operation_modes.json 1.8 KB

12345678910111213141516171819202122232425262728293031323334353637383940414243444546
  1. {
  2. "meta": {
  3. "source": "Turbine State Machine ID.xlsx + T040116 V2.0",
  4. "provenance": {
  5. "kind": "OEM 调试包解析产物 (生成器/模板层), **非整机回读**",
  6. "evidence_grade": "**模板值** — 按三级标签(实机回读/模板值·生效/模板值·空置), 本包**无一条够得上'实机回读'**",
  7. "not": "不是任何一台机的实际设定; '一致/闭环/自洽'指模板与模板 或 模板与实测数据 之间的一致, **不代表某台机的实际值**",
  8. "usage": "证据强度=模板值 × 用途: 作**分组依据/设计意图**合格; 作**阈值锚不合格**",
  9. "see": "README '证据规矩' 节 + param_dict.json meta.SELF_CORRECTION_2026_09_02",
  10. "stamped": "2026-09-02 结构污染审计补标"
  11. }
  12. },
  13. "modes": {
  14. "0": "CON_iBrakeMode0",
  15. "1": "CON_iBrakeMode210",
  16. "2": "CON_iBrakeMode200",
  17. "3": "CON_iBrakeMode198",
  18. "4": "CON_iBrakeMode100",
  19. "5": "CON_iBrakeMode51",
  20. "6": "CON_iBrakeMode50",
  21. "7": "CON_iStandby",
  22. "8": "CON_iService_ManualCtrl",
  23. "9": "CON_iSelftest1",
  24. "10": "CON_iSelftest2",
  25. "11": "CON_iSelftest3",
  26. "12": "CON_iSelftest4",
  27. "13": "CON_iStartMode",
  28. "14": "CON_iDFIG_GutIn",
  29. "15": "CON_iDFIG_GridOp",
  30. "16": "CON_iDFIG_LVRT",
  31. "18": "CON_iDFIG_PitchMove",
  32. "19": "CON_iCAGE_GutIn",
  33. "20": "CON_iCAGE_GridOp",
  34. "21": "CON_iCAGE_LVRT",
  35. "23": "CON_iCAGE_PitchMove",
  36. "24": "CON_iSwitchToCAGE",
  37. "25": "CON_iSwitchToDFIG",
  38. "26": "CON_iSelftest5"
  39. },
  40. "notes": {
  41. "selftest_identity": "Selftest1-4 = 刹车/叶片/PCH/零位 (T040116); Selftest5 后加",
  42. "dfig_dormant": "小批量实机=鼠笼4.2MW全功率 (T040106), DFIG系为软件预留未用",
  43. "pitchmove": "并网中周期1分钟变桨活动位, 完成回GridOp",
  44. "startup_seq_observed": "13→19→20 (录波多段)"
  45. }
  46. }