriveTrainHysteresis", "PAR_rTempEnableGBXOilPumpHS", "PAR_rTempEnableGBXOilPumpLS", "PAR_rTempGBXBearingHSSHigh", "PAR_rTempGBXBearingHSSMax", "PAR_rTempGBXBearingIMSHigh", "PAR_rTempGBXBearingIMSMax", "PAR_rTempGearOilFilterMonitor", "PAR_rTempGearOilLevelMoniter", "PAR_rTempGearOilPump_HS_ON", "PAR_rTempGearOilPump_LS_ON", "PAR_rTempGearboxHeatingMode", "PAR_rTempGearbox_BearingNDE_FanHS_OFF", "PAR_rTempGearbox_BearingNDE_FanHS_ON", "PAR_rTempGearbox_BearingNDE_FanLS_OFF", "PAR_rTempGearbox_BearingNDE_FanLS_ON", "PAR_rTempGearbox_HeaterON", "PAR_rTempGearbox_OilSink_FanHS_OFF", "PAR_rTempGearbox_OilSink_FanHS_ON", "PAR_rTempGearbox_OilSink_FanLS_OFF", "PAR_rTempGearbox_OilSink_FanLS_ON", "PAR_rTempGenHysteresis", "PAR_rTempGenStatorHeaterMIN", "PAR_rTempHigh_GearBearingInterDE", "PAR_rTempHigh_GearBearingInterNDE", "PAR_rTempHysteresisGenStatorHeaterHigh", "PAR_rTempHysteresisGenStatorHeaterLow", "PAR_rTempHysteresisNacelleTemp", "PAR_rTempHysteresisToDisableOverPower", "PAR_rTempLow_CabinetNacelle", "PAR_rTempLow_RotorBearingA", "PAR_rTempMAX_GearBearingInterDE", "PAR_rTempMAX_GearBearingInterNDE", "PAR_rTempMAX_WCSOfCon", "PAR_rTempMAX_WCSOfGen", "PAR_rTempMIN_RotorBearingA", "PAR_rTempMIN_WCSOfCon", "PAR_rTempMIN_WCSOfGen", "PAR_rTempNacelle_NacelleInletDamperDisable", "PAR_rTempNacelle_NacelleInletDamperEnable", "PAR_rTempNacelle_NacelleOutletDamperDisable", "PAR_rTempNacelle_NacelleOutletDamperEnable", "PAR_rTempNacelle_NacelleOutletFanDisable", "PAR_rTempNacelle_NacelleOutletFanEnable", "PAR_rTempOutdoorOutOfSpecMAX", "PAR_rTempOutdoorOutOfSpecMIN", "PAR_rTempWCSOfCon_HeaterOFF", "PAR_rTempWCSOfCon_HeaterON", "PAR_rTempWCSOfGen_HeaterOFF", "PAR_rTempWCSOfGen_HeaterON", "PAR_rTempWindsensors_HeaterON", "PAR_rTemp_CS_GBXLevel1OFF", "PAR_rTemp_CS_GBXLevel1ON", "PAR_rTemp_CS_GBXLevel2OFF", "PAR_rTemp_CS_GBXLevel2ON", "PAR_rTemp_CS_GBXLevel3OFF", "PAR_rTemp_CS_GBXLevel3ON", "PAR_rTemp_CS_GBXLevel4OFF", "PAR_rTemp_CS_GBXLevel4ON", "PAR_rTemp_CS_GBXOutletHigh", "PAR_rTemp_CS_GBXOutletHigh_Hysteresis", "PAR_rTemp_CS_GENLevel2OFF", "PAR_rTemp_CS_GENLevel2ON", "PAR_rTemp_CS_GENLevel3OFF", "PAR_rTemp_CS_GENLevel3ON", "PAR_rTemp_CS_GENLevel4OFF", "PAR_rTemp_CS_GENLevel4ON", "PAR_rTemp_CS_GENOutletHigh_Hysteresis", "PAR_rTimeForForceSelfTest", "PAR_rTimeForGBXPumpLSOFFInterval", "PAR_rTimeForGBXPumpLSONInterval", "PAR_rToleranceAngleForMotorStop", "PAR_rToleranceYawEncoderFault", "PAR_rTransformerPhaseTempDifferent", "PAR_rTransformerTempHigh", "PAR_rTransformerTempVeryHigh", "PAR_rValueBlockYawForVibration", "PAR_rWCSCVTFanOn", "PAR_rWCSCVTHeaterOn", "PAR_rWCSCVTHysteresis", "PAR_rWCSCVTInletPreHigh1", "PAR_rWCSCVTInletPreHigh2", "PAR_rWCSCVTInletPreLow1", "PAR_rWCSCVTInletPreLow2", "PAR_rWCSCVTInletTempHigh1", "PAR_rWCSCVTInletTempHigh2", "PAR_rWCSCVTInletTempLow", "PAR_rWCSCVTOutletPreLow1", "PAR_rWCSCVTOutletPreLow2", "PAR_rWCSCVTTripleValve", "PAR_rWCSGENFan1On", "PAR_rWCSGENFan2On", "PAR_rWCSGENFan3On", "PAR_rWCSGENHeaterOn", "PAR_rWCSGENHysteresisTripleValve", "PAR_rWCSGENInletPreHigh1", "PAR_rWCSGENInletPreHigh2", "PAR_rWCSGENInletPreLow1", "PAR_rWCSGENInletPreLow2", "PAR_rWCSGENInletTempHigh1", "PAR_rWCSGENInletTempLow", "PAR_rWCSGENOutletPreLow1", "PAR_rWCSGENOutletPreLow2", "PAR_rWCSGENOutletTempHigh", "PAR_rWCSGENTripleValve", "PAR_rWFMSActivePowerSetValueMIN", "PAR_rWFMSReactivePowerSetValueMAX", "PAR_rWFMSReactivePowerSetValueMIN", "PAR_rWeight_CS_PumpHigh", "PAR_rWeight_CS_PumpLow", "PAR_rWindDirectionMaxDiffValue", "PAR_rWindDirectionMaxDiffValue_WindIris", "PAR_rWindSpeed2CalibrationCoefficientA", "PAR_rWindSpeed2CalibrationCoefficientB", "PAR_rWindSpeed2CalibrationCoefficientC", "PAR_rWindSpeedAbovePitchMove", "PAR_rWindSpeedCalibrationCoefficientA", "PAR_rWindSpeedCalibrationCoefficientB", "PAR_rWindSpeedCalibrationCoefficientC", "PAR_rWindSpeedEnableMaxYawUntwist", "PAR_rWindSpeedMaxDiffValue", "PAR_rWindSpeedSelectDiffYawStrategy", "PAR_rWindSpeedSignalMax", "PAR_rWindSpeedSignalMin", "PAR_rWindYawTreckingFastReaction", "PAR_rYawEncoderBacklash", "PAR_rYawMaxDeviationAtAllWindspeeds", "PAR_rYawMotorHeatersDisabled", "PAR_rYawMotorHeatersEnabled", "PAR_rYawPositionSignalMax", "PAR_rYawPositionSignalMin", "PAR_rYawSensorOffsetAtCableTwistZero", "PAR_rYawSpeed_grdpermin", "PAR_rYawTurnsAtLimitSwitchLevel2", "PAR_tBasicDelayForRestart", "PAR_tBlockYawForVibration_ResetDelay", "PAR_tCANConverterAutoResetDelayTime", "PAR_tCANConverterTimeout", "PAR_tCANConverterTimeoutLevel1", "PAR_tCANConverterTimeoutLevel1Period", "PAR_tCANConverterTimeoutLevel2", "PAR_tCANConverterTimeoutLevel2Period", "PAR_tCS_JudgeInterval", "PAR_tCS_SampleInterval", "PAR_tCVT_MinInterval_TwiceCharge", "PAR_tConverter_DCLinkChargeAutoResetDelayTime", "PAR_tConverter_DCLinkChargeTimeOutPeriod", "PAR_tConverter_MasterSlaveConfigurationPeriod", "PAR_tCoreControllerComTimeout", "PAR_tCrossReferenceCheck_WindIris", "PAR_tCutOffDelayConverter", "PAR_tDelayCloseYawMotorBrake", "PAR_tDelayDrivetrainRecoveryTime", "PAR_tDelayEl6751ResetOpInPoweringUp", "PAR_tDelayForCheckValvePosition", "PAR_tDelayForPowerUpReboot", "PAR_tDelayOpenYawMotorBrakes", "PAR_tDelayPitchRecoveryTimeLevel1", "PAR_tDelayPitchRecoveryTimeLevel2", "PAR_tDelayToStartHydrBrake", "PAR_tDelayToStopHydrBrake", "PAR_tDetecTowerVibrationDelay", "PAR_tDrivetrainFaultRepeatPeriod", "PAR_tDurationCheckYawSpeed", "PAR_tDurationOfVibrationOffsetForLVRT", "PAR_tEthercatRepeatPeriod", "PAR_tGJSensorComTimeout", "PAR_tGearOilPressureLowSetDelay", "PAR_tGenSpeedDelayCompareRotGen", "PAR_tHVRTVolLevel0SetDelay", "PAR_tHVRTVolLevel1SetDelay", "PAR_tHVRTVolLevel2SetDelay", "PAR_tIntervalReadBySDOAfterFault", "PAR_tIntervalReadTempBySDO", "PAR_tIntervalRebootPitchSystem", "PAR_tIntervalWindIrisAutoSwitch", "PAR_tIntervalWritePersData", "PAR_tLVRTSimDuration", "PAR_tMainBearingLubFaultDetTime", "PAR_tMainBearingLubOnTime", "PAR_tMainBearingLubPauseTime", "PAR_tMaxTimeAtRideThroughMode", "PAR_tMaxTimeReadBySDOAfterFault", "PAR_tPitchComTimeout", "PAR_tPitchFaultRepeatPeriodeLevel1", "PAR_tPitchFaultRepeatPeriodeLevel2", "PAR_tPowerupdelay", "PAR_tProfibusWCSCTimeout", "PAR_tProfibusWCSGTimeout", "PAR_tPulseTimeBypassFeatherLimitSwitch", "PAR_tSetdelayForDevicesLost", "PAR_tSetdelayForRecoveryEthercat", "PAR_tSwitchgear_Max_Time_For_Opening_Coil", "PAR_tSwitchgear_Time_For_Closing_Coil", "PAR_tT1GenSpeedPT2Filter", "PAR_tT1InputHighSpeedPT2Filter", "PAR_tT1InputLowSpeedPT2Filter", "PAR_tT2GenSpeedPT2Filter", "PAR_tT2InputHighSpeedPT2Filter", "PAR_tT2InputLowSpeedPT2Filter", "PAR_tTCS_JudgeInterval", "PAR_tTCS_PID_CtrlCycleTime", "PAR_tTCS_PID_Para_D_1", "PAR_tTCS_PID_Para_D_2", "PAR_tTCS_PID_Para_D_3", "PAR_tTCS_PID_Para_D_Damp", "PAR_tTCS_PID_Para_I_1", "PAR_tTCS_PID_Para_I_2", "PAR_tTCS_PID_Para_I_3", "PAR_tTCS_PumpOffSetDelay", "PAR_tTCS_SampleInterval", "PAR_tTimeOfEl6751ResetDelay", "PAR_tTimeOfEl6751ResetOp", "PAR_tTimeOutPLCWatchdog", "PAR_tWindfarmCOMTimeout", "PAR_tYawDelayRestartMotors", "PAR_tYawDelayStartMotors", "PAR_tfbPT2YawPositionT1", "PAR_tfbPT2YawPositionT2", "PAR_udGBXOilParticlePerDayAlarm", "PAR_udGBXOilParticlePerDayWarning", "PAR_udGBXOilParticleTotalAlarm", "PAR_udGBXOilParticleTotalWarning", "PAR_uiTeethOfYawBearing", "PAR_uiTeethOfYawEncoder", "PAR_uiYBox_MultiturnResolution", "PAR_uiYBox_SingleturnResolution" ] }