| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629630631632633634635636637638639640641642643644645646647648649650651652653654655656657658659660661662663664665666667668669670671672673674675676677678679680681682683684685686687688689690691692693694695696697698699700701702703704705706707708709710711712713714715716717718719720721722723724725726727728729730731732733734735736737738739740741742743744745746747748749750751752753754755756757758759760761762763764765766767768769770771772773774775776777778779780781782783784785786787788789790791792793794795796797798799800801802803804805806807808809810811812813814815816817818819820821822823824825826827828829830831832833834835836837838839840841842843844845846847848849850851852853854855856857858859860861862863864865866867868869870871872873874875876877878879880881882883884885886887888889890891892893894895896897898899900901902903904905906907908909910911912913914915916917918919920921922923924925926927928929930931932933934935936937938939940941942943944945946947948949950951952953954955956957958959960961962963964965966967968969970971972973974975976977978979980981982983984985986987988989990991992993994995996997998999100010011002100310041005100610071008100910101011101210131014101510161017101810191020102110221023102410251026102710281029103010311032103310341035103610371038103910401041104210431044104510461047104810491050105110521053105410551056105710581059106010611062106310641065106610671068106910701071107210731074107510761077107810791080108110821083108410851086108710881089109010911092109310941095109610971098109911001101110211031104110511061107110811091110111111121113111411151116111711181119112011211122112311241125112611271128112911301131113211331134113511361137113811391140114111421143114411451146114711481149115011511152115311541155115611571158115911601161116211631164116511661167116811691170117111721173117411751176117711781179118011811182118311841185118611871188118911901191119211931194119511961197119811991200120112021203120412051206120712081209121012111212121312141215121612171218121912201221122212231224122512261227122812291230123112321233123412351236123712381239124012411242124312441245124612471248124912501251125212531254125512561257125812591260126112621263126412651266126712681269127012711272127312741275127612771278127912801281128212831284128512861287128812891290129112921293129412951296129712981299130013011302130313041305130613071308130913101311131213131314131513161317131813191320132113221323132413251326132713281329133013311332133313341335133613371338133913401341134213431344134513461347134813491350135113521353135413551356135713581359136013611362136313641365136613671368136913701371137213731374137513761377137813791380138113821383138413851386138713881389139013911392139313941395139613971398139914001401140214031404140514061407140814091410141114121413141414151416141714181419142014211422142314241425142614271428142914301431143214331434143514361437143814391440144114421443144414451446144714481449145014511452145314541455145614571458145914601461146214631464146514661467146814691470147114721473147414751476147714781479148014811482148314841485148614871488148914901491149214931494149514961497149814991500150115021503150415051506150715081509151015111512151315141515151615171518151915201521152215231524152515261527152815291530153115321533153415351536153715381539154015411542154315441545154615471548154915501551155215531554155515561557155815591560156115621563156415651566156715681569157015711572157315741575157615771578157915801581158215831584158515861587158815891590159115921593159415951596159715981599160016011602160316041605160616071608160916101611161216131614161516161617161816191620162116221623162416251626162716281629163016311632163316341635163616371638163916401641164216431644164516461647164816491650165116521653165416551656165716581659166016611662166316641665166616671668166916701671167216731674167516761677167816791680168116821683168416851686168716881689169016911692169316941695169616971698169917001701170217031704170517061707170817091710171117121713171417151716171717181719172017211722172317241725172617271728172917301731173217331734173517361737173817391740174117421743174417451746174717481749175017511752175317541755175617571758175917601761176217631764176517661767176817691770177117721773177417751776177717781779178017811782178317841785178617871788178917901791179217931794179517961797179817991800180118021803180418051806180718081809181018111812181318141815181618171818181918201821182218231824182518261827182818291830183118321833183418351836183718381839184018411842184318441845184618471848184918501851185218531854185518561857185818591860186118621863186418651866186718681869187018711872187318741875187618771878187918801881188218831884188518861887188818891890189118921893189418951896189718981899190019011902190319041905190619071908190919101911191219131914191519161917191819191920192119221923192419251926192719281929193019311932193319341935193619371938193919401941194219431944194519461947194819491950195119521953195419551956195719581959196019611962196319641965196619671968196919701971197219731974197519761977197819791980198119821983198419851986198719881989199019911992199319941995199619971998199920002001200220032004200520062007200820092010201120122013201420152016201720182019202020212022202320242025202620272028202920302031203220332034203520362037203820392040204120422043204420452046204720482049205020512052205320542055205620572058205920602061206220632064206520662067206820692070207120722073207420752076207720782079208020812082208320842085208620872088208920902091209220932094209520962097209820992100210121022103210421052106210721082109211021112112211321142115211621172118211921202121212221232124212521262127212821292130213121322133213421352136213721382139214021412142214321442145214621472148214921502151215221532154215521562157215821592160216121622163216421652166216721682169217021712172217321742175217621772178217921802181218221832184218521862187218821892190219121922193219421952196219721982199220022012202220322042205220622072208220922102211221222132214221522162217221822192220222122222223222422252226222722282229223022312232223322342235223622372238223922402241224222432244224522462247224822492250225122522253225422552256225722582259226022612262226322642265226622672268226922702271227222732274227522762277227822792280228122822283228422852286228722882289229022912292229322942295229622972298229923002301230223032304230523062307230823092310231123122313231423152316231723182319232023212322232323242325232623272328232923302331233223332334233523362337233823392340234123422343234423452346234723482349235023512352235323542355235623572358235923602361236223632364236523662367236823692370237123722373237423752376237723782379238023812382238323842385238623872388238923902391239223932394239523962397239823992400240124022403240424052406240724082409241024112412241324142415241624172418241924202421242224232424242524262427242824292430243124322433243424352436243724382439244024412442244324442445244624472448244924502451245224532454245524562457245824592460246124622463246424652466246724682469247024712472247324742475247624772478247924802481248224832484248524862487248824892490249124922493249424952496249724982499250025012502250325042505250625072508250925102511251225132514251525162517251825192520252125222523252425252526252725282529253025312532253325342535253625372538253925402541254225432544254525462547254825492550255125522553255425552556255725582559256025612562256325642565256625672568256925702571257225732574257525762577257825792580258125822583258425852586258725882589259025912592259325942595259625972598259926002601260226032604260526062607260826092610261126122613261426152616261726182619262026212622262326242625262626272628262926302631263226332634263526362637263826392640264126422643264426452646264726482649265026512652265326542655265626572658265926602661266226632664266526662667266826692670267126722673267426752676267726782679268026812682268326842685268626872688268926902691269226932694269526962697269826992700270127022703270427052706270727082709271027112712271327142715271627172718271927202721272227232724272527262727272827292730273127322733273427352736273727382739274027412742274327442745274627472748274927502751275227532754275527562757275827592760276127622763276427652766276727682769277027712772277327742775277627772778277927802781278227832784278527862787278827892790279127922793279427952796279727982799280028012802280328042805280628072808280928102811281228132814281528162817281828192820282128222823282428252826282728282829283028312832283328342835283628372838283928402841284228432844284528462847284828492850285128522853285428552856285728582859286028612862286328642865286628672868286928702871287228732874287528762877287828792880288128822883288428852886288728882889289028912892289328942895289628972898289929002901290229032904290529062907290829092910291129122913291429152916291729182919292029212922292329242925292629272928292929302931293229332934293529362937293829392940294129422943294429452946294729482949295029512952295329542955295629572958295929602961296229632964296529662967296829692970297129722973297429752976297729782979298029812982298329842985298629872988298929902991299229932994299529962997299829993000300130023003300430053006300730083009301030113012301330143015301630173018301930203021302230233024302530263027302830293030303130323033303430353036303730383039304030413042304330443045304630473048304930503051305230533054305530563057305830593060306130623063306430653066306730683069307030713072307330743075307630773078307930803081308230833084308530863087308830893090309130923093309430953096309730983099310031013102310331043105310631073108310931103111311231133114311531163117311831193120312131223123312431253126312731283129313031313132313331343135313631373138313931403141314231433144314531463147314831493150315131523153315431553156315731583159316031613162316331643165316631673168316931703171317231733174317531763177317831793180318131823183318431853186318731883189319031913192319331943195319631973198319932003201320232033204320532063207320832093210321132123213321432153216321732183219322032213222322332243225322632273228322932303231323232333234323532363237323832393240324132423243324432453246324732483249325032513252325332543255325632573258325932603261326232633264326532663267326832693270327132723273327432753276327732783279328032813282328332843285328632873288328932903291329232933294329532963297329832993300330133023303330433053306330733083309331033113312331333143315331633173318331933203321332233233324332533263327332833293330333133323333333433353336333733383339334033413342334333443345334633473348334933503351335233533354335533563357335833593360336133623363336433653366336733683369337033713372337333743375337633773378337933803381338233833384338533863387338833893390339133923393339433953396339733983399340034013402340334043405340634073408340934103411341234133414341534163417341834193420342134223423342434253426342734283429343034313432343334343435343634373438343934403441344234433444344534463447344834493450345134523453345434553456345734583459346034613462346334643465346634673468346934703471347234733474347534763477347834793480348134823483348434853486348734883489349034913492349334943495349634973498349935003501350235033504350535063507350835093510351135123513351435153516351735183519352035213522352335243525352635273528352935303531353235333534353535363537353835393540354135423543354435453546354735483549355035513552355335543555355635573558355935603561356235633564356535663567356835693570357135723573357435753576357735783579358035813582358335843585358635873588358935903591359235933594359535963597359835993600360136023603360436053606360736083609361036113612361336143615361636173618361936203621362236233624362536263627362836293630363136323633363436353636363736383639364036413642364336443645364636473648364936503651365236533654365536563657365836593660366136623663366436653666366736683669367036713672367336743675367636773678367936803681368236833684368536863687368836893690369136923693369436953696369736983699370037013702370337043705370637073708370937103711371237133714371537163717371837193720372137223723372437253726372737283729373037313732373337343735373637373738373937403741374237433744374537463747374837493750375137523753375437553756375737583759376037613762376337643765376637673768376937703771377237733774377537763777377837793780378137823783378437853786378737883789379037913792379337943795379637973798379938003801380238033804380538063807380838093810381138123813381438153816381738183819382038213822382338243825382638273828382938303831383238333834383538363837383838393840384138423843384438453846384738483849385038513852385338543855385638573858385938603861386238633864386538663867386838693870387138723873387438753876387738783879388038813882388338843885388638873888388938903891389238933894389538963897389838993900390139023903390439053906390739083909391039113912391339143915391639173918391939203921392239233924392539263927392839293930393139323933393439353936393739383939394039413942394339443945394639473948394939503951395239533954395539563957395839593960396139623963396439653966396739683969397039713972397339743975397639773978397939803981398239833984398539863987398839893990399139923993399439953996399739983999400040014002400340044005400640074008400940104011401240134014401540164017401840194020402140224023402440254026402740284029403040314032403340344035403640374038403940404041404240434044404540464047404840494050405140524053405440554056405740584059406040614062406340644065406640674068406940704071407240734074407540764077407840794080408140824083408440854086408740884089409040914092409340944095409640974098409941004101410241034104410541064107410841094110411141124113411441154116411741184119412041214122412341244125412641274128412941304131413241334134413541364137413841394140414141424143414441454146414741484149415041514152415341544155415641574158415941604161416241634164416541664167416841694170417141724173417441754176417741784179418041814182418341844185418641874188418941904191419241934194419541964197419841994200420142024203420442054206420742084209421042114212421342144215421642174218421942204221422242234224422542264227422842294230423142324233423442354236423742384239424042414242424342444245424642474248424942504251425242534254425542564257425842594260426142624263426442654266426742684269427042714272427342744275427642774278427942804281428242834284428542864287428842894290429142924293429442954296429742984299430043014302430343044305430643074308430943104311431243134314431543164317431843194320432143224323432443254326432743284329433043314332433343344335433643374338433943404341434243434344434543464347434843494350435143524353435443554356435743584359436043614362436343644365436643674368436943704371437243734374437543764377437843794380438143824383438443854386438743884389439043914392439343944395439643974398439944004401440244034404440544064407440844094410441144124413441444154416441744184419442044214422442344244425442644274428442944304431443244334434443544364437443844394440444144424443444444454446444744484449445044514452445344544455445644574458445944604461446244634464446544664467446844694470447144724473447444754476447744784479448044814482448344844485448644874488448944904491449244934494449544964497449844994500450145024503450445054506450745084509451045114512451345144515451645174518451945204521452245234524452545264527452845294530453145324533453445354536453745384539454045414542454345444545454645474548454945504551455245534554455545564557455845594560456145624563456445654566456745684569457045714572457345744575457645774578457945804581458245834584458545864587458845894590459145924593459445954596459745984599460046014602460346044605460646074608460946104611461246134614461546164617461846194620462146224623462446254626462746284629463046314632463346344635463646374638463946404641464246434644464546464647464846494650465146524653465446554656465746584659466046614662466346644665466646674668466946704671467246734674467546764677467846794680468146824683468446854686468746884689469046914692469346944695469646974698469947004701470247034704470547064707470847094710471147124713471447154716471747184719472047214722472347244725472647274728472947304731473247334734473547364737473847394740474147424743474447454746474747484749475047514752475347544755475647574758475947604761476247634764476547664767476847694770477147724773477447754776477747784779478047814782478347844785478647874788478947904791479247934794479547964797479847994800480148024803480448054806480748084809481048114812481348144815481648174818481948204821482248234824482548264827482848294830483148324833483448354836483748384839484048414842484348444845484648474848484948504851485248534854485548564857485848594860486148624863486448654866486748684869487048714872487348744875487648774878487948804881488248834884488548864887488848894890489148924893489448954896489748984899490049014902490349044905490649074908490949104911491249134914491549164917491849194920492149224923492449254926492749284929493049314932493349344935493649374938493949404941494249434944494549464947494849494950495149524953495449554956495749584959496049614962496349644965496649674968496949704971497249734974497549764977497849794980498149824983498449854986498749884989499049914992499349944995499649974998499950005001500250035004500550065007500850095010501150125013501450155016501750185019502050215022502350245025502650275028502950305031503250335034503550365037503850395040504150425043504450455046504750485049505050515052505350545055505650575058505950605061506250635064506550665067506850695070507150725073507450755076507750785079508050815082508350845085508650875088508950905091509250935094509550965097509850995100510151025103510451055106510751085109511051115112511351145115511651175118511951205121512251235124512551265127512851295130513151325133513451355136513751385139514051415142514351445145514651475148514951505151515251535154515551565157515851595160516151625163516451655166516751685169517051715172517351745175517651775178517951805181518251835184518551865187518851895190519151925193519451955196519751985199520052015202520352045205520652075208520952105211521252135214521552165217521852195220522152225223522452255226522752285229523052315232523352345235523652375238523952405241524252435244524552465247524852495250525152525253525452555256525752585259526052615262526352645265526652675268526952705271527252735274527552765277527852795280528152825283528452855286528752885289529052915292529352945295529652975298529953005301530253035304530553065307530853095310531153125313531453155316531753185319532053215322532353245325532653275328532953305331533253335334533553365337533853395340534153425343534453455346534753485349535053515352535353545355535653575358535953605361536253635364536553665367536853695370537153725373537453755376537753785379538053815382538353845385538653875388538953905391539253935394539553965397539853995400540154025403540454055406540754085409541054115412541354145415541654175418541954205421542254235424542554265427542854295430543154325433543454355436543754385439544054415442544354445445544654475448544954505451545254535454545554565457545854595460546154625463546454655466546754685469547054715472547354745475547654775478547954805481548254835484548554865487548854895490549154925493549454955496549754985499550055015502550355045505550655075508550955105511551255135514551555165517551855195520552155225523552455255526552755285529553055315532553355345535553655375538553955405541554255435544554555465547554855495550555155525553555455555556555755585559556055615562556355645565556655675568556955705571557255735574557555765577557855795580558155825583558455855586558755885589559055915592559355945595559655975598559956005601560256035604560556065607560856095610561156125613561456155616561756185619562056215622562356245625562656275628562956305631563256335634563556365637563856395640564156425643564456455646564756485649565056515652565356545655565656575658565956605661566256635664566556665667566856695670567156725673567456755676567756785679568056815682568356845685568656875688568956905691569256935694569556965697569856995700570157025703570457055706570757085709571057115712571357145715571657175718571957205721572257235724572557265727572857295730573157325733573457355736573757385739574057415742574357445745574657475748574957505751575257535754575557565757575857595760576157625763576457655766576757685769577057715772577357745775577657775778577957805781578257835784578557865787578857895790579157925793579457955796579757985799580058015802580358045805580658075808580958105811581258135814581558165817581858195820582158225823582458255826582758285829583058315832583358345835583658375838583958405841584258435844584558465847584858495850585158525853585458555856585758585859586058615862586358645865586658675868586958705871587258735874587558765877587858795880588158825883588458855886588758885889589058915892589358945895589658975898589959005901590259035904590559065907590859095910591159125913591459155916591759185919592059215922592359245925592659275928592959305931593259335934593559365937593859395940594159425943594459455946594759485949595059515952595359545955595659575958595959605961596259635964596559665967596859695970597159725973597459755976597759785979598059815982598359845985598659875988598959905991599259935994599559965997599859996000600160026003600460056006600760086009601060116012601360146015601660176018601960206021602260236024602560266027602860296030603160326033603460356036603760386039604060416042604360446045604660476048604960506051605260536054605560566057605860596060606160626063606460656066606760686069607060716072607360746075607660776078607960806081608260836084608560866087608860896090609160926093609460956096609760986099610061016102610361046105610661076108610961106111611261136114611561166117611861196120612161226123612461256126612761286129613061316132613361346135613661376138613961406141614261436144614561466147614861496150615161526153615461556156615761586159616061616162616361646165616661676168616961706171617261736174617561766177617861796180618161826183618461856186618761886189619061916192619361946195619661976198619962006201620262036204620562066207620862096210621162126213621462156216621762186219622062216222622362246225622662276228622962306231623262336234623562366237623862396240624162426243624462456246624762486249625062516252625362546255625662576258625962606261626262636264626562666267626862696270627162726273627462756276627762786279628062816282628362846285628662876288628962906291629262936294629562966297629862996300630163026303630463056306630763086309631063116312631363146315631663176318631963206321632263236324632563266327632863296330633163326333633463356336633763386339634063416342634363446345634663476348634963506351635263536354635563566357635863596360636163626363636463656366636763686369637063716372637363746375637663776378637963806381638263836384638563866387638863896390639163926393639463956396639763986399640064016402640364046405640664076408640964106411641264136414641564166417641864196420642164226423642464256426642764286429643064316432643364346435643664376438643964406441644264436444644564466447644864496450645164526453645464556456645764586459646064616462646364646465646664676468646964706471647264736474647564766477647864796480648164826483648464856486648764886489649064916492649364946495649664976498649965006501650265036504650565066507650865096510651165126513651465156516651765186519652065216522652365246525652665276528652965306531653265336534653565366537653865396540654165426543654465456546654765486549655065516552655365546555655665576558655965606561656265636564656565666567656865696570657165726573657465756576657765786579658065816582658365846585658665876588658965906591659265936594659565966597659865996600660166026603660466056606660766086609661066116612661366146615661666176618661966206621662266236624662566266627662866296630663166326633663466356636663766386639664066416642664366446645664666476648664966506651665266536654665566566657665866596660666166626663666466656666666766686669667066716672667366746675667666776678667966806681668266836684668566866687668866896690669166926693669466956696669766986699670067016702670367046705670667076708670967106711671267136714671567166717671867196720672167226723672467256726672767286729673067316732673367346735673667376738673967406741674267436744674567466747674867496750675167526753675467556756675767586759676067616762676367646765676667676768676967706771677267736774677567766777677867796780678167826783678467856786678767886789679067916792679367946795679667976798679968006801680268036804680568066807680868096810681168126813681468156816681768186819682068216822682368246825682668276828682968306831683268336834683568366837683868396840684168426843684468456846684768486849685068516852685368546855685668576858685968606861686268636864686568666867686868696870687168726873687468756876687768786879688068816882688368846885688668876888688968906891689268936894689568966897689868996900690169026903690469056906690769086909691069116912691369146915691669176918691969206921692269236924692569266927692869296930693169326933693469356936693769386939694069416942694369446945694669476948694969506951695269536954695569566957695869596960696169626963696469656966696769686969697069716972697369746975697669776978697969806981698269836984698569866987698869896990699169926993699469956996699769986999700070017002700370047005700670077008700970107011701270137014701570167017701870197020702170227023702470257026702770287029703070317032703370347035703670377038703970407041704270437044704570467047704870497050705170527053705470557056705770587059706070617062706370647065706670677068706970707071707270737074707570767077707870797080708170827083708470857086708770887089709070917092709370947095709670977098709971007101710271037104710571067107710871097110711171127113711471157116711771187119712071217122712371247125712671277128712971307131713271337134713571367137713871397140714171427143714471457146714771487149715071517152715371547155715671577158715971607161716271637164716571667167716871697170717171727173717471757176717771787179718071817182718371847185718671877188718971907191719271937194719571967197719871997200720172027203720472057206720772087209721072117212721372147215721672177218721972207221722272237224722572267227722872297230723172327233723472357236723772387239724072417242724372447245724672477248724972507251725272537254725572567257725872597260726172627263726472657266726772687269727072717272727372747275727672777278727972807281728272837284728572867287728872897290729172927293729472957296729772987299730073017302730373047305730673077308730973107311731273137314731573167317731873197320732173227323732473257326732773287329733073317332733373347335733673377338733973407341734273437344734573467347734873497350735173527353735473557356735773587359736073617362736373647365736673677368736973707371737273737374737573767377737873797380738173827383738473857386738773887389739073917392739373947395739673977398739974007401740274037404740574067407740874097410741174127413741474157416741774187419742074217422742374247425742674277428742974307431743274337434743574367437743874397440744174427443744474457446744774487449745074517452745374547455745674577458745974607461746274637464746574667467746874697470747174727473747474757476747774787479748074817482748374847485748674877488748974907491749274937494749574967497749874997500750175027503750475057506750775087509751075117512751375147515751675177518751975207521752275237524752575267527752875297530753175327533753475357536753775387539754075417542754375447545754675477548754975507551755275537554755575567557755875597560756175627563756475657566756775687569757075717572757375747575757675777578757975807581758275837584758575867587758875897590759175927593759475957596759775987599760076017602760376047605760676077608760976107611761276137614761576167617761876197620762176227623762476257626762776287629763076317632763376347635763676377638763976407641764276437644764576467647764876497650765176527653765476557656765776587659766076617662766376647665766676677668766976707671767276737674767576767677767876797680768176827683768476857686768776887689769076917692769376947695769676977698769977007701770277037704770577067707770877097710771177127713771477157716771777187719772077217722772377247725772677277728772977307731773277337734773577367737773877397740774177427743774477457746774777487749775077517752775377547755775677577758775977607761776277637764776577667767776877697770777177727773777477757776777777787779778077817782778377847785778677877788778977907791779277937794779577967797779877997800780178027803780478057806780778087809781078117812781378147815781678177818781978207821782278237824782578267827782878297830783178327833783478357836783778387839784078417842784378447845784678477848784978507851785278537854785578567857785878597860786178627863786478657866786778687869787078717872787378747875787678777878787978807881788278837884788578867887788878897890789178927893789478957896789778987899790079017902790379047905790679077908790979107911791279137914791579167917791879197920792179227923792479257926792779287929793079317932793379347935793679377938793979407941794279437944794579467947794879497950795179527953795479557956795779587959796079617962796379647965796679677968796979707971797279737974797579767977797879797980798179827983798479857986798779887989799079917992799379947995799679977998799980008001800280038004800580068007800880098010801180128013801480158016801780188019802080218022802380248025802680278028802980308031803280338034803580368037803880398040804180428043804480458046804780488049805080518052805380548055805680578058805980608061806280638064806580668067806880698070807180728073807480758076807780788079808080818082808380848085808680878088808980908091809280938094809580968097809880998100810181028103810481058106810781088109811081118112811381148115811681178118811981208121812281238124812581268127812881298130813181328133813481358136813781388139814081418142814381448145814681478148814981508151815281538154815581568157815881598160816181628163816481658166816781688169817081718172817381748175817681778178817981808181818281838184818581868187818881898190819181928193819481958196819781988199820082018202820382048205820682078208820982108211821282138214821582168217821882198220822182228223822482258226822782288229823082318232823382348235823682378238823982408241824282438244824582468247824882498250825182528253825482558256825782588259826082618262826382648265826682678268826982708271827282738274827582768277827882798280828182828283828482858286828782888289829082918292829382948295829682978298829983008301830283038304830583068307830883098310831183128313831483158316831783188319832083218322832383248325832683278328832983308331833283338334833583368337833883398340834183428343834483458346834783488349835083518352835383548355835683578358835983608361836283638364836583668367836883698370837183728373837483758376837783788379838083818382838383848385838683878388838983908391839283938394839583968397839883998400840184028403840484058406840784088409841084118412841384148415841684178418841984208421842284238424842584268427842884298430843184328433843484358436843784388439844084418442844384448445844684478448844984508451845284538454845584568457845884598460846184628463846484658466846784688469847084718472847384748475847684778478847984808481848284838484848584868487848884898490849184928493849484958496849784988499850085018502850385048505850685078508850985108511851285138514851585168517851885198520852185228523852485258526852785288529853085318532853385348535853685378538853985408541854285438544854585468547854885498550855185528553855485558556855785588559856085618562856385648565856685678568856985708571857285738574857585768577857885798580858185828583858485858586858785888589859085918592859385948595859685978598859986008601860286038604860586068607860886098610861186128613861486158616861786188619862086218622862386248625862686278628862986308631863286338634863586368637863886398640864186428643864486458646864786488649865086518652865386548655865686578658865986608661866286638664866586668667866886698670867186728673867486758676867786788679868086818682868386848685868686878688868986908691869286938694869586968697869886998700870187028703870487058706870787088709871087118712871387148715871687178718871987208721872287238724872587268727872887298730873187328733873487358736873787388739874087418742874387448745874687478748874987508751875287538754875587568757875887598760876187628763876487658766876787688769877087718772877387748775877687778778877987808781878287838784878587868787878887898790879187928793879487958796879787988799880088018802880388048805880688078808880988108811881288138814881588168817881888198820882188228823882488258826882788288829883088318832883388348835883688378838883988408841884288438844884588468847884888498850885188528853885488558856885788588859886088618862886388648865886688678868886988708871887288738874887588768877887888798880888188828883888488858886888788888889889088918892889388948895889688978898889989008901890289038904890589068907890889098910891189128913891489158916891789188919892089218922892389248925892689278928892989308931893289338934893589368937893889398940894189428943894489458946894789488949895089518952895389548955895689578958895989608961896289638964896589668967896889698970897189728973897489758976897789788979898089818982898389848985898689878988898989908991899289938994899589968997899889999000900190029003900490059006900790089009901090119012901390149015901690179018901990209021902290239024902590269027902890299030903190329033903490359036903790389039904090419042904390449045904690479048904990509051905290539054905590569057905890599060906190629063906490659066906790689069907090719072907390749075907690779078907990809081908290839084908590869087908890899090909190929093909490959096909790989099910091019102910391049105910691079108910991109111911291139114911591169117911891199120912191229123912491259126912791289129913091319132913391349135913691379138913991409141914291439144914591469147914891499150915191529153915491559156915791589159916091619162916391649165916691679168916991709171917291739174917591769177917891799180918191829183918491859186918791889189919091919192919391949195919691979198919992009201920292039204920592069207920892099210921192129213921492159216921792189219922092219222922392249225922692279228922992309231923292339234923592369237923892399240924192429243924492459246924792489249925092519252925392549255925692579258925992609261926292639264926592669267926892699270927192729273927492759276927792789279928092819282928392849285928692879288928992909291929292939294929592969297929892999300930193029303930493059306930793089309931093119312931393149315931693179318931993209321932293239324932593269327932893299330933193329333933493359336933793389339934093419342934393449345934693479348934993509351935293539354935593569357935893599360936193629363936493659366936793689369937093719372937393749375937693779378937993809381938293839384938593869387938893899390939193929393939493959396939793989399940094019402940394049405940694079408940994109411941294139414941594169417941894199420942194229423942494259426942794289429943094319432943394349435943694379438943994409441944294439444944594469447944894499450945194529453945494559456945794589459946094619462946394649465946694679468946994709471947294739474947594769477947894799480948194829483948494859486948794889489949094919492949394949495949694979498949995009501950295039504950595069507950895099510951195129513951495159516951795189519952095219522952395249525952695279528952995309531953295339534953595369537953895399540954195429543954495459546954795489549955095519552955395549555955695579558955995609561956295639564956595669567956895699570957195729573957495759576957795789579958095819582958395849585958695879588958995909591959295939594959595969597959895999600960196029603960496059606960796089609961096119612961396149615961696179618961996209621962296239624962596269627962896299630963196329633963496359636963796389639964096419642964396449645964696479648964996509651965296539654965596569657965896599660966196629663966496659666966796689669967096719672967396749675967696779678967996809681968296839684968596869687968896899690969196929693969496959696969796989699970097019702970397049705970697079708970997109711971297139714971597169717971897199720972197229723972497259726972797289729973097319732973397349735973697379738973997409741974297439744974597469747974897499750975197529753975497559756975797589759976097619762976397649765976697679768976997709771977297739774977597769777977897799780978197829783978497859786978797889789979097919792979397949795979697979798979998009801980298039804980598069807980898099810981198129813981498159816981798189819982098219822982398249825982698279828982998309831983298339834983598369837983898399840984198429843984498459846984798489849985098519852985398549855985698579858985998609861986298639864986598669867986898699870987198729873987498759876987798789879988098819882988398849885988698879888988998909891989298939894989598969897989898999900990199029903990499059906990799089909991099119912991399149915991699179918991999209921992299239924992599269927992899299930993199329933993499359936993799389939994099419942994399449945994699479948994999509951995299539954995599569957995899599960996199629963996499659966996799689969997099719972997399749975997699779978997999809981998299839984998599869987998899899990999199929993999499959996999799989999100001000110002100031000410005100061000710008100091001010011100121001310014100151001610017100181001910020100211002210023100241002510026100271002810029100301003110032100331003410035100361003710038100391004010041100421004310044100451004610047100481004910050100511005210053100541005510056100571005810059100601006110062100631006410065100661006710068100691007010071100721007310074100751007610077100781007910080100811008210083100841008510086100871008810089100901009110092100931009410095100961009710098100991010010101101021010310104101051010610107101081010910110101111011210113101141011510116101171011810119101201012110122101231012410125101261012710128101291013010131101321013310134101351013610137101381013910140101411014210143101441014510146101471014810149101501015110152101531015410155101561015710158101591016010161101621016310164101651016610167101681016910170101711017210173101741017510176101771017810179101801018110182101831018410185101861018710188101891019010191101921019310194101951019610197101981019910200102011020210203102041020510206102071020810209102101021110212102131021410215102161021710218102191022010221102221022310224102251022610227102281022910230102311023210233102341023510236102371023810239102401024110242102431024410245102461024710248102491025010251102521025310254102551025610257102581025910260102611026210263102641026510266102671026810269102701027110272102731027410275102761027710278102791028010281102821028310284102851028610287102881028910290102911029210293102941029510296102971029810299103001030110302103031030410305103061030710308103091031010311103121031310314103151031610317103181031910320103211032210323103241032510326103271032810329103301033110332103331033410335103361033710338103391034010341103421034310344103451034610347103481034910350103511035210353103541035510356103571035810359103601036110362103631036410365103661036710368103691037010371103721037310374103751037610377103781037910380103811038210383103841038510386103871038810389103901039110392103931039410395103961039710398103991040010401104021040310404104051040610407104081040910410104111041210413104141041510416104171041810419104201042110422104231042410425104261042710428104291043010431104321043310434104351043610437104381043910440104411044210443104441044510446104471044810449104501045110452104531045410455104561045710458104591046010461104621046310464104651046610467104681046910470104711047210473104741047510476104771047810479104801048110482104831048410485104861048710488104891049010491104921049310494104951049610497104981049910500105011050210503105041050510506105071050810509105101051110512105131051410515105161051710518105191052010521105221052310524105251052610527105281052910530105311053210533105341053510536105371053810539105401054110542105431054410545105461054710548105491055010551105521055310554105551055610557105581055910560105611056210563105641056510566105671056810569105701057110572105731057410575105761057710578105791058010581105821058310584105851058610587105881058910590105911059210593105941059510596105971059810599106001060110602106031060410605106061060710608106091061010611106121061310614106151061610617106181061910620106211062210623106241062510626106271062810629106301063110632106331063410635106361063710638106391064010641106421064310644106451064610647106481064910650106511065210653106541065510656106571065810659106601066110662106631066410665106661066710668106691067010671106721067310674106751067610677106781067910680106811068210683106841068510686106871068810689106901069110692106931069410695106961069710698106991070010701107021070310704107051070610707107081070910710107111071210713107141071510716107171071810719107201072110722107231072410725107261072710728107291073010731107321073310734107351073610737107381073910740107411074210743107441074510746107471074810749107501075110752107531075410755107561075710758107591076010761107621076310764107651076610767107681076910770107711077210773107741077510776107771077810779107801078110782107831078410785107861078710788107891079010791107921079310794107951079610797107981079910800108011080210803108041080510806108071080810809108101081110812108131081410815108161081710818108191082010821108221082310824108251082610827108281082910830108311083210833108341083510836108371083810839108401084110842108431084410845108461084710848108491085010851108521085310854108551085610857108581085910860108611086210863108641086510866108671086810869108701087110872108731087410875108761087710878108791088010881108821088310884108851088610887108881088910890108911089210893108941089510896108971089810899109001090110902109031090410905109061090710908109091091010911109121091310914109151091610917109181091910920109211092210923109241092510926109271092810929109301093110932109331093410935109361093710938109391094010941109421094310944109451094610947109481094910950109511095210953109541095510956109571095810959109601096110962109631096410965109661096710968109691097010971109721097310974109751097610977109781097910980109811098210983109841098510986109871098810989109901099110992109931099410995109961099710998109991100011001110021100311004110051100611007110081100911010110111101211013110141101511016110171101811019110201102111022110231102411025110261102711028110291103011031110321103311034110351103611037110381103911040110411104211043110441104511046110471104811049110501105111052110531105411055110561105711058110591106011061110621106311064110651106611067110681106911070110711107211073110741107511076110771107811079110801108111082110831108411085110861108711088110891109011091110921109311094110951109611097110981109911100111011110211103111041110511106111071110811109111101111111112111131111411115111161111711118111191112011121111221112311124111251112611127111281112911130111311113211133111341113511136111371113811139111401114111142111431114411145111461114711148111491115011151111521115311154111551115611157111581115911160111611116211163111641116511166111671116811169111701117111172111731117411175111761117711178111791118011181111821118311184111851118611187111881118911190111911119211193111941119511196111971119811199112001120111202112031120411205112061120711208112091121011211112121121311214112151121611217112181121911220112211122211223112241122511226112271122811229112301123111232112331123411235112361123711238112391124011241112421124311244112451124611247112481124911250112511125211253112541125511256112571125811259112601126111262112631126411265112661126711268112691127011271112721127311274112751127611277112781127911280112811128211283112841128511286112871128811289112901129111292112931129411295112961129711298112991130011301113021130311304113051130611307113081130911310113111131211313113141131511316113171131811319113201132111322113231132411325113261132711328113291133011331113321133311334113351133611337113381133911340113411134211343113441134511346113471134811349113501135111352113531135411355113561135711358113591136011361113621136311364113651136611367113681136911370113711137211373113741137511376113771137811379113801138111382113831138411385113861138711388113891139011391113921139311394113951139611397113981139911400114011140211403114041140511406114071140811409114101141111412114131141411415114161141711418114191142011421114221142311424114251142611427114281142911430114311143211433114341143511436114371143811439114401144111442114431144411445114461144711448114491145011451114521145311454114551145611457114581145911460114611146211463114641146511466114671146811469114701147111472114731147411475114761147711478114791148011481114821148311484114851148611487114881148911490114911149211493114941149511496114971149811499115001150111502115031150411505115061150711508115091151011511115121151311514115151151611517115181151911520115211152211523115241152511526115271152811529115301153111532115331153411535115361153711538115391154011541115421154311544115451154611547115481154911550115511155211553115541155511556115571155811559115601156111562115631156411565115661156711568115691157011571115721157311574115751157611577115781157911580115811158211583115841158511586115871158811589115901159111592115931159411595115961159711598115991160011601116021160311604116051160611607116081160911610116111161211613116141161511616116171161811619116201162111622116231162411625116261162711628116291163011631116321163311634116351163611637116381163911640116411164211643116441164511646116471164811649116501165111652116531165411655116561165711658116591166011661116621166311664116651166611667116681166911670116711167211673116741167511676116771167811679116801168111682116831168411685116861168711688116891169011691116921169311694116951169611697116981169911700117011170211703117041170511706117071170811709117101171111712117131171411715117161171711718117191172011721117221172311724117251172611727117281172911730117311173211733117341173511736117371173811739117401174111742117431174411745117461174711748117491175011751117521175311754117551175611757117581175911760117611176211763117641176511766117671176811769117701177111772117731177411775117761177711778117791178011781117821178311784117851178611787117881178911790117911179211793117941179511796117971179811799118001180111802118031180411805118061180711808118091181011811118121181311814118151181611817118181181911820118211182211823118241182511826118271182811829118301183111832118331183411835118361183711838118391184011841118421184311844118451184611847118481184911850118511185211853118541185511856118571185811859118601186111862118631186411865118661186711868118691187011871118721187311874118751187611877118781187911880118811188211883118841188511886118871188811889118901189111892118931189411895118961189711898118991190011901119021190311904119051190611907119081190911910119111191211913119141191511916119171191811919119201192111922119231192411925119261192711928119291193011931119321193311934119351193611937119381193911940119411194211943119441194511946119471194811949119501195111952119531195411955119561195711958119591196011961119621196311964119651196611967119681196911970119711197211973119741197511976119771197811979119801198111982119831198411985119861198711988119891199011991119921199311994119951199611997119981199912000120011200212003120041200512006120071200812009120101201112012120131201412015120161201712018120191202012021120221202312024120251202612027120281202912030120311203212033120341203512036120371203812039120401204112042120431204412045120461204712048120491205012051120521205312054120551205612057120581205912060120611206212063120641206512066120671206812069120701207112072120731207412075120761207712078120791208012081120821208312084120851208612087120881208912090120911209212093120941209512096120971209812099121001210112102121031210412105121061210712108121091211012111121121211312114121151211612117121181211912120121211212212123121241212512126121271212812129121301213112132121331213412135121361213712138121391214012141121421214312144121451214612147121481214912150121511215212153121541215512156121571215812159121601216112162121631216412165121661216712168121691217012171121721217312174121751217612177121781217912180121811218212183121841218512186121871218812189121901219112192121931219412195121961219712198121991220012201122021220312204122051220612207122081220912210122111221212213122141221512216122171221812219122201222112222122231222412225122261222712228122291223012231122321223312234122351223612237122381223912240122411224212243122441224512246122471224812249122501225112252122531225412255122561225712258122591226012261122621226312264122651226612267122681226912270122711227212273122741227512276122771227812279122801228112282122831228412285122861228712288122891229012291122921229312294122951229612297122981229912300123011230212303123041230512306123071230812309123101231112312123131231412315123161231712318123191232012321123221232312324123251232612327123281232912330123311233212333123341233512336123371233812339123401234112342123431234412345123461234712348123491235012351123521235312354123551235612357123581235912360123611236212363123641236512366123671236812369123701237112372123731237412375123761237712378123791238012381123821238312384123851238612387123881238912390123911239212393123941239512396123971239812399124001240112402124031240412405124061240712408124091241012411124121241312414124151241612417124181241912420124211242212423124241242512426124271242812429124301243112432124331243412435124361243712438124391244012441124421244312444124451244612447124481244912450124511245212453124541245512456124571245812459124601246112462124631246412465124661246712468124691247012471124721247312474124751247612477124781247912480124811248212483124841248512486124871248812489124901249112492124931249412495124961249712498124991250012501125021250312504125051250612507125081250912510125111251212513125141251512516125171251812519125201252112522125231252412525125261252712528125291253012531125321253312534125351253612537125381253912540125411254212543125441254512546125471254812549125501255112552125531255412555125561255712558125591256012561125621256312564125651256612567125681256912570125711257212573125741257512576125771257812579125801258112582125831258412585125861258712588125891259012591125921259312594125951259612597125981259912600126011260212603126041260512606126071260812609126101261112612126131261412615126161261712618126191262012621126221262312624126251262612627126281262912630126311263212633126341263512636126371263812639126401264112642126431264412645126461264712648126491265012651126521265312654126551265612657126581265912660126611266212663126641266512666126671266812669126701267112672126731267412675126761267712678126791268012681126821268312684126851268612687126881268912690126911269212693126941269512696126971269812699127001270112702127031270412705127061270712708127091271012711127121271312714127151271612717127181271912720127211272212723127241272512726127271272812729127301273112732127331273412735127361273712738127391274012741127421274312744127451274612747127481274912750127511275212753127541275512756127571275812759127601276112762127631276412765127661276712768127691277012771127721277312774127751277612777127781277912780127811278212783127841278512786127871278812789127901279112792127931279412795127961279712798127991280012801128021280312804128051280612807128081280912810128111281212813128141281512816128171281812819128201282112822128231282412825128261282712828128291283012831128321283312834128351283612837128381283912840128411284212843128441284512846128471284812849128501285112852128531285412855128561285712858128591286012861128621286312864128651286612867128681286912870128711287212873128741287512876128771287812879128801288112882128831288412885128861288712888128891289012891128921289312894128951289612897128981289912900129011290212903129041290512906129071290812909129101291112912129131291412915129161291712918129191292012921129221292312924129251292612927129281292912930129311293212933129341293512936129371293812939129401294112942129431294412945129461294712948129491295012951129521295312954129551295612957129581295912960129611296212963129641296512966129671296812969129701297112972129731297412975129761297712978129791298012981129821298312984129851298612987129881298912990129911299212993129941299512996129971299812999130001300113002130031300413005130061300713008130091301013011130121301313014130151301613017130181301913020130211302213023130241302513026130271302813029130301303113032130331303413035130361303713038130391304013041130421304313044130451304613047130481304913050130511305213053130541305513056130571305813059130601306113062130631306413065130661306713068130691307013071130721307313074130751307613077130781307913080130811308213083130841308513086130871308813089130901309113092130931309413095130961309713098130991310013101131021310313104131051310613107131081310913110131111311213113131141311513116131171311813119131201312113122131231312413125131261312713128131291313013131131321313313134131351313613137131381313913140131411314213143131441314513146131471314813149131501315113152131531315413155131561315713158131591316013161131621316313164131651316613167131681316913170131711317213173131741317513176131771317813179131801318113182131831318413185131861318713188131891319013191131921319313194131951319613197131981319913200132011320213203132041320513206132071320813209132101321113212132131321413215132161321713218132191322013221132221322313224132251322613227132281322913230132311323213233132341323513236132371323813239132401324113242132431324413245132461324713248132491325013251132521325313254132551325613257132581325913260132611326213263132641326513266132671326813269132701327113272132731327413275132761327713278132791328013281132821328313284132851328613287132881328913290132911329213293132941329513296132971329813299133001330113302133031330413305133061330713308133091331013311133121331313314133151331613317133181331913320133211332213323133241332513326133271332813329133301333113332133331333413335133361333713338133391334013341133421334313344133451334613347133481334913350133511335213353133541335513356133571335813359133601336113362133631336413365133661336713368133691337013371133721337313374133751337613377133781337913380133811338213383133841338513386133871338813389133901339113392133931339413395133961339713398133991340013401134021340313404134051340613407134081340913410134111341213413134141341513416134171341813419134201342113422134231342413425134261342713428134291343013431134321343313434134351343613437134381343913440134411344213443134441344513446134471344813449134501345113452134531345413455134561345713458134591346013461134621346313464134651346613467134681346913470134711347213473134741347513476134771347813479134801348113482134831348413485134861348713488134891349013491134921349313494134951349613497134981349913500135011350213503135041350513506135071350813509135101351113512135131351413515135161351713518135191352013521135221352313524135251352613527135281352913530135311353213533135341353513536135371353813539135401354113542135431354413545135461354713548135491355013551135521355313554135551355613557135581355913560135611356213563135641356513566135671356813569135701357113572135731357413575135761357713578135791358013581135821358313584135851358613587135881358913590135911359213593135941359513596135971359813599136001360113602136031360413605136061360713608136091361013611136121361313614136151361613617136181361913620136211362213623136241362513626136271362813629136301363113632136331363413635136361363713638136391364013641136421364313644136451364613647136481364913650136511365213653136541365513656136571365813659136601366113662136631366413665136661366713668136691367013671136721367313674136751367613677136781367913680136811368213683136841368513686136871368813689136901369113692136931369413695136961369713698136991370013701137021370313704137051370613707137081370913710137111371213713137141371513716137171371813719137201372113722137231372413725137261372713728137291373013731137321373313734137351373613737137381373913740137411374213743137441374513746137471374813749137501375113752137531375413755137561375713758137591376013761137621376313764137651376613767137681376913770137711377213773137741377513776137771377813779137801378113782137831378413785137861378713788137891379013791137921379313794137951379613797137981379913800138011380213803138041380513806138071380813809138101381113812138131381413815138161381713818138191382013821138221382313824138251382613827138281382913830138311383213833138341383513836138371383813839138401384113842138431384413845138461384713848138491385013851138521385313854138551385613857138581385913860138611386213863138641386513866138671386813869138701387113872138731387413875138761387713878138791388013881138821388313884138851388613887138881388913890138911389213893138941389513896138971389813899139001390113902139031390413905139061390713908139091391013911139121391313914139151391613917139181391913920139211392213923139241392513926139271392813929139301393113932139331393413935139361393713938139391394013941139421394313944139451394613947139481394913950139511395213953139541395513956139571395813959139601396113962139631396413965139661396713968139691397013971139721397313974139751397613977139781397913980139811398213983139841398513986139871398813989139901399113992139931399413995139961399713998139991400014001140021400314004140051400614007140081400914010140111401214013140141401514016140171401814019140201402114022140231402414025140261402714028140291403014031140321403314034140351403614037140381403914040140411404214043140441404514046140471404814049140501405114052140531405414055140561405714058140591406014061140621406314064140651406614067140681406914070140711407214073140741407514076140771407814079140801408114082140831408414085140861408714088140891409014091140921409314094140951409614097140981409914100141011410214103141041410514106141071410814109141101411114112141131411414115141161411714118141191412014121141221412314124141251412614127141281412914130141311413214133141341413514136141371413814139141401414114142141431414414145141461414714148141491415014151141521415314154141551415614157141581415914160141611416214163141641416514166141671416814169141701417114172141731417414175141761417714178141791418014181141821418314184141851418614187141881418914190141911419214193141941419514196141971419814199142001420114202142031420414205142061420714208142091421014211142121421314214142151421614217142181421914220142211422214223142241422514226142271422814229142301423114232142331423414235142361423714238142391424014241142421424314244142451424614247142481424914250142511425214253142541425514256142571425814259142601426114262142631426414265142661426714268142691427014271142721427314274142751427614277142781427914280142811428214283142841428514286142871428814289142901429114292142931429414295142961429714298142991430014301143021430314304143051430614307143081430914310143111431214313143141431514316143171431814319143201432114322143231432414325143261432714328143291433014331143321433314334143351433614337143381433914340143411434214343143441434514346143471434814349143501435114352143531435414355143561435714358143591436014361143621436314364143651436614367143681436914370143711437214373143741437514376143771437814379143801438114382143831438414385143861438714388143891439014391143921439314394143951439614397143981439914400144011440214403144041440514406144071440814409144101441114412144131441414415144161441714418144191442014421144221442314424144251442614427144281442914430144311443214433144341443514436144371443814439144401444114442144431444414445144461444714448144491445014451144521445314454144551445614457144581445914460144611446214463144641446514466144671446814469144701447114472144731447414475144761447714478144791448014481144821448314484144851448614487144881448914490144911449214493144941449514496144971449814499145001450114502145031450414505145061450714508145091451014511145121451314514145151451614517145181451914520145211452214523145241452514526145271452814529145301453114532145331453414535145361453714538145391454014541145421454314544145451454614547145481454914550145511455214553145541455514556145571455814559145601456114562145631456414565145661456714568145691457014571145721457314574145751457614577145781457914580145811458214583145841458514586145871458814589145901459114592145931459414595145961459714598145991460014601146021460314604146051460614607146081460914610146111461214613146141461514616146171461814619146201462114622146231462414625146261462714628146291463014631146321463314634146351463614637146381463914640146411464214643146441464514646146471464814649146501465114652146531465414655146561465714658146591466014661146621466314664146651466614667146681466914670146711467214673146741467514676146771467814679146801468114682146831468414685146861468714688146891469014691146921469314694146951469614697146981469914700147011470214703147041470514706147071470814709147101471114712147131471414715147161471714718147191472014721147221472314724147251472614727147281472914730147311473214733147341473514736147371473814739147401474114742147431474414745147461474714748147491475014751147521475314754147551475614757147581475914760147611476214763147641476514766147671476814769147701477114772147731477414775147761477714778147791478014781147821478314784147851478614787147881478914790147911479214793147941479514796147971479814799148001480114802148031480414805148061480714808148091481014811148121481314814148151481614817148181481914820148211482214823148241482514826148271482814829148301483114832148331483414835148361483714838148391484014841148421484314844148451484614847148481484914850148511485214853148541485514856148571485814859148601486114862148631486414865148661486714868148691487014871148721487314874148751487614877148781487914880148811488214883148841488514886148871488814889148901489114892148931489414895148961489714898148991490014901149021490314904149051490614907149081490914910149111491214913149141491514916149171491814919149201492114922149231492414925149261492714928149291493014931149321493314934149351493614937149381493914940149411494214943149441494514946149471494814949149501495114952149531495414955149561495714958149591496014961149621496314964149651496614967149681496914970149711497214973149741497514976149771497814979149801498114982149831498414985149861498714988149891499014991149921499314994149951499614997149981499915000150011500215003150041500515006150071500815009150101501115012150131501415015150161501715018150191502015021150221502315024150251502615027150281502915030150311503215033150341503515036150371503815039150401504115042150431504415045150461504715048150491505015051150521505315054150551505615057150581505915060150611506215063150641506515066150671506815069150701507115072150731507415075150761507715078150791508015081150821508315084150851508615087150881508915090150911509215093150941509515096150971509815099151001510115102151031510415105151061510715108151091511015111151121511315114151151511615117151181511915120151211512215123151241512515126151271512815129151301513115132151331513415135151361513715138151391514015141151421514315144151451514615147151481514915150151511515215153151541515515156151571515815159151601516115162151631516415165151661516715168151691517015171151721517315174151751517615177151781517915180151811518215183151841518515186151871518815189151901519115192151931519415195151961519715198151991520015201152021520315204152051520615207152081520915210152111521215213152141521515216152171521815219152201522115222152231522415225152261522715228152291523015231152321523315234152351523615237152381523915240152411524215243152441524515246152471524815249152501525115252152531525415255152561525715258152591526015261152621526315264152651526615267152681526915270152711527215273152741527515276152771527815279152801528115282152831528415285152861528715288152891529015291152921529315294152951529615297152981529915300153011530215303153041530515306153071530815309153101531115312153131531415315153161531715318153191532015321153221532315324153251532615327153281532915330153311533215333153341533515336153371533815339153401534115342153431534415345153461534715348153491535015351153521535315354153551535615357153581535915360153611536215363153641536515366153671536815369153701537115372153731537415375153761537715378153791538015381153821538315384153851538615387153881538915390153911539215393153941539515396153971539815399154001540115402154031540415405154061540715408154091541015411154121541315414154151541615417154181541915420154211542215423154241542515426154271542815429154301543115432154331543415435154361543715438154391544015441154421544315444154451544615447154481544915450154511545215453154541545515456154571545815459154601546115462154631546415465154661546715468154691547015471154721547315474154751547615477154781547915480154811548215483154841548515486154871548815489154901549115492154931549415495154961549715498154991550015501155021550315504155051550615507155081550915510155111551215513155141551515516155171551815519155201552115522155231552415525155261552715528155291553015531155321553315534155351553615537155381553915540155411554215543155441554515546155471554815549155501555115552155531555415555155561555715558155591556015561155621556315564155651556615567155681556915570155711557215573155741557515576155771557815579155801558115582155831558415585155861558715588155891559015591155921559315594155951559615597155981559915600156011560215603156041560515606156071560815609156101561115612156131561415615156161561715618156191562015621156221562315624156251562615627156281562915630156311563215633156341563515636156371563815639156401564115642156431564415645156461564715648156491565015651156521565315654156551565615657156581565915660156611566215663156641566515666156671566815669156701567115672156731567415675156761567715678156791568015681156821568315684156851568615687156881568915690156911569215693156941569515696156971569815699157001570115702157031570415705157061570715708157091571015711157121571315714157151571615717157181571915720157211572215723157241572515726157271572815729157301573115732157331573415735157361573715738157391574015741157421574315744157451574615747157481574915750157511575215753157541575515756157571575815759157601576115762157631576415765157661576715768157691577015771157721577315774157751577615777157781577915780157811578215783157841578515786157871578815789157901579115792157931579415795157961579715798157991580015801158021580315804158051580615807158081580915810158111581215813158141581515816158171581815819158201582115822158231582415825158261582715828158291583015831158321583315834158351583615837158381583915840158411584215843158441584515846158471584815849158501585115852158531585415855158561585715858158591586015861158621586315864158651586615867158681586915870158711587215873158741587515876158771587815879158801588115882158831588415885158861588715888158891589015891158921589315894158951589615897158981589915900159011590215903159041590515906159071590815909159101591115912159131591415915159161591715918159191592015921159221592315924159251592615927159281592915930159311593215933159341593515936159371593815939159401594115942159431594415945159461594715948159491595015951159521595315954159551595615957159581595915960159611596215963159641596515966159671596815969159701597115972159731597415975159761597715978159791598015981159821598315984159851598615987159881598915990159911599215993159941599515996159971599815999160001600116002160031600416005160061600716008160091601016011160121601316014160151601616017160181601916020160211602216023160241602516026160271602816029160301603116032160331603416035160361603716038160391604016041160421604316044160451604616047160481604916050160511605216053160541605516056160571605816059160601606116062160631606416065160661606716068160691607016071160721607316074160751607616077160781607916080160811608216083160841608516086160871608816089160901609116092160931609416095160961609716098160991610016101161021610316104161051610616107161081610916110161111611216113161141611516116161171611816119161201612116122161231612416125161261612716128161291613016131161321613316134161351613616137161381613916140161411614216143161441614516146161471614816149161501615116152161531615416155161561615716158161591616016161161621616316164161651616616167161681616916170161711617216173161741617516176161771617816179161801618116182161831618416185161861618716188161891619016191161921619316194161951619616197161981619916200162011620216203162041620516206162071620816209162101621116212162131621416215162161621716218162191622016221162221622316224162251622616227162281622916230162311623216233162341623516236162371623816239162401624116242162431624416245162461624716248162491625016251162521625316254162551625616257162581625916260162611626216263162641626516266162671626816269162701627116272162731627416275162761627716278162791628016281162821628316284162851628616287162881628916290162911629216293162941629516296162971629816299163001630116302163031630416305163061630716308163091631016311163121631316314163151631616317163181631916320163211632216323163241632516326163271632816329163301633116332163331633416335163361633716338163391634016341163421634316344163451634616347163481634916350163511635216353163541635516356163571635816359163601636116362163631636416365163661636716368163691637016371163721637316374163751637616377163781637916380163811638216383163841638516386163871638816389163901639116392163931639416395163961639716398163991640016401164021640316404164051640616407164081640916410164111641216413164141641516416164171641816419164201642116422164231642416425164261642716428164291643016431164321643316434164351643616437164381643916440164411644216443164441644516446164471644816449164501645116452164531645416455164561645716458164591646016461164621646316464164651646616467164681646916470164711647216473164741647516476164771647816479164801648116482164831648416485164861648716488164891649016491164921649316494164951649616497164981649916500165011650216503165041650516506165071650816509165101651116512165131651416515165161651716518165191652016521165221652316524165251652616527165281652916530165311653216533165341653516536165371653816539165401654116542165431654416545165461654716548165491655016551165521655316554165551655616557165581655916560165611656216563165641656516566165671656816569165701657116572165731657416575165761657716578165791658016581165821658316584165851658616587165881658916590165911659216593165941659516596165971659816599166001660116602166031660416605166061660716608166091661016611166121661316614166151661616617166181661916620166211662216623166241662516626166271662816629166301663116632166331663416635166361663716638166391664016641166421664316644166451664616647166481664916650166511665216653166541665516656166571665816659166601666116662166631666416665166661666716668166691667016671166721667316674166751667616677166781667916680166811668216683166841668516686166871668816689166901669116692166931669416695166961669716698166991670016701167021670316704167051670616707167081670916710167111671216713167141671516716167171671816719167201672116722167231672416725167261672716728167291673016731167321673316734167351673616737167381673916740167411674216743167441674516746167471674816749167501675116752167531675416755167561675716758167591676016761167621676316764167651676616767167681676916770167711677216773167741677516776167771677816779167801678116782167831678416785167861678716788167891679016791167921679316794167951679616797167981679916800168011680216803168041680516806168071680816809168101681116812168131681416815168161681716818168191682016821168221682316824168251682616827168281682916830168311683216833168341683516836168371683816839168401684116842168431684416845168461684716848168491685016851168521685316854168551685616857168581685916860168611686216863168641686516866168671686816869168701687116872168731687416875168761687716878168791688016881168821688316884168851688616887168881688916890168911689216893168941689516896168971689816899169001690116902169031690416905169061690716908169091691016911169121691316914169151691616917169181691916920169211692216923169241692516926169271692816929169301693116932169331693416935169361693716938169391694016941169421694316944169451694616947169481694916950169511695216953169541695516956169571695816959169601696116962169631696416965169661696716968169691697016971169721697316974169751697616977169781697916980169811698216983169841698516986169871698816989169901699116992169931699416995169961699716998169991700017001170021700317004170051700617007170081700917010170111701217013170141701517016170171701817019170201702117022170231702417025170261702717028170291703017031170321703317034170351703617037170381703917040170411704217043170441704517046170471704817049170501705117052170531705417055170561705717058170591706017061170621706317064170651706617067170681706917070170711707217073170741707517076170771707817079170801708117082170831708417085170861708717088170891709017091170921709317094170951709617097170981709917100171011710217103171041710517106171071710817109171101711117112171131711417115171161711717118171191712017121171221712317124171251712617127171281712917130171311713217133171341713517136171371713817139171401714117142171431714417145171461714717148171491715017151171521715317154171551715617157171581715917160171611716217163171641716517166171671716817169171701717117172171731717417175171761717717178171791718017181171821718317184171851718617187171881718917190171911719217193171941719517196171971719817199172001720117202172031720417205172061720717208172091721017211172121721317214172151721617217172181721917220172211722217223172241722517226172271722817229172301723117232172331723417235172361723717238172391724017241172421724317244172451724617247172481724917250172511725217253172541725517256172571725817259172601726117262172631726417265172661726717268172691727017271172721727317274172751727617277172781727917280172811728217283172841728517286172871728817289172901729117292172931729417295172961729717298172991730017301173021730317304173051730617307173081730917310173111731217313173141731517316173171731817319173201732117322173231732417325173261732717328173291733017331173321733317334173351733617337173381733917340173411734217343173441734517346173471734817349173501735117352173531735417355173561735717358173591736017361173621736317364173651736617367173681736917370173711737217373173741737517376173771737817379173801738117382173831738417385173861738717388173891739017391173921739317394173951739617397173981739917400174011740217403174041740517406174071740817409174101741117412174131741417415174161741717418174191742017421174221742317424174251742617427174281742917430174311743217433174341743517436174371743817439174401744117442174431744417445174461744717448174491745017451174521745317454174551745617457174581745917460174611746217463174641746517466174671746817469174701747117472174731747417475174761747717478174791748017481174821748317484174851748617487174881748917490174911749217493174941749517496174971749817499175001750117502175031750417505175061750717508175091751017511175121751317514175151751617517175181751917520175211752217523175241752517526175271752817529175301753117532175331753417535175361753717538175391754017541175421754317544175451754617547175481754917550175511755217553175541755517556175571755817559175601756117562175631756417565175661756717568175691757017571175721757317574175751757617577175781757917580175811758217583175841758517586175871758817589175901759117592175931759417595175961759717598175991760017601176021760317604176051760617607176081760917610176111761217613176141761517616176171761817619176201762117622176231762417625176261762717628176291763017631176321763317634176351763617637176381763917640176411764217643176441764517646176471764817649176501765117652176531765417655176561765717658176591766017661176621766317664176651766617667176681766917670176711767217673176741767517676176771767817679176801768117682176831768417685176861768717688176891769017691176921769317694176951769617697176981769917700177011770217703177041770517706177071770817709177101771117712177131771417715177161771717718177191772017721177221772317724177251772617727177281772917730177311773217733177341773517736177371773817739177401774117742177431774417745177461774717748177491775017751177521775317754177551775617757177581775917760177611776217763177641776517766177671776817769177701777117772177731777417775177761777717778177791778017781177821778317784177851778617787177881778917790177911779217793177941779517796177971779817799178001780117802178031780417805178061780717808178091781017811178121781317814178151781617817178181781917820178211782217823178241782517826178271782817829178301783117832178331783417835178361783717838178391784017841178421784317844178451784617847178481784917850178511785217853178541785517856178571785817859178601786117862178631786417865178661786717868178691787017871178721787317874178751787617877178781787917880178811788217883178841788517886178871788817889178901789117892178931789417895178961789717898178991790017901179021790317904179051790617907179081790917910179111791217913179141791517916179171791817919179201792117922179231792417925179261792717928179291793017931179321793317934179351793617937179381793917940179411794217943179441794517946179471794817949179501795117952179531795417955179561795717958179591796017961179621796317964179651796617967179681796917970179711797217973179741797517976179771797817979179801798117982179831798417985179861798717988179891799017991179921799317994179951799617997179981799918000180011800218003180041800518006180071800818009180101801118012180131801418015180161801718018180191802018021180221802318024180251802618027180281802918030180311803218033180341803518036180371803818039180401804118042180431804418045180461804718048180491805018051180521805318054180551805618057180581805918060180611806218063180641806518066180671806818069180701807118072180731807418075180761807718078180791808018081180821808318084180851808618087180881808918090180911809218093180941809518096180971809818099181001810118102181031810418105181061810718108181091811018111181121811318114181151811618117181181811918120181211812218123181241812518126181271812818129181301813118132181331813418135181361813718138181391814018141181421814318144181451814618147181481814918150181511815218153181541815518156181571815818159181601816118162181631816418165181661816718168181691817018171181721817318174181751817618177181781817918180181811818218183181841818518186181871818818189181901819118192181931819418195181961819718198181991820018201182021820318204182051820618207182081820918210182111821218213182141821518216182171821818219182201822118222182231822418225182261822718228182291823018231182321823318234182351823618237182381823918240182411824218243182441824518246182471824818249182501825118252182531825418255182561825718258182591826018261182621826318264182651826618267182681826918270182711827218273182741827518276182771827818279182801828118282182831828418285182861828718288182891829018291182921829318294182951829618297182981829918300183011830218303183041830518306183071830818309183101831118312183131831418315183161831718318183191832018321183221832318324183251832618327183281832918330183311833218333183341833518336183371833818339183401834118342183431834418345183461834718348183491835018351183521835318354183551835618357183581835918360183611836218363183641836518366183671836818369183701837118372183731837418375183761837718378183791838018381183821838318384183851838618387183881838918390183911839218393183941839518396183971839818399184001840118402184031840418405184061840718408184091841018411184121841318414184151841618417184181841918420184211842218423184241842518426184271842818429184301843118432184331843418435184361843718438184391844018441184421844318444184451844618447184481844918450184511845218453184541845518456184571845818459184601846118462184631846418465184661846718468184691847018471184721847318474184751847618477184781847918480184811848218483184841848518486184871848818489184901849118492184931849418495184961849718498184991850018501185021850318504185051850618507185081850918510185111851218513185141851518516185171851818519185201852118522185231852418525185261852718528185291853018531185321853318534185351853618537185381853918540185411854218543185441854518546185471854818549185501855118552185531855418555185561855718558185591856018561185621856318564185651856618567185681856918570185711857218573185741857518576185771857818579185801858118582185831858418585185861858718588185891859018591185921859318594185951859618597185981859918600186011860218603186041860518606186071860818609186101861118612186131861418615186161861718618186191862018621186221862318624186251862618627186281862918630186311863218633186341863518636186371863818639186401864118642186431864418645186461864718648186491865018651186521865318654186551865618657186581865918660186611866218663186641866518666186671866818669186701867118672186731867418675186761867718678186791868018681186821868318684186851868618687186881868918690186911869218693186941869518696186971869818699187001870118702187031870418705187061870718708187091871018711187121871318714187151871618717187181871918720187211872218723187241872518726187271872818729187301873118732187331873418735187361873718738187391874018741187421874318744187451874618747187481874918750187511875218753187541875518756187571875818759187601876118762187631876418765187661876718768187691877018771187721877318774187751877618777187781877918780187811878218783187841878518786187871878818789187901879118792187931879418795187961879718798187991880018801188021880318804188051880618807188081880918810188111881218813188141881518816188171881818819188201882118822188231882418825188261882718828188291883018831188321883318834188351883618837188381883918840188411884218843188441884518846188471884818849188501885118852188531885418855188561885718858188591886018861188621886318864188651886618867188681886918870188711887218873188741887518876188771887818879188801888118882188831888418885188861888718888188891889018891188921889318894188951889618897188981889918900189011890218903189041890518906189071890818909189101891118912189131891418915189161891718918189191892018921189221892318924189251892618927189281892918930189311893218933189341893518936189371893818939189401894118942189431894418945189461894718948189491895018951189521895318954189551895618957189581895918960189611896218963189641896518966189671896818969189701897118972189731897418975189761897718978189791898018981189821898318984189851898618987189881898918990189911899218993189941899518996189971899818999190001900119002190031900419005190061900719008190091901019011190121901319014190151901619017190181901919020190211902219023190241902519026190271902819029190301903119032190331903419035190361903719038190391904019041190421904319044190451904619047190481904919050190511905219053190541905519056190571905819059190601906119062190631906419065190661906719068190691907019071190721907319074190751907619077190781907919080190811908219083190841908519086190871908819089190901909119092190931909419095190961909719098190991910019101191021910319104191051910619107191081910919110191111911219113191141911519116191171911819119191201912119122191231912419125191261912719128191291913019131191321913319134191351913619137191381913919140191411914219143191441914519146191471914819149191501915119152191531915419155191561915719158191591916019161191621916319164191651916619167191681916919170191711917219173191741917519176191771917819179191801918119182191831918419185191861918719188191891919019191191921919319194191951919619197191981919919200192011920219203192041920519206192071920819209192101921119212192131921419215192161921719218192191922019221192221922319224192251922619227192281922919230192311923219233192341923519236192371923819239192401924119242192431924419245192461924719248192491925019251192521925319254192551925619257192581925919260192611926219263192641926519266192671926819269192701927119272192731927419275192761927719278192791928019281192821928319284192851928619287192881928919290192911929219293192941929519296192971929819299193001930119302193031930419305193061930719308193091931019311193121931319314193151931619317193181931919320193211932219323193241932519326193271932819329193301933119332193331933419335193361933719338193391934019341193421934319344193451934619347193481934919350193511935219353193541935519356193571935819359193601936119362193631936419365193661936719368193691937019371193721937319374193751937619377193781937919380193811938219383193841938519386193871938819389193901939119392193931939419395193961939719398193991940019401194021940319404194051940619407194081940919410194111941219413194141941519416194171941819419194201942119422194231942419425194261942719428194291943019431194321943319434194351943619437194381943919440194411944219443194441944519446194471944819449194501945119452194531945419455194561945719458194591946019461194621946319464194651946619467194681946919470194711947219473194741947519476194771947819479194801948119482194831948419485194861948719488194891949019491194921949319494194951949619497194981949919500195011950219503195041950519506195071950819509195101951119512195131951419515195161951719518195191952019521195221952319524195251952619527195281952919530195311953219533195341953519536195371953819539195401954119542195431954419545195461954719548195491955019551195521955319554195551955619557195581955919560195611956219563195641956519566195671956819569195701957119572195731957419575195761957719578195791958019581195821958319584195851958619587195881958919590195911959219593195941959519596195971959819599196001960119602196031960419605196061960719608196091961019611196121961319614196151961619617196181961919620196211962219623196241962519626196271962819629196301963119632196331963419635196361963719638196391964019641196421964319644196451964619647196481964919650196511965219653196541965519656196571965819659196601966119662196631966419665196661966719668196691967019671196721967319674196751967619677196781967919680196811968219683196841968519686196871968819689196901969119692196931969419695196961969719698196991970019701197021970319704197051970619707197081970919710197111971219713197141971519716197171971819719197201972119722197231972419725197261972719728197291973019731197321973319734197351973619737197381973919740197411974219743197441974519746197471974819749197501975119752197531975419755197561975719758197591976019761197621976319764197651976619767197681976919770197711977219773197741977519776197771977819779197801978119782197831978419785197861978719788197891979019791197921979319794197951979619797197981979919800198011980219803198041980519806198071980819809198101981119812198131981419815198161981719818198191982019821198221982319824198251982619827198281982919830198311983219833198341983519836198371983819839198401984119842198431984419845198461984719848198491985019851198521985319854198551985619857198581985919860198611986219863198641986519866198671986819869198701987119872198731987419875198761987719878198791988019881198821988319884198851988619887198881988919890198911989219893198941989519896198971989819899199001990119902199031990419905199061990719908199091991019911199121991319914199151991619917199181991919920199211992219923199241992519926199271992819929199301993119932199331993419935199361993719938199391994019941199421994319944199451994619947199481994919950199511995219953199541995519956199571995819959199601996119962199631996419965199661996719968199691997019971199721997319974199751997619977199781997919980199811998219983199841998519986199871998819989199901999119992199931999419995199961999719998199992000020001200022000320004200052000620007200082000920010200112001220013200142001520016200172001820019200202002120022200232002420025200262002720028200292003020031200322003320034200352003620037200382003920040200412004220043200442004520046200472004820049200502005120052200532005420055200562005720058200592006020061200622006320064200652006620067200682006920070200712007220073200742007520076200772007820079200802008120082200832008420085200862008720088200892009020091200922009320094200952009620097200982009920100201012010220103201042010520106201072010820109201102011120112201132011420115201162011720118201192012020121201222012320124201252012620127201282012920130201312013220133201342013520136201372013820139201402014120142201432014420145201462014720148201492015020151201522015320154201552015620157201582015920160201612016220163201642016520166201672016820169201702017120172201732017420175201762017720178201792018020181201822018320184201852018620187201882018920190201912019220193201942019520196201972019820199202002020120202202032020420205202062020720208202092021020211202122021320214202152021620217202182021920220202212022220223202242022520226202272022820229202302023120232202332023420235202362023720238202392024020241202422024320244202452024620247202482024920250202512025220253202542025520256202572025820259202602026120262202632026420265202662026720268202692027020271202722027320274202752027620277202782027920280202812028220283202842028520286202872028820289202902029120292202932029420295202962029720298202992030020301203022030320304203052030620307203082030920310203112031220313203142031520316203172031820319203202032120322203232032420325203262032720328203292033020331203322033320334203352033620337203382033920340203412034220343203442034520346203472034820349203502035120352203532035420355203562035720358203592036020361203622036320364203652036620367203682036920370203712037220373203742037520376203772037820379203802038120382203832038420385203862038720388203892039020391203922039320394203952039620397203982039920400204012040220403204042040520406204072040820409204102041120412204132041420415204162041720418204192042020421204222042320424204252042620427204282042920430204312043220433204342043520436204372043820439204402044120442204432044420445204462044720448204492045020451204522045320454204552045620457204582045920460204612046220463204642046520466204672046820469204702047120472204732047420475204762047720478204792048020481204822048320484204852048620487204882048920490204912049220493204942049520496204972049820499205002050120502205032050420505205062050720508205092051020511205122051320514205152051620517205182051920520205212052220523205242052520526205272052820529205302053120532205332053420535205362053720538205392054020541205422054320544205452054620547205482054920550205512055220553205542055520556205572055820559205602056120562205632056420565205662056720568205692057020571205722057320574205752057620577205782057920580205812058220583205842058520586205872058820589205902059120592205932059420595205962059720598205992060020601206022060320604206052060620607206082060920610206112061220613206142061520616206172061820619206202062120622206232062420625206262062720628206292063020631206322063320634206352063620637206382063920640206412064220643206442064520646206472064820649206502065120652206532065420655206562065720658206592066020661206622066320664206652066620667206682066920670206712067220673206742067520676206772067820679206802068120682206832068420685206862068720688206892069020691206922069320694206952069620697206982069920700207012070220703207042070520706207072070820709207102071120712207132071420715207162071720718207192072020721207222072320724207252072620727207282072920730207312073220733207342073520736207372073820739207402074120742207432074420745207462074720748207492075020751207522075320754207552075620757207582075920760207612076220763207642076520766207672076820769207702077120772207732077420775207762077720778207792078020781207822078320784207852078620787207882078920790207912079220793207942079520796207972079820799208002080120802208032080420805208062080720808208092081020811208122081320814208152081620817208182081920820208212082220823208242082520826208272082820829208302083120832208332083420835208362083720838208392084020841208422084320844208452084620847208482084920850208512085220853208542085520856208572085820859208602086120862208632086420865208662086720868208692087020871208722087320874208752087620877208782087920880208812088220883208842088520886208872088820889208902089120892208932089420895208962089720898208992090020901209022090320904209052090620907209082090920910209112091220913209142091520916209172091820919209202092120922209232092420925209262092720928209292093020931209322093320934209352093620937209382093920940209412094220943209442094520946209472094820949209502095120952209532095420955209562095720958209592096020961209622096320964209652096620967209682096920970209712097220973209742097520976209772097820979209802098120982209832098420985209862098720988209892099020991209922099320994209952099620997209982099921000210012100221003210042100521006210072100821009210102101121012210132101421015210162101721018210192102021021210222102321024210252102621027210282102921030210312103221033210342103521036210372103821039210402104121042210432104421045210462104721048210492105021051210522105321054210552105621057210582105921060210612106221063210642106521066210672106821069210702107121072210732107421075210762107721078210792108021081210822108321084210852108621087210882108921090210912109221093210942109521096210972109821099211002110121102211032110421105211062110721108211092111021111211122111321114211152111621117211182111921120211212112221123211242112521126211272112821129211302113121132211332113421135211362113721138211392114021141211422114321144211452114621147211482114921150211512115221153211542115521156211572115821159211602116121162211632116421165211662116721168211692117021171211722117321174211752117621177211782117921180211812118221183211842118521186211872118821189211902119121192211932119421195211962119721198211992120021201212022120321204212052120621207212082120921210212112121221213212142121521216212172121821219212202122121222212232122421225212262122721228212292123021231212322123321234212352123621237212382123921240212412124221243212442124521246212472124821249212502125121252212532125421255212562125721258212592126021261212622126321264212652126621267212682126921270212712127221273212742127521276212772127821279212802128121282212832128421285212862128721288212892129021291212922129321294212952129621297212982129921300213012130221303213042130521306213072130821309213102131121312213132131421315213162131721318213192132021321213222132321324213252132621327213282132921330213312133221333213342133521336213372133821339213402134121342213432134421345213462134721348213492135021351213522135321354213552135621357213582135921360213612136221363213642136521366213672136821369213702137121372213732137421375213762137721378213792138021381213822138321384213852138621387213882138921390213912139221393213942139521396213972139821399214002140121402214032140421405214062140721408214092141021411214122141321414214152141621417214182141921420214212142221423214242142521426214272142821429214302143121432214332143421435214362143721438214392144021441214422144321444214452144621447214482144921450214512145221453214542145521456214572145821459214602146121462214632146421465214662146721468214692147021471214722147321474214752147621477214782147921480214812148221483214842148521486214872148821489214902149121492214932149421495214962149721498214992150021501215022150321504215052150621507215082150921510215112151221513215142151521516215172151821519215202152121522215232152421525215262152721528215292153021531215322153321534215352153621537215382153921540215412154221543215442154521546215472154821549215502155121552215532155421555215562155721558215592156021561215622156321564215652156621567215682156921570215712157221573215742157521576215772157821579215802158121582215832158421585215862158721588215892159021591215922159321594215952159621597215982159921600216012160221603216042160521606216072160821609216102161121612216132161421615216162161721618216192162021621216222162321624216252162621627216282162921630216312163221633216342163521636216372163821639216402164121642216432164421645216462164721648216492165021651216522165321654216552165621657216582165921660216612166221663216642166521666216672166821669216702167121672216732167421675216762167721678216792168021681216822168321684216852168621687216882168921690216912169221693216942169521696216972169821699217002170121702217032170421705217062170721708217092171021711217122171321714217152171621717217182171921720217212172221723217242172521726217272172821729217302173121732217332173421735217362173721738217392174021741217422174321744217452174621747217482174921750217512175221753217542175521756217572175821759217602176121762217632176421765217662176721768217692177021771217722177321774217752177621777217782177921780217812178221783217842178521786217872178821789217902179121792217932179421795217962179721798217992180021801218022180321804218052180621807218082180921810218112181221813218142181521816218172181821819218202182121822218232182421825218262182721828218292183021831218322183321834218352183621837218382183921840218412184221843218442184521846218472184821849218502185121852218532185421855218562185721858218592186021861218622186321864218652186621867218682186921870218712187221873218742187521876218772187821879218802188121882218832188421885218862188721888218892189021891218922189321894218952189621897218982189921900219012190221903219042190521906219072190821909219102191121912219132191421915219162191721918219192192021921219222192321924219252192621927219282192921930219312193221933219342193521936219372193821939219402194121942219432194421945219462194721948219492195021951219522195321954219552195621957219582195921960219612196221963219642196521966219672196821969219702197121972219732197421975219762197721978219792198021981219822198321984219852198621987219882198921990219912199221993219942199521996219972199821999220002200122002220032200422005220062200722008220092201022011220122201322014220152201622017220182201922020220212202222023220242202522026220272202822029220302203122032220332203422035220362203722038220392204022041220422204322044220452204622047220482204922050220512205222053220542205522056220572205822059220602206122062220632206422065220662206722068220692207022071220722207322074220752207622077220782207922080220812208222083220842208522086220872208822089220902209122092220932209422095220962209722098220992210022101221022210322104221052210622107221082210922110221112211222113221142211522116221172211822119221202212122122221232212422125221262212722128221292213022131221322213322134221352213622137221382213922140221412214222143221442214522146221472214822149221502215122152221532215422155221562215722158221592216022161221622216322164221652216622167221682216922170221712217222173221742217522176221772217822179221802218122182221832218422185221862218722188221892219022191221922219322194221952219622197221982219922200222012220222203222042220522206222072220822209222102221122212222132221422215222162221722218222192222022221222222222322224222252222622227222282222922230222312223222233222342223522236222372223822239222402224122242222432224422245222462224722248222492225022251222522225322254222552225622257222582225922260222612226222263222642226522266222672226822269222702227122272222732227422275222762227722278222792228022281222822228322284222852228622287222882228922290222912229222293222942229522296222972229822299223002230122302223032230422305223062230722308223092231022311223122231322314223152231622317223182231922320223212232222323223242232522326223272232822329223302233122332223332233422335223362233722338223392234022341223422234322344223452234622347223482234922350223512235222353223542235522356223572235822359223602236122362223632236422365223662236722368223692237022371223722237322374223752237622377223782237922380223812238222383223842238522386223872238822389223902239122392223932239422395223962239722398223992240022401224022240322404224052240622407224082240922410224112241222413224142241522416224172241822419224202242122422224232242422425224262242722428224292243022431224322243322434224352243622437224382243922440224412244222443224442244522446224472244822449224502245122452224532245422455224562245722458224592246022461224622246322464224652246622467224682246922470224712247222473224742247522476224772247822479224802248122482224832248422485224862248722488224892249022491224922249322494224952249622497224982249922500225012250222503225042250522506225072250822509225102251122512225132251422515225162251722518225192252022521225222252322524225252252622527225282252922530225312253222533225342253522536225372253822539225402254122542225432254422545225462254722548225492255022551225522255322554225552255622557225582255922560225612256222563225642256522566225672256822569225702257122572225732257422575225762257722578225792258022581225822258322584225852258622587225882258922590225912259222593225942259522596225972259822599226002260122602226032260422605226062260722608226092261022611226122261322614226152261622617226182261922620226212262222623226242262522626226272262822629226302263122632226332263422635226362263722638226392264022641226422264322644226452264622647226482264922650226512265222653226542265522656226572265822659226602266122662226632266422665226662266722668226692267022671226722267322674226752267622677226782267922680226812268222683226842268522686226872268822689226902269122692226932269422695226962269722698226992270022701227022270322704227052270622707227082270922710227112271222713227142271522716227172271822719227202272122722227232272422725227262272722728227292273022731227322273322734227352273622737227382273922740227412274222743227442274522746227472274822749227502275122752227532275422755227562275722758227592276022761227622276322764227652276622767227682276922770227712277222773227742277522776227772277822779227802278122782227832278422785227862278722788227892279022791227922279322794227952279622797227982279922800228012280222803228042280522806228072280822809228102281122812228132281422815228162281722818228192282022821228222282322824228252282622827228282282922830228312283222833228342283522836228372283822839228402284122842228432284422845228462284722848228492285022851228522285322854228552285622857228582285922860228612286222863228642286522866228672286822869228702287122872228732287422875228762287722878228792288022881228822288322884228852288622887228882288922890228912289222893228942289522896228972289822899229002290122902229032290422905229062290722908229092291022911229122291322914229152291622917229182291922920229212292222923229242292522926229272292822929229302293122932229332293422935229362293722938229392294022941229422294322944229452294622947229482294922950229512295222953229542295522956229572295822959229602296122962229632296422965229662296722968229692297022971229722297322974229752297622977229782297922980229812298222983229842298522986229872298822989229902299122992229932299422995229962299722998229992300023001230022300323004230052300623007230082300923010230112301223013230142301523016230172301823019230202302123022230232302423025230262302723028230292303023031230322303323034230352303623037230382303923040230412304223043230442304523046230472304823049230502305123052230532305423055230562305723058230592306023061230622306323064230652306623067230682306923070230712307223073230742307523076230772307823079230802308123082230832308423085230862308723088230892309023091230922309323094230952309623097230982309923100231012310223103231042310523106231072310823109231102311123112231132311423115231162311723118231192312023121231222312323124231252312623127231282312923130231312313223133231342313523136231372313823139231402314123142231432314423145231462314723148231492315023151231522315323154231552315623157231582315923160231612316223163231642316523166231672316823169231702317123172231732317423175231762317723178231792318023181231822318323184231852318623187231882318923190231912319223193231942319523196231972319823199232002320123202232032320423205232062320723208232092321023211232122321323214232152321623217232182321923220232212322223223232242322523226232272322823229232302323123232232332323423235232362323723238232392324023241232422324323244232452324623247232482324923250232512325223253232542325523256232572325823259232602326123262232632326423265232662326723268232692327023271232722327323274232752327623277232782327923280232812328223283232842328523286232872328823289232902329123292232932329423295232962329723298232992330023301233022330323304233052330623307233082330923310233112331223313233142331523316233172331823319233202332123322233232332423325233262332723328233292333023331233322333323334233352333623337233382333923340233412334223343233442334523346233472334823349233502335123352233532335423355233562335723358233592336023361233622336323364233652336623367233682336923370233712337223373233742337523376233772337823379233802338123382233832338423385233862338723388233892339023391233922339323394233952339623397233982339923400234012340223403234042340523406234072340823409234102341123412234132341423415234162341723418234192342023421234222342323424234252342623427234282342923430234312343223433234342343523436234372343823439234402344123442234432344423445234462344723448234492345023451234522345323454234552345623457234582345923460234612346223463234642346523466234672346823469234702347123472234732347423475234762347723478234792348023481234822348323484234852348623487234882348923490234912349223493234942349523496234972349823499235002350123502235032350423505235062350723508235092351023511235122351323514235152351623517235182351923520235212352223523235242352523526235272352823529235302353123532235332353423535235362353723538235392354023541235422354323544235452354623547235482354923550235512355223553235542355523556235572355823559235602356123562235632356423565235662356723568235692357023571235722357323574235752357623577235782357923580235812358223583235842358523586235872358823589235902359123592235932359423595235962359723598235992360023601236022360323604236052360623607236082360923610236112361223613236142361523616236172361823619236202362123622236232362423625236262362723628236292363023631236322363323634236352363623637236382363923640236412364223643236442364523646236472364823649236502365123652236532365423655236562365723658236592366023661236622366323664236652366623667236682366923670236712367223673236742367523676236772367823679236802368123682236832368423685236862368723688236892369023691236922369323694236952369623697236982369923700237012370223703237042370523706237072370823709237102371123712237132371423715237162371723718237192372023721237222372323724237252372623727237282372923730237312373223733237342373523736237372373823739237402374123742237432374423745237462374723748237492375023751237522375323754237552375623757237582375923760237612376223763237642376523766237672376823769237702377123772237732377423775237762377723778237792378023781237822378323784237852378623787237882378923790237912379223793237942379523796237972379823799238002380123802238032380423805238062380723808238092381023811238122381323814238152381623817238182381923820238212382223823238242382523826238272382823829238302383123832238332383423835238362383723838238392384023841238422384323844238452384623847238482384923850238512385223853238542385523856238572385823859238602386123862238632386423865238662386723868238692387023871238722387323874238752387623877238782387923880238812388223883238842388523886238872388823889238902389123892238932389423895238962389723898238992390023901239022390323904239052390623907239082390923910239112391223913239142391523916239172391823919239202392123922239232392423925239262392723928239292393023931239322393323934239352393623937239382393923940239412394223943239442394523946239472394823949239502395123952239532395423955239562395723958239592396023961239622396323964239652396623967239682396923970239712397223973239742397523976239772397823979239802398123982239832398423985239862398723988239892399023991239922399323994239952399623997239982399924000240012400224003240042400524006240072400824009240102401124012240132401424015240162401724018240192402024021240222402324024240252402624027240282402924030240312403224033240342403524036240372403824039240402404124042240432404424045240462404724048240492405024051240522405324054240552405624057240582405924060240612406224063240642406524066240672406824069240702407124072240732407424075240762407724078240792408024081240822408324084240852408624087240882408924090240912409224093240942409524096240972409824099241002410124102241032410424105241062410724108241092411024111241122411324114241152411624117241182411924120241212412224123241242412524126241272412824129241302413124132241332413424135241362413724138241392414024141241422414324144241452414624147241482414924150241512415224153241542415524156241572415824159241602416124162241632416424165241662416724168241692417024171241722417324174241752417624177241782417924180241812418224183241842418524186241872418824189241902419124192241932419424195241962419724198241992420024201242022420324204242052420624207242082420924210242112421224213242142421524216242172421824219242202422124222242232422424225242262422724228242292423024231242322423324234242352423624237242382423924240242412424224243242442424524246242472424824249242502425124252242532425424255242562425724258242592426024261242622426324264242652426624267242682426924270242712427224273242742427524276242772427824279242802428124282242832428424285242862428724288242892429024291242922429324294242952429624297242982429924300243012430224303243042430524306243072430824309243102431124312243132431424315243162431724318243192432024321243222432324324243252432624327243282432924330243312433224333243342433524336243372433824339243402434124342243432434424345243462434724348243492435024351243522435324354243552435624357243582435924360243612436224363243642436524366243672436824369243702437124372243732437424375243762437724378243792438024381243822438324384243852438624387243882438924390243912439224393243942439524396243972439824399244002440124402244032440424405244062440724408244092441024411244122441324414244152441624417244182441924420244212442224423244242442524426244272442824429244302443124432244332443424435244362443724438244392444024441244422444324444244452444624447244482444924450244512445224453244542445524456244572445824459244602446124462244632446424465244662446724468244692447024471244722447324474244752447624477244782447924480244812448224483244842448524486244872448824489244902449124492244932449424495244962449724498244992450024501245022450324504245052450624507245082450924510245112451224513245142451524516245172451824519245202452124522245232452424525245262452724528245292453024531245322453324534245352453624537245382453924540245412454224543245442454524546245472454824549245502455124552245532455424555245562455724558245592456024561245622456324564245652456624567245682456924570245712457224573245742457524576245772457824579245802458124582245832458424585245862458724588245892459024591245922459324594245952459624597245982459924600246012460224603246042460524606246072460824609246102461124612246132461424615246162461724618246192462024621246222462324624246252462624627246282462924630246312463224633246342463524636246372463824639246402464124642246432464424645246462464724648246492465024651246522465324654246552465624657246582465924660246612466224663246642466524666246672466824669246702467124672246732467424675246762467724678246792468024681246822468324684246852468624687246882468924690246912469224693246942469524696246972469824699247002470124702247032470424705247062470724708247092471024711247122471324714247152471624717247182471924720247212472224723247242472524726247272472824729247302473124732247332473424735247362473724738247392474024741247422474324744247452474624747247482474924750247512475224753247542475524756247572475824759247602476124762247632476424765247662476724768247692477024771247722477324774247752477624777247782477924780247812478224783247842478524786247872478824789247902479124792247932479424795247962479724798247992480024801248022480324804248052480624807248082480924810248112481224813248142481524816248172481824819248202482124822248232482424825248262482724828248292483024831248322483324834248352483624837248382483924840248412484224843248442484524846248472484824849248502485124852248532485424855248562485724858248592486024861248622486324864248652486624867248682486924870248712487224873248742487524876248772487824879248802488124882248832488424885248862488724888248892489024891248922489324894248952489624897248982489924900249012490224903249042490524906249072490824909249102491124912249132491424915249162491724918249192492024921249222492324924249252492624927249282492924930249312493224933249342493524936249372493824939249402494124942249432494424945249462494724948249492495024951249522495324954249552495624957249582495924960249612496224963249642496524966249672496824969249702497124972249732497424975249762497724978249792498024981249822498324984249852498624987249882498924990249912499224993249942499524996249972499824999250002500125002250032500425005250062500725008250092501025011250122501325014250152501625017250182501925020250212502225023250242502525026250272502825029250302503125032250332503425035250362503725038250392504025041250422504325044250452504625047250482504925050250512505225053250542505525056250572505825059250602506125062250632506425065250662506725068250692507025071250722507325074250752507625077250782507925080250812508225083250842508525086250872508825089250902509125092250932509425095250962509725098250992510025101251022510325104251052510625107251082510925110251112511225113251142511525116251172511825119251202512125122251232512425125251262512725128251292513025131251322513325134251352513625137251382513925140251412514225143251442514525146251472514825149251502515125152251532515425155251562515725158251592516025161251622516325164251652516625167251682516925170251712517225173251742517525176251772517825179251802518125182251832518425185251862518725188251892519025191251922519325194251952519625197251982519925200252012520225203252042520525206252072520825209252102521125212252132521425215252162521725218252192522025221252222522325224252252522625227252282522925230252312523225233252342523525236252372523825239252402524125242252432524425245252462524725248252492525025251252522525325254252552525625257252582525925260252612526225263252642526525266252672526825269252702527125272252732527425275252762527725278252792528025281252822528325284252852528625287252882528925290252912529225293252942529525296252972529825299253002530125302253032530425305253062530725308253092531025311253122531325314253152531625317253182531925320253212532225323253242532525326253272532825329253302533125332253332533425335253362533725338253392534025341253422534325344253452534625347253482534925350253512535225353253542535525356253572535825359253602536125362253632536425365253662536725368253692537025371253722537325374253752537625377253782537925380253812538225383253842538525386253872538825389253902539125392253932539425395253962539725398253992540025401254022540325404254052540625407254082540925410254112541225413254142541525416254172541825419254202542125422254232542425425254262542725428254292543025431254322543325434254352543625437254382543925440254412544225443254442544525446254472544825449254502545125452254532545425455254562545725458254592546025461254622546325464254652546625467254682546925470254712547225473254742547525476254772547825479254802548125482254832548425485254862548725488254892549025491254922549325494254952549625497254982549925500255012550225503255042550525506255072550825509255102551125512255132551425515255162551725518255192552025521255222552325524255252552625527255282552925530255312553225533255342553525536255372553825539255402554125542255432554425545255462554725548255492555025551255522555325554255552555625557255582555925560255612556225563255642556525566255672556825569255702557125572255732557425575255762557725578255792558025581255822558325584255852558625587255882558925590255912559225593255942559525596255972559825599256002560125602256032560425605256062560725608256092561025611256122561325614256152561625617256182561925620256212562225623256242562525626256272562825629256302563125632256332563425635256362563725638256392564025641256422564325644256452564625647256482564925650256512565225653256542565525656256572565825659256602566125662256632566425665256662566725668256692567025671256722567325674256752567625677256782567925680256812568225683256842568525686256872568825689256902569125692256932569425695256962569725698256992570025701257022570325704257052570625707257082570925710257112571225713257142571525716257172571825719257202572125722257232572425725257262572725728257292573025731257322573325734257352573625737257382573925740257412574225743257442574525746257472574825749257502575125752257532575425755257562575725758257592576025761257622576325764257652576625767257682576925770257712577225773257742577525776257772577825779257802578125782257832578425785257862578725788257892579025791257922579325794257952579625797257982579925800258012580225803258042580525806258072580825809258102581125812258132581425815258162581725818258192582025821258222582325824258252582625827258282582925830258312583225833258342583525836258372583825839258402584125842258432584425845258462584725848258492585025851258522585325854258552585625857258582585925860258612586225863258642586525866258672586825869258702587125872258732587425875258762587725878258792588025881258822588325884258852588625887258882588925890258912589225893258942589525896258972589825899259002590125902259032590425905259062590725908259092591025911259122591325914259152591625917259182591925920259212592225923259242592525926259272592825929259302593125932259332593425935259362593725938259392594025941259422594325944259452594625947259482594925950259512595225953259542595525956259572595825959259602596125962259632596425965259662596725968259692597025971259722597325974259752597625977259782597925980259812598225983259842598525986259872598825989259902599125992259932599425995259962599725998259992600026001260022600326004260052600626007260082600926010260112601226013260142601526016260172601826019260202602126022260232602426025260262602726028260292603026031260322603326034260352603626037260382603926040260412604226043260442604526046260472604826049260502605126052260532605426055260562605726058260592606026061260622606326064260652606626067260682606926070260712607226073260742607526076260772607826079260802608126082260832608426085260862608726088260892609026091260922609326094260952609626097260982609926100261012610226103261042610526106261072610826109261102611126112261132611426115261162611726118261192612026121261222612326124261252612626127261282612926130261312613226133261342613526136261372613826139261402614126142261432614426145261462614726148261492615026151261522615326154261552615626157261582615926160261612616226163261642616526166261672616826169261702617126172261732617426175261762617726178261792618026181261822618326184261852618626187261882618926190261912619226193261942619526196261972619826199262002620126202262032620426205262062620726208262092621026211262122621326214262152621626217262182621926220262212622226223262242622526226262272622826229262302623126232262332623426235262362623726238262392624026241262422624326244262452624626247262482624926250262512625226253262542625526256262572625826259262602626126262262632626426265262662626726268262692627026271262722627326274262752627626277262782627926280262812628226283262842628526286262872628826289262902629126292262932629426295262962629726298262992630026301263022630326304263052630626307263082630926310263112631226313263142631526316263172631826319263202632126322263232632426325263262632726328263292633026331263322633326334263352633626337263382633926340263412634226343263442634526346263472634826349263502635126352263532635426355263562635726358263592636026361263622636326364263652636626367263682636926370263712637226373263742637526376263772637826379263802638126382263832638426385263862638726388263892639026391263922639326394263952639626397263982639926400264012640226403264042640526406264072640826409264102641126412264132641426415264162641726418264192642026421264222642326424264252642626427264282642926430264312643226433264342643526436264372643826439264402644126442264432644426445264462644726448264492645026451264522645326454264552645626457264582645926460264612646226463264642646526466264672646826469264702647126472264732647426475264762647726478264792648026481264822648326484264852648626487264882648926490264912649226493264942649526496264972649826499265002650126502265032650426505265062650726508265092651026511265122651326514265152651626517265182651926520265212652226523265242652526526265272652826529265302653126532265332653426535265362653726538265392654026541265422654326544265452654626547265482654926550265512655226553265542655526556265572655826559265602656126562265632656426565265662656726568265692657026571265722657326574265752657626577265782657926580265812658226583265842658526586265872658826589265902659126592265932659426595265962659726598265992660026601266022660326604266052660626607266082660926610266112661226613266142661526616266172661826619266202662126622266232662426625266262662726628266292663026631266322663326634266352663626637266382663926640266412664226643266442664526646266472664826649266502665126652266532665426655266562665726658266592666026661266622666326664266652666626667266682666926670266712667226673266742667526676266772667826679266802668126682266832668426685266862668726688266892669026691266922669326694266952669626697266982669926700267012670226703267042670526706267072670826709267102671126712267132671426715267162671726718267192672026721267222672326724267252672626727267282672926730267312673226733267342673526736267372673826739267402674126742267432674426745267462674726748267492675026751267522675326754267552675626757267582675926760267612676226763267642676526766267672676826769267702677126772267732677426775267762677726778267792678026781267822678326784267852678626787267882678926790267912679226793267942679526796267972679826799268002680126802268032680426805268062680726808268092681026811268122681326814268152681626817268182681926820268212682226823268242682526826268272682826829268302683126832268332683426835268362683726838268392684026841268422684326844268452684626847268482684926850268512685226853268542685526856268572685826859268602686126862268632686426865268662686726868268692687026871268722687326874268752687626877268782687926880268812688226883268842688526886268872688826889268902689126892268932689426895268962689726898268992690026901269022690326904269052690626907269082690926910269112691226913269142691526916269172691826919269202692126922269232692426925269262692726928269292693026931269322693326934269352693626937269382693926940269412694226943269442694526946269472694826949269502695126952269532695426955269562695726958269592696026961269622696326964269652696626967269682696926970269712697226973269742697526976269772697826979269802698126982269832698426985269862698726988269892699026991269922699326994269952699626997269982699927000270012700227003270042700527006270072700827009270102701127012270132701427015270162701727018270192702027021270222702327024270252702627027270282702927030270312703227033270342703527036270372703827039270402704127042270432704427045270462704727048270492705027051270522705327054270552705627057270582705927060270612706227063270642706527066270672706827069270702707127072270732707427075270762707727078270792708027081270822708327084270852708627087270882708927090270912709227093270942709527096270972709827099271002710127102271032710427105271062710727108271092711027111271122711327114271152711627117271182711927120271212712227123271242712527126271272712827129271302713127132271332713427135271362713727138271392714027141271422714327144271452714627147271482714927150271512715227153271542715527156271572715827159271602716127162271632716427165271662716727168271692717027171271722717327174271752717627177271782717927180271812718227183271842718527186271872718827189271902719127192271932719427195271962719727198271992720027201272022720327204272052720627207272082720927210272112721227213272142721527216272172721827219272202722127222272232722427225272262722727228272292723027231272322723327234272352723627237272382723927240272412724227243272442724527246272472724827249272502725127252272532725427255272562725727258272592726027261272622726327264272652726627267272682726927270272712727227273272742727527276272772727827279272802728127282272832728427285272862728727288272892729027291272922729327294272952729627297272982729927300273012730227303273042730527306273072730827309273102731127312273132731427315273162731727318273192732027321273222732327324273252732627327273282732927330273312733227333273342733527336273372733827339273402734127342273432734427345273462734727348273492735027351273522735327354273552735627357273582735927360273612736227363273642736527366273672736827369273702737127372273732737427375273762737727378273792738027381273822738327384273852738627387273882738927390273912739227393273942739527396273972739827399274002740127402274032740427405274062740727408274092741027411274122741327414274152741627417274182741927420274212742227423274242742527426274272742827429274302743127432274332743427435274362743727438274392744027441274422744327444274452744627447274482744927450274512745227453274542745527456274572745827459274602746127462274632746427465274662746727468274692747027471274722747327474274752747627477274782747927480274812748227483274842748527486274872748827489274902749127492274932749427495274962749727498274992750027501275022750327504275052750627507275082750927510275112751227513275142751527516275172751827519275202752127522275232752427525275262752727528275292753027531275322753327534275352753627537275382753927540275412754227543275442754527546275472754827549275502755127552275532755427555275562755727558275592756027561275622756327564275652756627567275682756927570275712757227573275742757527576275772757827579275802758127582275832758427585275862758727588275892759027591275922759327594275952759627597275982759927600276012760227603276042760527606276072760827609276102761127612276132761427615276162761727618276192762027621276222762327624276252762627627276282762927630276312763227633276342763527636276372763827639276402764127642276432764427645276462764727648276492765027651276522765327654276552765627657276582765927660276612766227663276642766527666276672766827669276702767127672276732767427675276762767727678276792768027681276822768327684276852768627687276882768927690276912769227693276942769527696276972769827699277002770127702277032770427705277062770727708277092771027711277122771327714277152771627717277182771927720277212772227723277242772527726277272772827729277302773127732277332773427735277362773727738277392774027741277422774327744277452774627747277482774927750277512775227753277542775527756277572775827759277602776127762277632776427765277662776727768277692777027771277722777327774277752777627777277782777927780277812778227783277842778527786277872778827789277902779127792277932779427795277962779727798277992780027801278022780327804278052780627807278082780927810278112781227813278142781527816278172781827819278202782127822278232782427825278262782727828278292783027831278322783327834278352783627837278382783927840278412784227843278442784527846278472784827849278502785127852278532785427855278562785727858278592786027861278622786327864278652786627867278682786927870278712787227873278742787527876278772787827879278802788127882278832788427885278862788727888278892789027891278922789327894278952789627897278982789927900279012790227903279042790527906279072790827909279102791127912279132791427915279162791727918279192792027921279222792327924279252792627927279282792927930279312793227933279342793527936279372793827939279402794127942279432794427945279462794727948279492795027951279522795327954279552795627957279582795927960279612796227963279642796527966279672796827969279702797127972279732797427975279762797727978279792798027981279822798327984279852798627987279882798927990279912799227993279942799527996279972799827999280002800128002280032800428005280062800728008280092801028011280122801328014280152801628017280182801928020280212802228023280242802528026280272802828029280302803128032280332803428035280362803728038280392804028041280422804328044280452804628047280482804928050280512805228053280542805528056280572805828059280602806128062280632806428065280662806728068280692807028071280722807328074280752807628077280782807928080280812808228083 |
- {
- "_meta": {
- "built_by": "矿脉C 会话 2026-09-02 (subagent, repo-only)",
- "purpose": "把 param_dict 阈值与 status_codes 触发条件对接: 回答\"该阈值有没有真的接到一条码/该码在10min层可不可测/自动还是手动复位\"",
- "source": [
- "status_codes.json",
- "param_dict.json"
- ],
- "method": "正则 PAR_[A-Za-z0-9_]+ 扫 trigger_en/trigger_cn/reset_en/reset_cn/set_delay/repeat_n/repeat_period/powerup_delay; 过程变量粒度取 trigger 里 gr* 后缀",
- "evidence_tier": {
- "A_cross_system": "RTW控制律与PLC PAR_ 两套独立体系给同一数值 (最强, 需人工标注, 见 cross_system_hits)",
- "B_golden_tuned": "golden_kk_2014_12 ≠ default = **字面不同(已撤回'=实调=真实机值'的解读, 见 param_dict.meta.SELF_CORRECTION)**; 差异更可能是跨18个月版本增量",
- "B_golden_only": "仅存在于 Golden 模板 (无 default 可比, 但属实调包)",
- "C_partial": "列间有差异但 golden==default",
- "D_template_default": "五列全同 = 模板从未被调过 = 最弱证据, 禁作独立锚",
- "X_param_not_in_dict": "码引用了字典里没有的 PAR (字典不全)"
- },
- "counts": {
- "codes_total": 1295,
- "codes_with_par_ref": 211,
- "params_referenced": 215,
- "params_referenced_unknown": 36,
- "params_never_referenced": 701,
- "params_total": 880
- },
- "caveat": "SC-1=EN136 4MW海上鼠笼; 我方远景场多为1.5-2.2MW陆上DFIG。阈值数值禁直接外推(见 README 可迁性表), 本表用途是\"结构与接线\"而非\"数值\"",
- "provenance": {
- "kind": "OEM 调试包解析产物 (生成器/模板层), **非整机回读**",
- "evidence_grade": "**模板值** — 按三级标签(实机回读/模板值·生效/模板值·空置), 本包**无一条够得上'实机回读'**",
- "not": "不是任何一台机的实际设定; '一致/闭环/自洽'指模板与模板 或 模板与实测数据 之间的一致, **不代表某台机的实际值**",
- "usage": "证据强度=模板值 × 用途: 作**分组依据/设计意图**合格; 作**阈值锚不合格**",
- "see": "README '证据规矩' 节 + param_dict.json meta.SELF_CORRECTION_2026_09_02",
- "stamped": "2026-09-02 结构污染审计补标"
- }
- },
- "param_code_xref": {
- "PAR_UnfilHydraulicLoad": {
- "codes": [
- "02_09_024"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_WCSInletPreHigh1": {
- "codes": [
- "02_08_123",
- "02_08_126",
- "03_05_048",
- "03_05_051"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_WCSInletPreHigh2": {
- "codes": [
- "02_08_122",
- "02_08_125",
- "03_05_047",
- "03_05_049",
- "03_05_058"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_WCSInletPreLow1": {
- "codes": [
- "02_08_127",
- "03_05_052"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_WCSInletPreLow2": {
- "codes": [
- "02_08_128",
- "03_05_053"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_WCSInletTempLow": {
- "codes": [
- "02_08_131",
- "03_05_056"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_WCSOutletPreLow1": {
- "codes": [
- "02_08_129",
- "03_05_054"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_WCSOutletPreLow2": {
- "codes": [
- "02_08_130",
- "03_05_055"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_YawMotorProtectionReverse": {
- "codes": [
- "02_02_046"
- ],
- "in_param_dict": true,
- "cn": "偏航电机热保护触发电平",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "FALSE",
- "value_sc1_4mw": "0",
- "value_sc1_4mw_b": "False",
- "golden_kk_2014_12": "0",
- "value_xuyi_legacy_other_model": "1"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_bActivatePitchAndTorqueExternal": {
- "codes": [
- "03_06_032"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_bAsymControlEn": {
- "codes": [
- "01_05_072",
- "01_05_073"
- ],
- "in_param_dict": true,
- "cn": "不对称变桨功能使能",
- "unit": "1",
- "subsystem": "CoreController",
- "values": {
- "default": "FALSE",
- "value_sc1_4mw": "0",
- "value_sc1_4mw_b": "0",
- "golden_kk_2014_12": "0",
- "value_xuyi_legacy_other_model": "0"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_bAutoGreaseEnable": {
- "codes": [
- "02_10_109"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_bAutoGreaseError": {
- "codes": [
- "02_10_106",
- "02_10_110"
- ],
- "in_param_dict": true,
- "cn": "偏航自润滑报警电位",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "FALSE",
- "value_sc1_4mw": "False",
- "value_sc1_4mw_b": "False",
- "golden_kk_2014_12": "1",
- "value_xuyi_legacy_other_model": "1"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_bTowerDoorSwitchSignal": {
- "codes": [
- "03_07_010"
- ],
- "in_param_dict": true,
- "cn": "是否有塔筒门信号监测",
- "unit": "1",
- "subsystem": "Cabinet",
- "values": {
- "default": "False",
- "value_sc1_4mw": "False",
- "value_sc1_4mw_b": "False",
- "golden_kk_2014_12": "0",
- "value_xuyi_legacy_other_model": "0"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_bTowerResonanceMode": {
- "codes": [
- "03_09_114"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_bUPSAlarmSignal": {
- "codes": [
- "03_02_002"
- ],
- "in_param_dict": true,
- "cn": "GEN系列变频器UPS报警信号电平",
- "unit": "1",
- "subsystem": "Cabinet",
- "values": {
- "default": "False",
- "value_sc1_4mw": "False",
- "value_sc1_4mw_b": "False",
- "golden_kk_2014_12": "1",
- "value_xuyi_legacy_other_model": "1"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_iMaxNumberOfTraceLogs": {
- "codes": [
- "03_06_020"
- ],
- "in_param_dict": true,
- "cn": "Tracelog存储个数限制",
- "unit": "",
- "subsystem": "LogSystem",
- "values": {
- "default": "1000",
- "value_sc1_4mw": "1000",
- "value_sc1_4mw_b": "1000",
- "golden_kk_2014_12": "1000",
- "value_xuyi_legacy_other_model": "1000"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_iNumberMaxPitchComError": {
- "codes": [
- "04_02_036"
- ],
- "in_param_dict": true,
- "cn": "变桨通讯报警频繁次数上限",
- "unit": "",
- "subsystem": "Pitchsystem",
- "values": {
- "default": "3",
- "value_sc1_4mw": "3",
- "value_sc1_4mw_b": "3",
- "golden_kk_2014_12": "3",
- "value_xuyi_legacy_other_model": ""
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_iNumberMaxStartHydPump": {
- "codes": [
- "02_09_021"
- ],
- "in_param_dict": true,
- "cn": "液压泵开启频繁次数上限",
- "unit": "",
- "subsystem": "HSBrakeSystem",
- "values": {
- "default": "10",
- "value_sc1_4mw": "10",
- "value_sc1_4mw_b": "10",
- "golden_kk_2014_12": "10",
- "value_xuyi_legacy_other_model": "10"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rAccelLimit1ForeaftDirection": {
- "codes": [
- "02_04_021"
- ],
- "in_param_dict": true,
- "cn": "前后方向震动阈值Level1",
- "unit": "无",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "1",
- "value_sc1_4mw": "1",
- "value_sc1_4mw_b": "1",
- "golden_kk_2014_12": "1",
- "value_xuyi_legacy_other_model": "1"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rAccelLimit1OmniDirection": {
- "codes": [
- "02_04_018",
- "02_04_019"
- ],
- "in_param_dict": true,
- "cn": "左右方向震动阈值Level1",
- "unit": "无",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "1.2",
- "value_sc1_4mw": "1.2",
- "value_sc1_4mw_b": "1.2",
- "golden_kk_2014_12": "1.2",
- "value_xuyi_legacy_other_model": "1.2"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rAccelLimit2ForeaftDirection": {
- "codes": [
- "02_04_022"
- ],
- "in_param_dict": true,
- "cn": "前后方向震动阈值Level2",
- "unit": "无",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "1.2",
- "value_sc1_4mw": "1.2",
- "value_sc1_4mw_b": "1.2",
- "golden_kk_2014_12": "1.2",
- "value_xuyi_legacy_other_model": "1.2"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rBladeZeroPositionInsideOffsetAlarm": {
- "codes": [
- "04_02_140",
- "04_02_141",
- "04_02_142"
- ],
- "in_param_dict": true,
- "cn": "零位传感器范围向内侧偏移故障值",
- "unit": "°",
- "subsystem": "Pitchsystem",
- "values": {
- "default": "1",
- "value_sc1_4mw": "",
- "value_sc1_4mw_b": "1",
- "golden_kk_2014_12": "1",
- "value_xuyi_legacy_other_model": ""
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rBladeZeroPositionOutsideOffsetAlarm": {
- "codes": [
- "04_02_140",
- "04_02_141",
- "04_02_142"
- ],
- "in_param_dict": true,
- "cn": "零位传感器范围向外侧偏移故障值",
- "unit": "°",
- "subsystem": "Pitchsystem",
- "values": {
- "default": "1",
- "value_sc1_4mw": "",
- "value_sc1_4mw_b": "1",
- "golden_kk_2014_12": "1",
- "value_xuyi_legacy_other_model": ""
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rCVT_IGBT_TempHigh": {
- "codes": [
- "04_12_023"
- ],
- "in_param_dict": true,
- "cn": "IGBT温度高(不停机)",
- "unit": "摄氏度",
- "subsystem": "ConverterContainer",
- "values": {
- "default": "120",
- "value_sc1_4mw": "",
- "value_sc1_4mw_b": "120",
- "golden_kk_2014_12": "120",
- "value_xuyi_legacy_other_model": ""
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rCVT_IGBT_TempVeryHigh": {
- "codes": [
- "04_12_024"
- ],
- "in_param_dict": true,
- "cn": "IGBT温度太高(太高)",
- "unit": "摄氏度",
- "subsystem": "ConverterContainer",
- "values": {
- "default": "130",
- "value_sc1_4mw": "",
- "value_sc1_4mw_b": "130",
- "golden_kk_2014_12": "130",
- "value_xuyi_legacy_other_model": ""
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rCVT_IGBT_TempVeryHighOR": {
- "codes": [
- "04_12_024"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rDiffForSetValuePitchReached": {
- "codes": [
- "03_06_135",
- "03_09_011"
- ],
- "in_param_dict": true,
- "cn": "桨角控制到位偏差容忍值",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "0.2",
- "value_sc1_4mw": "0.2",
- "value_sc1_4mw_b": "0.2",
- "golden_kk_2014_12": "0.2",
- "value_xuyi_legacy_other_model": "0.2"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rEndpositionPitchZeroDegrees": {
- "codes": [
- "03_09_110"
- ],
- "in_param_dict": true,
- "cn": "风机finepitch角度",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "-0.25",
- "value_sc1_4mw": "0",
- "value_sc1_4mw_b": "0",
- "golden_kk_2014_12": "-5",
- "value_xuyi_legacy_other_model": "-0.4"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rGearOilPressure_MAX": {
- "codes": [
- "02_05_008"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱压力报警上限",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "20",
- "value_sc1_4mw": "12",
- "value_sc1_4mw_b": "12",
- "golden_kk_2014_12": "10",
- "value_xuyi_legacy_other_model": "16"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rGearboxRatio": {
- "codes": [
- "02_04_001",
- "02_04_009",
- "02_04_010"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱变比",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "119.752",
- "value_sc1_4mw": "119.752",
- "value_sc1_4mw_b": "119.752",
- "golden_kk_2014_12": "119.752",
- "value_xuyi_legacy_other_model": "106"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rGenOverSpeedLevel1": {
- "codes": [
- "02_04_001",
- "02_04_003"
- ],
- "in_param_dict": true,
- "cn": "发电机一级过速阈值",
- "unit": "",
- "subsystem": "Drivetrain",
- "values": {
- "default": "1705",
- "value_sc1_4mw": "1705",
- "value_sc1_4mw_b": "1705",
- "golden_kk_2014_12": "1705",
- "value_xuyi_legacy_other_model": "1980"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rGenOverSpeedLevel2": {
- "codes": [
- "02_04_004"
- ],
- "in_param_dict": true,
- "cn": "发电机2级过速阈值",
- "unit": "rpm",
- "subsystem": "SafetySystem",
- "values": {
- "default": "1860",
- "value_sc1_4mw": "1860",
- "value_sc1_4mw_b": "1860",
- "golden_kk_2014_12": "1860",
- "value_xuyi_legacy_other_model": "2250"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rGenSpeedDiffCompareRotGen_RPM": {
- "codes": [
- "02_04_006",
- "02_04_039"
- ],
- "in_param_dict": true,
- "cn": "低速端高低速偏差最大差异阈值",
- "unit": "",
- "subsystem": "Drivetrain",
- "values": {
- "default": "20",
- "value_sc1_4mw": "20",
- "value_sc1_4mw_b": "20",
- "golden_kk_2014_12": "20",
- "value_xuyi_legacy_other_model": "20"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rGenSpeedDiffCompareRotGen_RPM_HIGH": {
- "codes": [
- "02_04_006",
- "02_04_039"
- ],
- "in_param_dict": true,
- "cn": "高速端高低速偏差最大差异阈值",
- "unit": "",
- "subsystem": "Drivetrain",
- "values": {
- "default": "15",
- "value_sc1_4mw": "15",
- "value_sc1_4mw_b": "15",
- "golden_kk_2014_12": "15",
- "value_xuyi_legacy_other_model": "15"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rGenSpeedLimitToAutoGrease": {
- "codes": [
- "02_10_109"
- ],
- "in_param_dict": true,
- "cn": "允许偏航自润滑最高发电机转速",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "200",
- "value_sc1_4mw": "200",
- "value_sc1_4mw_b": "200",
- "golden_kk_2014_12": "200",
- "value_xuyi_legacy_other_model": "200"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rGenSpeedSetValueBrakeModeVanePos": {
- "codes": [
- "03_06_135"
- ],
- "in_param_dict": true,
- "cn": "刹车时最高发电机转速",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "500",
- "value_sc1_4mw": "500",
- "value_sc1_4mw_b": "500",
- "golden_kk_2014_12": "500",
- "value_xuyi_legacy_other_model": "500"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rGenSpeedSetValueBrakeModeVanePos_x000D_": {
- "codes": [
- "03_09_011",
- "03_09_012"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rGenSpeedSlipLimit_MIN": {
- "codes": [
- "02_04_102",
- "02_08_001",
- "02_08_002"
- ],
- "in_param_dict": true,
- "cn": "正常运行时发电机最小转速,低于此转速进入Trundle模式",
- "unit": "",
- "subsystem": "Drivetrain",
- "values": {
- "default": "1065",
- "value_sc1_4mw": "450",
- "value_sc1_4mw_b": "450",
- "golden_kk_2014_12": "720",
- "value_xuyi_legacy_other_model": "1065"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rGenSpeedStartCompareRotGen": {
- "codes": [
- "02_04_006",
- "02_04_009",
- "02_04_010",
- "02_04_039"
- ],
- "in_param_dict": true,
- "cn": "开始监测速度不匹配故障发电机转速",
- "unit": "",
- "subsystem": "Drivetrain",
- "values": {
- "default": "350",
- "value_sc1_4mw": "350",
- "value_sc1_4mw_b": "350",
- "golden_kk_2014_12": "350",
- "value_xuyi_legacy_other_model": "350"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rGenSpeedStartDetectDirection": {
- "codes": [
- "02_04_007"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rGenSpeedStopDetectDirection": {
- "codes": [
- "02_04_007"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rGenSpeedUnequalDefectingHighSpeed": {
- "codes": [
- "02_04_006",
- "02_04_039"
- ],
- "in_param_dict": true,
- "cn": "高低速偏差检测分界线",
- "unit": "",
- "subsystem": "Drivetrain",
- "values": {
- "default": "700",
- "value_sc1_4mw": "700",
- "value_sc1_4mw_b": "700",
- "golden_kk_2014_12": "700",
- "value_xuyi_legacy_other_model": "700"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rGridFrequencyMAX_Hz": {
- "codes": [
- "03_04_010",
- "03_04_020"
- ],
- "in_param_dict": true,
- "cn": "电网频率过高Level2",
- "unit": "Hz",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "52",
- "value_sc1_4mw": "51",
- "value_sc1_4mw_b": "51",
- "golden_kk_2014_12": "51.5",
- "value_xuyi_legacy_other_model": "51"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rGridFrequencyMIN_Hz": {
- "codes": [
- "03_04_011",
- "03_04_021"
- ],
- "in_param_dict": true,
- "cn": "电网频率过低Level2",
- "unit": "Hz",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "47.5",
- "value_sc1_4mw": "48.5",
- "value_sc1_4mw_b": "48.5",
- "golden_kk_2014_12": "47.5",
- "value_xuyi_legacy_other_model": "48"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rGridVoltageMAX_percent": {
- "codes": [
- "03_04_002",
- "03_04_003",
- "03_04_004"
- ],
- "in_param_dict": true,
- "cn": "电网电压过高百分比",
- "unit": "无",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "10",
- "value_sc1_4mw": "10",
- "value_sc1_4mw_b": "10",
- "golden_kk_2014_12": "10",
- "value_xuyi_legacy_other_model": "10"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rGridVoltageMIN_percent": {
- "codes": [
- "03_04_006",
- "03_04_007",
- "03_04_008"
- ],
- "in_param_dict": true,
- "cn": "电网电压过低百分比",
- "unit": "无",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "10",
- "value_sc1_4mw": "10",
- "value_sc1_4mw_b": "10",
- "golden_kk_2014_12": "11",
- "value_xuyi_legacy_other_model": "10"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rHVRTVolLevel0Multiplier": {
- "codes": [
- "03_04_022"
- ],
- "in_param_dict": true,
- "cn": "高电压穿越Level1",
- "unit": "",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "1.1",
- "value_sc1_4mw": "1.1",
- "value_sc1_4mw_b": "1.1",
- "golden_kk_2014_12": "1.11",
- "value_xuyi_legacy_other_model": "1.1"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rHydSystemPressMAX_STOP": {
- "codes": [
- "02_09_005"
- ],
- "in_param_dict": true,
- "cn": "预充压力报警上限",
- "unit": "",
- "subsystem": "HSBrakeSystem",
- "values": {
- "default": "65",
- "value_sc1_4mw": "250",
- "value_sc1_4mw_b": "250",
- "golden_kk_2014_12": "210",
- "value_xuyi_legacy_other_model": "100"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rHydSystemPressMIN_STOP": {
- "codes": [
- "02_09_003"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rHydSystemPressMIN_Warn": {
- "codes": [
- "02_09_001"
- ],
- "in_param_dict": true,
- "cn": "预充压力警告下限",
- "unit": "",
- "subsystem": "HSBrakeSystem",
- "values": {
- "default": "50",
- "value_sc1_4mw": "80",
- "value_sc1_4mw_b": "80",
- "golden_kk_2014_12": "50",
- "value_xuyi_legacy_other_model": "50"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rHydSystemPressMainCircuitMIN_STOP": {
- "codes": [
- "02_09_007"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rHydSystemPressMainCircuitMIN_Warn": {
- "codes": [
- "02_09_006"
- ],
- "in_param_dict": true,
- "cn": "主回路压力报警下限",
- "unit": "",
- "subsystem": "HSBrakeSystem",
- "values": {
- "default": "140",
- "value_sc1_4mw": "140",
- "value_sc1_4mw_b": "140",
- "golden_kk_2014_12": "0",
- "value_xuyi_legacy_other_model": "140"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxCurrentDiff_A": {
- "codes": [
- "03_04_200"
- ],
- "in_param_dict": true,
- "cn": "三相电流最大差异",
- "unit": "A",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "200",
- "value_sc1_4mw": "200",
- "value_sc1_4mw_b": "200",
- "golden_kk_2014_12": "300",
- "value_xuyi_legacy_other_model": "200"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxDeviation_WindDirection": {
- "codes": [
- "04_09_008"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rMaxDeviation_WindSpeed": {
- "codes": [
- "04_09_009"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rMaxDiffSensorsBladeAngle_PitchLimit1": {
- "codes": [
- "01_05_072",
- "01_05_073"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rMaxDiffSensorsBladeAngle_PitchLimit2": {
- "codes": [
- "01_05_073"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rMaxDiffSensorsBladeAngle_PitchLimit5": {
- "codes": [
- "01_05_001",
- "01_05_021",
- "01_05_041"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rMaxGenSpeedAtManualOperation": {
- "codes": [
- "03_09_009"
- ],
- "in_param_dict": true,
- "cn": "风机在维护模式最高发电机转速设定",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "1500",
- "value_sc1_4mw": "1500",
- "value_sc1_4mw_b": "1500",
- "golden_kk_2014_12": "800",
- "value_xuyi_legacy_other_model": "1500"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxPower10min": {
- "codes": [
- "02_08_001"
- ],
- "in_param_dict": true,
- "cn": "10min平均功率最大值",
- "unit": "KW",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "4000",
- "value_sc1_4mw": "4050",
- "value_sc1_4mw_b": "4050",
- "golden_kk_2014_12": "4300",
- "value_xuyi_legacy_other_model": "1600"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxPower1sec": {
- "codes": [
- "02_08_003"
- ],
- "in_param_dict": true,
- "cn": "1sec平均功率最大值",
- "unit": "KW",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "4000",
- "value_sc1_4mw": "4600",
- "value_sc1_4mw_b": "4600",
- "golden_kk_2014_12": "4850",
- "value_xuyi_legacy_other_model": "1780"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxPower30sec": {
- "codes": [
- "02_08_002"
- ],
- "in_param_dict": true,
- "cn": "30sec平均功率最大值",
- "unit": "KW",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "4000",
- "value_sc1_4mw": "4400",
- "value_sc1_4mw_b": "4400",
- "golden_kk_2014_12": "4650",
- "value_xuyi_legacy_other_model": "1600"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxPowerDiff100ms": {
- "codes": [
- "02_08_009"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rMaxPowerDiff100ms_x000D_": {
- "codes": [
- "02_08_009"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rMaxRecoverWindSpeed_10min": {
- "codes": [
- "02_11_103"
- ],
- "in_param_dict": true,
- "cn": "10分钟风速过大停机状态字消失的10分钟平均风速阈值",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "20",
- "value_sc1_4mw": "22",
- "value_sc1_4mw_b": "22",
- "golden_kk_2014_12": "22",
- "value_xuyi_legacy_other_model": "18"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxRecoverWindSpeed_1sec": {
- "codes": [
- "02_11_101"
- ],
- "in_param_dict": true,
- "cn": "1秒钟风速过大停机状态字消失的1秒钟平均风速阈值",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "25",
- "value_sc1_4mw": "16",
- "value_sc1_4mw_b": "16",
- "golden_kk_2014_12": "16",
- "value_xuyi_legacy_other_model": "15"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxRecoverWindSpeed_30sec": {
- "codes": [
- "02_11_102"
- ],
- "in_param_dict": true,
- "cn": "30秒风速过大停机状态字消失的30秒平均风速阈值",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "23",
- "value_sc1_4mw": "19",
- "value_sc1_4mw_b": "19",
- "golden_kk_2014_12": "19",
- "value_xuyi_legacy_other_model": "17"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxWindForManualModeOrService": {
- "codes": [
- "02_11_113"
- ],
- "in_param_dict": true,
- "cn": "运行进入手动模式、维护模式的最大风速",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "15",
- "value_sc1_4mw": "12",
- "value_sc1_4mw_b": "12",
- "golden_kk_2014_12": "12",
- "value_xuyi_legacy_other_model": "12"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxWindSpeed_10min": {
- "codes": [
- "02_11_103"
- ],
- "in_param_dict": true,
- "cn": "10分钟风速过大停机状态字触发的10分钟平均风速阈值",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "25",
- "value_sc1_4mw": "24",
- "value_sc1_4mw_b": "24",
- "golden_kk_2014_12": "24",
- "value_xuyi_legacy_other_model": "20"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxWindSpeed_1sec": {
- "codes": [
- "02_11_101"
- ],
- "in_param_dict": true,
- "cn": "1秒钟风速过大停机状态字触发的1秒钟平均风速阈值",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "30",
- "value_sc1_4mw": "30",
- "value_sc1_4mw_b": "30",
- "golden_kk_2014_12": "30",
- "value_xuyi_legacy_other_model": "25"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rMaxWindSpeed_30sec": {
- "codes": [
- "02_11_102"
- ],
- "in_param_dict": true,
- "cn": "30秒风速过大停机状态字触发的30秒平均风速阈值",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "28",
- "value_sc1_4mw": "27",
- "value_sc1_4mw_b": "27",
- "golden_kk_2014_12": "27",
- "value_xuyi_legacy_other_model": "23"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMaxWindUntwistCable": {
- "codes": [
- "02_11_112"
- ],
- "in_param_dict": true,
- "cn": "允许偏航解缆最高风速",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "34",
- "value_sc1_4mw": "25",
- "value_sc1_4mw_b": "25",
- "golden_kk_2014_12": "25",
- "value_xuyi_legacy_other_model": "25"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rMinRecoverWindSpeed_10min": {
- "codes": [
- "02_11_109"
- ],
- "in_param_dict": true,
- "cn": "10分钟平均风速过小状态字消失的10分钟平均风速阈值",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "3.8",
- "value_sc1_4mw": "3.8",
- "value_sc1_4mw_b": "3.8",
- "golden_kk_2014_12": "3.8",
- "value_xuyi_legacy_other_model": "3.2"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rMinWindSpeed_10min": {
- "codes": [
- "02_11_109"
- ],
- "in_param_dict": true,
- "cn": "10分钟平均风速过小状态字触发的10分钟平均风速阈值",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "2.8",
- "value_sc1_4mw": "3.3",
- "value_sc1_4mw_b": "3.3",
- "golden_kk_2014_12": "3.3",
- "value_xuyi_legacy_other_model": "2.9000001"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rNominalVoltage_Level_690V": {
- "codes": [
- "03_04_002",
- "03_04_003",
- "03_04_004",
- "03_04_006",
- "03_04_007",
- "03_04_008",
- "03_04_022"
- ],
- "in_param_dict": true,
- "cn": "额定电网电压",
- "unit": "V",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "690",
- "value_sc1_4mw": "690",
- "value_sc1_4mw_b": "690",
- "golden_kk_2014_12": "690",
- "value_xuyi_legacy_other_model": "690"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rPitchAngleSetValueVanePosition": {
- "codes": [
- "01_05_072",
- "01_05_073",
- "03_06_135",
- "03_09_011"
- ],
- "in_param_dict": true,
- "cn": "风机Vane桨叶角度设定",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "89",
- "value_sc1_4mw": "89",
- "value_sc1_4mw_b": "89",
- "golden_kk_2014_12": "89",
- "value_xuyi_legacy_other_model": "89"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rPitchMoveLimit": {
- "codes": [
- "03_09_110"
- ],
- "in_param_dict": true,
- "cn": "进入桨叶自润滑,桨叶角度范围",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "15",
- "value_sc1_4mw": "15",
- "value_sc1_4mw_b": "15",
- "golden_kk_2014_12": "6",
- "value_xuyi_legacy_other_model": "15"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rPower100msDiffMax": {
- "codes": [
- "02_08_009"
- ],
- "in_param_dict": true,
- "cn": "外部设备、变频器测得功率允许的最大差异",
- "unit": "KW",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "150",
- "value_sc1_4mw": "150",
- "value_sc1_4mw_b": "150",
- "golden_kk_2014_12": "350",
- "value_xuyi_legacy_other_model": "150"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rPowerAboveUntwistCablePreSTOP": {
- "codes": [
- "02_10_102"
- ],
- "in_param_dict": true,
- "cn": "允许偏航预解缆的最高发电机功率",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "400",
- "value_sc1_4mw": "400",
- "value_sc1_4mw_b": "400",
- "golden_kk_2014_12": "400",
- "value_xuyi_legacy_other_model": "400"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rPre_CS_LowError": {
- "codes": [
- "04_08_015"
- ],
- "in_param_dict": true,
- "cn": "冷却系统压力过低故障",
- "unit": "Bar",
- "subsystem": "CoolingSystem",
- "values": {
- "default": "0.1",
- "value_sc1_4mw": "0.1",
- "value_sc1_4mw_b": "0.1",
- "golden_kk_2014_12": "0.2",
- "value_xuyi_legacy_other_model": "0.1"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rPre_CS_LowWarning": {
- "codes": [
- "04_08_014"
- ],
- "in_param_dict": true,
- "cn": "冷却系统压力过低报警",
- "unit": "Bar",
- "subsystem": "CoolingSystem",
- "values": {
- "default": "1",
- "value_sc1_4mw": "1",
- "value_sc1_4mw_b": "1",
- "golden_kk_2014_12": "0.4",
- "value_xuyi_legacy_other_model": "1"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rPressHysteresisLower": {
- "codes": [
- "02_09_020"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rPressHysteresisUpper": {
- "codes": [
- "02_09_019"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rPressToReleaseYawMotor_MAX": {
- "codes": [
- "02_09_020"
- ],
- "in_param_dict": true,
- "cn": "偏航动作期间主回路压力",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "20",
- "value_sc1_4mw": "20",
- "value_sc1_4mw_b": "20",
- "golden_kk_2014_12": "17",
- "value_xuyi_legacy_other_model": "20"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rPressToReleaseYawMotor_MIN": {
- "codes": [
- "02_09_019"
- ],
- "in_param_dict": true,
- "cn": "泄压动作最高主回路压力",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "0",
- "value_sc1_4mw": "0",
- "value_sc1_4mw_b": "0",
- "golden_kk_2014_12": "0",
- "value_xuyi_legacy_other_model": "0"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rRotorLockPushOutPressureLowError": {
- "codes": [
- "04_03_006"
- ],
- "in_param_dict": true,
- "cn": "风轮锁销子退出压力过低故障阈值",
- "unit": "Bar",
- "subsystem": "RotorLock",
- "values": {
- "default": "5",
- "value_sc1_4mw": "5",
- "value_sc1_4mw_b": "5",
- "golden_kk_2014_12": "5",
- "value_xuyi_legacy_other_model": "5"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rRotorLockPushOutPressureLowWarning": {
- "codes": [
- "04_03_005"
- ],
- "in_param_dict": true,
- "cn": "风轮锁销子退出压力过低警告阈值",
- "unit": "Bar",
- "subsystem": "RotorLock",
- "values": {
- "default": "20",
- "value_sc1_4mw": "20",
- "value_sc1_4mw_b": "20",
- "golden_kk_2014_12": "20",
- "value_xuyi_legacy_other_model": "20"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rRotorLockPushOutPressureOK": {
- "codes": [
- "04_03_003"
- ],
- "in_param_dict": true,
- "cn": "风轮锁销子退出压力正常",
- "unit": "Bar",
- "subsystem": "RotorLock",
- "values": {
- "default": "80",
- "value_sc1_4mw": "150",
- "value_sc1_4mw_b": "150",
- "golden_kk_2014_12": "150",
- "value_xuyi_legacy_other_model": "80"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rSSDMax": {
- "codes": [
- "02_01_006",
- "04_01_017"
- ],
- "in_param_dict": true,
- "cn": "检测SSD震动的阈值",
- "unit": "无",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "5",
- "value_sc1_4mw": "5",
- "value_sc1_4mw_b": "5",
- "golden_kk_2014_12": "7",
- "value_xuyi_legacy_other_model": "5"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rShutDownSlowForLowPower": {
- "codes": [
- "03_09_101",
- "03_09_102"
- ],
- "in_param_dict": true,
- "cn": "功率过低停机10min平均功率阈值",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "5",
- "value_sc1_4mw": "5",
- "value_sc1_4mw_b": "5",
- "golden_kk_2014_12": "5",
- "value_xuyi_legacy_other_model": "5"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempGearOilBelowMonitoringFilter": {
- "codes": [
- "02_05_001"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rTempGen_HeaterON": {
- "codes": [
- "02_08_100"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rTempHigh_CabinetNacelle": {
- "codes": [
- "02_02_009",
- "02_02_010"
- ],
- "in_param_dict": true,
- "cn": "机舱控制柜高温报警阈值",
- "unit": "℃",
- "subsystem": "Cabinet",
- "values": {
- "default": "50",
- "value_sc1_4mw": "40",
- "value_sc1_4mw_b": "40",
- "golden_kk_2014_12": "40",
- "value_xuyi_legacy_other_model": "50"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempHigh_CabinetTower": {
- "codes": [
- "03_02_024"
- ],
- "in_param_dict": true,
- "cn": "塔底控制柜高温报警阈值",
- "unit": "℃",
- "subsystem": "Cabinet",
- "values": {
- "default": "50",
- "value_sc1_4mw": "40",
- "value_sc1_4mw_b": "40",
- "golden_kk_2014_12": "40",
- "value_xuyi_legacy_other_model": "50"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempHigh_GearBearingDE": {
- "codes": [
- "02_05_028"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱驱动端温度高",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "85",
- "value_sc1_4mw": "85",
- "value_sc1_4mw_b": "85",
- "golden_kk_2014_12": "90",
- "value_xuyi_legacy_other_model": "85"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempHigh_GearBearingNDE": {
- "codes": [
- "02_05_033",
- "02_05_035"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱非驱动端温度高",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "85",
- "value_sc1_4mw": "85",
- "value_sc1_4mw_b": "85",
- "golden_kk_2014_12": "85",
- "value_xuyi_legacy_other_model": "85"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempHigh_GearOilInlet": {
- "codes": [
- "02_05_019"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱入口温度高",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "70",
- "value_sc1_4mw": "70",
- "value_sc1_4mw_b": "70",
- "golden_kk_2014_12": "70",
- "value_xuyi_legacy_other_model": "0"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rTempHigh_GearOilSump": {
- "codes": [
- "02_05_015",
- "02_05_017"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱油池温度高",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "70",
- "value_sc1_4mw": "70",
- "value_sc1_4mw_b": "70",
- "golden_kk_2014_12": "70",
- "value_xuyi_legacy_other_model": "70"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempHigh_GenBearDE": {
- "codes": [
- "02_08_026",
- "02_08_030"
- ],
- "in_param_dict": true,
- "cn": "发电机驱动端温度高",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "85",
- "value_sc1_4mw": "85",
- "value_sc1_4mw_b": "85",
- "golden_kk_2014_12": "95",
- "value_xuyi_legacy_other_model": "85"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempHigh_GenBearNDE": {
- "codes": [
- "02_08_030"
- ],
- "in_param_dict": true,
- "cn": "发电机非驱动端温度高",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "85",
- "value_sc1_4mw": "75",
- "value_sc1_4mw_b": "75",
- "golden_kk_2014_12": "95",
- "value_xuyi_legacy_other_model": "85"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempHigh_GenCoolingInlet": {
- "codes": [
- "02_08_035"
- ],
- "in_param_dict": true,
- "cn": "发电机冷却入口温度高",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "90",
- "value_sc1_4mw": "90",
- "value_sc1_4mw_b": "90",
- "golden_kk_2014_12": "90",
- "value_xuyi_legacy_other_model": "90"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempHigh_GenCoolingOutlet": {
- "codes": [
- "02_08_035"
- ],
- "in_param_dict": true,
- "cn": "发电机冷却出口温度高",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "125",
- "value_sc1_4mw": "125",
- "value_sc1_4mw_b": "125",
- "golden_kk_2014_12": "125",
- "value_xuyi_legacy_other_model": "125"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempHigh_GenStator": {
- "codes": [
- "02_08_013",
- "02_08_017",
- "02_08_021"
- ],
- "in_param_dict": true,
- "cn": "发电机定子温度高",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "130",
- "value_sc1_4mw": "150",
- "value_sc1_4mw_b": "150",
- "golden_kk_2014_12": "145",
- "value_xuyi_legacy_other_model": "130"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempHigh_Nacelle": {
- "codes": [
- "02_03_001"
- ],
- "in_param_dict": true,
- "cn": "机舱温度过高阈值1",
- "unit": "℃",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "40",
- "value_sc1_4mw": "45",
- "value_sc1_4mw_b": "45",
- "golden_kk_2014_12": "47",
- "value_xuyi_legacy_other_model": "45"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempHigh_Outdoor": {
- "codes": [
- "02_11_016"
- ],
- "in_param_dict": true,
- "cn": "舱外温度过高阈值1",
- "unit": "℃",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "35",
- "value_sc1_4mw": "35",
- "value_sc1_4mw_b": "35",
- "golden_kk_2014_12": "35",
- "value_xuyi_legacy_other_model": "35"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempHigh_RotorBearingA": {
- "codes": [
- "02_04_026"
- ],
- "in_param_dict": true,
- "cn": "主轴轴承温度过高警告",
- "unit": "℃",
- "subsystem": "Drivetrain",
- "values": {
- "default": "55",
- "value_sc1_4mw": "60",
- "value_sc1_4mw_b": "60",
- "golden_kk_2014_12": "60",
- "value_xuyi_legacy_other_model": "55"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempHigh_TowerBase": {
- "codes": [
- "03_03_001"
- ],
- "in_param_dict": true,
- "cn": "塔底高温报警阈值(sc-1在变频器集装箱)",
- "unit": "℃",
- "subsystem": "Cabinet",
- "values": {
- "default": "400",
- "value_sc1_4mw": "40",
- "value_sc1_4mw_b": "40",
- "golden_kk_2014_12": "40",
- "value_xuyi_legacy_other_model": "40"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempHysteresisGenStatorDew": {
- "codes": [
- "02_08_100"
- ],
- "in_param_dict": true,
- "cn": "机舱与发电机定子温差上限",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "5",
- "value_sc1_4mw": "5",
- "value_sc1_4mw_b": "5",
- "golden_kk_2014_12": "10",
- "value_xuyi_legacy_other_model": "2"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempHysteresisLowerTemp": {
- "codes": [
- "02_03_002",
- "02_03_004",
- "02_05_016",
- "02_05_018",
- "02_05_020",
- "02_05_022",
- "02_05_033",
- "02_08_014",
- "02_08_016",
- "02_08_018",
- "02_08_020",
- "02_08_022",
- "02_08_024",
- "02_08_027",
- "02_08_029",
- "02_08_031",
- "02_08_033",
- "02_08_036",
- "02_08_038",
- "02_11_017",
- "02_11_019",
- "03_02_025",
- "03_02_027",
- "03_03_002",
- "03_03_004"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rTempHysteresisUpperTemp": {
- "codes": [
- "02_02_009",
- "02_02_010",
- "02_02_011",
- "02_02_012",
- "02_03_001",
- "02_03_003",
- "02_04_026",
- "02_04_028",
- "02_05_015",
- "02_05_017",
- "02_05_019",
- "02_05_021",
- "02_05_028",
- "02_05_030",
- "02_05_035",
- "02_08_013",
- "02_08_015",
- "02_08_017",
- "02_08_019",
- "02_08_021",
- "02_08_023",
- "02_08_026",
- "02_08_028",
- "02_08_030",
- "02_08_032",
- "02_08_035",
- "02_08_037",
- "02_11_016",
- "02_11_018",
- "03_02_024",
- "03_02_026",
- "03_03_001",
- "03_03_003"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rTempLow_CabinetTower": {
- "codes": [
- "03_02_025"
- ],
- "in_param_dict": true,
- "cn": "塔底控制柜低温报警阈值",
- "unit": "℃",
- "subsystem": "Cabinet",
- "values": {
- "default": "2",
- "value_sc1_4mw": "0",
- "value_sc1_4mw_b": "0",
- "golden_kk_2014_12": "0",
- "value_xuyi_legacy_other_model": "0"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempLow_GearBearingNDE": {
- "codes": [
- "02_05_033"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rTempLow_GearOilInlet": {
- "codes": [
- "02_05_020"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱入口温度低",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "5",
- "value_sc1_4mw": "5",
- "value_sc1_4mw_b": "5",
- "golden_kk_2014_12": "-20",
- "value_xuyi_legacy_other_model": "0"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempLow_GearOilSump": {
- "codes": [
- "02_05_016"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱油池温度低",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "5",
- "value_sc1_4mw": "5",
- "value_sc1_4mw_b": "5",
- "golden_kk_2014_12": "0",
- "value_xuyi_legacy_other_model": "0"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempLow_GenBearDE": {
- "codes": [
- "02_08_027"
- ],
- "in_param_dict": true,
- "cn": "发电机驱动端温度低",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "-25",
- "value_sc1_4mw": "-20",
- "value_sc1_4mw_b": "-20",
- "golden_kk_2014_12": "-15",
- "value_xuyi_legacy_other_model": "-25"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempLow_GenBearNDE": {
- "codes": [
- "02_08_031"
- ],
- "in_param_dict": true,
- "cn": "发电机非驱动端温度低",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "-25",
- "value_sc1_4mw": "-20",
- "value_sc1_4mw_b": "-20",
- "golden_kk_2014_12": "-15",
- "value_xuyi_legacy_other_model": "-25"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempLow_GenCoolingInlet": {
- "codes": [
- "02_08_036"
- ],
- "in_param_dict": true,
- "cn": "发电机冷却入口温度低",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "-222",
- "value_sc1_4mw": "-222",
- "value_sc1_4mw_b": "-222",
- "golden_kk_2014_12": "-222",
- "value_xuyi_legacy_other_model": "-273"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rTempLow_GenCoolingOutlet": {
- "codes": [
- "02_08_036"
- ],
- "in_param_dict": true,
- "cn": "发电机冷却出口温度低",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "-222",
- "value_sc1_4mw": "-222",
- "value_sc1_4mw_b": "-222",
- "golden_kk_2014_12": "-222",
- "value_xuyi_legacy_other_model": "-35"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rTempLow_GenStator": {
- "codes": [
- "02_08_014",
- "02_08_018",
- "02_08_022"
- ],
- "in_param_dict": true,
- "cn": "发电机定子温度低",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "-25",
- "value_sc1_4mw": "-20",
- "value_sc1_4mw_b": "-20",
- "golden_kk_2014_12": "-15",
- "value_xuyi_legacy_other_model": "-25"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempLow_Nacelle": {
- "codes": [
- "02_03_002"
- ],
- "in_param_dict": true,
- "cn": "机舱温度过低阈值1",
- "unit": "℃",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "-5",
- "value_sc1_4mw": "-25",
- "value_sc1_4mw_b": "-25",
- "golden_kk_2014_12": "-25",
- "value_xuyi_legacy_other_model": "-25"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempLow_Outdoor": {
- "codes": [
- "02_11_017"
- ],
- "in_param_dict": true,
- "cn": "舱外温度过低阈值1",
- "unit": "℃",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "-5",
- "value_sc1_4mw": "-15",
- "value_sc1_4mw_b": "-15",
- "golden_kk_2014_12": "-15",
- "value_xuyi_legacy_other_model": "-15"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempLow_TowerBase": {
- "codes": [
- "03_03_002"
- ],
- "in_param_dict": true,
- "cn": "塔底低温报警阈值(sc-1在变频器集装箱)",
- "unit": "℃",
- "subsystem": "Cabinet",
- "values": {
- "default": "-150",
- "value_sc1_4mw": "0",
- "value_sc1_4mw_b": "0",
- "golden_kk_2014_12": "0",
- "value_xuyi_legacy_other_model": "-30"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMAX_CabinetNacelle": {
- "codes": [
- "02_02_011"
- ],
- "in_param_dict": true,
- "cn": "机舱控制柜温度超过设计值",
- "unit": "℃",
- "subsystem": "Cabinet",
- "values": {
- "default": "52",
- "value_sc1_4mw": "50",
- "value_sc1_4mw_b": "50",
- "golden_kk_2014_12": "52",
- "value_xuyi_legacy_other_model": "52"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rTempMAX_CabinetTower": {
- "codes": [
- "03_02_026"
- ],
- "in_param_dict": true,
- "cn": "塔底控制柜温度超过设计值",
- "unit": "℃",
- "subsystem": "Cabinet",
- "values": {
- "default": "52",
- "value_sc1_4mw": "50",
- "value_sc1_4mw_b": "50",
- "golden_kk_2014_12": "52",
- "value_xuyi_legacy_other_model": "52"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rTempMAX_GearBearingDE": {
- "codes": [
- "02_05_030"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱中速段驱动端温度超过设计值",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "90",
- "value_sc1_4mw": "90",
- "value_sc1_4mw_b": "90",
- "golden_kk_2014_12": "75",
- "value_xuyi_legacy_other_model": "90"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMAX_GearBearingNDE": {
- "codes": [
- "02_05_035"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱非驱动端温度超过设计值",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "90",
- "value_sc1_4mw": "90",
- "value_sc1_4mw_b": "90",
- "golden_kk_2014_12": "90",
- "value_xuyi_legacy_other_model": "90"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempMAX_GearOilInlet": {
- "codes": [
- "02_05_021"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱入口温度超过设计值",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "75",
- "value_sc1_4mw": "75",
- "value_sc1_4mw_b": "75",
- "golden_kk_2014_12": "75",
- "value_xuyi_legacy_other_model": "0"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rTempMAX_GearOilSump": {
- "codes": [
- "02_05_017"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱油温高于设计值",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "75",
- "value_sc1_4mw": "75",
- "value_sc1_4mw_b": "75",
- "golden_kk_2014_12": "75",
- "value_xuyi_legacy_other_model": "75"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempMAX_GenBearDE": {
- "codes": [
- "02_08_028"
- ],
- "in_param_dict": true,
- "cn": "发电机驱动端温度太高",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "90",
- "value_sc1_4mw": "90",
- "value_sc1_4mw_b": "90",
- "golden_kk_2014_12": "100",
- "value_xuyi_legacy_other_model": "90"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMAX_GenBearNDE": {
- "codes": [
- "02_08_032"
- ],
- "in_param_dict": true,
- "cn": "发电机非驱动端温度太高",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "90",
- "value_sc1_4mw": "80",
- "value_sc1_4mw_b": "80",
- "golden_kk_2014_12": "100",
- "value_xuyi_legacy_other_model": "90"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMAX_GenCoolingInlet": {
- "codes": [
- "02_08_037"
- ],
- "in_param_dict": true,
- "cn": "发电机冷却入口温度上限",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "95",
- "value_sc1_4mw": "95",
- "value_sc1_4mw_b": "95",
- "golden_kk_2014_12": "95",
- "value_xuyi_legacy_other_model": "95"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempMAX_GenCoolingOutlet": {
- "codes": [
- "02_08_037"
- ],
- "in_param_dict": true,
- "cn": "发电机冷却出口温度上限",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "130",
- "value_sc1_4mw": "130",
- "value_sc1_4mw_b": "130",
- "golden_kk_2014_12": "130",
- "value_xuyi_legacy_other_model": "130"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempMAX_GenStator": {
- "codes": [
- "02_08_015",
- "02_08_019",
- "02_08_023"
- ],
- "in_param_dict": true,
- "cn": "发电机定子温度上限",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "150",
- "value_sc1_4mw": "160",
- "value_sc1_4mw_b": "160",
- "golden_kk_2014_12": "160",
- "value_xuyi_legacy_other_model": "150"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMAX_Nacelle": {
- "codes": [
- "02_03_003"
- ],
- "in_param_dict": true,
- "cn": "机舱温度过高阈值2",
- "unit": "℃",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "48",
- "value_sc1_4mw": "48",
- "value_sc1_4mw_b": "48",
- "golden_kk_2014_12": "50",
- "value_xuyi_legacy_other_model": "48"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMAX_Outdoor": {
- "codes": [
- "02_11_018"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rTempMAX_RotorBearingA": {
- "codes": [
- "02_04_028"
- ],
- "in_param_dict": true,
- "cn": "主轴轴承温度太高故障",
- "unit": "℃",
- "subsystem": "Drivetrain",
- "values": {
- "default": "60",
- "value_sc1_4mw": "70",
- "value_sc1_4mw_b": "70",
- "golden_kk_2014_12": "70",
- "value_xuyi_legacy_other_model": "60"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMAX_TowerBase": {
- "codes": [
- "03_03_003"
- ],
- "in_param_dict": true,
- "cn": "塔底温度超过设计值(sc-1在变频器集装箱)",
- "unit": "℃",
- "subsystem": "Cabinet",
- "values": {
- "default": "450",
- "value_sc1_4mw": "45",
- "value_sc1_4mw_b": "45",
- "golden_kk_2014_12": "45",
- "value_xuyi_legacy_other_model": "45"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMIN_CabinetNacelle": {
- "codes": [
- "02_02_012",
- "03_02_109"
- ],
- "in_param_dict": true,
- "cn": "机舱控制柜温度低于设计值",
- "unit": "℃",
- "subsystem": "Cabinet",
- "values": {
- "default": "-5",
- "value_sc1_4mw": "-20",
- "value_sc1_4mw_b": "-20",
- "golden_kk_2014_12": "-5",
- "value_xuyi_legacy_other_model": "-5"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rTempMIN_CabinetTower": {
- "codes": [
- "03_02_027",
- "03_02_109"
- ],
- "in_param_dict": true,
- "cn": "塔底控制柜温度低于设计值",
- "unit": "℃",
- "subsystem": "Cabinet",
- "values": {
- "default": "0",
- "value_sc1_4mw": "-20",
- "value_sc1_4mw_b": "-20",
- "golden_kk_2014_12": "-3",
- "value_xuyi_legacy_other_model": "-3"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMIN_GearBearingDE": {
- "codes": [
- "02_05_033"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rTempMIN_GearOilInlet": {
- "codes": [
- "02_05_022"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱入口温度低于设计值",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "-20",
- "value_sc1_4mw": "-20",
- "value_sc1_4mw_b": "-20",
- "golden_kk_2014_12": "-25",
- "value_xuyi_legacy_other_model": "0"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMIN_GearOilSump": {
- "codes": [
- "02_05_018"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱温度低于设计值",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "5",
- "value_sc1_4mw": "-20",
- "value_sc1_4mw_b": "-20",
- "golden_kk_2014_12": "-25",
- "value_xuyi_legacy_other_model": "-5"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMIN_GenBearDE": {
- "codes": [
- "02_08_029"
- ],
- "in_param_dict": true,
- "cn": "发电机驱动端温度太低",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "-30",
- "value_sc1_4mw": "-20",
- "value_sc1_4mw_b": "-20",
- "golden_kk_2014_12": "-20",
- "value_xuyi_legacy_other_model": "-30"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMIN_GenBearNDE": {
- "codes": [
- "02_08_033"
- ],
- "in_param_dict": true,
- "cn": "发电机非驱动端温度太低",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "-30",
- "value_sc1_4mw": "-20",
- "value_sc1_4mw_b": "-20",
- "golden_kk_2014_12": "-20",
- "value_xuyi_legacy_other_model": "-30"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMIN_GenCoolingInlet": {
- "codes": [
- "02_08_038"
- ],
- "in_param_dict": true,
- "cn": "发电机冷却入口温度下限",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "-222",
- "value_sc1_4mw": "-222",
- "value_sc1_4mw_b": "-222",
- "golden_kk_2014_12": "-222",
- "value_xuyi_legacy_other_model": "-273"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rTempMIN_GenCoolingOutlet": {
- "codes": [
- "02_08_038"
- ],
- "in_param_dict": true,
- "cn": "发电机冷却出口温度下限",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "-222",
- "value_sc1_4mw": "-222",
- "value_sc1_4mw_b": "-222",
- "golden_kk_2014_12": "-222",
- "value_xuyi_legacy_other_model": "-40"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rTempMIN_GenStator": {
- "codes": [
- "02_08_016",
- "02_08_020",
- "02_08_024"
- ],
- "in_param_dict": true,
- "cn": "发电机定子温度下限",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "-30",
- "value_sc1_4mw": "-30",
- "value_sc1_4mw_b": "-30",
- "golden_kk_2014_12": "-20",
- "value_xuyi_legacy_other_model": "-30"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMIN_Nacelle": {
- "codes": [
- "02_03_004"
- ],
- "in_param_dict": true,
- "cn": "机舱温度过低阈值2",
- "unit": "℃",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "-10",
- "value_sc1_4mw": "-30",
- "value_sc1_4mw_b": "-30",
- "golden_kk_2014_12": "-30",
- "value_xuyi_legacy_other_model": "-30"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTempMIN_Outdoor": {
- "codes": [
- "02_11_019"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rTempMIN_TowerBase": {
- "codes": [
- "03_03_004"
- ],
- "in_param_dict": true,
- "cn": "塔底温度低于设计值(sc-1在变频器集装箱)",
- "unit": "℃",
- "subsystem": "Cabinet",
- "values": {
- "default": "-200",
- "value_sc1_4mw": "-200",
- "value_sc1_4mw_b": "-200",
- "golden_kk_2014_12": "-200",
- "value_xuyi_legacy_other_model": "-200"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempRearBearingHighError": {
- "codes": [
- "04_04_006"
- ],
- "in_param_dict": true,
- "cn": "SC1-主轴后轴承温度高报警",
- "unit": "℃",
- "subsystem": "Drivetrain",
- "values": {
- "default": "70",
- "value_sc1_4mw": "70",
- "value_sc1_4mw_b": "70",
- "golden_kk_2014_12": "70",
- "value_xuyi_legacy_other_model": "70"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempRearBearingHighWarning": {
- "codes": [
- "04_04_005"
- ],
- "in_param_dict": true,
- "cn": "SC1-主轴后轴承温度高报警",
- "unit": "℃",
- "subsystem": "Drivetrain",
- "values": {
- "default": "60",
- "value_sc1_4mw": "60",
- "value_sc1_4mw_b": "60",
- "golden_kk_2014_12": "60",
- "value_xuyi_legacy_other_model": "60"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTempToDisableOverPower": {
- "codes": [
- "03_03_102"
- ],
- "in_param_dict": true,
- "cn": "电缆温度超过允许最大温度,禁止超发功能",
- "unit": "℃",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "80",
- "value_sc1_4mw": "80",
- "value_sc1_4mw_b": "80",
- "golden_kk_2014_12": "80",
- "value_xuyi_legacy_other_model": "80"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTemp_CS_GENOutletHigh": {
- "codes": [
- "04_08_013"
- ],
- "in_param_dict": true,
- "cn": "冷却系统发电机出口水温过高报警",
- "unit": "摄氏度",
- "subsystem": "CoolingSystem",
- "values": {
- "default": "130",
- "value_sc1_4mw": "130",
- "value_sc1_4mw_b": "130",
- "golden_kk_2014_12": "130",
- "value_xuyi_legacy_other_model": "130"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rTowerResoGenSpeedDown": {
- "codes": [
- "03_09_114"
- ],
- "in_param_dict": true,
- "cn": "共振区转速下限",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "600",
- "value_sc1_4mw": "690",
- "value_sc1_4mw_b": "690",
- "golden_kk_2014_12": "690",
- "value_xuyi_legacy_other_model": "650"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rTowerResoGenSpeedUp": {
- "codes": [
- "03_09_114"
- ],
- "in_param_dict": true,
- "cn": "共振区转速上限",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "700",
- "value_sc1_4mw": "760",
- "value_sc1_4mw_b": "760",
- "golden_kk_2014_12": "760",
- "value_xuyi_legacy_other_model": "850"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rVibrationForeaftDirection": {
- "codes": [
- "02_04_025"
- ],
- "in_param_dict": true,
- "cn": "统计震动过大的阈值",
- "unit": "无",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "1.2",
- "value_sc1_4mw": "1.2",
- "value_sc1_4mw_b": "1.2",
- "golden_kk_2014_12": "1.2",
- "value_xuyi_legacy_other_model": "1"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rVibrationOmniDirection": {
- "codes": [
- "02_04_024"
- ],
- "in_param_dict": true,
- "cn": "统计震动过大的阈值",
- "unit": "无",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "1.2",
- "value_sc1_4mw": "1.2",
- "value_sc1_4mw_b": "1.2",
- "golden_kk_2014_12": "1.2",
- "value_xuyi_legacy_other_model": "1.2"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rVoltageForGridLost_Volt": {
- "codes": [
- "03_04_018"
- ],
- "in_param_dict": true,
- "cn": "电网掉电电压阈值",
- "unit": "",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "50",
- "value_sc1_4mw": "50",
- "value_sc1_4mw_b": "50",
- "golden_kk_2014_12": "50",
- "value_xuyi_legacy_other_model": "50"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rWCSGENInletTempHigh2": {
- "codes": [
- "02_08_124"
- ],
- "in_param_dict": true,
- "cn": "发电机高澜水冷入口温度高二级阈值",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "50",
- "value_sc1_4mw": "50",
- "value_sc1_4mw_b": "50",
- "golden_kk_2014_12": "50",
- "value_xuyi_legacy_other_model": "50"
- },
- "five_col_identical": true,
- "golden_differs_from_default": false,
- "evidence_tier": "D_template_default"
- },
- "PAR_rWindAboveActivateYawTracking": {
- "codes": [
- "02_11_105"
- ],
- "in_param_dict": true,
- "cn": "小风禁止自动对风风速",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "2.5",
- "value_sc1_4mw": "2",
- "value_sc1_4mw_b": "2",
- "golden_kk_2014_12": "3",
- "value_xuyi_legacy_other_model": "2"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rWindAboveStart": {
- "codes": [
- "02_11_104"
- ],
- "in_param_dict": true,
- "cn": "启动风速",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "3.5",
- "value_sc1_4mw": "3.5",
- "value_sc1_4mw_b": "3.5",
- "golden_kk_2014_12": "3.5",
- "value_xuyi_legacy_other_model": "2.5"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rWindRestartAtMaxWind": {
- "codes": [
- "02_11_106"
- ],
- "in_param_dict": true,
- "cn": "大风恢复风速门限阈值",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "18",
- "value_sc1_4mw": "22",
- "value_sc1_4mw_b": "22",
- "golden_kk_2014_12": "22",
- "value_xuyi_legacy_other_model": "18"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rWindSpeedCheckSensors": {
- "codes": [
- "02_11_107"
- ],
- "in_param_dict": true,
- "cn": "监测风速仪、风向标数据不刷新的起始风速值",
- "unit": "m/s",
- "subsystem": "NacelleSystem",
- "values": {
- "default": "2.5",
- "value_sc1_4mw": "3",
- "value_sc1_4mw_b": "3",
- "golden_kk_2014_12": "3",
- "value_xuyi_legacy_other_model": "2"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rWindSpeedLimitToAutoGrease": {
- "codes": [
- "02_10_109"
- ],
- "in_param_dict": true,
- "cn": "允许偏航自润滑的最高风速",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "15",
- "value_sc1_4mw": "25",
- "value_sc1_4mw_b": "25",
- "golden_kk_2014_12": "25",
- "value_xuyi_legacy_other_model": "25"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_rXX": {
- "codes": [
- "04_04_005",
- "04_04_006"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_rYawSensorOffsetAtNorthPos": {
- "codes": [
- "02_10_012"
- ],
- "in_param_dict": true,
- "cn": "机舱对北角度偏差",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "0",
- "value_sc1_4mw": "0",
- "value_sc1_4mw_b": "0",
- "golden_kk_2014_12": "0",
- "value_xuyi_legacy_other_model": "90"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rYawTurnsCableTwistPreSTOP": {
- "codes": [
- "02_10_012",
- "02_10_102"
- ],
- "in_param_dict": true,
- "cn": "预解缆偏航圈数",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "1.4",
- "value_sc1_4mw": "1.4",
- "value_sc1_4mw_b": "1.4",
- "golden_kk_2014_12": "1.4",
- "value_xuyi_legacy_other_model": "2.4"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_rYawTurnsCableTwist_STOP": {
- "codes": [
- "02_10_012"
- ],
- "in_param_dict": true,
- "cn": "一级限位开关偏航角度",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "1.5",
- "value_sc1_4mw": "1.5",
- "value_sc1_4mw_b": "1.5",
- "golden_kk_2014_12": "1.5",
- "value_xuyi_legacy_other_model": "2.5"
- },
- "five_col_identical": false,
- "golden_differs_from_default": false,
- "evidence_tier": "C_partial"
- },
- "PAR_tCBCheckBlockConverterError": {
- "codes": [
- "03_05_005",
- "03_06_014"
- ],
- "in_param_dict": false,
- "evidence_tier": "X_param_not_in_dict"
- },
- "PAR_tCVTWaterCoolHeaterOnWorking": {
- "codes": [
- "03_05_063"
- ],
- "in_param_dict": true,
- "cn": "高澜变频器水冷加热器运行超时",
- "unit": "",
- "subsystem": "ConverterContainer",
- "values": {
- "default": "T#60m",
- "value_sc1_4mw": "T#60m",
- "value_sc1_4mw_b": "T#60m",
- "golden_kk_2014_12": "3600000",
- "value_xuyi_legacy_other_model": "T#60m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tCVT_DCLinkChargeTimeout": {
- "codes": [
- "04_12_015"
- ],
- "in_param_dict": true,
- "cn": "变频器直流母线充电超时",
- "unit": "",
- "subsystem": "ConverterContainer",
- "values": {
- "default": "T#30s",
- "value_sc1_4mw": "T#45s",
- "value_sc1_4mw_b": "T#10s",
- "golden_kk_2014_12": "10000",
- "value_xuyi_legacy_other_model": "T#30s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tCVT_LVRT_Timeout": {
- "codes": [
- "04_12_022"
- ],
- "in_param_dict": true,
- "cn": "LVRT超时时间",
- "unit": "",
- "subsystem": "ConverterContainer",
- "values": {
- "default": "T#5s",
- "value_sc1_4mw": "",
- "value_sc1_4mw_b": "T#5s",
- "golden_kk_2014_12": "5000",
- "value_xuyi_legacy_other_model": ""
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tCVT_MCBCloseTimeout": {
- "codes": [
- "04_12_021"
- ],
- "in_param_dict": true,
- "cn": "变频器合MCB超时时间",
- "unit": "",
- "subsystem": "ConverterContainer",
- "values": {
- "default": "T#20s",
- "value_sc1_4mw": "",
- "value_sc1_4mw_b": "T#20s",
- "golden_kk_2014_12": "20000",
- "value_xuyi_legacy_other_model": ""
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tConverterHeatingModeTimeout": {
- "codes": [
- "03_05_060"
- ],
- "in_param_dict": true,
- "cn": "变频器加热模式超时",
- "unit": "",
- "subsystem": "ConverterContainer",
- "values": {
- "default": "T#60m",
- "value_sc1_4mw": "T#60m",
- "value_sc1_4mw_b": "T#120m",
- "golden_kk_2014_12": "5400000",
- "value_xuyi_legacy_other_model": "T#60m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tDelayCircuitBrakerClose": {
- "codes": [
- "03_05_008"
- ],
- "in_param_dict": true,
- "cn": "变频器主断路器闭合超时",
- "unit": "",
- "subsystem": "ConverterContainer",
- "values": {
- "default": "T#10s",
- "value_sc1_4mw": "T#10s",
- "value_sc1_4mw_b": "T#10s",
- "golden_kk_2014_12": "10000",
- "value_xuyi_legacy_other_model": "T#10s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tDelayForHydraulicsCompressionLevel1": {
- "codes": [
- "02_09_020"
- ],
- "in_param_dict": true,
- "cn": "主回路打压到20BAR超时",
- "unit": "",
- "subsystem": "HSBrakeSystem",
- "values": {
- "default": "T#1s",
- "value_sc1_4mw": "T#1s",
- "value_sc1_4mw_b": "T#1s",
- "golden_kk_2014_12": "15000",
- "value_xuyi_legacy_other_model": "T#1s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tDelayForHydraulicsDecompression": {
- "codes": [
- "02_09_019"
- ],
- "in_param_dict": true,
- "cn": "主回路泄压到0BAR超时",
- "unit": "",
- "subsystem": "HSBrakeSystem",
- "values": {
- "default": "T#1s",
- "value_sc1_4mw": "T#1s",
- "value_sc1_4mw_b": "T#1s",
- "golden_kk_2014_12": "20000",
- "value_xuyi_legacy_other_model": "T#1s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tDelayGearOilFilterClogged_STOP": {
- "codes": [
- "02_05_003"
- ],
- "in_param_dict": true,
- "cn": "油滤堵塞判断时间延迟",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "T#100h",
- "value_sc1_4mw": "T#100h",
- "value_sc1_4mw_b": "T#100h",
- "golden_kk_2014_12": "360000000",
- "value_xuyi_legacy_other_model": "T#15s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tDelayGearOilLevel_STOP": {
- "codes": [
- "02_05_005"
- ],
- "in_param_dict": true,
- "cn": "油位停机故障时间延迟",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "T#20s",
- "value_sc1_4mw": "T#40s",
- "value_sc1_4mw_b": "T#40s",
- "golden_kk_2014_12": "400000",
- "value_xuyi_legacy_other_model": "T#40s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tDelayGearOilLevel_Warning": {
- "codes": [
- "02_05_004"
- ],
- "in_param_dict": true,
- "cn": "油位报警时间延迟",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "T#10s",
- "value_sc1_4mw": "T#20s",
- "value_sc1_4mw_b": "T#20s",
- "golden_kk_2014_12": "200000",
- "value_xuyi_legacy_other_model": "T#20s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tDelayHydPumpTime_MAX": {
- "codes": [
- "02_09_017"
- ],
- "in_param_dict": true,
- "cn": "液压泵运行时间过长时间上限",
- "unit": "",
- "subsystem": "HSBrakeSystem",
- "values": {
- "default": "T#20s",
- "value_sc1_4mw": "T#20s",
- "value_sc1_4mw_b": "T#20s",
- "golden_kk_2014_12": "30000",
- "value_xuyi_legacy_other_model": "T#20s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tGearboxHeatingModeTimeout": {
- "codes": [
- "02_05_110"
- ],
- "in_param_dict": true,
- "cn": "齿轮箱冷启动超时判断",
- "unit": "",
- "subsystem": "Gearbox",
- "values": {
- "default": "T#6h",
- "value_sc1_4mw": "T#6h",
- "value_sc1_4mw_b": "T#6h",
- "golden_kk_2014_12": "21600000",
- "value_xuyi_legacy_other_model": "T#6d"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tGenStatorDewShortCircuit": {
- "codes": [
- "02_08_100"
- ],
- "in_param_dict": true,
- "cn": "发电机定子冷凝故障延时",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "T#30m",
- "value_sc1_4mw": "T#30m",
- "value_sc1_4mw_b": "T#30m",
- "golden_kk_2014_12": "43200000",
- "value_xuyi_legacy_other_model": "T#12h"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tGenWaterCoolHeaterOnWorking": {
- "codes": [
- "02_08_136"
- ],
- "in_param_dict": true,
- "cn": "发电机高澜水冷加热器运行超时",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "T#60m",
- "value_sc1_4mw": "T#60m",
- "value_sc1_4mw_b": "T#60m",
- "golden_kk_2014_12": "3600000",
- "value_xuyi_legacy_other_model": "T#60m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tIntervalMaxPitchComError": {
- "codes": [
- "04_02_036"
- ],
- "in_param_dict": true,
- "cn": "监测变桨通讯报警频繁时间间隔",
- "unit": "",
- "subsystem": "Pitchsystem",
- "values": {
- "default": "t#5m",
- "value_sc1_4mw": "t#5m",
- "value_sc1_4mw_b": "t#5m",
- "golden_kk_2014_12": "300000",
- "value_xuyi_legacy_other_model": ""
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tIntervalMaxStartHydPump": {
- "codes": [
- "02_09_021"
- ],
- "in_param_dict": true,
- "cn": "监测液压泵启动频繁时间间隔",
- "unit": "",
- "subsystem": "HSBrakeSystem",
- "values": {
- "default": "T#10m",
- "value_sc1_4mw": "T#10m",
- "value_sc1_4mw_b": "T#10m",
- "golden_kk_2014_12": "600000",
- "value_xuyi_legacy_other_model": "T#10m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tMaxTimeWithoutPitchMove": {
- "codes": [
- "03_09_110"
- ],
- "in_param_dict": true,
- "cn": "桨叶自润滑周期",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "T#48h",
- "value_sc1_4mw": "T#48h",
- "value_sc1_4mw_b": "T#48h",
- "golden_kk_2014_12": "172800000",
- "value_xuyi_legacy_other_model": "T#48h"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tResonanceModeTimeMax": {
- "codes": [
- "03_09_114"
- ],
- "in_param_dict": true,
- "cn": "风机处于共振区超时",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "T#20s",
- "value_sc1_4mw": "T#30s",
- "value_sc1_4mw_b": "T#30s",
- "golden_kk_2014_12": "30000",
- "value_xuyi_legacy_other_model": "T#30s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tSELFTEST_PitchBatteryStatusError": {
- "codes": [
- "03_09_030",
- "03_09_031",
- "03_09_032"
- ],
- "in_param_dict": true,
- "cn": "桨叶自检超时延时",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "T#12s",
- "value_sc1_4mw": "T#12s",
- "value_sc1_4mw_b": "T#12s",
- "golden_kk_2014_12": "14000",
- "value_xuyi_legacy_other_model": "T#12s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tSetDelayForBatteryChargerFault": {
- "codes": [
- "01_05_062"
- ],
- "in_param_dict": true,
- "cn": "变桨系统电池充电回路故障setdelay",
- "unit": "",
- "subsystem": "Pitchsystem",
- "values": {
- "default": "T#2m",
- "value_sc1_4mw": "T#2m",
- "value_sc1_4mw_b": "T#2m",
- "golden_kk_2014_12": "120000",
- "value_xuyi_legacy_other_model": "T#2m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tSetDelayForCANProfibus": {
- "codes": [
- "01_05_070",
- "01_05_104",
- "01_05_106"
- ],
- "in_param_dict": true,
- "cn": "变桨系统CAN故障Setdelay",
- "unit": "",
- "subsystem": "Pitchsystem",
- "values": {
- "default": "t#120ms",
- "value_sc1_4mw": "t#120ms",
- "value_sc1_4mw_b": "t#120ms",
- "golden_kk_2014_12": "120",
- "value_xuyi_legacy_other_model": "t#120ms"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tSetDelayForEtherCAT": {
- "codes": [
- "03_06_018"
- ],
- "in_param_dict": true,
- "cn": "EtherCAT故障延时",
- "unit": "",
- "subsystem": "PLCSystem",
- "values": {
- "default": "t#100ms",
- "value_sc1_4mw": "t#100ms",
- "value_sc1_4mw_b": "t#100ms",
- "golden_kk_2014_12": "20",
- "value_xuyi_legacy_other_model": "t#100ms"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tSetDelayForFrequencyHigh": {
- "codes": [
- "03_04_010"
- ],
- "in_param_dict": true,
- "cn": "电网频率高延时",
- "unit": "",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "T#30m",
- "value_sc1_4mw": "T#2m",
- "value_sc1_4mw_b": "T#2m",
- "golden_kk_2014_12": "420000",
- "value_xuyi_legacy_other_model": "T#2m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tSetDelayForFrequencyLow": {
- "codes": [
- "03_04_011"
- ],
- "in_param_dict": true,
- "cn": "电网频率低延时",
- "unit": "",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "T#30m",
- "value_sc1_4mw": "T#30m",
- "value_sc1_4mw_b": "T#30m",
- "golden_kk_2014_12": "1920000",
- "value_xuyi_legacy_other_model": "T#30m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tSetDelayForFrequencyMax": {
- "codes": [
- "03_04_020"
- ],
- "in_param_dict": true,
- "cn": "电网频率太高延时",
- "unit": "",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "T#200ms",
- "value_sc1_4mw": "T#200ms",
- "value_sc1_4mw_b": "T#200ms",
- "golden_kk_2014_12": "5000",
- "value_xuyi_legacy_other_model": "T#200ms"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tSetDelayForFrequencyMin": {
- "codes": [
- "03_04_021"
- ],
- "in_param_dict": true,
- "cn": "电网频率太低延时",
- "unit": "",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "T#500ms",
- "value_sc1_4mw": "T#500ms",
- "value_sc1_4mw_b": "T#500ms",
- "golden_kk_2014_12": "8000",
- "value_xuyi_legacy_other_model": "T#500ms"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tSetDelayForGridVoltageLow": {
- "codes": [
- "03_04_006",
- "03_04_007",
- "03_04_008"
- ],
- "in_param_dict": true,
- "cn": "低电压故障延时",
- "unit": "",
- "subsystem": "GridMeasurement",
- "values": {
- "default": "T#5s",
- "value_sc1_4mw": "T#5s",
- "value_sc1_4mw_b": "T#5s",
- "golden_kk_2014_12": "5000",
- "value_xuyi_legacy_other_model": "T#5s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeOutBrakeMode100": {
- "codes": [
- "03_09_012"
- ],
- "in_param_dict": true,
- "cn": "100号刹车超时",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "t#20s",
- "value_sc1_4mw": "t#42s",
- "value_sc1_4mw_b": "t#42s",
- "golden_kk_2014_12": "42000",
- "value_xuyi_legacy_other_model": "T#42s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeOutBrakeMode50": {
- "codes": [
- "03_09_013"
- ],
- "in_param_dict": true,
- "cn": "50号刹车超时",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "t#60s",
- "value_sc1_4mw": "t#60s",
- "value_sc1_4mw_b": "t#60s",
- "golden_kk_2014_12": "60000",
- "value_xuyi_legacy_other_model": "t#60s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeOutBrakeMode51": {
- "codes": [
- "03_09_011"
- ],
- "in_param_dict": true,
- "cn": "51号刹车超时",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "t#60s",
- "value_sc1_4mw": "t#60s",
- "value_sc1_4mw_b": "t#60s",
- "golden_kk_2014_12": "75000",
- "value_xuyi_legacy_other_model": "t#60s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeOutParallelOperationOK": {
- "codes": [
- "03_05_003"
- ],
- "in_param_dict": true,
- "cn": "变频器机侧开启超时",
- "unit": "",
- "subsystem": "ConverterContainer",
- "values": {
- "default": "T#20s",
- "value_sc1_4mw": "T#35s",
- "value_sc1_4mw_b": "T#10s",
- "golden_kk_2014_12": "20000",
- "value_xuyi_legacy_other_model": "T#20s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeOutReadyToOperateOK": {
- "codes": [
- "03_05_001"
- ],
- "in_param_dict": true,
- "cn": "变频器运行在转速范围内,未发送Ready信号超时",
- "unit": "",
- "subsystem": "ConverterContainer",
- "values": {
- "default": "T#20s",
- "value_sc1_4mw": "T#12s",
- "value_sc1_4mw_b": "T#12s",
- "golden_kk_2014_12": "12000",
- "value_xuyi_legacy_other_model": "T#20s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeoutCutInMode": {
- "codes": [
- "04_16_006"
- ],
- "in_param_dict": true,
- "cn": "切入并网超时时间",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "T#1m",
- "value_sc1_4mw": "T#1m",
- "value_sc1_4mw_b": "T#1m",
- "golden_kk_2014_12": "60000",
- "value_xuyi_legacy_other_model": "T#1m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeoutSelftest1": {
- "codes": [
- "04_16_001"
- ],
- "in_param_dict": true,
- "cn": "自检1超时时间",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "T#1m",
- "value_sc1_4mw": "T#1m",
- "value_sc1_4mw_b": "T#1m",
- "golden_kk_2014_12": "60000",
- "value_xuyi_legacy_other_model": "T#1m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeoutSelftest2": {
- "codes": [
- "04_16_002"
- ],
- "in_param_dict": true,
- "cn": "自检2超时时间",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "T#1m",
- "value_sc1_4mw": "T#1m",
- "value_sc1_4mw_b": "T#1m",
- "golden_kk_2014_12": "60000",
- "value_xuyi_legacy_other_model": "T#1m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeoutSelftest3": {
- "codes": [
- "04_16_003"
- ],
- "in_param_dict": true,
- "cn": "自检3超时时间",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "T#1m",
- "value_sc1_4mw": "T#1m",
- "value_sc1_4mw_b": "T#1m",
- "golden_kk_2014_12": "60000",
- "value_xuyi_legacy_other_model": "T#1m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeoutSelftest4": {
- "codes": [
- "04_16_004"
- ],
- "in_param_dict": true,
- "cn": "自检4超时时间",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "T#1m",
- "value_sc1_4mw": "T#1m",
- "value_sc1_4mw_b": "T#15m",
- "golden_kk_2014_12": "1200000",
- "value_xuyi_legacy_other_model": "T#1m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeoutSelftest5": {
- "codes": [
- "04_16_015"
- ],
- "in_param_dict": true,
- "cn": "自检5超时时间",
- "unit": "min",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "T#10m",
- "value_sc1_4mw": "",
- "value_sc1_4mw_b": "T#10m",
- "golden_kk_2014_12": "600000",
- "value_xuyi_legacy_other_model": ""
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tTimeoutStartMode": {
- "codes": [
- "04_16_005"
- ],
- "in_param_dict": true,
- "cn": "启动模式超时时间",
- "unit": "",
- "subsystem": "TurbineStateMachine",
- "values": {
- "default": "T#5m",
- "value_sc1_4mw": "T#10m",
- "value_sc1_4mw_b": "T#10m",
- "golden_kk_2014_12": "600000",
- "value_xuyi_legacy_other_model": "T#5m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tUPS_Batt_Low_Shutdown_Time": {
- "codes": [
- "04_11_026"
- ],
- "in_param_dict": true,
- "cn": "UPS过低持续时长",
- "unit": "",
- "subsystem": "GCC",
- "values": {
- "default": "T#180s",
- "value_sc1_4mw": "T#180s",
- "value_sc1_4mw_b": "T#180s",
- "golden_kk_2014_12": "180000",
- "value_xuyi_legacy_other_model": "T#180s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tWarningToSTOP_GeneratorBrushes": {
- "codes": [
- "02_08_007"
- ],
- "in_param_dict": true,
- "cn": "发电机碳刷磨损停机延时",
- "unit": "",
- "subsystem": "Generator",
- "values": {
- "default": "T#168h",
- "value_sc1_4mw": "T#168h",
- "value_sc1_4mw_b": "T#168h",
- "golden_kk_2014_12": "604800000",
- "value_xuyi_legacy_other_model": "T#96h"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tYawMotorTimeTooLong": {
- "codes": [
- "02_10_010"
- ],
- "in_param_dict": true,
- "cn": "偏航电机运行时间过长延时",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "T#45m",
- "value_sc1_4mw": "T#45m",
- "value_sc1_4mw_b": "T#45m",
- "golden_kk_2014_12": "2700000",
- "value_xuyi_legacy_other_model": "T#45m"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- },
- "PAR_tYawSlowDelay": {
- "codes": [
- "02_10_008"
- ],
- "in_param_dict": true,
- "cn": "偏航速度过慢延时",
- "unit": "",
- "subsystem": "YawSystem",
- "values": {
- "default": "T#20S",
- "value_sc1_4mw": "T#10S",
- "value_sc1_4mw_b": "T#10S",
- "golden_kk_2014_12": "10000",
- "value_xuyi_legacy_other_model": "T#10s"
- },
- "five_col_identical": false,
- "golden_differs_from_default": true,
- "evidence_tier": "B_golden_tuned"
- }
- },
- "code_attributes": {
- "03_05_001": {
- "name": "SC_NoSignalForReadyToOperate",
- "cn": "变频器没有做好运行准备",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeOutReadyToOperateOK",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "03_05_002": {
- "name": "SC_RepFaultNoSignalReadyToOperate",
- "cn": "变频器没有做好运行准备的故障重复出现",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_003": {
- "name": "SC_NoSignalForParallelOperation",
- "cn": "变频器接入电网时间过长",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeOutParallelOperationOK",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_004": {
- "name": "SC_RepFaultNoSignalParallelOperation",
- "cn": "变频器接入电网时间过长故障重复出现",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_005": {
- "name": "SC_FaultInverter_CollectiveInformation",
- "cn": "变频器多种警告",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_027": {
- "name": "SC_ConverterCircuitBrakerTripped",
- "cn": "断路器断开",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_050": {
- "name": "SC_CutInTooFrequently_20m_5",
- "cn": "接入电网动作过于频繁",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#60s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_081": {
- "name": "SC_GridFailureByConverter",
- "cn": "变频器报告电网故障",
- "subsystem": "ConverterContainer",
- "level": "180-电网故障",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_101": {
- "name": "OC_ConverterReadyToOperate",
- "cn": "变频器做好运行准备",
- "subsystem": "ConverterContainer",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_102": {
- "name": "OC_ConverterGridConnected",
- "cn": "变频器报告电网已接入",
- "subsystem": "ConverterContainer",
- "level": "79-无限制发电",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "79",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_103": {
- "name": "OC_ConverterReadyToSwitchON",
- "cn": "变频器做好并网准备",
- "subsystem": "ConverterContainer",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_104": {
- "name": "OC_ConverterCircuitBrakerActive",
- "cn": "变频器报告断路器断开",
- "subsystem": "ConverterContainer",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_014": {
- "name": "SC_InterruptionCANbusConverter",
- "cn": "与变频器CAN通讯故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#15ms",
- "powerup_delay": "T#10s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_001": {
- "name": "OC_CS_Pump1LowON",
- "cn": "冷却系统循环泵1低速电机启动",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_002": {
- "name": "OC_CS_Pump2LowON",
- "cn": "冷却系统循环泵2低速电机启动",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_003": {
- "name": "OC_CS_Pump1HighON",
- "cn": "冷却系统循环泵1高速电机启动",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_004": {
- "name": "OC_CS_Pump2HighON",
- "cn": "冷却系统循环泵2高速电机启动",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_005": {
- "name": "SC_CS_Pump1LowControlManualMode",
- "cn": "冷却系统循环泵1低速电机手动模式开启",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_006": {
- "name": "SC_CS_Pump2LowControlManualMode",
- "cn": "冷却系统循环泵2低速电机手动模式开启",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_007": {
- "name": "SC_CS_Pump1LowControlForcelMode",
- "cn": "冷却系统循环泵1低速电机强制模式开启",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_008": {
- "name": "SC_CS_Pump2LowControlForcelMode",
- "cn": "冷却系统循环泵2低速电机强制模式开启",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_009": {
- "name": "SC_CS_Pump1HighControlManualMode",
- "cn": "冷却系统循环泵1高速电机手动模式开启",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_010": {
- "name": "SC_CS_Pump2HighControlManualMode",
- "cn": "冷却系统循环泵2高速电机手动模式开启",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_011": {
- "name": "SC_CS_Pump1HighControlForcelMode",
- "cn": "冷却系统循环泵1高速电机强制模式开启",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_012": {
- "name": "SC_CS_Pump2HighControlForcelMode",
- "cn": "冷却系统循环泵2高速电机强制模式开启",
- "subsystem": "CoolingSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_013": {
- "name": "SC_CS_GENOutletTempHighWarining",
- "cn": "冷却系统发电机出口温度过高",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_014": {
- "name": "SC_CS_PreLowWaringing",
- "cn": "冷却系统(入口或出口)压力低报警",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_015": {
- "name": "SC_CS_PreLowError",
- "cn": "冷却系统(入口或出口)压力低故障",
- "subsystem": "CoolingSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_016": {
- "name": "SC_CS_PumpOutputTempSensorFault",
- "cn": "冷却系统泵出口PT100故障",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_017": {
- "name": "SC_CS_GENOutletTempSensorFault",
- "cn": "冷却系统发电机出口PT100故障",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_018": {
- "name": "SC_CS_GBXOutletTempSensorFault",
- "cn": "冷却系统齿轮箱出口PT100故障",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": null,
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_019": {
- "name": "SC_CS_PumpOutletPreSensorFault",
- "cn": "冷却系统循环泵压力侧压力传感器故障",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_020": {
- "name": "SC_CS_PumpInletPreSensorFault",
- "cn": "冷却系统循环泵吸入侧压力传感器故障",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_021": {
- "name": "SC_CS_Pump1LowOverload",
- "cn": "水冷循环泵1低速热继触发",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_022": {
- "name": "SC_CS_Pump2LowOverload",
- "cn": "水冷循环泵2低速热继触发",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_023": {
- "name": "SC_CS_Pump1HighOverload",
- "cn": "水冷循环泵1高速热继触发",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_024": {
- "name": "SC_CS_Pump2HighOverload",
- "cn": "水冷循环泵2高速热继触发",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_025": {
- "name": "SC_CS_Pump1MCB",
- "cn": "水冷循环泵1空开跳开",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_026": {
- "name": "SC_CS_Pump2MCB",
- "cn": "水冷循环泵2空开跳开",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_027": {
- "name": "SC_CS_GBXOutletTempHighWarining",
- "cn": "冷却系统齿轮箱出口温度过高",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_13_003": {
- "name": "OC_AsymProxOffsetCalcRequired",
- "cn": "独立变桨需要自动校准",
- "subsystem": "CoreController",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_13_004": {
- "name": "SC_AsymSensorError",
- "cn": "独立变桨控制系统故障",
- "subsystem": "CoreController",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_13_005": {
- "name": "OC_AsymScaleDeltaFault",
- "cn": "独立变桨控制系统标定故障",
- "subsystem": "CoreController",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_032": {
- "name": "SC_NoCOM_C_Task",
- "cn": "与核心控制器通讯失败",
- "subsystem": "CoreController",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_118": {
- "name": "SC_PoweringUp",
- "cn": "主控制器上电初始化",
- "subsystem": "DataFlow",
- "level": "230-上电初始化",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "230",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_132": {
- "name": "SC_Init_Done",
- "cn": "初始化全部完成",
- "subsystem": "DataFlow",
- "level": "20-无原因待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "20",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_104": {
- "name": "OC_PLCPowerUpDelayElapsed",
- "cn": "PLC主任务重启后第一个执行周期完成",
- "subsystem": "DataFlow",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_060": {
- "name": "SC_FaultInputPT100_RotorBearingA",
- "cn": "主轴承温度测量PT100传感器故障",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_04_001": {
- "name": "SC_RotorOverSpeedLevel1",
- "cn": "低速端转速高于1级超速门限值",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms"
- ],
- "detectable_in_10min": false
- },
- "02_04_003": {
- "name": "SC_GeneratorOverSpeedLevel1",
- "cn": "发电机转速高于1级超速门限值",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_005": {
- "name": "SC_RepFaultOverspeedLevel1",
- "cn": "风机低速端或发电机转速高于1级超速门限值故障重复出现",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_006": {
- "name": "SC_RotorSpeedUnequalGeneratorSpeed",
- "cn": "低速端转速与发电机转速不匹配",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1500ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_04_007": {
- "name": "SC_RotorDirectionWrong",
- "cn": "低速端旋转方向错误",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#2s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms"
- ],
- "detectable_in_10min": false
- },
- "02_04_026": {
- "name": "SC_TempRotorBearingA_high",
- "cn": "主轴的轴承座温度过高警告",
- "subsystem": "Drivetrain",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_04_028": {
- "name": "SC_TempRotorBearingA_MAX",
- "cn": "主轴的轴承座温度过高故障",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_04_030": {
- "name": "SC_RepFaultTempRotorBearingA",
- "cn": "主轴的轴承座温度过高警告重复出现",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_039": {
- "name": "SC_GeneratorSpeedUnequalConverter",
- "cn": "主控系统测得的发电机转速与从变频器读得的不匹配",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_04_102": {
- "name": "OC_GeneratorSpeedBelowSlipLimit_MIN",
- "cn": "发电机转速小于切出电网转速",
- "subsystem": "Drivetrain",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms"
- ],
- "detectable_in_10min": false
- },
- "03_09_009": {
- "name": "SC_MaxGenSpeedAtManualOP",
- "cn": "手动控制模式下,发电机转速过大",
- "subsystem": "Drivetrain",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms"
- ],
- "detectable_in_10min": false
- },
- "04_04_001": {
- "name": "SC_MainBearingTempDeviationWarning",
- "cn": "前后主轴承温差异常",
- "subsystem": "DriveTrain",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_005": {
- "name": "SC_RearMainBearingTempWarning",
- "cn": "主轴后轴承温度过高报警",
- "subsystem": "DriveTrain",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_006": {
- "name": "SC_RearMainBearingTempError",
- "cn": "主轴后轴承温度过高故障",
- "subsystem": "DriveTrain",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_007": {
- "name": "SC_FaultPT100_RearMainRotorBearing",
- "cn": "主轴后轴承PT100故障",
- "subsystem": "DriveTrain",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_008": {
- "name": "SC_CouplingSlip",
- "cn": "传动链联轴器打滑",
- "subsystem": "DriveTrain",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_009": {
- "name": "SC_MainBearingsLubLevelLow",
- "cn": "主轴承润滑系统油位过低",
- "subsystem": "DriveTrain",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_010": {
- "name": "SC_MainBearingsLubPreHigh",
- "cn": "主轴承润滑系统油压过高",
- "subsystem": "DriveTrain",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_011": {
- "name": "SC_MainBearingsLubPistonNotMove",
- "cn": "主轴承润滑系统油脂分配器故障",
- "subsystem": "DriveTrain",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_012": {
- "name": "SC_Sensor1GeneratorImpulsesDefect",
- "cn": "发电机#1接近开关失效",
- "subsystem": "DriveTrain",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_013": {
- "name": "SC_Sensor2GeneratorImpulsesDefect",
- "cn": "发电机#2接近开关失效",
- "subsystem": "DriveTrain",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_027": {
- "name": "SC_MotorProtection_GearOilPump",
- "cn": "机舱柜中齿轮箱的油泵电机保护空开跳开",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_029": {
- "name": "SC_MotorProtection_GearFan",
- "cn": "机舱柜中齿轮箱冷却风扇保护空开跳开",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_031": {
- "name": "SC_NacelleFuseGearboxHeater",
- "cn": "机舱柜中齿轮箱油池加热器保护空开跳开",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_042": {
- "name": "SC_NacelleFuseMotorHeater_GearFanAndOilPump",
- "cn": "机舱柜中齿轮箱冷却风扇电机加热器或齿轮箱油泵电机加热器保护空开跳开",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_043": {
- "name": "SC_NacelleFuseHeater_GearOilPipe",
- "cn": "机舱柜中齿轮箱油管加热器保护开关跳开",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_054": {
- "name": "SC_FaultInputPT100_GearOilSump",
- "cn": "齿轮箱油池油温测量PT100传感器故障",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_02_055": {
- "name": "SC_FaultInputPT100_GearOilInlet",
- "cn": "齿轮箱入口油温测量PT100传感器故障",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_02_058": {
- "name": "SC_FaultInputPT100_GearBearingDE",
- "cn": "驱动端轴承温度测量PT100传感器故障",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_02_059": {
- "name": "SC_FaultInputPT100_GearBearingNDE",
- "cn": "非驱动端轴承温度测量PT100传感器故障",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_02_061": {
- "name": "SC_FaultInputPT100_GearBearingInterDE",
- "cn": "齿轮箱驱动端的中间轴温度测量PT100传感器故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_02_062": {
- "name": "SC_FaultInputPT100_GearBearingInterNDE",
- "cn": "齿轮箱非驱动端中间轴温度测量PT100传感器故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_02_064": {
- "name": "SC_FaultAI_GearOilPressureFilterInlet",
- "cn": "齿轮箱过滤器入口压力传感器故障",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_065": {
- "name": "SC_FaultAI_GearOilPressureGBXInlet",
- "cn": "齿轮箱入口压力传感器故障",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_104": {
- "name": "OC_HeaterGearOilPump_ON",
- "cn": "齿轮箱油泵加热器运行",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_105": {
- "name": "OC_GearFanLS_ON",
- "cn": "齿轮箱低速冷却风扇运行",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_106": {
- "name": "OC_GearOilPumpLS_ON",
- "cn": "齿轮箱低速油泵运行",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_107": {
- "name": "OC_GearOilPumpHS_ON",
- "cn": "齿轮箱高速油泵运行",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_108": {
- "name": "OC_GearOilHeater_ON",
- "cn": "齿轮箱油池加热器运行",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_112": {
- "name": "OC_GearFanHS_ON",
- "cn": "齿轮箱高速冷却风扇高速运行",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_113": {
- "name": "OC_HeaterGearFan_ON",
- "cn": "齿轮箱冷却风扇加热器运行",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_130": {
- "name": "OC_GearOilFilter_ON",
- "cn": "齿轮箱精滤器运行",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_132": {
- "name": "SC_GearOilFilter_Overload",
- "cn": "齿轮箱精滤器保护空开跳开",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_001": {
- "name": "SC_GearOilFilterClogged_Warning",
- "cn": "齿轮箱过滤器阻塞警告",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_05_002": {
- "name": "SC_RepFaultGearOilFilterClogged",
- "cn": "齿轮箱过滤器堵塞故障",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_003": {
- "name": "SC_GearOilFilterClogged_STOP",
- "cn": "齿轮箱过滤器阻塞故障,要求停机",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tDelayGearOilFilterClogged_STOP",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_004": {
- "name": "SC_GearOilLevel_Warning",
- "cn": "齿轮箱油池油位警告",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "PAR_tDelayGearOilLevel_Warning",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_005": {
- "name": "SC_GearOilLevel_STOP",
- "cn": "齿轮箱油池油位故障",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tDelayGearOilLevel_STOP",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_006": {
- "name": "SC_RepFaultGearOilLevel",
- "cn": "齿轮箱油池油位警告重复出现",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_008": {
- "name": "SC_GBXFilterOilPressure_MAX_STOP",
- "cn": "齿轮箱油压高于上限值",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#60s",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_05_015": {
- "name": "SC_TempGearOilSump_high",
- "cn": "齿轮箱油池温度过高警告",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_05_016": {
- "name": "SC_TempGearOilSump_low",
- "cn": "齿轮箱油池温度过低警告",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "50",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_05_017": {
- "name": "SC_TempGearOilSump_MAX",
- "cn": "齿轮箱油池温度过高故障",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min",
- "_10min"
- ],
- "detectable_in_10min": false
- },
- "02_05_018": {
- "name": "SC_TempGearOilSump_MIN",
- "cn": "齿轮箱油池温度过低故障",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_05_019": {
- "name": "SC_TempGearOilInlet_high",
- "cn": "齿轮箱入口油温过高警告",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_05_020": {
- "name": "SC_TempGearOilInlet_low",
- "cn": "齿轮箱入口油温过低警告",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_05_021": {
- "name": "SC_TempGearOilInlet_MAX",
- "cn": "齿轮箱入口油温过高故障",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_05_022": {
- "name": "SC_TempGearOilInlet_MIN",
- "cn": "齿轮箱入口油温过低故障",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_05_027": {
- "name": "SC_RepFaultTempGearOilSump",
- "cn": "齿轮箱油池温度高于过高设定值或低于过低设定值故障重复出现",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_028": {
- "name": "SC_TempGearBearingDE_high",
- "cn": "齿轮箱驱动端轴承温度过高警告",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_05_030": {
- "name": "SC_TempGearBearingDE_MAX",
- "cn": "齿轮箱驱动端轴承温度过高故障",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_05_032": {
- "name": "SC_RepFaultTempGearBearingDE",
- "cn": "齿轮箱驱动端轴承温度过于过高设定值或低于过低设定值故障重复出现",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_033": {
- "name": "SC_TempGearBearingNDE_high",
- "cn": "齿轮箱非驱动端轴承温度过高警告",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_05_035": {
- "name": "SC_TempGearBearingNDE_MAX",
- "cn": "齿轮箱非驱动端轴承温度过高故障",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min",
- "_10min"
- ],
- "detectable_in_10min": false
- },
- "02_05_037": {
- "name": "SC_RepFaultTempGearBearingNDE",
- "cn": "齿轮箱非驱动端轴承温度高于过高设定值或低于过低设定值故障重复出现",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_038": {
- "name": "SC_TempGearBearingInterDE_high",
- "cn": "齿轮箱驱动端轴承入口温度过高警告",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_039": {
- "name": "SC_TempGearBearingInterDE_MAX",
- "cn": "齿轮箱驱动端轴承入口温度过高故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_041": {
- "name": "SC_TempGearBearingInterNDE_high",
- "cn": "齿轮箱驱动端轴承入口温度过高警告",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_042": {
- "name": "SC_TempGearBearingInterNDE_MAX",
- "cn": "齿轮箱驱动端轴承入口温度过高故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_043": {
- "name": "SC_GearOilFilter_TempHigh",
- "cn": "齿轮箱过滤器的油温过高",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_044": {
- "name": "SC_GearOilFilter_PressureHigh",
- "cn": "齿轮箱过滤器压力过大",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_045": {
- "name": "SC_GearOilFilterOffLine_Blocking",
- "cn": "齿轮箱精滤器堵塞",
- "subsystem": "GearBox",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "I",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0S",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_100": {
- "name": "OC_NoMonitoringOfGearOilFilter",
- "cn": "齿轮箱过滤器不监测阻塞情况",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_05_110": {
- "name": "SC_GearboxHeatingModeTimeout",
- "cn": "齿轮箱暖机超时",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tGearboxHeatingModeTimeout",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_001": {
- "name": "OC_GearFanLSForceMode",
- "cn": "齿轮箱低速风扇强制模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_002": {
- "name": "OC_GearFanLSManualMode",
- "cn": "齿轮箱低速风扇手动模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_003": {
- "name": "OC_GearFanHSForceMode",
- "cn": "齿轮箱高速风扇强制模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_004": {
- "name": "OC_GearFanHSManualMode",
- "cn": "齿轮箱高速风扇手动模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_005": {
- "name": "OC_GearOilHeaterForceMode",
- "cn": "齿轮箱油池加热器强制模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_006": {
- "name": "OC_GearOilHeaterManualMode",
- "cn": "齿轮箱油池加热器手动模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_007": {
- "name": "OC_GearOilFilterForceMode",
- "cn": "齿轮箱精滤器强制模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_008": {
- "name": "OC_GearOilFilterManualMode",
- "cn": "齿轮箱精滤器手动模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_009": {
- "name": "OC_GearOilPumpLSForceMode",
- "cn": "齿轮箱低速泵强制模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_010": {
- "name": "OC_GearOilPumpLSManualMode",
- "cn": "齿轮箱低速泵手动模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_011": {
- "name": "OC_GearOilPumpHSForceMode",
- "cn": "齿轮箱高速泵强制模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_012": {
- "name": "OC_GearOilPumpHSManualMode",
- "cn": "齿轮箱高速泵手动模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_013": {
- "name": "OC_GearboxFanHeaterForceMode",
- "cn": "齿轮箱风扇加热器强制模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_014": {
- "name": "OC_GearboxFanHeaterManualMode",
- "cn": "齿轮箱风扇加热器手动模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_015": {
- "name": "OC_GearboxOilPumpHeaterForceMode",
- "cn": "齿轮箱油泵加热器强制模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_016": {
- "name": "OC_GearboxOilPumpHeaterManualMode",
- "cn": "齿轮箱油泵加热器手动模式开启",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_017": {
- "name": "SC_GBXOilPumpMotorLS_Overload",
- "cn": "齿轮箱低速泵热继跳开",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_018": {
- "name": "SC_GBXOilPumpMotorHS_Overload",
- "cn": "齿轮箱高速泵热继跳开",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_020": {
- "name": "SC_GBXOilInletPressureTooLow",
- "cn": "齿轮箱油入口压力过低故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_021": {
- "name": "SC_GBXBearingIMS_GSGS_TempHigh",
- "cn": "齿轮箱中速轴(GSGS)温度高警告",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_022": {
- "name": "SC_GBXBearingIMS_GSGS_TempMax",
- "cn": "齿轮箱中速轴(GSGS)温度高故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_023": {
- "name": "SC_GBXBearingIMS_GSRS_TempHigh",
- "cn": "齿轮箱中速轴(GSRS)温度高警告",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_024": {
- "name": "SC_GBXBearingIMS_GSRS_TempMax",
- "cn": "齿轮箱中速轴(GSRS)温度高故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_025": {
- "name": "SC_GBXBearingIMS_RS_TempHigh",
- "cn": "齿轮箱中速轴(RS)温度高警告",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_026": {
- "name": "SC_GBXBearingIMS_RS_TempMax",
- "cn": "齿轮箱中速轴(RS)温度高故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_027": {
- "name": "SC_GBXBearingHSS_GSGS_TempHigh",
- "cn": "齿轮箱高速轴(GSGS)温度高警告",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_028": {
- "name": "SC_GBXBearingHSS_GSGS_TempMax",
- "cn": "齿轮箱高速轴(GSGS)温度高故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_029": {
- "name": "SC_GBXBearingHSS_GSRS_TempHigh",
- "cn": "齿轮箱高速轴(GSRS)温度高警告",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_030": {
- "name": "SC_GBXBearingHSS_GSRS_TempMax",
- "cn": "齿轮箱高速轴(GSRS)温度高故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_031": {
- "name": "SC_FaultAIAI_Gearbox_Bearing_IMS_GSGS_Temp",
- "cn": "齿轮箱中速轴(GSGS)PT100传感器故障",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_032": {
- "name": "SC_FaultAIAI_Gearbox_Bearing_IMS_GSRS_Temp",
- "cn": "齿轮箱中速轴(GSRS)PT100传感器故障",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_033": {
- "name": "SC_FaultAIAI_Gearbox_Bearing_IMS_RS_Temp",
- "cn": "齿轮箱中速轴(RS)PT100传感器故障",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_034": {
- "name": "SC_FaultAIAI_Gearbox_Bearing_HSS_GSGS_Temp",
- "cn": "齿轮箱高速轴(GSGS)PT100传感器故障",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_035": {
- "name": "SC_FaultAIAI_Gearbox_Bearing_HSS_GSRS_Temp",
- "cn": "齿轮箱高速轴(GSRS)PT100传感器故障",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_036": {
- "name": "SC_FaultAIAI_Gearbox_Bearing_HSS_RS_Temp",
- "cn": "齿轮箱高速轴(RS)PT100传感器故障",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_037": {
- "name": "SC_GBXBearingHSS_RS_TempHigh",
- "cn": "齿轮箱高速轴(RS)温度高警告",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_038": {
- "name": "SC_GBXBearingHSS_RS_TempMax",
- "cn": "齿轮箱高速轴(RS)温度高故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_039": {
- "name": "SC_GBXOfflineFitrationSystemMCB",
- "cn": "齿轮箱离线精滤器空开跳开",
- "subsystem": "Gearbox",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_040": {
- "name": "SC_GearOilPumpMotorPreheaterMCB",
- "cn": "齿轮箱油泵加热器空开跳开",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_041": {
- "name": "SC_GearFilterPumpClogging",
- "cn": "齿轮箱油泵滤网堵塞",
- "subsystem": "GearBox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_042": {
- "name": "OC_GearOilPumpValve_ON",
- "cn": "齿轮箱两位三通阀开启",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_043": {
- "name": "OC_GearOilPumpValveForceMode",
- "cn": "齿轮箱两位三通阀强制模式开启",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_044": {
- "name": "OC_GearOilPumpValveManualMode",
- "cn": "齿轮箱两位三通阀手动模式开启",
- "subsystem": "GearBox",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_036": {
- "name": "SC_MotorProtection_GenFanExternal",
- "cn": "机舱柜中发电机冷却风扇保护空开跳开",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_038": {
- "name": "SC_NacelleFuseGenSpaceHeater",
- "cn": "机舱柜中发电机空间加热器保护空开跳开",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_067": {
- "name": "SC_FaultInputPT100_GeneratorStatorU",
- "cn": "发电机定子U相绕组温度测量PT100传感器故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_02_069": {
- "name": "SC_FaultInputPT100_GeneratorStatorV",
- "cn": "发电机定子V相绕组温度测量PT100传感器故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_02_071": {
- "name": "SC_FaultInputPT100_GeneratorStatorW",
- "cn": "发电机定子W相绕组温度测量PT100传感器故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_02_073": {
- "name": "SC_FaultInputPT100_GeneratorBearingDE",
- "cn": "发电机驱动端轴承温度测量PT100传感器故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_02_074": {
- "name": "SC_FaultInputPT100_GeneratorBearingNDE",
- "cn": "发电机非驱动端轴承温度测量PT100传感器故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_02_101": {
- "name": "OC_GenFanExternal_ON",
- "cn": "发电机冷却风扇运行",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_103": {
- "name": "OC_GenSpaceHeaterON",
- "cn": "发电机空间加热器运行",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_128": {
- "name": "SC_MotorProtection_WCSG",
- "cn": "机舱柜中发电机水冷系统保护空开跳开",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_006": {
- "name": "SC_GeneratorBrushesWaste_Warning",
- "cn": "发电机碳刷磨损警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_007": {
- "name": "SC_GeneratorBrushesWaste_STOP",
- "cn": "发电机碳刷磨损故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tWarningToSTOP_GeneratorBrushes",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_012": {
- "name": "SC_GEN_StatorTempDiffExceedLimit",
- "cn": "发电机定子两相绕组温差大于设定值",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_013": {
- "name": "SC_TempGenStatorU_high",
- "cn": "发电机定子U相绕组温度过高警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_014": {
- "name": "SC_TempGenStatorU_low",
- "cn": "发电机定子U相绕组温度过低警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_015": {
- "name": "SC_TempGenStatorU_MAX",
- "cn": "发电机定子U相绕组温度过高故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_016": {
- "name": "SC_TempGenStatorU_min",
- "cn": "发电机定子U相绕组温度过低故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_017": {
- "name": "SC_TempGenStatorV_high",
- "cn": "发电机定子V相绕组温度过高警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_018": {
- "name": "SC_TempGenStatorV_low",
- "cn": "发电机定子V相绕组温度过低警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_019": {
- "name": "SC_TempGenStatorV_MAX",
- "cn": "发电机定子V相绕组温度过高故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_020": {
- "name": "SC_TempGenStatorV_MIN",
- "cn": "发电机定子V相绕组温度过低故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_021": {
- "name": "SC_TempGenStatorW_high",
- "cn": "发电机定子W相绕组温度过高警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_022": {
- "name": "SC_TempGenStatorW_low",
- "cn": "发电机定子W相绕组温度过低警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_023": {
- "name": "SC_TempGenStatorW_MAX",
- "cn": "发电机定子W相绕组温度过高故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_024": {
- "name": "SC_TempGenStatorW_MIN",
- "cn": "发电机定子W相绕组温度过低故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_025": {
- "name": "SC_RepFaultTempGenStator",
- "cn": "发电机定子绕组温度过高或过低警告重复出现",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_026": {
- "name": "SC_TempGenBearingDE_high",
- "cn": "发电机驱动端轴承温度过高警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_027": {
- "name": "SC_TempGenBearingDE_low",
- "cn": "发电机驱动端轴承温度过低警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_028": {
- "name": "SC_TempGenBearingDE_MAX",
- "cn": "发电机驱动端轴承温度过高故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_029": {
- "name": "SC_TempGenBearingDE_MIN",
- "cn": "发电机驱动端轴承温度过低故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_030": {
- "name": "SC_TempGenBearingNDE_high",
- "cn": "发电机非驱动端轴承温度过高警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_031": {
- "name": "SC_TempGenBearingNDE_low",
- "cn": "发电机非驱动端轴承温度过低警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_032": {
- "name": "SC_TempGenBearingNDE_MAX",
- "cn": "发电机非驱动端轴承温度过高故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_033": {
- "name": "SC_TempGenBearingNDE_MIN",
- "cn": "发电机非驱动端轴承温度过低故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_034": {
- "name": "SC_RepFaultTempGenBearing",
- "cn": "发电机轴承温度过高或过低警告重复出现",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_035": {
- "name": "SC_TempGenCoolingInletOrOutlet_high",
- "cn": "发电机冷却系统入口或出口温度过高警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_036": {
- "name": "SC_TempGenCoolingInletOrOutlet_low",
- "cn": "发电机冷却系统入口或出口温度过低警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_037": {
- "name": "SC_TempGenCoolingInletOrOutlet_MAX",
- "cn": "发电机冷却系统入口或出口温度过高故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_038": {
- "name": "SC_TempGenCoolingInletOrOutlet_MIN",
- "cn": "发电机冷却系统入口或出口温度过低故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "02_08_039": {
- "name": "SC_RepFaultTempGenCoolingInletOrOutlet",
- "cn": "发电机冷却系统入口或出口温度过高或过低警告重复出现",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_042": {
- "name": "SC_FaultPT100_GenCoolingInlet",
- "cn": "发电机冷却系统入口PT100传感器故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_043": {
- "name": "SC_FaultPT100_GenCoolingOutlet",
- "cn": "发电机冷却系统出口PT100传感器故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_100": {
- "name": "SC_TempGenStatorDewShortCircuit",
- "cn": "发电机定子温度低于露点温度",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "PAR_tGenStatorDewShortCircuit",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "04_06_001": {
- "name": "SC_TempGenStatorU1Error",
- "cn": "发电机U相温度信号1错误,报警不停机",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_002": {
- "name": "SC_TempGenStatorU2Error",
- "cn": "发电机U相温度信号2错误,报警不停机",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_003": {
- "name": "OC_TempGenStatorU1U2DiffMax",
- "cn": "发电机U相两PT100读书差值过大,报警不停机",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_005": {
- "name": "SC_TempGenStatorV1Error",
- "cn": "发电机V相温度信号1错误,报警不停机",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_006": {
- "name": "SC_TempGenStatorV2Error",
- "cn": "发电机V相温度信号2错误,报警不停机",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_007": {
- "name": "OC_TempGenStatorV1V2DiffMax",
- "cn": "发电机V相两PT100读书差值过大,报警不停机",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_009": {
- "name": "SC_TempGenStatorW1Error",
- "cn": "发电机W相温度信号1错误,报警不停机",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_010": {
- "name": "SC_TempGenStatorW2Error",
- "cn": "发电机W相温度信号2错误,报警不停机",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_011": {
- "name": "OC_TempGenStatorW1W2DiffMax",
- "cn": "发电机W相两PT100读书差值过大,报警不停机",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_013": {
- "name": "OC_GENFanControlManualMode",
- "cn": "发电机风扇控制进入手动模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_014": {
- "name": "OC_GENFanControlForcelMode",
- "cn": "发电机风扇控制进入强制模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_015": {
- "name": "OC_GENHeaterControlManualMode",
- "cn": "发电机加热器控制进入手动模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_016": {
- "name": "OC_GENHeaterControlForceMode",
- "cn": "发电机加热器控制进入强制模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_035": {
- "name": "SC_GENWaterLeakWarning",
- "cn": "发电机空水冷却器漏水警告",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_036": {
- "name": "SC_GENLubricationWarning",
- "cn": "发电机润滑系统警告",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_001": {
- "name": "SC_GenMaxPower10min",
- "cn": "发电机10分钟平均功率高于上限值",
- "subsystem": "GridMeasurement",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "5",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_08_002": {
- "name": "SC_GenMaxPower30s",
- "cn": "发电机30秒平均功率高于上限值",
- "subsystem": "GridMeasurement",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_003": {
- "name": "SC_GenMaxPower1s",
- "cn": "发电机1秒平均功率高于上限值",
- "subsystem": "GridMeasurement",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_08_004": {
- "name": "SC_RepFaultGenMaxPower10min",
- "cn": "发电机10分钟平均功率高于上限值故障重复出现",
- "subsystem": "GridMeasurement",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_009": {
- "name": "SC_DevicePowerUnequalGenPower",
- "cn": "外部设备测得发电机功率与变频器测得的差异大于设定值",
- "subsystem": "GridMeasurement",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_08_040": {
- "name": "SC_RepFaultGenMaxPower30s",
- "cn": "发电机30秒平均功率高于上限值故障重复出现",
- "subsystem": "GridMeasurement",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_041": {
- "name": "SC_RepFaultGenMaxPower1s",
- "cn": "发电机1秒平均功率高于上限值故障重复出现",
- "subsystem": "GridMeasurement",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_002": {
- "name": "SC_GridVoltageL1_high",
- "cn": "电网电压L1相超出上限值",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_003": {
- "name": "SC_GridVoltageL2_high",
- "cn": "电网电压L2相超出上限值",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_004": {
- "name": "SC_GridVoltageL3_high",
- "cn": "电网电压L3相超出上限值",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_005": {
- "name": "SC_RepFaultGridVoltageHigh",
- "cn": "电网电压过高故障重复出现",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_006": {
- "name": "SC_GridVoltageL1_low",
- "cn": "电网电压L1相超出下限值",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForGridVoltageLow",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_007": {
- "name": "SC_GridVoltageL2_low",
- "cn": "电网电压L2相超出下限值",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForGridVoltageLow",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_008": {
- "name": "SC_GridVoltageL3_low",
- "cn": "电网电压L3相超出下限值",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForGridVoltageLow",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_009": {
- "name": "SC_RepFaultGridVoltageLow",
- "cn": "电网电压过低故障重复出现",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_010": {
- "name": "SC_GridFrequencyHigh",
- "cn": "电网频率过高",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForFrequencyHigh",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms"
- ],
- "detectable_in_10min": false
- },
- "03_04_011": {
- "name": "SC_GridFrequencyLow",
- "cn": "电网频率过低",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForFrequencyLow",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms"
- ],
- "detectable_in_10min": false
- },
- "03_04_012": {
- "name": "SC_RepFaultGridFrequency",
- "cn": "电网频率过高过低故障重复出现",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_018": {
- "name": "SC_GridLost_PowerFailure",
- "cn": "掉网故障",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_020": {
- "name": "SC_GridFrequencyMax",
- "cn": "电网频率高于上限值",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForFrequencyMax",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms"
- ],
- "detectable_in_10min": false
- },
- "03_04_021": {
- "name": "SC_GridFrequencyMin",
- "cn": "电网频率低于下限值",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForFrequencyMin",
- "powerup_delay": "T#0s",
- "repeat_n": "10",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms"
- ],
- "detectable_in_10min": false
- },
- "03_04_022": {
- "name": "OC_HVRT_Activated",
- "cn": "高电压穿越",
- "subsystem": "GridMeasurement",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#2m",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_200": {
- "name": "SC_GridCurrentAsymmetric",
- "cn": "电网三相电流不平衡",
- "subsystem": "GridMeasurement",
- "level": "180-电网故障",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#4s",
- "powerup_delay": "T#10s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_101": {
- "name": "OC_PowerAboveShutDown_10min",
- "cn": "发电机10分钟平均功率大于正常运行下限值",
- "subsystem": "GridMeasurement",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_09_102": {
- "name": "OC_PowerAboveShutDown_30s",
- "cn": "发电机30秒平均功率大于正常运行下限值",
- "subsystem": "GridMeasurement",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_041": {
- "name": "SC_MotorProtection_HydrPump",
- "cn": "机舱柜中液压站的液压泵保护空开跳开",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_090": {
- "name": "SC_FaultAI_HydraulicPressurePreCharge",
- "cn": "液压站储能罐压力传感器故障",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_091": {
- "name": "SC_FaultAI_HydraulicPressureSump",
- "cn": "液压站主回路压力传感器故障",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_092": {
- "name": "SC_FaultAI_HydraulicPressureBrake",
- "cn": "液压站刹车回路压力传感器故障",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_093": {
- "name": "SC_NacelleFuseHeaterHydrOil",
- "cn": "液压站油加热器熔丝开关跳开",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_094": {
- "name": "SC_AccumulatorPressure_High",
- "cn": "储能罐压力高",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_095": {
- "name": "SC_AccumulatorPressure_Low",
- "cn": "储能罐压力低",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_100": {
- "name": "OC_Valve1RotorBrake_ON",
- "cn": "机械刹车1号阀动作",
- "subsystem": "HSBrakeSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_109": {
- "name": "OC_HydrPump_ON",
- "cn": "液压站的液压泵运行",
- "subsystem": "HSBrakeSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_117": {
- "name": "OC_Valve2RotorBrake_ON",
- "cn": "机械刹车2号阀动作",
- "subsystem": "HSBrakeSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_118": {
- "name": "OC_Valve3RotorBrake_ON",
- "cn": "机械刹车3号阀动作",
- "subsystem": "HSBrakeSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_119": {
- "name": "OC_Valve4RotorBrake_ON",
- "cn": "机械刹车4号阀动作",
- "subsystem": "HSBrakeSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_07_001": {
- "name": "SC_MotorOverLoad_HydrPump",
- "cn": "液压泵电机过载",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_07_002": {
- "name": "SC_RotorBrakePadsWorn_Alarm",
- "cn": "机械刹车刹车盘磨损警告",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_07_003": {
- "name": "SC_RotorBrakePadsWorn_STOP",
- "cn": "机械刹车刹车盘磨损故障",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_07_005": {
- "name": "SC_RotorBrakeClosed",
- "cn": "机械刹车释放失灵",
- "subsystem": "HSBrakeSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_09_001": {
- "name": "SC_HydrPressureSystemMin_Warning",
- "cn": "液压系统刹车回路压力低于下限值警告",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#3m",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_09_003": {
- "name": "SC_HydrPressureSystemMin_STOP",
- "cn": "液压系统刹车回路压力低于下限值故障",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#3m",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_09_004": {
- "name": "SC_HydrSystemOilTemp_High",
- "cn": "液压系统刹车回路油温过高",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_09_005": {
- "name": "SC_HydrSystemPressMAX_STOP",
- "cn": "液压系统压力高于最大限值",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_09_006": {
- "name": "SC_HydrPressureSystemMainCircuitMin_Warning",
- "cn": "液压系统主回路压力低于下限值警告",
- "subsystem": "HSBrakeSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#3m",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_09_007": {
- "name": "SC_HydrPressureSystemMainCircuitMin_STOP",
- "cn": "液压系统主回路压力低于下限值故障",
- "subsystem": "HSBrakeSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#3m",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_09_008": {
- "name": "OC_ManualControlHydrPump",
- "cn": "液压泵手动控制模式",
- "subsystem": "HSBrakeSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_09_009": {
- "name": "OC_ForceControlHydrPump",
- "cn": "液压泵强制控制模式",
- "subsystem": "HSBrakeSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_09_010": {
- "name": "OC_RemControlHydrStart",
- "cn": "远程控制液压泵启动",
- "subsystem": "HSBrakeSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_09_011": {
- "name": "OC_ManualControlHSBrk",
- "cn": "手动控制液压刹车",
- "subsystem": "HSBrakeSystem",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_09_017": {
- "name": "SC_HydrPumpTime_MAX",
- "cn": "液压泵运行时间过长",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "PAR_tDelayHydPumpTime_MAX",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_09_018": {
- "name": "SC_RepFault_HydrPumpTime_MAX",
- "cn": "液压泵运行时间过长故障重复出现",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_09_019": {
- "name": "SC_HydrPumpDecompressionTimeOut",
- "cn": "液压系统泄压超时",
- "subsystem": "HSBrakeSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tDelayForHydraulicsDecompression",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_09_020": {
- "name": "SC_HydrPumpCompressionLevel1TimeOut",
- "cn": "液压系统打压超时",
- "subsystem": "HSBrakeSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tDelayForHydraulicsCompressionLevel1",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_09_021": {
- "name": "SC_HydrPumpTooManyStarts",
- "cn": "液压泵开启过于频繁",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#30s",
- "repeat_n": "PAR_iNumberMaxStartHydPump",
- "repeat_period": "PAR_tIntervalMaxStartHydPump",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_09_024": {
- "name": "SC_UnfilHydraulicLoadManual",
- "cn": "用户手动释放液压系统压力",
- "subsystem": "HSBrakeSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_09_033": {
- "name": "SC_HYDSumpLevelLow",
- "cn": "液压站液位低",
- "subsystem": "HSBrakeSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "t#0S",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_005": {
- "name": "SC_SELFTEST_BrakeTestFailed",
- "cn": "刹车功能自检失败",
- "subsystem": "HSBrakeSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_002": {
- "name": "SC_LogErrorRingBufferStatuscodes",
- "cn": "状态字数据记录出错",
- "subsystem": "LogSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_011": {
- "name": "SC_LogErrorTrace",
- "cn": "Tracelog记录出错",
- "subsystem": "LogSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_001": {
- "name": "SC_Blade1_OnePitchSensorDefect",
- "cn": "1号桨出现角度传感器故障",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_003": {
- "name": "SC_PitchModeFeedbackError",
- "cn": "变桨系统状态反馈错误",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_004": {
- "name": "SC_Blade1_DetachEndPos91Failed",
- "cn": "1号桨叶从91度限位脱开失败",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_005": {
- "name": "SC_Blade2_DetachEndPos91Failed",
- "cn": "2号桨叶从91度限位脱开失败",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_006": {
- "name": "SC_Blade3_DetachEndPos91Failed",
- "cn": "3号桨叶从91度限位脱开失败",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_009": {
- "name": "SC_Blade1_EndPos95Deg",
- "cn": "1号桨的95度限位开关被撞开",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_011": {
- "name": "SC_Blade1_EndPos91Deg",
- "cn": "1号桨的91度限位开关被撞开",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_016": {
- "name": "SC_Blade1_PositionIncoherence",
- "cn": "1号桨实际值与给定值相差过大",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_021": {
- "name": "SC_Blade2_OnePitchSensorDefect",
- "cn": "2号桨出现角度传感器故障",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_029": {
- "name": "SC_Blade2_EndPos95Deg",
- "cn": "2号桨的95度限位开关被撞开",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_031": {
- "name": "SC_Blade2_EndPos91Deg",
- "cn": "2号桨的91度限位开关被撞开",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_036": {
- "name": "SC_Blade2_PositionIncoherence",
- "cn": "2号桨实际值与给定值相差过大",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_041": {
- "name": "SC_Blade3_OnePitchSensorDefect",
- "cn": "3号桨出现角度传感器故障",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_049": {
- "name": "SC_Blade3_EndPos95Deg",
- "cn": "3号桨的95度限位开关被撞开",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_051": {
- "name": "SC_Blade3_EndPos91Deg",
- "cn": "3号桨的91度限位开关被撞开",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_056": {
- "name": "SC_Blade3_PositionIncoherence",
- "cn": "3号桨实际值与给定值相差过大",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_063": {
- "name": "SC_AllBlades_EndPos91Or95",
- "cn": "1号,2号和3号桨都撞开91度或95度限位开关",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_064": {
- "name": "SC_PitchEmergencyMode",
- "cn": "变桨系统处在紧急模式",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_072": {
- "name": "SC_Pitch_SyncError_Limit1_5s",
- "cn": "两桨叶间的角度差大于设定值(相差1度持续10秒)",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "2",
- "repeat_period": "T#12h",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_073": {
- "name": "SC_Pitch_SyncError_Limit2_1s",
- "cn": "两桨叶间的角度差大于设定值(相差2度持续200毫秒)",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#200ms",
- "powerup_delay": "T#0s",
- "repeat_n": "2",
- "repeat_period": "T#12h",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_06_001": {
- "name": "SC_PitchNoFeedBackEFC_Signal",
- "cn": "主控制器没有收到来自变桨系统的EFC确认信号",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#150ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_018": {
- "name": "SC_NacelleFuse400VPitch",
- "cn": "机舱柜中变桨系统400V电源保护空开跳开",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#1s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_125": {
- "name": "OC_PitchBypassFeatherSwitchPitch_ON",
- "cn": "变桨系统96度限位开关的旁路信号设定发出",
- "subsystem": "Pitchsystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_014": {
- "name": "SC_RotorBoltLocked",
- "cn": "风机风轮锁被锁定",
- "subsystem": "RotorLock",
- "level": "210-维护",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_101": {
- "name": "OC_RotorBoltUnlocked",
- "cn": "风机风轮锁解锁",
- "subsystem": "RotorLock",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_01_001": {
- "name": "SC_SafetyChain_EmergencySTOP1nacelle",
- "cn": "机舱柜柜门急停按钮被拍下触发了紧急停机",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "210",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_01_002": {
- "name": "SC_SafetyChain_EmergencySTOP2nacelle",
- "cn": "机舱柜预留急停按钮节点断开触发了紧急停机",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "210",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_01_003": {
- "name": "SC_SafetyChain_VibrationSwitch",
- "cn": "PCH的振动过大继电器断开导致安全链断开",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#15s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_01_004": {
- "name": "SC_SafetyChain_OverspeedRelayTriggered",
- "cn": "过速继电器断开导致安全链断开",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_01_005": {
- "name": "SC_SafetyChain_SSDSwitch",
- "cn": "PCH的SSD开关断开导致安全链断开",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#15s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_01_006": {
- "name": "SC_SafetyChain_SSDMax",
- "cn": "PCH测得的SSD震动值高于设定值",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms"
- ],
- "detectable_in_10min": false
- },
- "02_01_007": {
- "name": "SC_NacelleNoFeedBack24VOutHumanOrMachine",
- "cn": "机舱人员安全链或机器安全链没有反馈信号",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#120ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_01_101": {
- "name": "OC_SafetyChainResetFromNacelle",
- "cn": "机舱柜安全链复位按钮被按下对安全链进行复位",
- "subsystem": "SafetySystem",
- "level": "185-复位操作",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "185",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_015": {
- "name": "SC_NacelleOL24VOutputsSafetyChain",
- "cn": "机舱人工安全链或机舱机器安全链的24V电源开路",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_002": {
- "name": "SC_RotorOverSpeedLevel2",
- "cn": "风机低速端转速高于2级超速门限值",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_004": {
- "name": "SC_GeneratorOverSpeedLevel2",
- "cn": "发电机转速高于2级超速门限值",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_01_001": {
- "name": "SC_SafetyChainEmergencySTOP_TowerBase",
- "cn": "塔底柜急停按钮被拍下触发了紧急停机",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "210",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_01_003": {
- "name": "SC_TowerNoFeedBack24VOut_Human",
- "cn": "塔底人工安全链没有反馈信号",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#120ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_01_004": {
- "name": "SC_SafetyChainOpenedByConverter",
- "cn": "变频柜上的急停按钮被拍下触发了紧急停机",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_01_005": {
- "name": "SC_TowerNoFeedBack24VOut_Machine",
- "cn": "塔底机器安全链没有反馈信号",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#120ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_01_006": {
- "name": "SC_SafetyChainResetFromTowerBase",
- "cn": "塔底发出复位安全链命令",
- "subsystem": "SafetySystem",
- "level": "185-复位操作",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "185",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_01_007": {
- "name": "SC_SafetyChainResetRemoteOrTargetVISU",
- "cn": "远程发出复位安全链命令",
- "subsystem": "SafetySystem",
- "level": "185-复位操作",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "185",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_01_009": {
- "name": "SC_ResetSatetyChainStart",
- "cn": "系统复位",
- "subsystem": "SafetySystem",
- "level": "185-复位操作",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "185",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_01_010": {
- "name": "SC_SafetyChainOpenedByConverterOverPower",
- "cn": "变频器过功率触发安全链断开",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_013": {
- "name": "SC_TowerFuse24V_SafetyChain",
- "cn": "塔底柜安全链回路24V电源保护空开跳开",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_015": {
- "name": "SC_TowerOL24VOutputsSafetyChain",
- "cn": "塔底柜安全链24V电源开路",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_101": {
- "name": "OC_SafetyChainSingleShotRelayON",
- "cn": "塔底安全链单稳态继电器闭合",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_08_104": {
- "name": "OC_RESET_SAFETY_CHAIN",
- "cn": "风机接收到复位安全链指令",
- "subsystem": "SafetySystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_01_008": {
- "name": "SC_ResetStatusCodesStart",
- "cn": "复位状态字",
- "subsystem": "UserAccess",
- "level": "185-复位操作",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "185",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_08_003": {
- "name": "SC_ForceMajeure",
- "cn": "不可抗力停机",
- "subsystem": "UserAccess",
- "level": "240-不可抗力",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "240",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_08_004": {
- "name": "SC_STOP_RemoteOrServiceNotebook",
- "cn": "远程发出风机停机指令",
- "subsystem": "UserAccess",
- "level": "200-用户停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "200",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_08_006": {
- "name": "SC_OperatorStop",
- "cn": "操作员停机",
- "subsystem": "UserAccess",
- "level": "190-操作员停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "190",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_08_103": {
- "name": "OC_ManualTriggerTraceLog",
- "cn": "远程命令手动触发Tracelog生成",
- "subsystem": "UserAccess",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_300": {
- "name": "SC_STOP_ForGridLimitation",
- "cn": "电网容量原因停机",
- "subsystem": "WindFarm",
- "level": "180-电网故障",
- "reset_mode": "A",
- "type": "I",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_027": {
- "name": "SC_NoHeartBeat_WindparkCOM",
- "cn": "风场通讯故障",
- "subsystem": "WindFarm",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_007": {
- "name": "SC_NacelleFuseHeaterYawMotors",
- "cn": "偏航电机加热器保护空开跳开",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_023": {
- "name": "SC_NacelleMotorProtectionYawMotorsGroup",
- "cn": "机舱柜中偏航电机保护空开跳开",
- "subsystem": "YawSystem",
- "level": "50-偏航警告",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_046": {
- "name": "SC_MotorProtection_YawMotor1",
- "cn": "偏航系统1号电机热保护继电器触发",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_047": {
- "name": "SC_MotorProtection_YawMotor2",
- "cn": "偏航系统2号电机热保护继电器触发",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_048": {
- "name": "SC_MotorProtection_YawMotor3",
- "cn": "偏航系统3号电机热保护继电器触发",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_049": {
- "name": "SC_MotorProtection_YawMotor4",
- "cn": "偏航系统4号电机热保护继电器触发",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_078": {
- "name": "SC_NacelleFuseElectricalMotorBrakeYaw",
- "cn": "机舱柜中偏航电机抱闸的保护空开跳开",
- "subsystem": "YawSystem",
- "level": "50-偏航警告",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_088": {
- "name": "SC_FaultAI_YawPosition",
- "cn": "偏航系统位置传感器故障",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_110": {
- "name": "OC_HeaterYawMotors_ON",
- "cn": "偏航系统电机加热器设定打开",
- "subsystem": "YawSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_114": {
- "name": "OC_YawCW_ON",
- "cn": "偏航系统设定顺时针偏航",
- "subsystem": "YawSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_115": {
- "name": "OC_YawCCW_ON",
- "cn": "偏航系统设定逆时针偏航",
- "subsystem": "YawSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_116": {
- "name": "OC_OpenElectricalYawBrake_ON",
- "cn": "偏航系统电机抱闸设定打开",
- "subsystem": "YawSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_001": {
- "name": "SC_CableTwistMax_CW",
- "cn": "偏航系统顺时针2级限位开关被撞开",
- "subsystem": "YawSystem",
- "level": "50-偏航警告",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#500ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_002": {
- "name": "SC_CableTwistMax_CCW",
- "cn": "偏航系统逆时针2级限位开关被撞开",
- "subsystem": "YawSystem",
- "level": "50-偏航警告",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#500ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_008": {
- "name": "SC_YawSpeedTooSlow",
- "cn": "偏航系统速度过慢",
- "subsystem": "YawSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "PAR_tYawSlowDelay",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_009": {
- "name": "SC_RepFault_YawSpeedTooSlow",
- "cn": "偏航系统速度过慢故障重复出现",
- "subsystem": "YawSystem",
- "level": "50-偏航警告",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_010": {
- "name": "SC_YawMotorTimeTooLong",
- "cn": "偏航系统电机运行时间过长",
- "subsystem": "YawSystem",
- "level": "50-偏航警告",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tYawMotorTimeTooLong",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_011": {
- "name": "SC_STOP_ForBlockedYaw",
- "cn": "机舱与风向偏离过大,但偏航系统被禁止",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_012": {
- "name": "SC_YawPositionEncoderFault",
- "cn": "偏航系统位置编码器数值错误",
- "subsystem": "YawSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_013": {
- "name": "SC_YawAndWinddirDeviationTooHigh",
- "cn": "机舱与风向偏离过大",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_019": {
- "name": "SC_TempYawMotors1_MAX",
- "cn": "偏航系统1号电机PTC测温电阻触发",
- "subsystem": "YawSystem",
- "level": "50-偏航警告",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_020": {
- "name": "SC_TempYawMotors2_MAX",
- "cn": "偏航系统2号电机PTC测温电阻触发",
- "subsystem": "YawSystem",
- "level": "50-偏航警告",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_021": {
- "name": "SC_TempYawMotors3_MAX",
- "cn": "偏航系统3号电机PTC测温电阻触发",
- "subsystem": "YawSystem",
- "level": "50-偏航警告",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_022": {
- "name": "SC_TempYawMotors4_MAX",
- "cn": "偏航系统4号电机PTC测温电阻触发",
- "subsystem": "YawSystem",
- "level": "50-偏航警告",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_101": {
- "name": "SC_YawManualOperation",
- "cn": "偏航系统处于手动模式",
- "subsystem": "YawSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_102": {
- "name": "SC_StartRewindingLoopCables",
- "cn": "偏航系统开始自动解缆",
- "subsystem": "YawSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms",
- "_10min"
- ],
- "detectable_in_10min": false
- },
- "02_10_105": {
- "name": "OC_RewindingLoopCablesActive",
- "cn": "偏航系统处于自动解缆模式",
- "subsystem": "YawSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_106": {
- "name": "SC_AutoGreaseError",
- "cn": "偏航系统自润滑设备故障",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_107": {
- "name": "SC_StartAutoGrease",
- "cn": "偏航系统开始自润滑",
- "subsystem": "YawSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#40s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_109": {
- "name": "SC_PreAutoGrease",
- "cn": "偏航系统自润滑预备",
- "subsystem": "YawSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#40s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms"
- ],
- "detectable_in_10min": false
- },
- "02_10_110": {
- "name": "SC_AutoGreaseErrorBeka",
- "cn": "偏航系统自润滑设备故障",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#60s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_12_003": {
- "name": "SC_ManualYawBySoftware",
- "cn": "远程发出手工偏航命令",
- "subsystem": "YawSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_08_002": {
- "name": "SC_LimitSwitchCableTwistBridged",
- "cn": "旁路扭缆限位开关,重新得电后可以手动解缆",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_001": {
- "name": "SC_Transformer_Gasses_Pressure_Fault",
- "cn": "变压器油中溶解气体或压力过高",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_002": {
- "name": "SC_Transformer_Temp_High",
- "cn": "变压器温度高报警",
- "subsystem": "GCC",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_003": {
- "name": "SC_Transformer_Temp_VeryHigh",
- "cn": "变压器温度高故障",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_004": {
- "name": "SC_Switchgear_LineDisconnector_Open",
- "cn": "高压断路器无负荷开关分闸",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_005": {
- "name": "SC_Switchgear_EarthingContactor_Closed",
- "cn": "高压断路器接地开关合闸",
- "subsystem": "GCC",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_006": {
- "name": "SC_Switchgear_CB_Open",
- "cn": "开关设备打开",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_007": {
- "name": "SC_Switchgear_SF6_Pressure_Low",
- "cn": "SF6压力过低报警",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_009": {
- "name": "SC_Switchgear_MCB_Trip",
- "cn": "开关设备空开跳开",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_010": {
- "name": "SC_Switchgear_CB_Trip",
- "cn": "开关设备断路器跳开",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_011": {
- "name": "SC_Switchgear_CB_Opening_Failure",
- "cn": "开关设备打开失败",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_012": {
- "name": "SC_Switchgear_CB_Closing_Failure",
- "cn": "开关设备闭合失败",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_013": {
- "name": "OC_Switchgear_CB_Closing_Coil",
- "cn": "开关设备正在关闭",
- "subsystem": "GCC",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_014": {
- "name": "OC_Switchgear_CB_Opening_Coil",
- "cn": "开关设备正在打开",
- "subsystem": "GCC",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_015": {
- "name": "SC_Switchboard_690V_In_CB",
- "cn": "电网到690V的CB跳开",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_016": {
- "name": "SC_Switchboard_690V_AuxTrafo_CB",
- "cn": "690V到400V的变压器CB跳开",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_017": {
- "name": "SC_Switchboard_690V_ExtGen_CB",
- "cn": "外部发电机到690V的CB跳开",
- "subsystem": "GCC",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_018": {
- "name": "SC_Switchboard_690V_Group_CB",
- "cn": "至少一个690V的CB跳开",
- "subsystem": "GCC",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_019": {
- "name": "SC_Switchboard_400V_In_CB",
- "cn": "400V配电盘进电开关QTR2闭合",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_020": {
- "name": "SC_Switchboard_400V_UPS_In_CB",
- "cn": "400V配电盘QA12闭合",
- "subsystem": "GCC",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_021": {
- "name": "SC_Switchboard_400V_Group_CB",
- "cn": "400V配电盘(QA1-Q11+Q13-QA16)闭合",
- "subsystem": "GCC",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_022": {
- "name": "SC_Switchboard_400V_UPS_Out_CB",
- "cn": "UPS供电空开QUPS闭合",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_023": {
- "name": "SC_Switchboard_400V_UPS_Group_CB",
- "cn": "230V配电盘(QB1-QB8,QAUX)闭合",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_024": {
- "name": "SC_UPS_AC_Fail",
- "cn": "UPS进电故障",
- "subsystem": "GCC",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_025": {
- "name": "SC_UPS_Batt_Low",
- "cn": "UPS电池电压过低",
- "subsystem": "GCC",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_026": {
- "name": "SC_UPS_Batt_Low_Timeout",
- "cn": "UPS进电故障或电池电压过低超时",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tUPS_Batt_Low_Shutdown_Time",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_029": {
- "name": "SC_GCC_Temp_High",
- "cn": "箱变温度过高报警",
- "subsystem": "GCC",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_030": {
- "name": "SC_GCC_Temp_VeryHigh",
- "cn": "箱变温度过高故障",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_031": {
- "name": "SC_GCC_Temp_Low",
- "cn": "箱变温度过低",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_032": {
- "name": "SC_FaultPT100_GCC_Temp1",
- "cn": "高压室内温度PT100故障",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_033": {
- "name": "SC_FaultPT100_Transformer_Temp",
- "cn": "箱变油温PT100故障",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_14_001": {
- "name": "SC_PowerMeasurementUnit_Fail",
- "cn": "电网测量设备故障",
- "subsystem": "GridMeasurement",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_034": {
- "name": "SC_UPS_Unhealthy",
- "cn": "UPS设备供电时间过短",
- "subsystem": "GCC",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_001": {
- "name": "SC_Safety_Loop_Open",
- "cn": "安全系统断开安全链",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_002": {
- "name": "SC_SafetyController_Not_Alive",
- "cn": "安全控制器失效",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_003": {
- "name": "SC_RotorSpeed_Unequal_SafetyController",
- "cn": "PLC的测得转速与安全控制器不同",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_004": {
- "name": "SC_SSD_Active",
- "cn": "SSD振动触发",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_005": {
- "name": "SC_Tower_Vibration_Active",
- "cn": "塔筒振动过大",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_006": {
- "name": "SC_SafetyChain_RotorOverSpeedError",
- "cn": "过速断开安全链",
- "subsystem": "SafetySystem",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_007": {
- "name": "SC_SafetyChain_WTCAliveSignalError",
- "cn": "来自主控的频率信号丢失断开安全链",
- "subsystem": "SafetySystem",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_008": {
- "name": "SC_SafetyChain_SpeedSensorError",
- "cn": "安全控制器测得转速与主控测得转速不匹配断开安全链",
- "subsystem": "SafetySystem",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_009": {
- "name": "SC_SafetyChain_G_Sensor1_Error",
- "cn": "SSD振动断开安全链",
- "subsystem": "SafetySystem",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_010": {
- "name": "SC_SafetyChain_G_Sensor2_Error",
- "cn": "塔筒振动断开安全链",
- "subsystem": "SafetySystem",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_011": {
- "name": "SC_SafetyChain_EmergencyStopActivated",
- "cn": "急停断开安全链",
- "subsystem": "SafetySystem",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_012": {
- "name": "SC_SafetyChain_YawLimitSwitchActivated",
- "cn": "偏航二级限位断开安全链",
- "subsystem": "SafetySystem",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_013": {
- "name": "SC_SafetyChain_SafetyLoopFeedback_Error",
- "cn": "安全链复位失败",
- "subsystem": "SafetySystem",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_015": {
- "name": "SC_SafetyChain_GeneratorOverSpeedError",
- "cn": "发电机过速断开安全链",
- "subsystem": "SafetySystem",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_007": {
- "name": "SC_Blade1PitchAngleWrong91Pos",
- "cn": "1号桨叶91度限位触发位置故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_008": {
- "name": "SC_Blade2PitchAngleWrong91Pos",
- "cn": "2号桨叶91度限位触发位置故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_009": {
- "name": "SC_Blade3PitchAngleWrong91Pos",
- "cn": "3号桨叶91度限位触发位置故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_010": {
- "name": "SC_Blade1PitchAngleWrong95Pos",
- "cn": "1号桨叶95度限位触发位置故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_011": {
- "name": "SC_Blade2PitchAngleWrong95Pos",
- "cn": "2号桨叶95度限位触发位置故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_012": {
- "name": "SC_Blade3PitchAngleWrong95Pos",
- "cn": "3号桨叶95度限位触发位置故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_013": {
- "name": "SC_UndervoltageBackupAxis1",
- "cn": "1号桨叶后备电源电压过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_014": {
- "name": "SC_UndervoltageBackupAxis2",
- "cn": "2号桨叶后备电源电压过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_015": {
- "name": "SC_UndervoltageBackupAxis3",
- "cn": "3号桨叶后备电源电压过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_016": {
- "name": "SC_OvervoltageBackupAxis1",
- "cn": "1号桨叶后备电源电压过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_017": {
- "name": "SC_OvervoltageBackupAxis2",
- "cn": "2号桨叶后备电源电压过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_018": {
- "name": "SC_OvervoltageBackupAxis3",
- "cn": "3号桨叶后备电源电压过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_019": {
- "name": "SC_OvertemperatureAxisBox1",
- "cn": "1号轴控柜温度过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_020": {
- "name": "SC_OvertemperatureAxisBox2",
- "cn": "2号轴控柜温度过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_021": {
- "name": "SC_OvertemperatureAxisBox3",
- "cn": "3号轴控柜温度过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_022": {
- "name": "SC_UndertemperatureAxisBox1",
- "cn": "1号轴控柜温度过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_023": {
- "name": "SC_UndertemperatureAxisBox2",
- "cn": "2号轴控柜温度过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_024": {
- "name": "SC_UndertemperatureAxisBox3",
- "cn": "3号轴控柜温度过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_025": {
- "name": "SC_InfoTcuActive",
- "cn": "变桨系统发出内部信息",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_026": {
- "name": "SC_WarnTcuActive",
- "cn": "变桨系统发出报警信息",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_027": {
- "name": "SC_ErrTcuActive",
- "cn": "变桨系统发出故障信息",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_028": {
- "name": "SC_ErrPcuActive",
- "cn": "变桨系统出现内部故障",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_029": {
- "name": "SC_Blade1DCLinkVoltageNotOK",
- "cn": "1号桨直流母线电压不正常故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_030": {
- "name": "SC_Blade2DCLinkVoltageNotOK",
- "cn": "2号桨直流母线电压不正常故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_031": {
- "name": "SC_Blade3DCLinkVoltageNotOK",
- "cn": "3号桨直流母线电压不正常故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_032": {
- "name": "SC_24VSupplyAxis1",
- "cn": "1号桨叶24V电源故障",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_033": {
- "name": "SC_24VSupplyAxis2",
- "cn": "2号桨叶24V电源故障",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_034": {
- "name": "SC_24VSupplyAxis3",
- "cn": "3号桨叶24V电源故障",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_035": {
- "name": "SC_PitchCommunicationError",
- "cn": "主控制与变桨间的通讯故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_036": {
- "name": "OC_PitchCANCommunicationError",
- "cn": "主控与变桨之间的Canbus通讯故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "PAR_iNumberMaxPitchComError",
- "repeat_period": "PAR_tIntervalMaxPitchComError",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_037": {
- "name": "OC_PitchProfibusCommunicationError",
- "cn": "主控与变桨之间的无线Profibus通讯故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_038": {
- "name": "SC_PitchInLVRT",
- "cn": "变桨系统处于低电压穿越模式",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_039": {
- "name": "SC_OvertemperatureMotorAxis1",
- "cn": "1号变桨电机温度过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_040": {
- "name": "SC_OvertemperatureMotorAxis2",
- "cn": "2号变桨电机温度过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_041": {
- "name": "SC_OvertemperatureMotorAxis3",
- "cn": "3号变桨电机温度过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_042": {
- "name": "SC_UndertemperatureMotorAxis1",
- "cn": "1号变桨电机温度过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_043": {
- "name": "SC_UndertemperatureMotorAxis2",
- "cn": "2号变桨电机温度过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_044": {
- "name": "SC_UndertemperatureMotorAxis3",
- "cn": "3号变桨电机温度过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_045": {
- "name": "SC_PcuOpenSafetychain",
- "cn": "变桨系统断开EFC反馈信号",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#300ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_046": {
- "name": "SC_TcuOpenSafetychainFirst",
- "cn": "主控先断开了EFC信号",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_050": {
- "name": "SC_Axis1BackupMaintenanceRequired",
- "cn": "1号超级电容需要维护",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_051": {
- "name": "SC_Axis2BackupMaintenanceRequired",
- "cn": "2号超级电容需要维护",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_052": {
- "name": "SC_Axis3BackupMaintenanceRequired",
- "cn": "3号超级电容需要维护",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_053": {
- "name": "SC_Axis1backupTestWarning",
- "cn": "1号超级电容自检报警",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_054": {
- "name": "SC_Axis2backupTestWarning",
- "cn": "2号超级电容自检报警",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_055": {
- "name": "SC_Axis3backupTestWarning",
- "cn": "3号超级电容自检报警",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_056": {
- "name": "SC_Axis1backupTestError",
- "cn": "1号超级电容自检故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_057": {
- "name": "SC_Axis2backupTestError",
- "cn": "2号超级电容自检故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_058": {
- "name": "SC_Axis3backupTestError",
- "cn": "3号超级电容自检故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_060": {
- "name": "SC_LubricationFuseError",
- "cn": "变桨自润滑系统电源故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_061": {
- "name": "SC_LubricationSystemFault",
- "cn": "变桨自润滑系统故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_062": {
- "name": "SC_LubricationLowLevel",
- "cn": "变桨自润滑系统低油位故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_063": {
- "name": "SC_PitchHeatingMode",
- "cn": "变桨系统处于低温预加热模式",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_064": {
- "name": "SC_PitchMasterAxis1error",
- "cn": "1号桨叶的PM出现故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_065": {
- "name": "SC_PitchMasterAxis2error",
- "cn": "2号桨叶的PM出现故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_066": {
- "name": "SC_PitchMasterAxis3error",
- "cn": "3号桨叶的PM出现故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_067": {
- "name": "SC_CommunicationErrorPitchMasterAxis1",
- "cn": "1号桨叶的PM出现通讯故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_068": {
- "name": "SC_CommunicationErrorPitchMasterAxis2",
- "cn": "2号桨叶的PM出现通讯故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_069": {
- "name": "SC_CommunicationErrorPitchMasterAxis3",
- "cn": "3号桨叶的PM出现通讯故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_070": {
- "name": "SC_CommunicationErrorTCU",
- "cn": "变桨系统与主控的通讯出现故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_071": {
- "name": "SC_SafetyLineTCUOpen",
- "cn": "主控断开了EFC信号故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_072": {
- "name": "SC_PCUOpensSafetyLineFirst",
- "cn": "变桨系统先断开EFC信号",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_073": {
- "name": "SC_EmmergencyModeCommandFromTCUViaFieldbus",
- "cn": "主控发出了应急模式命令(信息)",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_074": {
- "name": "SC_SafetyRunStartedAutonomousByPitchmasterAxis1",
- "cn": "1号桨叶开始自主回桨",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_075": {
- "name": "SC_SafetyRunStartedAutonomousByPitchmasterAxis2",
- "cn": "2号桨叶开始自主回桨",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_076": {
- "name": "SC_SafetyRunStartedAutonomousByPitchmasterAxis3",
- "cn": "3号桨叶开始自主回桨",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_077": {
- "name": "SC_SafetyRunTimeout",
- "cn": "安全回桨超时故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_078": {
- "name": "SC_ContactorCyclesGridSupplyAxis",
- "cn": "400V进线主接触器2Q1的吸合次数超过了设计寿命报警",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_079": {
- "name": "SC_GridSupplyErrorAxis1",
- "cn": "1号桨叶400V电源故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_080": {
- "name": "SC_GridSupplyErrorAxis2",
- "cn": "2号桨叶400V电源故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_081": {
- "name": "SC_GridSupplyErrorAxis3",
- "cn": "3号桨叶400V电源故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_082": {
- "name": "SC_LVRTError",
- "cn": "LVRT故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_083": {
- "name": "SC_DClinkFuseErrorAxis1",
- "cn": "1号轴控柜内1F2失效故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_084": {
- "name": "SC_DClinkFuseErrorAxis2",
- "cn": "2号轴控柜内1F2失效故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_085": {
- "name": "SC_DClinkFuseErrorAxis3",
- "cn": "3号轴控柜内1F2失效故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_086": {
- "name": "SC_DiodeMonitoringAxis1",
- "cn": "1号轴控柜内1F1跳开故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_087": {
- "name": "SC_DiodeMonitoringAxis2",
- "cn": "1号轴控柜内1F1跳开故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_088": {
- "name": "SC_DiodeMonitoringAxis3",
- "cn": "1号轴控柜内1F1跳开故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_089": {
- "name": "SC_Mainsupplycontactoropen",
- "cn": "主接触器-2Q1断开",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_090": {
- "name": "SC_ErrorChargerAxis1",
- "cn": "1号轴控柜充电故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_091": {
- "name": "SC_ErrorChargerAxis2",
- "cn": "2号轴控柜充电故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_092": {
- "name": "SC_ErrorChargerAxis3",
- "cn": "3号轴控柜充电故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_093": {
- "name": "SC_ErrorHeatingAxis1",
- "cn": "1号轴控柜加热器故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_094": {
- "name": "SC_ErrorHeatingAxis2",
- "cn": "2号轴控柜加热器故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_095": {
- "name": "SC_ErrorHeatingAxis3",
- "cn": "3号轴控柜加热器故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_096": {
- "name": "SC_OvertemperatureBackupBox1",
- "cn": "1号后备电源柜温度过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_097": {
- "name": "SC_OvertemperatureBackupBox2",
- "cn": "2号后备电源柜温度过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_098": {
- "name": "SC_OvertemperatureBackupBox3",
- "cn": "3号后备电源柜温度过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_099": {
- "name": "SC_UndertemperatureBackupBox1",
- "cn": "1号后备电源柜温度过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_100": {
- "name": "SC_UndertemperatureBackupBox2",
- "cn": "2号后备电源柜温度过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_101": {
- "name": "SC_UndertemperatureBackupBox3",
- "cn": "3号后备电源柜温度过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_102": {
- "name": "SC_WireBreakTemperatureAxisBox1",
- "cn": "1号轴控柜温度传感器断线故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_103": {
- "name": "SC_WireBreakTemperatureAxisBox2",
- "cn": "2号轴控柜温度传感器断线故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_104": {
- "name": "SC_WireBreakTemperatureAxisBox3",
- "cn": "3号轴控柜温度传感器断线故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_105": {
- "name": "SC_WireBreakTemperatureBackupBox1",
- "cn": "1号后备电源柜温度传感器断线故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_106": {
- "name": "SC_WireBreakTemperatureBackupBox2",
- "cn": "2号后备电源柜温度传感器断线故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_107": {
- "name": "SC_WireBreakTemperatureBackupBox3",
- "cn": "3号后备电源柜温度传感器断线故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_108": {
- "name": "SC_WireBreakTemperatureMotorAxis1",
- "cn": "1号变桨电机温度传感器断线故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_109": {
- "name": "SC_WireBreakTemperatureMotorAxis2",
- "cn": "2号变桨电机温度传感器断线故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_110": {
- "name": "SC_WireBreakTemperatureMotorAxis3",
- "cn": "3号变桨电机温度传感器断线故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_111": {
- "name": "SC_WireBreakTemperatureHub",
- "cn": "轮毂温度传感器断线故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_112": {
- "name": "SC_ErrorFanPitchmasterAxis1",
- "cn": "1号PM的风扇故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_113": {
- "name": "SC_ErrorFanPitchmasterAxis2",
- "cn": "2号PM的风扇故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_114": {
- "name": "SC_ErrorFanPitchmasterAxis3",
- "cn": "3号PM的风扇故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_115": {
- "name": "SC_BackupSwitchopenaxis1",
- "cn": "1号轴控柜超级电容开关-1Q1断开",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_116": {
- "name": "SC_BackupSwitchopenaxis2",
- "cn": "2号轴控柜超级电容开关-1Q1断开",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_117": {
- "name": "SC_BackupSwitchopenaxis3",
- "cn": "3号轴控柜超级电容开关-1Q1断开",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_118": {
- "name": "SC_ContactorCyclesDCSupplyAxis1",
- "cn": "1号轴控柜内接触器3Q1的吸合次数超过了设计寿命报警",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_119": {
- "name": "SC_ContactorCyclesDCSupplyAxis2",
- "cn": "2号轴控柜内接触器3Q1的吸合次数超过了设计寿命报警",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_120": {
- "name": "SC_ContactorCyclesDCSupplyAxis3",
- "cn": "3号轴控柜内接触器3Q1的吸合次数超过了设计寿命报警",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_123": {
- "name": "SC_OvertemperatureLBA",
- "cn": "中心柜温度过高故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_124": {
- "name": "SC_UndertemperatureLBA",
- "cn": "中心柜温度过低故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_125": {
- "name": "SC_WireBreakTemperatureLBA",
- "cn": "中心柜温度传感器断线故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_126": {
- "name": "SC_OvertemperatureHub",
- "cn": "轮毂温度过高警告",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_127": {
- "name": "SC_UndertemperatureHub",
- "cn": "轮毂温度过低警告",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1S",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_128": {
- "name": "SC_HVRTdetected",
- "cn": "HVRT level1 警告",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_129": {
- "name": "SC_HVRTLevel2detected",
- "cn": "HVRT level2 警告",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_130": {
- "name": "SC_HVRTLevel2toolong",
- "cn": "HVRT 故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_131": {
- "name": "SC_PitchInReboot",
- "cn": "远程重启变桨系统",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_053": {
- "name": "SC_FaultInputPT100_Nacelle",
- "cn": "机舱温度测量PT100传感器故障",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_02_077": {
- "name": "SC_FaultInputPT100_Outdoor",
- "cn": "舱外环境温度测量PT100传感器故障",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_02_089": {
- "name": "SC_FaultAI_SensorWindDirection",
- "cn": "风向标故障",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_111": {
- "name": "OC_HeaterWindSensors_ON",
- "cn": "风速仪和风向标的加热器开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_03_001": {
- "name": "SC_TempNacelle_high",
- "cn": "机舱温度过高警告",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_03_002": {
- "name": "SC_TempNacelle_low",
- "cn": "机舱温度过低警告",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_03_003": {
- "name": "SC_TempNacelle_max",
- "cn": "机舱温度过高故障",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_03_004": {
- "name": "SC_TempNacelle_min",
- "cn": "机舱温度过低故障",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_03_005": {
- "name": "SC_RepFaultTempNacelle",
- "cn": "机舱温度过高或过低警告重复出现",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_018": {
- "name": "SC_VibrationOmniDirectionLevel1",
- "cn": "塔架水平方向的加速度高于1级振动门限值",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#2s",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_019": {
- "name": "SC_VibrationOmniDirectionLevel2",
- "cn": "塔架水平方向的加速度高于2级振动门限值",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#2s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_020": {
- "name": "SC_RepFaultVibrationYAxis",
- "cn": "阵风过大保护性停机",
- "subsystem": "NacelleSystem",
- "level": "139-大风停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "139",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_021": {
- "name": "SC_VibrationForeaftDirection1",
- "cn": "塔架前后方向的加速度高于1级振动门限值",
- "subsystem": "NacelleSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#2s",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_022": {
- "name": "SC_VibrationForeaftDirection2",
- "cn": "塔架前后方向的加速度高于2级振动门限值",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#2s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_023": {
- "name": "SC_RepFaultVibrationZAxis",
- "cn": "阵风过大保护性停机",
- "subsystem": "NacelleSystem",
- "level": "139-大风停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "139",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_024": {
- "name": "OC_VibrationOmniDirection",
- "cn": "塔架水平方向的加速度超限",
- "subsystem": "NacelleSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_025": {
- "name": "OC_VibrationForeaftDirection",
- "cn": "塔架前后方向的加速度超限",
- "subsystem": "NacelleSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_10_111": {
- "name": "SC_BlockYawForVibrationHigh",
- "cn": "前后方向振动值过大禁止偏航一分钟",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_11_001": {
- "name": "SC_ConstantSignalVane1",
- "cn": "风向标静止不动",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_11_008": {
- "name": "SC_ConstantSignalAnemometer1",
- "cn": "风速仪静止不动",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_11_009": {
- "name": "OC_ConstantWindVaneReadings",
- "cn": "风向标读数不变",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#20s",
- "powerup_delay": "T#5m",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_11_010": {
- "name": "OC_RestartWindVane",
- "cn": "重启风向标",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "2",
- "repeat_period": "T#1m",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_11_016": {
- "name": "SC_TempOutdoor_high",
- "cn": "舱外环境温度过高警告",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_11_017": {
- "name": "SC_TempOutdoor_low",
- "cn": "舱外环境温度过低警告",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_11_018": {
- "name": "SC_TempOutdoor_MAX",
- "cn": "舱外环境温度过高故障",
- "subsystem": "NacelleSystem",
- "level": "159-环境温度停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "159",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_11_019": {
- "name": "SC_TempOutdoor_MIN",
- "cn": "舱外环境温度过低故障",
- "subsystem": "NacelleSystem",
- "level": "159-环境温度停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "159",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_11_020": {
- "name": "SC_RepFault_TempOutdoor",
- "cn": "舱外环境温度过高或过低警告重复出现",
- "subsystem": "NacelleSystem",
- "level": "159-环境温度停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "1",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "159",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_11_101": {
- "name": "SC_ShutDownWindspeed_1sMax",
- "cn": "1秒平均风速高于上限值",
- "subsystem": "NacelleSystem",
- "level": "139-大风停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "139",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_11_102": {
- "name": "SC_ShutDownWindspeed_30sMax",
- "cn": "30秒平均风速高于上限值",
- "subsystem": "NacelleSystem",
- "level": "139-大风停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "139",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_11_103": {
- "name": "SC_ShutDownWindspeed_10minMax",
- "cn": "10分钟平均风速高于上限值",
- "subsystem": "NacelleSystem",
- "level": "139-大风停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "139",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_11_104": {
- "name": "OC_WaitingForWind",
- "cn": "10分钟平均风速低于启动风速",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_11_105": {
- "name": "OC_MeanWindSpeedAboveActivatingYaw",
- "cn": "风速条件允许偏航系统进行对风",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_11_106": {
- "name": "OC_MeanWindSpeedAboveRestartMaxWind",
- "cn": "1秒平均风速过高",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_11_107": {
- "name": "OC_NoMonitoringWindSensors",
- "cn": "风速过低,不对风速仪和风向标进行监测",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_11_109": {
- "name": "SC_ShutDownWindspeed_10minMin",
- "cn": "风速过低停机",
- "subsystem": "NacelleSystem",
- "level": "129-小风停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "129",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_11_112": {
- "name": "OC_MeanWindSpeedAboveCableUnwindingOK",
- "cn": "风速过高,不能自动解缆",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_11_113": {
- "name": "SC_WindSpeedTooHighForManualModeOrService",
- "cn": "风速过高,不能手动变桨和手动操作风机",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_14_001": {
- "name": "SC_PCH_BadDataDetected",
- "cn": "主控系统读得的PCH震动值长时间不刷新",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#30s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_14_002": {
- "name": "OC_PCHScaleFactorEqualZero",
- "cn": "PCH读取的振动值系数为0",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_03_101": {
- "name": "SC_FaultInputPT100_Cable",
- "cn": "电缆温度PT100故障",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_03_102": {
- "name": "OC_CableOverTempToDisableOverPower",
- "cn": "当电缆温度超过某个值后,则限制超发功能",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_004": {
- "name": "SC_SELFTEST_PCHTestFailed",
- "cn": "PCH自检失败",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_001": {
- "name": "SC_NacelleFireAlarm",
- "cn": "机舱火警系统触发",
- "subsystem": "NacelleSystem",
- "level": "175-故障停机(强)",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_002": {
- "name": "SC_NacelleFireAlarmSystemDefect",
- "cn": "机舱火警系统失效",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_003": {
- "name": "SC_FTWindSensorFail",
- "cn": "FT风速风向传感器故障",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_004": {
- "name": "SC_FTHeaterMCB",
- "cn": "FT加热器空开跳开",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_005": {
- "name": "SC_AnalogWindDirectionHeaterMCB",
- "cn": "风向标加热器空开跳开",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_006": {
- "name": "SC_AnalogWindSpeedHeaterMCB",
- "cn": "风速仪加热器空开跳开",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_008": {
- "name": "SC_MaxDeviationWindDirection",
- "cn": "不同传感器测得风向偏差过大",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#20s",
- "powerup_delay": "T#1m",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "04_09_009": {
- "name": "SC_MaxDeviationWindSpeed",
- "cn": "不同传感器测得风速偏差过大",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#20s",
- "powerup_delay": "T#1m",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_010": {
- "name": "SC_NacelleHumidityHigh",
- "cn": "机舱湿度过大",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_011": {
- "name": "SC_ForceMode_NacelleOutletDamper",
- "cn": "机舱出口气流调节器强制模式开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_012": {
- "name": "SC_NacelleOutletDamperMCB",
- "cn": "机舱出口气流调节器空开跳开",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_013": {
- "name": "OC_NacelleOutletDamper_ON",
- "cn": "机舱出口气流调节器打开",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_014": {
- "name": "SC_ManualMode_NacelleOutletDamper",
- "cn": "机舱出口气流调节器手动模式开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_015": {
- "name": "SC_ForceMode_NacelleOutletFan",
- "cn": "机舱出口风扇强制模式开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_016": {
- "name": "SC_NacelleOutletFan1MCB",
- "cn": "机舱出口风扇1空开跳开",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_017": {
- "name": "SC_NacelleOutletFan1Overload",
- "cn": "机舱出口风扇1热继跳开",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_018": {
- "name": "SC_NacelleOutletFan2MCB",
- "cn": "机舱出口风扇2空开跳开",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_019": {
- "name": "SC_NacelleOutletFan2Overload",
- "cn": "机舱出口风扇2热继跳开",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_020": {
- "name": "OC_NacelleOutletFan1_ON",
- "cn": "机舱出口风扇1开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_021": {
- "name": "OC_NacelleOutletFan2_ON",
- "cn": "机舱出口风扇2开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_022": {
- "name": "SC_ManualMode_NacelleOutletFan",
- "cn": "机舱出口风扇手动模式开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_023": {
- "name": "SC_ForceMode_NacelleInletDamper",
- "cn": "机舱入口气流调节器强制模式开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_024": {
- "name": "SC_NacelleInletDamperMCB",
- "cn": "机舱入口气流调节器空开跳开",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_025": {
- "name": "OC_NacelleInletDamper_ON",
- "cn": "机舱入口气流调节器打开",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_026": {
- "name": "SC_ManualMode_NacelleInletDamper",
- "cn": "机舱入口气流调节器手动模式开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_027": {
- "name": "SC_ForceMode_NacelleHeater",
- "cn": "机舱加热器强制模式开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_028": {
- "name": "SC_NacelleHeaterMCB",
- "cn": "机舱加热器空开跳开",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_029": {
- "name": "OC_NacelleHeater_ON",
- "cn": "机舱加热器开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_030": {
- "name": "SC_ManualMode_NacelleHeater",
- "cn": "机舱加热器手动模式开启",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_031": {
- "name": "SC_AviationLightMCB",
- "cn": "航空灯空开跳开",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_032": {
- "name": "SC_AviationLightStatus",
- "cn": "航空灯故障",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_009": {
- "name": "SC_TempCabinetNacelle_high",
- "cn": "机舱控制柜温度过高警告",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_02_010": {
- "name": "SC_TempCabinetNacelle_low",
- "cn": "机舱控制柜温度过低警告",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_02_011": {
- "name": "SC_TempCabinetNacelle_MAX",
- "cn": "机舱控制柜温度过高故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_02_012": {
- "name": "SC_TempCabinetNacelle_MIN",
- "cn": "机舱控制柜温度过低故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_02_013": {
- "name": "SC_RepFaultTempCabinetNacelle",
- "cn": "机舱控制柜温度过高或过低警告重复出现",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_052": {
- "name": "SC_FaultInputPT100_CabinetNacelle",
- "cn": "机舱控制柜温度测量PT100传感器故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "02_12_001": {
- "name": "SC_ManualSTOP_NacelleOrTowerBase",
- "cn": "机舱或塔底发出停机命令",
- "subsystem": "Cabinet",
- "level": "200-用户停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "200",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_002": {
- "name": "SC_TowerBaseUPS_Alarm",
- "cn": "变频柜230V UPS警告",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#60s",
- "powerup_delay": "T#1s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_023": {
- "name": "SC_FaultInputPT100_TempTowerBase",
- "cn": "塔底温度测量PT100传感器故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_02_024": {
- "name": "SC_TempCabinetTowerBase_high",
- "cn": "塔底控制柜温度过高警告",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_02_025": {
- "name": "SC_TempCabinetTowerBase_low",
- "cn": "塔底控制柜温度过低警告",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_02_026": {
- "name": "SC_TempCabinetTowerBase_MAX",
- "cn": "塔底控制柜温度过高故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_02_027": {
- "name": "SC_TempCabinetTowerBase_MIN",
- "cn": "塔底控制柜温度过低故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_02_028": {
- "name": "SC_RepFaultTempCabinetTowerBase",
- "cn": "塔底控制柜温度过高或过低警告重复出现",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_039": {
- "name": "SC_FaultInputPT100_TempCabinetTowerBase",
- "cn": "塔底控制柜温度测量PT100传感器故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_08_001": {
- "name": "SC_TurbineInServiceTowerBase",
- "cn": "塔底柜维护开关打开,要求风机进入维护模式",
- "subsystem": "Cabinet",
- "level": "210-维护",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_03_001": {
- "name": "SC_RotorLock_Pin1NotUnlocked",
- "cn": "风轮锁1不在退出位置",
- "subsystem": "RotorLock",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_03_002": {
- "name": "SC_RotorLock_Pin2NotUnlocked",
- "cn": "风轮锁2不在退出位置",
- "subsystem": "RotorLock",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_03_003": {
- "name": "SC_RotorLock_PushOutPressureOK",
- "cn": "风轮锁退出压力正常",
- "subsystem": "RotorLock",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_03_004": {
- "name": "SC_RotorLock_PinPositionError",
- "cn": "在空转或发电状态,风轮锁不在退出位置",
- "subsystem": "RotorLock",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_03_005": {
- "name": "SC_RotorLock_PushOutPressureLowWarning",
- "cn": "在空转或发电状态,风轮锁退出压力过低报警",
- "subsystem": "RotorLock",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_03_006": {
- "name": "SC_RotorLock_PushOutPressureLowError",
- "cn": "在空转或发电状态,风轮锁退出压力过低停机",
- "subsystem": "RotorLock",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_03_007": {
- "name": "SC_RotorLock_PushOutPressureSensorFault",
- "cn": "风轮锁退出压力传感器故障",
- "subsystem": "RotorLock",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_001": {
- "name": "SC_CC_690V_Supply_Fault",
- "cn": "变频器690V供电故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_002": {
- "name": "SC_CC_400V_Supply_Fault",
- "cn": "变频器400V供电故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_003": {
- "name": "SC_CC_230V_UPS_Supply_Fault",
- "cn": "变频器230V UPS供电故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_004": {
- "name": "SC_CC_Temp_High",
- "cn": "变频柜温度高报警",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_005": {
- "name": "SC_CC_Temp_VeryHigh",
- "cn": "变频柜温度高故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_006": {
- "name": "SC_CC_Temp_Low",
- "cn": "变频柜温度低故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_007": {
- "name": "SC_CC_AirCon_Fault",
- "cn": "变频柜空调故障",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#1s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_008": {
- "name": "SC_CC_SmokeDetect",
- "cn": "变频柜中烟雾报警器触发",
- "subsystem": "ConverterContainer",
- "level": "175-故障停机(强)",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#1s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_009": {
- "name": "SC_FaultInputPT100_CC_One",
- "cn": "变频柜中一个PT100故障",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_010": {
- "name": "SC_FaultInputPT100_CC_Both",
- "cn": "变频柜中两个PT100故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_011": {
- "name": "SC_Heater_Supply_Coverter1_MCB",
- "cn": "变频器1的加热器供电空开跳开",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_012": {
- "name": "SC_Heater_Supply_Coverter2_MCB",
- "cn": "变频器2的加热器供电空开跳开",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_013": {
- "name": "SC_Converters_Alarm",
- "cn": "变频器报告警告",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_014": {
- "name": "SC_Converter_BrakeChopperActive",
- "cn": "变频器Chopper开启",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_015": {
- "name": "SC_Converter_DCLinkChargeTimeOut",
- "cn": "变频器直流母线充电超时",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tCVT_DCLinkChargeTimeout",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_013": {
- "name": "SC_ReturnOfGrid_RideThrough",
- "cn": "LVRT模式下电网恢复",
- "subsystem": "TurbineStateMachine",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_014": {
- "name": "SC_FaultRestartAfterReturnOfGrid",
- "cn": "LVRT模式下电网恢复后风机重新启动",
- "subsystem": "TurbineStateMachine",
- "level": "180-电网故障",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "180",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_017": {
- "name": "SC_VoltageOutOfRange_RideThrough",
- "cn": "LVRT模式下电网电压超限",
- "subsystem": "TurbineStateMachine",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_321": {
- "name": "OC_UserLimitPower",
- "cn": "用户限功率",
- "subsystem": "TurbineStateMachine",
- "level": "99-用户限功率发电",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "99",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_04_322": {
- "name": "OC_SystemLimitPower",
- "cn": "主控限功率",
- "subsystem": "TurbineStateMachine",
- "level": "89-主控限功率发电",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "89",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_136": {
- "name": "OC_ShutDownOutput",
- "cn": "系统故障时关闭输出",
- "subsystem": "TurbineStateMachine",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_07_005": {
- "name": "SC_TestBrakeProgram50",
- "cn": "Scada发出50#刹车测试指令",
- "subsystem": "TurbineStateMachine",
- "level": "210-维护",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_07_006": {
- "name": "SC_TestBrakeProgram51",
- "cn": "Scada发出51#刹车测试指令",
- "subsystem": "TurbineStateMachine",
- "level": "210-维护",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_07_007": {
- "name": "SC_TestBrakeProgram100",
- "cn": "Scada发出100#刹车测试指令",
- "subsystem": "TurbineStateMachine",
- "level": "210-维护",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_07_008": {
- "name": "SC_TestBrakeProgram198",
- "cn": "Scada发出198#刹车测试指令",
- "subsystem": "TurbineStateMachine",
- "level": "210-维护",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_07_011": {
- "name": "SC_TestBrakeProgram200",
- "cn": "Scada发出150#刹车测试指令",
- "subsystem": "TurbineStateMachine",
- "level": "210-维护",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_001": {
- "name": "SC_TURBINE_AVAILABLE",
- "cn": "风机正常运行",
- "subsystem": "TurbineStateMachine",
- "level": "69-启动",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#5s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "69",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_008": {
- "name": "OC_ManualTurbineControlActive",
- "cn": "Scada发出手动控制风机指令",
- "subsystem": "TurbineStateMachine",
- "level": "210-维护",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_011": {
- "name": "SC_TimeOut_BP51",
- "cn": "51号刹车模式时间过长",
- "subsystem": "TurbineStateMachine",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeOutBrakeMode51",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms",
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "03_09_012": {
- "name": "SC_TimeOut_BP100",
- "cn": "100号刹车模式时间过长",
- "subsystem": "TurbineStateMachine",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeOutBrakeMode100",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms",
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "03_09_013": {
- "name": "SC_TimeOut_BP50",
- "cn": "50号刹车模式时间过长",
- "subsystem": "TurbineStateMachine",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeOutBrakeMode50",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_105": {
- "name": "OC_DelayRestartActive",
- "cn": "风机处于故障后允许复位延迟过程中",
- "subsystem": "TurbineStateMachine",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_110": {
- "name": "OC_ActivatePitchMove",
- "cn": "变桨自润滑启用",
- "subsystem": "TurbineStateMachine",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "PAR_tMaxTimeWithoutPitchMove",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms"
- ],
- "detectable_in_10min": false
- },
- "03_09_111": {
- "name": "SC_ForceSelfTestEvery720h",
- "cn": "720小时强制自检",
- "subsystem": "TurbineStateMachine",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#10s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_114": {
- "name": "SC_TowerResonanceModeTimeOut",
- "cn": "升速过程中处于共振区时间过长",
- "subsystem": "TurbineStateMachine",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "PAR_tResonanceModeTimeMax",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_120": {
- "name": "OC_TurbineHeatingMode",
- "cn": "风机暖机模式",
- "subsystem": "TurbineStateMachine",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_001": {
- "name": "SC_YawLubricationGreasePressureHigh",
- "cn": "偏航润滑油脂压力过高",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_002": {
- "name": "SC_YawLubricationGreaseLevelLow",
- "cn": "偏航润滑油脂油位过低",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_003": {
- "name": "SC_MotorProtection_YawMotor5",
- "cn": "偏航系统5号电机热保护继电器触发",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_004": {
- "name": "SC_MotorProtection_YawMotor6",
- "cn": "偏航系统6号电机热保护继电器触发",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_005": {
- "name": "SC_Yaw_Motor_1_MCB",
- "cn": "1#偏航电机空开跳开",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_006": {
- "name": "SC_Yaw_Motor_2_MCB",
- "cn": "2#偏航电机空开跳开",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_007": {
- "name": "SC_Yaw_Motor_3_MCB",
- "cn": "3#偏航电机空开跳开",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_008": {
- "name": "SC_Yaw_Motor_4_MCB",
- "cn": "4#偏航电机空开跳开",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_009": {
- "name": "SC_Yaw_Motor_5_MCB",
- "cn": "5#偏航电机空开跳开",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_010": {
- "name": "SC_Yaw_Motor_6_MCB",
- "cn": "6#偏航电机空开跳开",
- "subsystem": "YawSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_011": {
- "name": "SC_Yaw_Stopped_MaxNum_Failure",
- "cn": "偏航电机失效数量过大",
- "subsystem": "YawSystem",
- "level": "50-偏航警告",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "50",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_012": {
- "name": "SC_YawMotorsHeaterForceMode",
- "cn": "偏航加热器强制模式开启",
- "subsystem": "YawSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_013": {
- "name": "SC_YawMotorsHeaterManualMode",
- "cn": "偏航加热器手动模式开启",
- "subsystem": "YawSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_014": {
- "name": "SC_YawForceMode",
- "cn": "偏航强制模式开启",
- "subsystem": "YawSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_016": {
- "name": "SC_Converter_MasterSlaveConfigureNotFinished",
- "cn": "变频器主从配置没有完成",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_001": {
- "name": "SC_TimeOut_Selftest1",
- "cn": "自检1运行超时",
- "subsystem": "TurbineStateMachine",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeoutSelftest1",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_002": {
- "name": "SC_TimeOut_Selftest2",
- "cn": "自检2运行超时",
- "subsystem": "TurbineStateMachine",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeoutSelftest2",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_003": {
- "name": "SC_TimeOut_Selftest3",
- "cn": "自检3运行超时",
- "subsystem": "TurbineStateMachine",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeoutSelftest3",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_004": {
- "name": "SC_TimeOut_Selftest4",
- "cn": "自检4运行超时",
- "subsystem": "TurbineStateMachine",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeoutSelftest4",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_005": {
- "name": "SC_TimeOut_StartMode",
- "cn": "启动模式运行超时",
- "subsystem": "TurbineStateMachine",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeoutStartMode",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_006": {
- "name": "SC_TimeOut_CutInMode",
- "cn": "切入并网超时",
- "subsystem": "TurbineStateMachine",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeoutCutInMode",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_007": {
- "name": "SC_NacellePositionInSector1",
- "cn": "机舱位置处在扇区1",
- "subsystem": "TurbineStateMachine",
- "level": "79-无限制发电",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_008": {
- "name": "SC_NacellePositionInSector2",
- "cn": "机舱位置处在扇区2",
- "subsystem": "TurbineStateMachine",
- "level": "79-无限制发电",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_009": {
- "name": "SC_NacellePositionInSector3",
- "cn": "机舱位置处在扇区3",
- "subsystem": "TurbineStateMachine",
- "level": "79-无限制发电",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_010": {
- "name": "SC_NacellePositionInSector4",
- "cn": "机舱位置处在扇区4",
- "subsystem": "TurbineStateMachine",
- "level": "79-无限制发电",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_132": {
- "name": "SC_Blade1PositionCheckAlarm",
- "cn": "1号桨叶角度检查偏差过大警告",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_133": {
- "name": "SC_Blade2PositionCheckAlarm",
- "cn": "2号桨叶角度检查偏差过大警告",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_134": {
- "name": "SC_Blade3PositionCheckAlarm",
- "cn": "3号桨叶角度检查偏差过大警告",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "165",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_135": {
- "name": "SC_Pitch230VLineSupplyCBTrip",
- "cn": "230V信号线供电CB跳开",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_136": {
- "name": "SC_PitchBackUpTest",
- "cn": "远程设定变桨后备电源自检测试",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_137": {
- "name": "SC_PitchForceMode",
- "cn": "变桨系统处于强制模式,桨角可任意给定",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_138": {
- "name": "SC_PitchEncoderSet",
- "cn": "变桨系统设置编码器",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_139": {
- "name": "SC_PitchCANComErrorTooFrequent",
- "cn": "变桨CAN通讯报警频繁",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_020": {
- "name": "SC_HarddiskOverflow",
- "cn": "CF卡中的Tracelog过多",
- "subsystem": "LogSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_008": {
- "name": "SC_DivisionByZero",
- "cn": "除数为零错误",
- "subsystem": "PLCSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_009": {
- "name": "SC_MaxCycleTimeMainPLCTask",
- "cn": "PLC-Task1任务执行超时",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_012": {
- "name": "SC_MaxCycleTimeFASTTask",
- "cn": "PLC-Task2任务执行超时",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_008": {
- "name": "SC_MaxCycleTimeTask3",
- "cn": "PLC-Task3任务执行超时",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_013": {
- "name": "SC_RepFaultMaxCycleTimeTask",
- "cn": "PLC-Task1或Task2或Task3任务执行超时故障重复出现",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_123": {
- "name": "OC_PLCPowerUp",
- "cn": "PLC正在启动中",
- "subsystem": "PLCSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_124": {
- "name": "SC_UpdateModeON",
- "cn": "远程命令PLC程序升级",
- "subsystem": "PLCSystem",
- "level": "250-升级",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "250",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_126": {
- "name": "SC_RebootPLC",
- "cn": "远程命令主控制器重启(操作系统,TwinCAT,应用程序)",
- "subsystem": "PLCSystem",
- "level": "250-升级",
- "reset_mode": "M",
- "type": "F",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "250",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_133": {
- "name": "SC_ParOutOfRange",
- "cn": "参数设定超限",
- "subsystem": "PLCSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_135": {
- "name": "OC_UpdateModeReady",
- "cn": "升级模式准备就绪",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_100ms",
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "03_06_018": {
- "name": "SC_InterruptionEtherCAT",
- "cn": "EtherCAT通讯故障",
- "subsystem": "PLCSystem",
- "level": "175-故障停机(强)",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForEtherCAT",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "100",
- "bp_runtime_2015": "175",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_035": {
- "name": "OC_NoCOM_EtherCAT",
- "cn": "EtherCAT通讯出错",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_031": {
- "name": "SC_RepFault_COM_BKEK_TurbineInternal",
- "cn": "塔底EK1100,机舱EK1100或BK1250通讯故障多次出现",
- "subsystem": "PLCSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_030": {
- "name": "SC_RestoreStatisticsFileFailed",
- "cn": "读取统计量参数文件失败",
- "subsystem": "PLCSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_031": {
- "name": "SC_RestoreUniqueParFileFailed",
- "cn": "读取个性化参数文件失败",
- "subsystem": "PLCSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_032": {
- "name": "SC_RestoreGoldenParFileFailed",
- "cn": "读取通用性参数文件失败",
- "subsystem": "PLCSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_033": {
- "name": "SC_StoreStatisticsFileFailed",
- "cn": "存储统计量参数文件失败",
- "subsystem": "PLCSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_034": {
- "name": "SC_StoreUniqueParFileFailed",
- "cn": "存储个性化参数文件失败",
- "subsystem": "PLCSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_035": {
- "name": "SC_StoreGoldenParFileFailed",
- "cn": "存储通用性参数文件失败",
- "subsystem": "PLCSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_017": {
- "name": "SC_NoCOM_EK1501Nacelle",
- "cn": "机舱EK1501通讯故障",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_018": {
- "name": "SC_NoCOM_BK1120Nacelle",
- "cn": "机舱BK1120通讯故障",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_021": {
- "name": "SC_NoCOM_EK1252Nacelle",
- "cn": "机舱EK1252通讯故障",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_024": {
- "name": "SC_NoCOM_BK1250TowerBase",
- "cn": "塔底BK1250通讯故障",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_026": {
- "name": "SC_NoCOM_EK1501TowerBase",
- "cn": "塔底EK1501通讯故障",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_028": {
- "name": "SC_NoCOM_EK1501Converter",
- "cn": "变频器EK1501通讯故障",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_023": {
- "name": "SC_NoCOM_BK1250Nacelle",
- "cn": "机舱BK1250通讯故障",
- "subsystem": "PLCSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_025": {
- "name": "SC_NoCOM_EK1100Nacelle",
- "cn": "机舱EK1100通讯故障",
- "subsystem": "PLCSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_036": {
- "name": "SC_NoCOM_EL6751Nacelle",
- "cn": "机舱EL6751通讯故障",
- "subsystem": "PLCSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_030": {
- "name": "SC_NoCOM_EL6731Pitch",
- "cn": "机舱EL6731通讯故障",
- "subsystem": "PLCSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_028": {
- "name": "SC_NoCOM_EK1100TowerBase",
- "cn": "塔底EK1100通讯故障",
- "subsystem": "PLCSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_06_029": {
- "name": "SC_NoCOM_EL6751Converter",
- "cn": "变频器EL6751通讯故障",
- "subsystem": "PLCSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_015": {
- "name": "SC_NoCOM_EK1501GCC",
- "cn": "GCC-EK1501通讯故障",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_016": {
- "name": "SC_NoCOM_BK1250GCC",
- "cn": "GCC-BK1250通讯故障",
- "subsystem": "PLCSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#15ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_014": {
- "name": "SC_SoftSafetyChain_Tripped",
- "cn": "硬件安全链失效,软件安全链动作",
- "subsystem": "SafetySystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_045": {
- "name": "SC_FaultAI_GearOilDiffPressureInlineFilter",
- "cn": "齿轮箱过滤器压差传感器故障",
- "subsystem": "Gearbox",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_047": {
- "name": "SC_GBXOilInletPressure_MAX_Stop",
- "cn": "齿轮箱入口压力过高故障",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_046": {
- "name": "SC_RepFaultGBXOilInletPressure_Stop",
- "cn": "齿轮箱入口压力过高或过低故障重复出现",
- "subsystem": "Gearbox",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_033": {
- "name": "SC_FaultAI_NacelleWindSpeed",
- "cn": "Thies风向标故障",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_034": {
- "name": "SC_FaultAI_Nacelle_Humidity",
- "cn": "机舱湿度传感器故障",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_035": {
- "name": "SC_WindIrisData_NotValid",
- "cn": "激光雷达数据无效",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_036": {
- "name": "OC_WindIrisForControl",
- "cn": "当前采用激光雷达进行偏航控制",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_014": {
- "name": "SC_FaultAI_RotorSpeedFromOverspeedRelay",
- "cn": "过速传感器故障",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_036": {
- "name": "SC_RestoreStorageFileFailed",
- "cn": "读取掉电保存变量文件失败",
- "subsystem": "PLCSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_037": {
- "name": "SC_StoreStorageFileFailed",
- "cn": "存储掉电保存变量文件失败",
- "subsystem": "PLCSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_018": {
- "name": "SC_TorqeuForceMode",
- "cn": "扭矩强制模式开启,扭矩可以随意设定",
- "subsystem": "ConverterContainer",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_07_001": {
- "name": "SC_BrakePressureHighUnderProduction",
- "cn": "发电时刹车压力高故障",
- "subsystem": "HSBrakeSystem",
- "level": "170-故障停机",
- "reset_mode": "F",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_07_002": {
- "name": "SC_HSBrakeIsWorking",
- "cn": "高速刹车投入中",
- "subsystem": "HSBrakeSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_005": {
- "name": "SC_FaultInputAirPressure",
- "cn": "大气压力传感器故障",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_001": {
- "name": "SC_PCH_HubBlade1_PeakAlert",
- "cn": "桨叶1振动峰值过高警告",
- "subsystem": "MeasurementSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_002": {
- "name": "SC_PCH_HubBlade1_PeakDanger",
- "cn": "桨叶1振动峰值过高危险警告",
- "subsystem": "MeasurementSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_003": {
- "name": "SC_PCH_HubBlade1_PPAlert",
- "cn": "桨叶1峰-峰值过高警告",
- "subsystem": "MeasurementSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_004": {
- "name": "SC_PCH_HubBlade1_PPDanger",
- "cn": "桨叶1峰-峰值过高危险警告",
- "subsystem": "MeasurementSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_005": {
- "name": "SC_PCH_HubBlade2_PeakAlert",
- "cn": "桨叶2振动峰值过高警告",
- "subsystem": "MeasurementSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_006": {
- "name": "SC_PCH_HubBlade2_PeakDanger",
- "cn": "桨叶2振动峰值过高危险警告",
- "subsystem": "MeasurementSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_007": {
- "name": "SC_PCH_HubBlade2_PPAlert",
- "cn": "桨叶2峰-峰值过高警告",
- "subsystem": "MeasurementSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_008": {
- "name": "SC_PCH_HubBlade2_PPDanger",
- "cn": "桨叶2峰-峰值过高危险警告",
- "subsystem": "MeasurementSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_009": {
- "name": "SC_PCH_HubBlade3_PeakAlert",
- "cn": "桨叶3振动峰值过高警告",
- "subsystem": "MeasurementSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_010": {
- "name": "SC_PCH_HubBlade3_PeakDanger",
- "cn": "桨叶3振动峰值过高危险警告",
- "subsystem": "MeasurementSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_011": {
- "name": "SC_PCH_HubBlade3_PPAlert",
- "cn": "桨叶3峰-峰值过高警告",
- "subsystem": "MeasurementSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_012": {
- "name": "SC_PCH_HubBlade3_PPDanger",
- "cn": "桨叶3峰-峰值过高危险警告",
- "subsystem": "MeasurementSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_013": {
- "name": "SC_PCH_HubFFTBlade1_Alert",
- "cn": "桨叶1频谱强度异常警告",
- "subsystem": "MeasurementSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_014": {
- "name": "SC_PCH_HubFFTBlade1_Danger",
- "cn": "桨叶1频谱强度异常危险警告",
- "subsystem": "MeasurementSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#3h",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_015": {
- "name": "SC_PCH_HubFFTBlade2_Alert",
- "cn": "桨叶2频谱强度异常警告",
- "subsystem": "MeasurementSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_016": {
- "name": "SC_PCH_HubFFTBlade2_Danger",
- "cn": "桨叶2频谱强度异常危险警告",
- "subsystem": "MeasurementSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#3h",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_017": {
- "name": "SC_PCH_HubFFTDangerRepeat",
- "cn": "桨叶频谱危险警告反复出现",
- "subsystem": "MeasurementSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_018": {
- "name": "SC_PCH_HubBadDataDetected",
- "cn": "主控系统读得的叶片PCH震动值长时间不刷新",
- "subsystem": "MeasurementSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#30s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_019": {
- "name": "OC_PCH_HubScaleFactorEqualZero",
- "cn": "叶片PCH读取的振动值系数为0",
- "subsystem": "MeasurementSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_101": {
- "name": "SC_FaultPofibusWCSG",
- "cn": "主控系统与发电机水冷系统Profibus通讯故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#2m",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_102": {
- "name": "SC_EmergencyModeOfWCSG",
- "cn": "发电机水冷系统急停被拍下触发了紧急停机",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_103": {
- "name": "SC_PumpOverLoadOfWCSG",
- "cn": "发电机水冷系统循环泵过载",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_104": {
- "name": "SC_TempHighOfWCSG",
- "cn": "发电机水冷系统过温",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_105": {
- "name": "SC_PreHighOfWCSG",
- "cn": "发电机水冷系统过压",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_106": {
- "name": "SC_PreLowOfWCSG",
- "cn": "发电机水冷系统压力过低",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_107": {
- "name": "SC_NotReadyOfWCSG",
- "cn": "发电机水冷系统没有做好运行准备",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_108": {
- "name": "SC_FaultStatusOfWCSG",
- "cn": "发电机水冷系统故障模式",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_109": {
- "name": "SC_TempLowOfWCSG",
- "cn": "发电机水冷系统温度过低",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_110": {
- "name": "SC_TempSignalErrorOfWCSG",
- "cn": "发电机水冷系统温度信号错误",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_111": {
- "name": "SC_PreSignalErrorOfWCSG",
- "cn": "发电机水冷系统压力信号错误",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_112": {
- "name": "SC_ServiceModeOfWCSG",
- "cn": "发电机水冷系统本地模式",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_113": {
- "name": "SC_OverLoadFanOfWCSG",
- "cn": "发电机水冷系统散热器过载",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_116": {
- "name": "OC_GenWaterCoolValveTimeOut",
- "cn": "发电机水冷三通阀长时间不打开或不闭合",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_117": {
- "name": "SC_GenWaterCoolPumpAlarm",
- "cn": "发电机水冷主循环泵或电加热器或三通阀开关跳闸",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#3s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_118": {
- "name": "SC_GLGenWaterCoolInletPT100Fault",
- "cn": "发电机水冷供水温度传感器TT01 故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_119": {
- "name": "OC_GLGenWaterCoolOutletTemp",
- "cn": "发电机水冷回水温度传感器TT02 故障",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_120": {
- "name": "OC_GLGenWaterCoolInletPre",
- "cn": "发电机水冷供水压力变送器PT01 故障",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_121": {
- "name": "OC_GLGenWaterCoolOutletPre",
- "cn": "发电机水冷回水压力变送器PT02 故障",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_122": {
- "name": "SC_GLGenWaterCoolInletTempHigh2",
- "cn": "发电机水冷供水温度过高故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_123": {
- "name": "OC_GLGenWaterCoolInletTempHigh1",
- "cn": "发电机水冷供水温度过高警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_124": {
- "name": "SC_GLGenWaterCoolOutletTempHigh",
- "cn": "发电机水冷回水温度高",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_125": {
- "name": "SC_GLGenWaterCoolInletPreHigh2",
- "cn": "发电机水冷供水压力过高故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_126": {
- "name": "OC_GLGenWaterCoolInletPreHigh1",
- "cn": "发电机水冷供水压力过高警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_127": {
- "name": "OC_GLGenWaterCoolInletPreLow1",
- "cn": "发电机水冷供水压力过低警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_128": {
- "name": "SC_GLGenWaterCoolInletPreLow2",
- "cn": "发电机水冷供水压力过低故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_129": {
- "name": "OC_GLGenWaterCoolOutletPreLow1",
- "cn": "发电机水冷回水压力过低警告",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_130": {
- "name": "SC_GLGenWaterCoolOutletPreLow2",
- "cn": "发电机水冷回水压力过低故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_131": {
- "name": "OC_GLGenWaterCoolInletTempLow",
- "cn": "发电机水冷供水温度低",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_132": {
- "name": "OC_GenWaterCoolFan1Alarm",
- "cn": "发电机水冷空散电机1或2或3开关跳闸",
- "subsystem": "Generator",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_133": {
- "name": "SC_GenWaterCoolInOutPressureDiffHigh",
- "cn": "发电机水冷入口、出口压差过大故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_134": {
- "name": "SC_GenWaterCoolInOutPressureDiffLow",
- "cn": "发电机水冷入口、出口压差过低故障",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_135": {
- "name": "OC_GenWaterCoolInOutPressureDetect",
- "cn": "发电机水冷系统压力建立,达到加热器启动条件",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_136": {
- "name": "SC_GenWaterCoolHeaterOnTooLong",
- "cn": "发电机水冷加热器加热时间过长",
- "subsystem": "Generator",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tGenWaterCoolHeaterOnWorking",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_017": {
- "name": "OC_GENGLPumpControlManualMode",
- "cn": "发电机高澜水冷系统泵控制进入手动模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_018": {
- "name": "OC_GENGLPumpControlForceMode",
- "cn": "发电机高澜水冷系统泵控制进入强制模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_019": {
- "name": "OC_GENGLHeaterControlManualMode",
- "cn": "发电机高澜水冷系统加热器控制进入手动模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_020": {
- "name": "OC_GENGLHeaterControlForceMode",
- "cn": "发电机高澜水冷系统加热器控制进入强制模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_021": {
- "name": "OC_GENGLValveControlManualMode",
- "cn": "发电机高澜水冷系统三通阀控制进入手动模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_022": {
- "name": "OC_GENGLValveControlForceMode",
- "cn": "发电机高澜水冷系统三通阀控制进入强制模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_023": {
- "name": "OC_GENGLFan1ControlManualMode",
- "cn": "发电机高澜水冷系统风扇1控制进入手动模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_024": {
- "name": "OC_GENGLFan1ControlForceMode",
- "cn": "发电机高澜水冷系统风扇1控制进入强制模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_025": {
- "name": "OC_GENGLFan2ControlManualMode",
- "cn": "发电机高澜水冷系统风扇2控制进入手动模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_026": {
- "name": "OC_GENGLFan2ControlForceMode",
- "cn": "发电机高澜水冷系统风扇2控制进入强制模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_027": {
- "name": "OC_GENGLFan3ControlManualMode",
- "cn": "发电机高澜水冷系统风扇3控制进入手动模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_028": {
- "name": "OC_GENGLFan3ControlForceMode",
- "cn": "发电机高澜水冷系统风扇3控制进入强制模式",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_029": {
- "name": "OC_GENGLPumpON",
- "cn": "发电机高澜水冷系统泵开启",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_030": {
- "name": "OC_GENGLHeaterON",
- "cn": "发电机高澜水冷系统加热器开启",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_031": {
- "name": "OC_GENValveON",
- "cn": "发电机高澜水冷系统三通阀开启",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_032": {
- "name": "OC_GLFan1ON",
- "cn": "发电机高澜水冷系统风扇1开启",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_033": {
- "name": "OC_GLFan2ON",
- "cn": "发电机高澜水冷系统风扇2开启",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_06_034": {
- "name": "OC_GLFan3ON",
- "cn": "发电机高澜水冷系统风扇3开启",
- "subsystem": "Generator",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_102": {
- "name": "SC_MotorProtection_WCSC",
- "cn": "变频器水冷系统保护空开触发",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_008": {
- "name": "SC_ConverterNoFeedBackForSwitchON_CB",
- "cn": "断路器长时间不响应闭合命令",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tDelayCircuitBrakerClose",
- "powerup_delay": "T#10s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_028": {
- "name": "SC_ConverterCrowbarActive",
- "cn": "变频器过压保护被触发",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_051": {
- "name": "OC_CVTWaterCoolInletPreHigh1",
- "cn": "变频器水冷供水压力高报警",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_052": {
- "name": "OC_CVTWaterCoolInletPreLow1",
- "cn": "变频器水冷供水压力低报警",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_053": {
- "name": "SC_CVTWaterCoolInletPreLow2",
- "cn": "变频器水冷供水压力低故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_054": {
- "name": "OC_CVTWaterCoolOutletPreLow1",
- "cn": "变频器水冷回水压力低报警",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_055": {
- "name": "SC_CVTWaterCoolOutletPreLow2",
- "cn": "变频器水冷回水压力低故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_056": {
- "name": "OC_CVTWaterCoolInletTempLow",
- "cn": "变频器水冷供水温度低",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_057": {
- "name": "OC_CVTWaterCoolFanAlarm",
- "cn": "变频器水冷空散电机或三通阀开关跳闸(空冷器电机跳闸)",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_058": {
- "name": "SC_CVTWaterCoolInletPreHigh2",
- "cn": "变频器水冷供水压力高故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_059": {
- "name": "OC_CVTWaterCoolValveTimeOut",
- "cn": "变频器水冷三通阀长时间不打开或不闭合",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_060": {
- "name": "SC_ConverterHeatingModeTimeOut",
- "cn": "变频器处于暖机模式时间过长",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tConverterHeatingModeTimeout",
- "powerup_delay": "T#1s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_061": {
- "name": "SC_CVTWaterCoolInOutPressureDiffHigh",
- "cn": "变频器水冷入口、出口压差过大",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_062": {
- "name": "SC_CVTWaterCoolInOutPressureDiffLow",
- "cn": "变频器水冷入口、出口压差太低",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_063": {
- "name": "SC_CVTWaterCoolHeaterOnTooLong",
- "cn": "变频器水冷加热器加热时间过长",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tCVTWaterCoolHeaterOnWorking",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_113": {
- "name": "OC_ConverterHeatingModeHardWire",
- "cn": "变频器暖机模式",
- "subsystem": "ConverterContainer",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_115": {
- "name": "OC_ConverterHeatingModeCanBus",
- "cn": "变频器暖机模式",
- "subsystem": "ConverterContainer",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_116": {
- "name": "OC_CVTWaterCoolInOutPressureDetect",
- "cn": "变频器水冷系统压力建立,达到加热器启动条件",
- "subsystem": "ConverterContainer",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0S",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_017": {
- "name": "SC_FaultOvervoltageProtectionConverter",
- "cn": "变频柜主电源防雷器故障",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_029": {
- "name": "SC_FaultPofibusWCSC",
- "cn": "与变频器水冷系统PROFIBUS通讯故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#2m",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_030": {
- "name": "SC_EmergencyModeOfWCSC",
- "cn": "变频器水冷系统急停被拍下",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_031": {
- "name": "SC_PumpOverLoadOfWCSC",
- "cn": "变频器水冷系统循环泵过载",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_032": {
- "name": "SC_TempHighOfWCSC",
- "cn": "变频器水冷系统过温",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_033": {
- "name": "SC_PreHighOfWCSC",
- "cn": "变频器水冷系统过压",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_034": {
- "name": "SC_PreLowOfWCSC",
- "cn": "变频器水冷系统压力过低",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_035": {
- "name": "SC_NotReadyOfWCSC",
- "cn": "变频器水冷系统没有准备好",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_036": {
- "name": "SC_FaultStatusOfWCSC",
- "cn": "变频器水冷系统故障模式",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_037": {
- "name": "SC_TempLowOfWCSC",
- "cn": "变频器水冷系统温度过低",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_038": {
- "name": "SC_TempSignalErrorOfWCSC",
- "cn": "变频器水冷系统温度信号错误",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_039": {
- "name": "SC_PreSignalErrorOfWCSC",
- "cn": "变频器水冷系统压力信号错误",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_040": {
- "name": "SC_ServiceModeOfWCSC",
- "cn": "变频器水冷系统维护模式",
- "subsystem": "ConverterContainer",
- "level": "210-维护",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_041": {
- "name": "SC_OverLoadFanOfWCSC",
- "cn": "变频器水冷系统散热器过载",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#60s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_042": {
- "name": "SC_CVTWaterCoolPumpAlarm",
- "cn": "变频器水冷主循环泵或电加热器故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#3s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_043": {
- "name": "SC_CVTWaterCoolInletTemp",
- "cn": "变频器水冷供水温度传感器TT01 故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_044": {
- "name": "OC_CVTWaterCoolOutletTemp",
- "cn": "变频器水冷回水温度传感器TT02 故障",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_045": {
- "name": "OC_CVTWaterCoolInletPre",
- "cn": "变频器水冷供水压力变送器PT01 故障",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_046": {
- "name": "OC_CVTWaterCoolOutletPre",
- "cn": "变频器水冷回水压力变送器PT02 故障",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_047": {
- "name": "SC_CVTWaterCoolInletTempHigh2",
- "cn": "变频器水冷供水温度高故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_048": {
- "name": "OC_CVTWaterCoolInletTempHigh1",
- "cn": "变频器水冷供水温度高报警",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_05_049": {
- "name": "SC_CVTWaterCoolOutletTempHigh",
- "cn": "变频器水冷回水温度高",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_009": {
- "name": "SC_Sensor1RotorImpulsesDefect",
- "cn": "低速端#1接近开关故障",
- "subsystem": "Drivetrain",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_04_010": {
- "name": "SC_Sensor2RotorImpulsesDefect",
- "cn": "低速端#2接近开关故障",
- "subsystem": "Drivetrain",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1sec"
- ],
- "detectable_in_10min": false
- },
- "02_04_012": {
- "name": "SC_OverspeedRelayDetectFail",
- "cn": "低速端转速与过速继电器测速不匹配",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_001": {
- "name": "SC_TempNacelleCabinetOutOfSpec",
- "cn": "机舱柜恒温器测得温度高于设定值",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_003": {
- "name": "SC_NacelleUPS24VPLC_Alarm",
- "cn": "机舱柜24V UPS报警",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#15s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_004": {
- "name": "SC_TowerThermostatsProtBreak",
- "cn": "塔底温控器电源空开跳开",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": null,
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_005": {
- "name": "SC_NacelleThermostatsProtBreak",
- "cn": "机舱温控器电源空开跳开",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": null,
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_006": {
- "name": "SC_NacelleUPS24VPLC_BatteryMode",
- "cn": "机舱柜24V UPS处于电池模式",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_008": {
- "name": "SC_FaultOvervoltageProtectionCabinetNacelle",
- "cn": "机舱柜690V电源防雷器,机舱柜400V电源防雷器或塔底柜230V电源防雷器发生故障",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_020": {
- "name": "SC_NacelleFuse690VMainSupply",
- "cn": "机舱柜690V电源熔断器故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_021": {
- "name": "SC_NacelleFuse400VMainSupply",
- "cn": "机舱柜400V电源熔断器故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_026": {
- "name": "SC_NacelleFuseHeaterSlipring",
- "cn": "机舱柜中电气滑环加热器保护空开跳开",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_033": {
- "name": "SC_NacelleFuse230VCabClimatisation",
- "cn": "机舱柜加热器230V保护空开跳开",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_039": {
- "name": "SC_NacelleFuse400VAC_24VDC",
- "cn": "机舱柜中AC400V转DC24V电源模块的供电保护空开跳开",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_120": {
- "name": "OC_NacelleHeaterCabinetON",
- "cn": "机舱柜加热器设定打开",
- "subsystem": "Cabinet",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_02_129": {
- "name": "OC_Nacelle_24VPLC_BatteryCharge",
- "cn": "机舱柜中24V UPS处于充电模式",
- "subsystem": "Cabinet",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_12_002": {
- "name": "SC_TurbineInServiceNacelle",
- "cn": "机舱发出风机进入检修或变桨检修命令",
- "subsystem": "Cabinet",
- "level": "210-维护",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_12_006": {
- "name": "SC_ResetStatusCodesFromNacelleOrTowerBase",
- "cn": "机舱或塔底发出复位状态字命令",
- "subsystem": "Cabinet",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_001": {
- "name": "SC_TempTowerBaseCabinetOutOfSpec",
- "cn": "塔底柜恒温器测得温度高于设定值",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_004": {
- "name": "SC_TowerNHFuse690VMAINSupply",
- "cn": "塔底柜690V电源熔断器故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_006": {
- "name": "SC_FaultOvervoltageProtectionTowerBase",
- "cn": "塔底柜690V,400V或变频柜主电源防雷器故障",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_007": {
- "name": "SC_TowerNHFuse400VMainSupply",
- "cn": "塔底柜400V电源熔断器故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_011": {
- "name": "SC_TowerFuse230VCabClimatisation",
- "cn": "塔底柜加热器或散热风扇的230V电源保护空开跳开",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_034": {
- "name": "SC_TowerUPS24VPLC_Alarm",
- "cn": "塔底24V UPS报警",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_035": {
- "name": "SC_TowerUPS24VPLC_BatteryMode",
- "cn": "塔底24V UPS电池模式",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_036": {
- "name": "OC_TowerUPS24VPLC_BatteryCharge",
- "cn": "塔底24V UPS电池充电模式",
- "subsystem": "Cabinet",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_08_005": {
- "name": "SC_TurbineInRepairTowerBase",
- "cn": "塔底柜检修开关打开,要求风机进入检修模式",
- "subsystem": "Cabinet",
- "level": "220-维修",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "220",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_08_105": {
- "name": "SC_TowerBrakeForClimbingActivated",
- "cn": "塔底柜的攀爬开关打开,要求停机安全爬塔",
- "subsystem": "Cabinet",
- "level": "210-维护",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_001": {
- "name": "OC_CT_HeaterManualMode",
- "cn": "塔底控制柜加热器手动模式开启",
- "subsystem": "Cabinet",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "True",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_002": {
- "name": "OC_CT_HeaterForceMode",
- "cn": "塔底控制柜加热器强制模式开启",
- "subsystem": "Cabinet",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "True",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_003": {
- "name": "OC_CN_HeaterManualMode",
- "cn": "机舱控制柜加热器手动模式开启",
- "subsystem": "Cabinet",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "True",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_004": {
- "name": "OC_CN_HeaterForceMode",
- "cn": "机舱控制柜加热器强制模式开启",
- "subsystem": "Cabinet",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "True",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_040": {
- "name": "SC_TowerFuse24VMediaConvPlusBCSafetyChain",
- "cn": "塔底以太网交换器24V电源保险丝故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_100": {
- "name": "OC_TowerHeaterCabinet_ON",
- "cn": "塔底控制柜加热器打开",
- "subsystem": "Cabinet",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_02_109": {
- "name": "OC_ControlCabinetHeatingMode",
- "cn": "控制柜暖机模式",
- "subsystem": "Cabinet",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_02_110": {
- "name": "SC_CabinetHeatingModeTimeout",
- "cn": "控制柜暖机超时",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#30m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_03_001": {
- "name": "SC_TempTowerBase_high",
- "cn": "塔底温度过高警告",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_03_002": {
- "name": "SC_TempTowerBase_low",
- "cn": "塔底温度过低警告",
- "subsystem": "Cabinet",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#24h",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_03_003": {
- "name": "SC_TempTowerBase_MAX",
- "cn": "塔底温度过高故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_03_004": {
- "name": "SC_TempTowerBase_MIN",
- "cn": "塔底温度过低故障",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_10min"
- ],
- "detectable_in_10min": true
- },
- "03_03_007": {
- "name": "SC_RepFaultTempTowerBase",
- "cn": "塔底温度过高过低警告重复出现",
- "subsystem": "Cabinet",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_07_010": {
- "name": "SC_TowerDoorSwitchSignalOpen",
- "cn": "塔筒门被打开",
- "subsystem": "Cabinet",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_013": {
- "name": "SC_Blade1_PilotContactNotConnected",
- "cn": "1号电池柜航空插头没有插好",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_014": {
- "name": "SC_Blade1_DCLinkVoltageTooLow",
- "cn": "1号桨PM直流母线电压低",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_017": {
- "name": "SC_Blade1_CollectiveWarning",
- "cn": "1号桨的出现警报",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_018": {
- "name": "SC_Blade1_ErrorWithBatteryDrivenSTOP",
- "cn": "1号桨故障,触发电池驱动回桨",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_033": {
- "name": "SC_Blade2_PilotContactNotConnected",
- "cn": "2号电池柜航空插头没有插好",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_034": {
- "name": "SC_Blade2_DCLinkVoltageTooLow",
- "cn": "2号桨PM直流母线电压低",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_037": {
- "name": "SC_Blade2_CollectiveWarning",
- "cn": "2号桨的出现警报",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_038": {
- "name": "SC_Blade2_ErrorWithBatteryDrivenSTOP",
- "cn": "2号桨故障,触发电池驱动回桨",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_053": {
- "name": "SC_Blade3_PilotContactNotConnected",
- "cn": "3号电池柜航空插头没有插好",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_054": {
- "name": "SC_Blade3_DCLinkVoltageTooLow",
- "cn": "3号桨PM直流母线电压低",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_057": {
- "name": "SC_Blade3_CollectiveWarning",
- "cn": "3号桨的出现警报",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_058": {
- "name": "SC_Blade3_ErrorWithBatteryDrivenSTOP",
- "cn": "3号桨故障,触发电池驱动回桨",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_061": {
- "name": "SC_PitchSystem24VTripped",
- "cn": "变桨系统24V电源故障",
- "subsystem": "pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5.1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_062": {
- "name": "SC_ErrorBatteryChargerAxis1or2or3",
- "cn": "变桨系统电池充电回路故障",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForBatteryChargerFault",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_069": {
- "name": "SC_Pitch_CollectiveFaultMessage",
- "cn": "变桨系统发生2级故障",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5.1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_070": {
- "name": "SC_Pitch_ErrorWithBatteryDrivenSTOP",
- "cn": "变桨系统与主控系统的Profibus通讯或与PM的CAN通讯出现故障",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForCANProfibus",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_076": {
- "name": "SC_Pitch_CollectiveWarning",
- "cn": "变桨系统出现警告",
- "subsystem": "Pitchsystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_077": {
- "name": "SC_Pitch_MainsFailure",
- "cn": "变桨系统400V电网存在故障",
- "subsystem": "Pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#5s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_100": {
- "name": "SC_Blade3_OvertempStartResistorAxis1or2or3",
- "cn": "1号,2号或3号桨报告预充电电阻过温",
- "subsystem": "pitchsystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_104": {
- "name": "SC_Pitch_CANBusError",
- "cn": "变桨系统与PM的CAN通讯故障",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForCANProfibus",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_106": {
- "name": "SC_Pitch_MotorEncIncoherence",
- "cn": "变桨系统报告桨叶间角度相差过大(相差2度持续120毫秒)",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tSetDelayForCANProfibus",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "198",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_107": {
- "name": "OC_PitchMaintenanceMode",
- "cn": "变桨系统处于维护模式",
- "subsystem": "Pitchsystem",
- "level": "210-维护",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "210",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "01_05_109": {
- "name": "OC_PitchHeatingMode",
- "cn": "变桨系统暖机模式",
- "subsystem": "PitchSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "50",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": [
- "_1min"
- ],
- "detectable_in_10min": false
- },
- "01_05_110": {
- "name": "SC_PitchHeatingModeTimeout",
- "cn": "变桨系统暖机超时",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#30m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_030": {
- "name": "SC_SELFTEST_PitchAccumulatorStatusError1",
- "cn": "桨叶1电池自检失败",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tSELFTEST_PitchBatteryStatusError",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_031": {
- "name": "SC_SELFTEST_PitchAccumulatorStatusError2",
- "cn": "桨叶2电池自检失败",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tSELFTEST_PitchBatteryStatusError",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_032": {
- "name": "SC_SELFTEST_PitchAccumulatorStatusError3",
- "cn": "桨叶3电池自检失败",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tSELFTEST_PitchBatteryStatusError",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_117": {
- "name": "SC_TimeOutPitch2SelfTest",
- "cn": "桨叶2电池自检超时",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#50s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_118": {
- "name": "SC_TimeOutPitch3SelfTest",
- "cn": "桨叶3电池自检超时",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#50s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_09_116": {
- "name": "SC_TimeOutPitch1SelfTest",
- "cn": "桨叶1电池自检超时",
- "subsystem": "PitchSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#50s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_019": {
- "name": "OC_ConverterSpeedModeSwitchedOn",
- "cn": "变频器转速模式开启",
- "subsystem": "ConverterContainer",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_020": {
- "name": "OC_ConverterServiceSwichedOn",
- "cn": "变频器Service功能开启",
- "subsystem": "ConverterContainer",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "220",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_021": {
- "name": "SC_Converter_MCBCloseTimeout",
- "cn": "变频器合主断路器超时",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tCVT_MCBCloseTimeout",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_022": {
- "name": "SC_CVT_LVRT_Timeout",
- "cn": "变频器LVRT超时",
- "subsystem": "ConverterContainer",
- "level": "",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tCVT_LVRT_Timeout",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_023": {
- "name": "SC_CVT_IGBT_TempHigh",
- "cn": "IGBT温度高报警",
- "subsystem": "ConverterContainer",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_024": {
- "name": "SC_CVT_IGBT_TempVeryHigh",
- "cn": "IGBT温度高故障",
- "subsystem": "ConverterContainer",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_025": {
- "name": "OC_ConverterHeatingModeOn",
- "cn": "变频器暖机模式",
- "subsystem": "ConverterContainer",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_026": {
- "name": "SC_CVT_MinInterval_TwiceCharge_Waiting",
- "cn": "变频器两次充电最短时间间隔等待中",
- "subsystem": "ConverterContainer",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_027": {
- "name": "SC_FaultInput_CVT_Humidity",
- "cn": "变频器湿度传感器故障",
- "subsystem": "ConverterContainer",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_035": {
- "name": "SC_Transformer_Temp_Sensor_Fault",
- "cn": "变压器温度传感器失效",
- "subsystem": "GCC",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_036": {
- "name": "SC_Transformer_Temp_High_Alarm",
- "cn": "变压器温度过高警告",
- "subsystem": "GCC",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_037": {
- "name": "SC_Transformer_Temp_Winding_different",
- "cn": "变压器不同绕组温差过大",
- "subsystem": "GCC",
- "level": "",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_038": {
- "name": "SC_Transformer_Temp_No_reading",
- "cn": "变压器温度值无读数",
- "subsystem": "GCC",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_039": {
- "name": "SC_Transformer_WaterLeak",
- "cn": "变压器水泄漏",
- "subsystem": "GCC",
- "level": "",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_040": {
- "name": "SC_Transformer_Door_Open",
- "cn": "变压器柜门打开",
- "subsystem": "GCC",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_041": {
- "name": "SC_Transformer_Cooling_Motor_Not_running",
- "cn": "变压器冷却风扇没有运行",
- "subsystem": "GCC",
- "level": "",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_042": {
- "name": "SC_FaultPT100_GCC_Temp2",
- "cn": "变压器环境温度PT100故障",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_043": {
- "name": "SC_UPS_Bypass",
- "cn": "UPS被旁路",
- "subsystem": "GCC",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_006": {
- "name": "SC_TowerToNacelle690PowerSupplyOff",
- "cn": "塔底到机舱690V供电MCB跳开",
- "subsystem": "Cabinet",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_007": {
- "name": "SC_TowerToNacelle400PowerSupplyOff",
- "cn": "塔底到机舱400V供电MCB跳开",
- "subsystem": "Cabinet",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_008": {
- "name": "SC_AUXTransformer690PowerSupplyOff",
- "cn": "控制柜与变压器间690V MCB跳开",
- "subsystem": "Cabinet",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_009": {
- "name": "SC_AUXTransformer400PowerSupplyOff",
- "cn": "控制柜与变压器间400V MCB跳开",
- "subsystem": "Cabinet",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_140": {
- "name": "SC_Blade1PositionCheckFault",
- "cn": "1号桨叶角度检查偏差过大故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_141": {
- "name": "SC_Blade2PositionCheckFault",
- "cn": "2号桨叶角度检查偏差过大故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_142": {
- "name": "SC_Blade3PositionCheckFault",
- "cn": "3号桨叶角度检查偏差过大故障",
- "subsystem": "PitchSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_011": {
- "name": "SC_Selftest5_OK",
- "cn": "自检5完成结果正常",
- "subsystem": "TurbineStateMachine",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_012": {
- "name": "SC_Selftest5_Warning",
- "cn": "自检5完成结果报警",
- "subsystem": "TurbineStateMachine",
- "level": "",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_013": {
- "name": "SC_TowerFrequency_OK",
- "cn": "塔筒频率连续监测结果正常",
- "subsystem": "TurbineStateMachine",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_014": {
- "name": "SC_TowerFrequencyTest_Warning",
- "cn": "塔筒频率连续监测结果报警",
- "subsystem": "TurbineStateMachine",
- "level": "",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_015": {
- "name": "SC_Selftest5_Timeout",
- "cn": "自检5运行超时",
- "subsystem": "TurbineStateMachine",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "PAR_tTimeoutSelftest5",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_037": {
- "name": "SC_PCHFault",
- "cn": "PCH出现异常",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_038": {
- "name": "OC_SwitchPCHToGJSensor",
- "cn": "振动检测由PCH切换到G&J传感器",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_039": {
- "name": "SC_GJSensorFault",
- "cn": "G&J传感器出现异常",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_040": {
- "name": "SC_BothVibrationSensorFault",
- "cn": "PCH与G&J传感器同时出现异常",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#30s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_041": {
- "name": "SC_VibrationOmniDirectionLevel1_GJ",
- "cn": "G&J检测到塔架水平方向的加速度高于1级振动门限值",
- "subsystem": "NacelleSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#2s",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "51",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_042": {
- "name": "SC_VibrationOmniDirectionLevel2_GJ",
- "cn": "G&J检测到塔架水平方向的加速度高于2级振动门限值",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#2s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_043": {
- "name": "SC_RepFaultVibrationXAxis_GJ",
- "cn": "阵风过大保护性停机",
- "subsystem": "NacelleSystem",
- "level": "139-大风停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "139",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_044": {
- "name": "SC_VibrationForeaftDirection1_GJ",
- "cn": "G&J检测到塔架前后方向的加速度高于1级振动门限值",
- "subsystem": "NacelleSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#2s",
- "powerup_delay": "T#0s",
- "repeat_n": "3",
- "repeat_period": "T#1h",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_045": {
- "name": "SC_VibrationForeaftDirection2_GJ",
- "cn": "G&J检测到塔架前后方向的加速度高于2级振动门限值",
- "subsystem": "NacelleSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#2s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_046": {
- "name": "SC_RepFaultVibrationYAxis_GJ",
- "cn": "阵风过大保护性停机",
- "subsystem": "NacelleSystem",
- "level": "139-大风停机",
- "reset_mode": "M",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "139",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_047": {
- "name": "OC_VibrationOmniDirection_GJ",
- "cn": "塔架水平方向的加速度超限",
- "subsystem": "NacelleSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_048": {
- "name": "OC_VibrationForeaftDirection_GJ",
- "cn": "塔架前后方向的加速度超限",
- "subsystem": "NacelleSystem",
- "level": "30-待机",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "30",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_049": {
- "name": "SC_BlockYawForVibrationHigh_GJ",
- "cn": "G&J传感器检测到前后方向振动值过大禁止偏航一分钟",
- "subsystem": "NacelleSystem",
- "level": "10-其他",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_016": {
- "name": "SC_SafetyChain_SSDSwitch_GJ",
- "cn": "G&J传感器测得的SSD震动值高于设定值",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#15s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_017": {
- "name": "SC_SafetyChain_SSDMax_GJ",
- "cn": "G&J的SSD开关断开导致安全链断开",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#30s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_018": {
- "name": "SC_SafetyChain_VibrationSwitch_GJ",
- "cn": "G&J的振动过大继电器断开导致安全链断开",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#15s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_019": {
- "name": "SC_VibrationRelayActive_GJ",
- "cn": "G&J振动过大继电器触发",
- "subsystem": "SafetySystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_015": {
- "name": "SC_MainShaftCrack",
- "cn": "主轴两端转速差过大判断主轴断裂",
- "subsystem": "Drivetrain",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1m",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "200",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_028": {
- "name": "SC_TCS_Pump1_Overload",
- "cn": "塔底水冷泵1过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": null,
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_029": {
- "name": "SC_TCS_Pump2_Overload",
- "cn": "塔底水冷泵2过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": null,
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_030": {
- "name": "SC_TCS_Pumps_Overload",
- "cn": "塔底水冷泵全部过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": null,
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_031": {
- "name": "SC_TCS_Pump1_MCB",
- "cn": "塔底水冷泵1MCB跳开",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_032": {
- "name": "SC_TCS_Pump2_MCB",
- "cn": "塔底水冷泵2MCB跳开",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_033": {
- "name": "SC_TCS_Pumps_MCB",
- "cn": "塔底水冷泵MCB全部跳开",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_034": {
- "name": "SC_TCSPump1Failure_NoPressure",
- "cn": "塔底水冷泵1无压力故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_035": {
- "name": "SC_TCSPump2Failure_NoPressure",
- "cn": "塔底水冷泵2无压力故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#10s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_036": {
- "name": "SC_TCS_Heater_Overload",
- "cn": "塔底水冷加热器过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": null,
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_037": {
- "name": "SC_TCS_Heater_MCB",
- "cn": "塔底水冷加热器MCB跳开",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_038": {
- "name": "SC_TCS_InletWaterTempLow_Warning",
- "cn": "塔底水冷进水口水温过低警告",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_039": {
- "name": "SC_TCS_InletWaterPT100Fault",
- "cn": "塔底水冷进水口PT100故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_040": {
- "name": "SC_TCS_InsideFan1_Overload",
- "cn": "塔底水冷塔内风扇1过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": null,
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_041": {
- "name": "SC_TCS_InsideFan2_Overload",
- "cn": "塔底水冷塔内风扇2过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": null,
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_042": {
- "name": "SC_TCS_InsideFan1_MCB",
- "cn": "塔底水冷塔内风扇1MCB跳开",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_043": {
- "name": "SC_TCS_InsideFan2_MCB",
- "cn": "塔底水冷塔内风扇2MCB跳开",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_044": {
- "name": "SC_TCS_TowerTempHigh",
- "cn": "塔内温度高警告",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_045": {
- "name": "SC_TCS_TowerTempTooHigh",
- "cn": "塔内温度过高停机",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_046": {
- "name": "SC_TCS_Cooler1FanA_Overload",
- "cn": "塔底冷却器1风扇A过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_047": {
- "name": "SC_TCS_Cooler1FanB_Overload",
- "cn": "塔底冷却器1风扇B过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_048": {
- "name": "SC_TCS_Cooler2FanA_Overload",
- "cn": "塔底冷却器2风扇A过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_049": {
- "name": "SC_TCS_Cooler2FanB_Overload",
- "cn": "塔底冷却器2风扇B过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_050": {
- "name": "SC_TCS_Cooler3FanA_Overload",
- "cn": "塔底冷却器3风扇A过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_051": {
- "name": "SC_TCS_Cooler3FanB_Overload",
- "cn": "塔底冷却器3风扇B过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_052": {
- "name": "SC_TCS_Cooler4FanA_Overload",
- "cn": "塔底冷却器4风扇A过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_053": {
- "name": "SC_TCS_Cooler4FanB_Overload",
- "cn": "塔底冷却器4风扇B过载",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_054": {
- "name": "SC_TCS_Cooler1Fans_MCB",
- "cn": "塔底冷却器1风扇 MCB跳开",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_055": {
- "name": "SC_TCS_Cooler2Fans_MCB",
- "cn": "塔底冷却器2风扇 MCB跳开",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_056": {
- "name": "SC_TCS_Cooler3Fans_MCB",
- "cn": "塔底冷却器3风扇 MCB跳开",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_057": {
- "name": "SC_TCS_Cooler4Fans_MCB",
- "cn": "塔底冷却器4风扇 MCB跳开",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_058": {
- "name": "SC_TCSWaterPressureTooLow",
- "cn": "塔底水冷水压力过低故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_059": {
- "name": "OC_TCS_Pump1_ON",
- "cn": "塔底水冷泵1启动",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_060": {
- "name": "OC_TCS_Pump2_ON",
- "cn": "塔底水冷泵2启动",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_061": {
- "name": "OC_TCS_Heater_ON",
- "cn": "塔底水冷加热器启动",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_062": {
- "name": "SC_TCS_CVTOutletPT100Fault",
- "cn": "塔底水冷变频器出口PT100故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_063": {
- "name": "SC_TCS_TrafoOutletPT100Fault",
- "cn": "塔底水冷变压器出口PT100故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_064": {
- "name": "SC_TCS_OutletPT100Fault",
- "cn": "塔底水冷被冷却器出口PT100故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_065": {
- "name": "SC_TCS_InsideCoolerInletPT100Fault",
- "cn": "塔底水冷塔内冷却器入口PT100故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_066": {
- "name": "SC_TCS_PumpManualMode",
- "cn": "塔底水冷泵开启手动模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_067": {
- "name": "SC_TCS_PumpForceMode",
- "cn": "塔底水冷泵开启强制模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_068": {
- "name": "SC_TCS_FanManualMode",
- "cn": "塔底水冷系统中有风扇开启了手动模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_069": {
- "name": "SC_TCS_FanForceMode",
- "cn": "塔底水冷系统中有风扇开启了强制模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_070": {
- "name": "SC_TCS_HeaterManualMode",
- "cn": "塔底水冷加热器开启手动模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_071": {
- "name": "SC_TCS_HeaterForceMode",
- "cn": "塔底水冷加热器开启强制模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_072": {
- "name": "SC_TCS_MixingValveManualMode",
- "cn": "塔底水冷三通阀开启手动模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_073": {
- "name": "SC_TCS_MixingValveForceMode",
- "cn": "塔底水冷加热器开启强制模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_074": {
- "name": "SC_TCS_PumpInletPreSensorFault",
- "cn": "塔底水冷泵吸入侧压力传感器故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_075": {
- "name": "SC_TCS_PumpOutletPreSensorFault",
- "cn": "塔底水冷泵压力侧压力传感器故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_076": {
- "name": "SC_TCS_PumpOffAbnormally",
- "cn": "塔底水冷泵需启动但未启动",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#100ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_044": {
- "name": "SC_FaultPT100_GCC_Temp3",
- "cn": "变压器底部温度传感器1故障",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_11_045": {
- "name": "SC_FaultPT100_GCC_Temp4",
- "cn": "变压器底部温度传感器2故障",
- "subsystem": "GCC",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_077": {
- "name": "SC_FaultOutsideTowerHumidity",
- "cn": "塔筒外湿度传感器故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_078": {
- "name": "SC_FaultCabinetFloorHumidity",
- "cn": "塔底控制柜底部湿度传感器故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_079": {
- "name": "SC_FaultMixingValvePosition",
- "cn": "塔底水冷系统三通阀位置传感器故障",
- "subsystem": "CoolingSystem",
- "level": "170-故障停机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "True",
- "set_delay": "T#10ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "100",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_080": {
- "name": "SC_CCC_Temp_MAX",
- "cn": "塔底水冷控制柜温度高故障",
- "subsystem": "CoolingSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_081": {
- "name": "SC_CCC_Temp_MIN",
- "cn": "塔底水冷控制柜温度低故障",
- "subsystem": "CoolingSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_082": {
- "name": "SC_CCC_Temp_High",
- "cn": "塔底水冷控制柜温度高警告",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_083": {
- "name": "SC_CCC_Temp_Low",
- "cn": "塔底水冷控制柜温度低警告",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_084": {
- "name": "SC_CCC_690VSupplyTripped",
- "cn": "塔底水冷系统690V供电跳开",
- "subsystem": "CoolingSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_085": {
- "name": "SC_CCC_NoUPS230VSupplyTripped",
- "cn": "塔底水冷系统230V(无UPS)供电跳开",
- "subsystem": "CoolingSystem",
- "level": "170-故障停机",
- "reset_mode": "M",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#1s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_086": {
- "name": "SC_CCC_HeaterOrCoolerPowerTripped",
- "cn": "塔底水冷控制柜加热器或冷却器供电跳开",
- "subsystem": "CoolingSystem",
- "level": "40-警告待机",
- "reset_mode": "A",
- "type": "A",
- "alarm": "False",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "40",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_087": {
- "name": "SC_CCC_FaultPT100Temp",
- "cn": "塔底水冷控制柜PT100故障",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "F",
- "alarm": "True",
- "set_delay": "T#0s",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "51",
- "bp_runtime_2015": "170",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_088": {
- "name": "SC_CCC_HeaterManualMode",
- "cn": "塔底水冷控制柜加热器进入手动模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_089": {
- "name": "SC_CCC_HeaterForceMode",
- "cn": "塔底水冷控制柜加热器进入强制模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_090": {
- "name": "SC_CCC_CoolerManualMode",
- "cn": "塔底水冷控制柜风扇进入手动模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_091": {
- "name": "SC_CCC_CoolerForceMode",
- "cn": "塔底水冷控制柜风扇进入强制模式",
- "subsystem": "CoolingSystem",
- "level": "",
- "reset_mode": "A",
- "type": "I",
- "alarm": "False",
- "set_delay": "T#50ms",
- "powerup_delay": "T#0s",
- "repeat_n": "0",
- "repeat_period": "T#0s",
- "brake_state_design": "0",
- "bp_runtime_2015": "10",
- "src": "plc_dict_2014",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_01_009": {
- "name": null,
- "cn": "变桨系统的400V主接触器未闭合",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_033": {
- "name": null,
- "cn": "塔架Z方向的瞬时加速度越限",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_04_036": {
- "name": null,
- "cn": "塔架Z方向的瞬时加速度告警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_08_010": {
- "name": null,
- "cn": "变频器测得发电机功率高于过高设定值",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "02_09_034": {
- "name": null,
- "cn": "高速液压刹车未释放",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "03_01_011": {
- "name": null,
- "cn": "风机保护性停机——自恢复执行中",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "185",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_020": {
- "name": null,
- "cn": "变频器急停按钮被拍下触发紧急停机",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_021": {
- "name": null,
- "cn": "机舱柜安全链回路24V保护空开跳开",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_022": {
- "name": null,
- "cn": "偏航黄盒子终极限位触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_023": {
- "name": null,
- "cn": "安全控制器测得低速端编码器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "175",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_01_024": {
- "name": null,
- "cn": "安全控制器测得高速端接近开关故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "175",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_143": {
- "name": null,
- "cn": "变桨超级电容正在充电",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "30",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_144": {
- "name": null,
- "cn": "变桨系统通信中断频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_145": {
- "name": null,
- "cn": "自复位变桨通信故障失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_146": {
- "name": null,
- "cn": "复位EL6751操作中",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "230",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_147": {
- "name": null,
- "cn": "变桨系统与主控的通讯故障频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_148": {
- "name": null,
- "cn": "变桨系统与主控的通讯故障自动复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_149": {
- "name": null,
- "cn": "1号轴控柜温度过高故障频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_150": {
- "name": null,
- "cn": "1号轴控柜温度过高故障自动复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_151": {
- "name": null,
- "cn": "2号轴控柜温度过高故障频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_152": {
- "name": null,
- "cn": "2号轴控柜温度过高故障自动复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_153": {
- "name": null,
- "cn": "3号轴控柜温度过高故障频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_154": {
- "name": null,
- "cn": "3号轴控柜温度过高故障自动复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_155": {
- "name": null,
- "cn": "1号变桨电机温度过高故障频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_156": {
- "name": null,
- "cn": "1号变桨电机温度过高故障自动复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_157": {
- "name": null,
- "cn": "2号变桨电机温度过高故障频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_158": {
- "name": null,
- "cn": "2号变桨电机温度过高故障自动复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_159": {
- "name": null,
- "cn": "3号变桨电机温度过高故障频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_160": {
- "name": null,
- "cn": "3号变桨电机温度过高故障自动复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_161": {
- "name": null,
- "cn": "1号后备电源柜温度过高故障频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_162": {
- "name": null,
- "cn": "1号后备电源柜温度过高故障自动复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_163": {
- "name": null,
- "cn": "2号后备电源柜温度过高故障频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_164": {
- "name": null,
- "cn": "2号后备电源柜温度过高故障自动复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_165": {
- "name": null,
- "cn": "3号后备电源柜温度过高故障频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_166": {
- "name": null,
- "cn": "3号后备电源柜温度过高故障自动复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_167": {
- "name": null,
- "cn": "中心柜温度过高故障频繁触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_02_168": {
- "name": null,
- "cn": "中心柜温度过高故障自动复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_016": {
- "name": null,
- "cn": "高速端转速IIR滤波后RMS值报警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_017": {
- "name": null,
- "cn": "高速端转速IIR滤波后RMS值停机",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_018": {
- "name": null,
- "cn": "高速端转速IIR滤波后RMS值报警重复出现",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_019": {
- "name": null,
- "cn": "低速端转速IIR滤波后RMS值报警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_020": {
- "name": null,
- "cn": "低速端转速IIR滤波后RMS值停机",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_021": {
- "name": null,
- "cn": "低速端转速IIR滤波后RMS值报警重复出现",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_022": {
- "name": null,
- "cn": "传动链频率检测正常",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_023": {
- "name": null,
- "cn": "传动链频率检测异常",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_024": {
- "name": null,
- "cn": "高速端转速的STD异常停机",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_025": {
- "name": null,
- "cn": "低速端转速的STD异常停机",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_026": {
- "name": null,
- "cn": "主轴承润滑MCB跳开",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_027": {
- "name": null,
- "cn": "主轴承润滑系统启动",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_028": {
- "name": null,
- "cn": "主轴承润滑系统加热器MCB跳开",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_029": {
- "name": null,
- "cn": "主轴承润滑系统加热器启动",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_030": {
- "name": null,
- "cn": "主轴承润滑系统未运行超过一星期",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_031": {
- "name": null,
- "cn": "主轴润滑泵开启手动模式",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_032": {
- "name": null,
- "cn": "主轴润滑泵开启强制模式",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_033": {
- "name": null,
- "cn": "主轴润滑泵加热器开启手动模式",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_034": {
- "name": null,
- "cn": "主轴润滑泵加热器开启强制模式",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_035": {
- "name": null,
- "cn": "低速端转速与发电机转速不匹配复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_036": {
- "name": null,
- "cn": "低速端转速与发电机转速不匹配重复出现",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_037": {
- "name": null,
- "cn": "主控系统测得的发电机转速与从变频器读得的不匹配复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_038": {
- "name": null,
- "cn": "主控系统测得的发电机转速与从变频器读得的不匹配重复出现",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_039": {
- "name": null,
- "cn": "低速端转速与发电机转速十分钟平均值不匹配",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_040": {
- "name": null,
- "cn": "低速端转速高于1级超速门限值复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_04_041": {
- "name": null,
- "cn": "发电机转速高于1级超速门限值复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_048": {
- "name": null,
- "cn": "齿轮箱弹性支撑达到极限载荷报警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_049": {
- "name": null,
- "cn": "齿轮箱弹性支撑失效报警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_050": {
- "name": null,
- "cn": "齿轮箱左扭力臂位置传感器损坏",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_051": {
- "name": null,
- "cn": "齿轮箱右扭力臂位置传感器损坏",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_05_052": {
- "name": null,
- "cn": "齿轮箱油泵过滤器滤网堵塞停机故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_092": {
- "name": null,
- "cn": "塔底水冷系统三通阀MCB跳开",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_093": {
- "name": null,
- "cn": "塔底水冷进水口水温过低故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_094": {
- "name": null,
- "cn": "塔底水冷三通阀实际位置与设置值不匹配",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_095": {
- "name": null,
- "cn": "塔底水冷塔内风扇1启动",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_096": {
- "name": null,
- "cn": "塔底水冷塔内风扇2启动",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_097": {
- "name": null,
- "cn": "塔底水冷塔外冷却器1风扇启动",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_098": {
- "name": null,
- "cn": "塔底水冷塔外冷却器2风扇启动",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_099": {
- "name": null,
- "cn": "塔底水冷塔外冷却器3风扇启动",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_100": {
- "name": null,
- "cn": "塔底水冷塔外冷却器4风扇启动",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_101": {
- "name": null,
- "cn": "机舱冷却系统有漏液风险",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_102": {
- "name": null,
- "cn": "塔底冷却系统有漏液风险",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_103": {
- "name": null,
- "cn": "机舱冷却系统泵1启动压差低报警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_104": {
- "name": null,
- "cn": "机舱冷却系统泵2启动压差低报警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_105": {
- "name": null,
- "cn": "塔底冷却系统泵出口压力过高警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_106": {
- "name": null,
- "cn": "塔底水冷进水口水温过低故障自复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_107": {
- "name": null,
- "cn": "塔底水冷进水口水温过低故障重复出现",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_108": {
- "name": null,
- "cn": "机舱水冷系统水冷泵站需启动但未启动",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_08_110": {
- "name": null,
- "cn": "塔底水冷控制柜温度过高或过低警告重复出现",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_050": {
- "name": null,
- "cn": "机舱前后振动带通滤波值报警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_051": {
- "name": null,
- "cn": "机舱前后振动带通滤波值停机",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_052": {
- "name": null,
- "cn": "机舱前后振动带通滤波值报警重复出现",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_053": {
- "name": null,
- "cn": "机舱左右振动带通滤波值报警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_054": {
- "name": null,
- "cn": "机舱左右振动带通滤波值停机",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_055": {
- "name": null,
- "cn": "机舱左右振动带通滤波值报警重复出现",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_056": {
- "name": null,
- "cn": "叶片面内振动超限报警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_057": {
- "name": null,
- "cn": "风轮不平衡报警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_060": {
- "name": null,
- "cn": "切换至备用风速仪",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_061": {
- "name": null,
- "cn": "PCH的通讯状态为\"Node not found\"",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_09_062": {
- "name": null,
- "cn": "发送重启PCH信号",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_015": {
- "name": null,
- "cn": "偏航摩擦片润滑系统(2L)油脂底",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_016": {
- "name": null,
- "cn": "偏航摩擦片润滑系统(2L)堵塞",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_017": {
- "name": null,
- "cn": "偏航传感器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_018": {
- "name": null,
- "cn": "偏航速度异常,不在有效区间内",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_10_019": {
- "name": null,
- "cn": "偏航速度计算自检",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_028": {
- "name": null,
- "cn": "变频器EtherCAT通讯故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_029": {
- "name": null,
- "cn": "变频器双通道同步故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_030": {
- "name": null,
- "cn": "变频器Fastlink故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_031": {
- "name": null,
- "cn": "变频器Watchdog错误",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_032": {
- "name": null,
- "cn": "变频器FaultLoop故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_033": {
- "name": null,
- "cn": "变频器I2TFault",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_034": {
- "name": null,
- "cn": "变频器sharing故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_035": {
- "name": null,
- "cn": "变频器DB故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_036": {
- "name": null,
- "cn": "变频器水冷故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_037": {
- "name": null,
- "cn": "变频器烟感报警",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_038": {
- "name": null,
- "cn": "变频器主CB故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_039": {
- "name": null,
- "cn": "变频器机侧CB故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_040": {
- "name": null,
- "cn": "变频器主PWM滤波器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_041": {
- "name": null,
- "cn": "变频器预充电回路故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_042": {
- "name": null,
- "cn": "变频器网侧DIBe1故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_043": {
- "name": null,
- "cn": "变频器网侧DIBe2故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_044": {
- "name": null,
- "cn": "变频器网侧DIBe3故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_045": {
- "name": null,
- "cn": "变频器网侧DIBe4故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_046": {
- "name": null,
- "cn": "变频器机侧DIBe1故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_047": {
- "name": null,
- "cn": "变频器机侧DIBe2故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_048": {
- "name": null,
- "cn": "变频器机侧DIBe3故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_049": {
- "name": null,
- "cn": "变频器机侧DIBe4故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_050": {
- "name": null,
- "cn": "变频器报直流母线故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_051": {
- "name": null,
- "cn": "变频器PIBe故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_052": {
- "name": null,
- "cn": "变频器机侧防雷故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_053": {
- "name": null,
- "cn": "变频器报电机相关故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_054": {
- "name": null,
- "cn": "变频器报电网相关故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_055": {
- "name": null,
- "cn": "变频器报编码器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_056": {
- "name": null,
- "cn": "变频器固件不匹配",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_057": {
- "name": null,
- "cn": "变频器报过速故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_058": {
- "name": null,
- "cn": "变频器电机控制故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_059": {
- "name": null,
- "cn": "变频器报急停",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_060": {
- "name": null,
- "cn": "变频器电压检测板故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_061": {
- "name": null,
- "cn": "变频器机侧熔丝故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_062": {
- "name": null,
- "cn": "变频器报告警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_063": {
- "name": null,
- "cn": "变频器CAN通讯闪断",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_064": {
- "name": null,
- "cn": "变频器CAN通讯长断",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "50",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_065": {
- "name": null,
- "cn": "变频器CAN通讯闪断重复触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "175",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_066": {
- "name": null,
- "cn": "变频器CAN通讯自复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "175",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_067": {
- "name": null,
- "cn": "变频器CAN通讯长断重复触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "175",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_068": {
- "name": null,
- "cn": "变频柜空调电源故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_069": {
- "name": null,
- "cn": "变频器直流母线充电超时重复触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "175",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_070": {
- "name": null,
- "cn": "变频器直流母线充电超时自复位失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "175",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_071": {
- "name": null,
- "cn": "主从配置正在进行",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_072": {
- "name": null,
- "cn": "GEPC变频器报告警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_073": {
- "name": null,
- "cn": "变频器报告警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_074": {
- "name": null,
- "cn": "变频器报告冷却故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_075": {
- "name": null,
- "cn": "扭矩设定值与真实值的偏差过大",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_076": {
- "name": null,
- "cn": "变频器SDO通讯超时",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_101": {
- "name": null,
- "cn": "ABB变频器机侧IGBT故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_102": {
- "name": null,
- "cn": "ABB变频器机侧模块故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_103": {
- "name": null,
- "cn": "ABB变频器机侧电流异常故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_104": {
- "name": null,
- "cn": "ABB变频器直流母线故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_105": {
- "name": null,
- "cn": "ABB变频器充电回路故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_106": {
- "name": null,
- "cn": "ABB变频器机侧控制器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_107": {
- "name": null,
- "cn": "ABB变频器LSU故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_108": {
- "name": null,
- "cn": "ABB变频器LSU风扇故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_109": {
- "name": null,
- "cn": "ABB变频器冷却系统故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_110": {
- "name": null,
- "cn": "ABB变频器风扇故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_111": {
- "name": null,
- "cn": "ABB变频器机侧模块风扇故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_112": {
- "name": null,
- "cn": "ABB变频器机侧模块通讯故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_113": {
- "name": null,
- "cn": "ABB变频器机侧EFB故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_114": {
- "name": null,
- "cn": "ABB变频器机侧通讯故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_115": {
- "name": null,
- "cn": "ABB变频器电机侧故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_116": {
- "name": null,
- "cn": "ABB变频器变频器温度故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_117": {
- "name": null,
- "cn": "ABB变频器STO故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_118": {
- "name": null,
- "cn": "ABB变频器测量监控信号故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_119": {
- "name": null,
- "cn": "ABB变频器动态刹车故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_120": {
- "name": null,
- "cn": "ABB变频器机械刹车故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_121": {
- "name": null,
- "cn": "ABB变频器急停信号异常故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_122": {
- "name": null,
- "cn": "ABB变频器转速信号故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_123": {
- "name": null,
- "cn": "ABB变频器FSO故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_124": {
- "name": null,
- "cn": "ABB变频器机侧电缆异常故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_125": {
- "name": null,
- "cn": "ABB变频器其他故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_126": {
- "name": null,
- "cn": "ABB变频器机侧外部故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_127": {
- "name": null,
- "cn": "ABB变频器网侧IGBT故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_128": {
- "name": null,
- "cn": "ABB变频器网侧模块故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_129": {
- "name": null,
- "cn": "ABB变频器网侧电流故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_130": {
- "name": null,
- "cn": "ABB变频器电网故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_131": {
- "name": null,
- "cn": "ABB变频器网侧控制器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_132": {
- "name": null,
- "cn": "ABB变频器网侧模块通讯故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_133": {
- "name": null,
- "cn": "ABB变频器EFB通讯故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_134": {
- "name": null,
- "cn": "ABB变频器网侧通讯故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_135": {
- "name": null,
- "cn": "ABB变频器网侧外部故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_136": {
- "name": null,
- "cn": "ABB变频器网侧电缆异常故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_137": {
- "name": null,
- "cn": "ABB变频器断路器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_138": {
- "name": null,
- "cn": "ABB变频器水冷系统故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_139": {
- "name": null,
- "cn": "ABB变频器故障停机",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_12_140": {
- "name": null,
- "cn": "ABB变频器未拆分故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_010": {
- "name": null,
- "cn": "塔底控制柜左侧温度传感器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_011": {
- "name": null,
- "cn": "塔底控制柜右侧温度传感器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_012": {
- "name": null,
- "cn": "塔底690V防雷器触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_013": {
- "name": null,
- "cn": "塔底400V防雷器触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_014": {
- "name": null,
- "cn": "塔底230V防雷器触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_015": {
- "name": null,
- "cn": "机舱690V防雷器触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_016": {
- "name": null,
- "cn": "机舱400V防雷器触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_017": {
- "name": null,
- "cn": "机舱230V防雷器触发",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_018": {
- "name": null,
- "cn": "塔底柜24V电源冗余失效",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_019": {
- "name": null,
- "cn": "机舱柜24V电源冗余失效",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_020": {
- "name": null,
- "cn": "塔底柜左侧加热器与通风风扇230V供电开关断开",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_021": {
- "name": null,
- "cn": "塔底柜右侧加热器与冷却风扇230V供电开关断开",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_022": {
- "name": null,
- "cn": "机舱柜通风风扇230V供电开关断开",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_023": {
- "name": null,
- "cn": "机舱柜加热器230V供电开关断开",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_13_024": {
- "name": null,
- "cn": "风机尚有问题禁止离开",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_020": {
- "name": null,
- "cn": "IPC45度传感器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_021": {
- "name": null,
- "cn": "IPC135度传感器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_022": {
- "name": null,
- "cn": "IPC225度传感器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_15_023": {
- "name": null,
- "cn": "IPC315度传感器故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_16_016": {
- "name": null,
- "cn": "启动模式运行超时重复",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_038": {
- "name": null,
- "cn": "读取统计量参数文件失败警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_039": {
- "name": null,
- "cn": "读取个性化参数文件失败警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_040": {
- "name": null,
- "cn": "读取通用性参数文件失败警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_041": {
- "name": null,
- "cn": "读取掉电保存变量文件失败警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_042": {
- "name": null,
- "cn": "存储统计量参数文件失败警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_043": {
- "name": null,
- "cn": "存储个性化参数文件失败警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_044": {
- "name": null,
- "cn": "存储通用性参数文件失败警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_045": {
- "name": null,
- "cn": "存储掉电保存变量文件失败警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_046": {
- "name": null,
- "cn": "存储掉电保存变量文件失败故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_047": {
- "name": null,
- "cn": "存储统计量参数文件失败故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_048": {
- "name": null,
- "cn": "存储个性化参数文件失败故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_049": {
- "name": null,
- "cn": "存储通用性参数文件失败故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_050": {
- "name": null,
- "cn": "读取掉电保存变量文件失败故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_051": {
- "name": null,
- "cn": "读取统计量参数文件失败故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_052": {
- "name": null,
- "cn": "读取个性化参数文件失败故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_053": {
- "name": null,
- "cn": "读取存储通用性参数文件失败故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_054": {
- "name": null,
- "cn": "Ethercat通讯故障自恢复",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "230",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_055": {
- "name": null,
- "cn": "Ethercat故障自恢复失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "175",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_056": {
- "name": null,
- "cn": "Ethercat故障重复出现",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "175",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_057": {
- "name": null,
- "cn": "EtherCAT冗余网线连接故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_058": {
- "name": null,
- "cn": "EtherCat模块通讯断开",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "175",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_059": {
- "name": null,
- "cn": "EtherCAT通讯建立失败",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "175",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_060": {
- "name": null,
- "cn": "EtherCAT通讯环网重组",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "10",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_21_061": {
- "name": null,
- "cn": "EtherCAT通讯环网重组警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "165",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_29_001": {
- "name": null,
- "cn": "齿轮箱颗粒检测装置异常",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_29_002": {
- "name": null,
- "cn": "齿轮箱颗粒检测数量异常警告",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "40",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_29_003": {
- "name": null,
- "cn": "齿轮箱颗粒检测数量异常故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "170",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_29_004": {
- "name": null,
- "cn": "Acoem CMS通讯故障",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_29_005": {
- "name": null,
- "cn": "Acoem CMS多次触发危险值",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_29_006": {
- "name": null,
- "cn": "前主轴承报警值超限",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_29_007": {
- "name": null,
- "cn": "后主轴承报警值超限",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_29_008": {
- "name": null,
- "cn": "齿轮箱报警值超限",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_29_009": {
- "name": null,
- "cn": "发电机驱动端报警值超限",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "04_29_010": {
- "name": null,
- "cn": "发电机非驱动端报警值超限",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- },
- "sc04_04_044": {
- "name": null,
- "cn": "主轴承润滑系统加热器未运行一周",
- "subsystem": null,
- "level": null,
- "reset_mode": null,
- "type": null,
- "alarm": null,
- "set_delay": null,
- "powerup_delay": null,
- "repeat_n": null,
- "repeat_period": null,
- "brake_state_design": "",
- "bp_runtime_2015": null,
- "src": "scada_lang_2015",
- "trigger_granularity": null,
- "detectable_in_10min": null
- }
- },
- "params_never_referenced_by_any_code": [
- "PAR_CVT_CANOpen_AmsNetId",
- "PAR_CVT_CANOpen_PortNr",
- "PAR_Gen_CoilTempHigh",
- "PAR_Gen_CoilTempLow",
- "PAR_Gen_RatedPower",
- "PAR_Gen_ReducedPower",
- "PAR_PowerLimitFromSCADA",
- "PAR_TempForTurbineColdStart",
- "PAR_TempForTurbineNormalStart",
- "PAR_VoltageRatioForUMG103",
- "PAR_YBox_CANOpen_AmsNetId",
- "PAR_YBox_CANOpen_PortNr",
- "PAR_bAVRConverterOn",
- "PAR_bAVRPowerPriority",
- "PAR_bAutoRestartFromGridFailure",
- "PAR_bBatteryVoltSendProtocol",
- "PAR_bCCTempReduEnabled",
- "PAR_bCS_EnableWaterLeakMonitor",
- "PAR_bCableWithTempSensor",
- "PAR_bConPowerReduEnabled",
- "PAR_bCutInShopFloorTest",
- "PAR_bDefectFreeCabinet",
- "PAR_bDisableOverPower",
- "PAR_bEnable24ReduMonitor",
- "PAR_bEnableAutoRebootPLC",
- "PAR_bEnableBladeZeroPositionFunction",
- "PAR_bEnableCheckOfRemoteReset",
- "PAR_bEnableGearboxPowerReduction",
- "PAR_bEnableMetalScanSensor",
- "PAR_bEnableMianShaftCrackDetect",
- "PAR_bEnablePLCWatchdog",
- "PAR_bEnablePowerReduByGenerator",
- "PAR_bEnablePowerValueLimit",
- "PAR_bEnableSPDMonitor",
- "PAR_bEnableSelfTest",
- "PAR_bEnableSelftest1",
- "PAR_bEnableSelftest2",
- "PAR_bEnableSelftest3",
- "PAR_bEnableSelftest4",
- "PAR_bEnableSelftest5",
- "PAR_bEnableSpeedSpikeFilter",
- "PAR_bEnableWindCalibration",
- "PAR_bEnableWindIrisAutoControlMode",
- "PAR_bEnableWindIrisManualControlMode",
- "PAR_bEncoderGenSpeedFromFreq",
- "PAR_bEncoderRotorSpeedFromFreq",
- "PAR_bFFTStopPowerReductionEnable",
- "PAR_bFFTWarningPowerReductionEnable",
- "PAR_bFFTWarningSpeedReductionEnable",
- "PAR_bGBX_EnableFuseHeater_GearOilPipe",
- "PAR_bGBX_OilFilter_Enable",
- "PAR_bGJ_EnableBadDataDetect",
- "PAR_bGenSpeedFromConverter",
- "PAR_bGenWithTempInOutlet",
- "PAR_bHeaterControlByEnvision_WCS",
- "PAR_bHydrPumpControlledBySwitch",
- "PAR_bIGBTTempReduEnabled",
- "PAR_bNAC_EnableHeaterFunction",
- "PAR_bPCH_EnableBadDataDetect",
- "PAR_bPCH_HubEnableBadDataDetect",
- "PAR_bPowerProcessFromConverter",
- "PAR_bReleaseFunction_PitchMotorStop",
- "PAR_bSectorReduEnabled",
- "PAR_bSelectDiffYawStrategy",
- "PAR_bSelectGenSpeedFromEncoder",
- "PAR_bSelectReactivePowerSetPointFromWindFarm",
- "PAR_bSpecialUPSForCT",
- "PAR_bStartWindIris",
- "PAR_bSwitchPhiOrReactivePowerCmd",
- "PAR_bTCSFeedforwardControlON",
- "PAR_bTCS_EnableWaterLeakMonitor",
- "PAR_bUseWindIris",
- "PAR_bWindfarmControlEnable",
- "PAR_bWinergyGearboxOilInletNoPT100",
- "PAR_bYawEncoderByCANOpen",
- "PAR_bYawPositionReversed",
- "PAR_gbyCountryCode",
- "PAR_gbyTurbineNumber",
- "PAR_gsCompanyCode",
- "PAR_gsTurbineType",
- "PAR_gsWindPark",
- "PAR_i5DaysElapsed",
- "PAR_iAddEtherCAT_GCC_BK1250",
- "PAR_iAddEtherCAT_Nacelle_BK1120_1",
- "PAR_iAddEtherCAT_Nacelle_BK1120_2",
- "PAR_iAddEtherCAT_Nacelle_BK1250",
- "PAR_iAddEtherCAT_Tower_BK1250",
- "PAR_iCANConverterTimeoutLevel1FaultCount",
- "PAR_iCANConverterTimeoutLevel2FaultCount",
- "PAR_iCVT1CANAddress",
- "PAR_iCVT2CANAddress",
- "PAR_iCabinetVersion",
- "PAR_iConverterType",
- "PAR_iConverter_DCLinkChargeTimeOutFaultCount",
- "PAR_iCoolingSystemType",
- "PAR_iDriveTrainType",
- "PAR_iDrivetrainFaultRepeatRate",
- "PAR_iEthercatDevicesNumber",
- "PAR_iEthercatRepeatRate",
- "PAR_iFireAlarmType",
- "PAR_iGCCType",
- "PAR_iGearBoxType",
- "PAR_iGearOilFilterOffLineControlStrategy",
- "PAR_iGearOilFilterOffLine_CheckCycle",
- "PAR_iGearOilFilterOffLine_CheckDate",
- "PAR_iGearOilFilterPresureCheckDelayTime",
- "PAR_iGenType",
- "PAR_iGridMeasureType",
- "PAR_iHydraulicType",
- "PAR_iLIDARSensorType",
- "PAR_iMainBearingLubType",
- "PAR_iMeteoWindSensorCtrlMode",
- "PAR_iNacelleType",
- "PAR_iNacelleVibrationSensorType",
- "PAR_iPCH_HubType",
- "PAR_iPercentOfYawMinimumTime_HighWindSpeed",
- "PAR_iPercentOfYawMinimumTime_LowWindSpeed",
- "PAR_iPitchCANAddress",
- "PAR_iPitchFaultRepeatRateLevel1",
- "PAR_iPitchFaultRepeatRateLevel2",
- "PAR_iPitchSystemType",
- "PAR_iRebootPLCMaxNum",
- "PAR_iResetCheck_Limit",
- "PAR_iResetCheck_Period",
- "PAR_iRotorBrakeType",
- "PAR_iRotorLockType",
- "PAR_iSafetySystemType",
- "PAR_iTowerCoolingSystemType",
- "PAR_iTraceLogType",
- "PAR_iTurbineType",
- "PAR_iUPSTime_Min",
- "PAR_iWindSingalType",
- "PAR_iYawGreaseType",
- "PAR_iYawNewStrategy",
- "PAR_iYawSystemType",
- "PAR_rAccelLimit2OmniDirection",
- "PAR_rAccumulatorPressureLowerLimit",
- "PAR_rAccumulatorPressureUpperLimit",
- "PAR_rAirPressureSignalMax",
- "PAR_rAirPressureSignalMin",
- "PAR_rAnglePitchNotFollow",
- "PAR_rAsynPitchAngle_Level1",
- "PAR_rAsynPitchAngle_Level2",
- "PAR_rBandFilterNacelleForaftVibrationAlarm",
- "PAR_rBandFilterNacelleForaftVibrationFault",
- "PAR_rBandFilterNacelleForaftVibrationNormal",
- "PAR_rBandFilterNacelleSideSideVibrationAlarm",
- "PAR_rBandFilterNacelleSideSideVibrationFault",
- "PAR_rBandFilterNacelleSideSideVibrationNormal",
- "PAR_rBladeEncoderDefect",
- "PAR_rBladeZeroPositionInsideOffsetWarning",
- "PAR_rBladeZeroPositionOutsideOffsetWarning",
- "PAR_rBrakePressureHighUnderProduction",
- "PAR_rCCC_LowerTempHyst",
- "PAR_rCCC_TempHigh",
- "PAR_rCCC_TempLow",
- "PAR_rCCC_TempMAX",
- "PAR_rCCC_TempMIN",
- "PAR_rCCC_TempStartCooling",
- "PAR_rCCC_TempStartHeating",
- "PAR_rCCC_TempStopCooling",
- "PAR_rCCC_TempStopHeating",
- "PAR_rCCC_UpperTempHyst",
- "PAR_rCC_TempHigh_Derate_Start",
- "PAR_rCC_TempHigh_Derate_Stop",
- "PAR_rCC_TempHigh_ReducedPower",
- "PAR_rCC_Temp_High",
- "PAR_rCC_Temp_Low",
- "PAR_rCC_Temp_Low_Restart",
- "PAR_rCC_Temp_VeryHigh",
- "PAR_rCS_MAXPreDescendRate",
- "PAR_rCS_PumpInletPressureSignalMax",
- "PAR_rCS_PumpInletPressureSignalMin",
- "PAR_rCS_PumpMINPressureErr",
- "PAR_rCS_PumpOutletPressureSignalMax",
- "PAR_rCS_PumpOutletPressureSignalMin",
- "PAR_rCS_TempCoefficient",
- "PAR_rCVTPositionFollow_DeadBand",
- "PAR_rCVTSpeedMode_MaxAcceleration",
- "PAR_rCVTSpeedMode_MaxSpeedSetValue",
- "PAR_rCVTSpeedMode_MaxWindSpeed",
- "PAR_rCVTSpeedMode_MinSpeedSetValue",
- "PAR_rCVTWaterCoolInOutPressureDiffHigh",
- "PAR_rCVTWaterCoolInOutPressureDiffLow",
- "PAR_rCVT_IGBT_TempHigh_Derate_Start",
- "PAR_rCVT_IGBT_TempHigh_Derate_Stop",
- "PAR_rCVT_IGBT_TempHigh_ReducedPower",
- "PAR_rCVT_LowerTempHyst",
- "PAR_rCVT_UpperTempHyst",
- "PAR_rCabinet_LowerTempHyst",
- "PAR_rCabinet_UpperTempHyst",
- "PAR_rCoreControllerMaxPitchAngle",
- "PAR_rCosPhiSetPointValue",
- "PAR_rCouplingSlipDetect",
- "PAR_rDecreaseTempDisableGBXOilSumpHeater",
- "PAR_rDecreaseTempEnableGBXOilSumpHeater",
- "PAR_rDiffNacelleDisableNacelleHeating",
- "PAR_rDiffNacelleEnableNacelleHeating",
- "PAR_rDiffOverspeedRelayDetectFail",
- "PAR_rDiffYawTrackingFastReaction",
- "PAR_rDiffYawTrackingSlowReaction",
- "PAR_rFFTPowerReductionFactor",
- "PAR_rFFTPowerReductionLowerLimit",
- "PAR_rFFTSpeedlimitation",
- "PAR_rFFTSpeedlimitationFactor",
- "PAR_rFFTStopPowerReductionLevel",
- "PAR_rGBXBearingPowerLimitPowerHigh",
- "PAR_rGBXBearingPowerLimitPowerLow",
- "PAR_rGBXOilPowerLimitPowerHigh",
- "PAR_rGBXOilPowerLimitPowerLow",
- "PAR_rGBXOilPumpMotorPreheaterDisableTemp",
- "PAR_rGBXOilPumpMotorPreheaterEnableTemp",
- "PAR_rGBXTempHysteresisLowerTemp",
- "PAR_rGBXTempHysteresisUpperTemp",
- "PAR_rGBXTorqueArmPositionAlarm",
- "PAR_rGBXTorqueArmPositionMax",
- "PAR_rGBXTorqueArmPositionMin",
- "PAR_rGBXTorqueArmPositionNormal",
- "PAR_rGBXTorqueArmPositionWarming",
- "PAR_rGBX_OilFilter_EndTemp",
- "PAR_rGBX_OilFilter_StartTemp",
- "PAR_rGBX_OilFilter_StopTemp",
- "PAR_rGBX_OilFilter_TempHysteresis",
- "PAR_rGCC_Temp_High",
- "PAR_rGCC_Temp_Low",
- "PAR_rGCC_Temp_Low_Restart",
- "PAR_rGCC_Temp_VeryHigh",
- "PAR_rGENCoilTempDiffMAX",
- "PAR_rGEN_NacelleTempToStartFan",
- "PAR_rGEN_StatorTempDiffMAX",
- "PAR_rGEN_StatorTempToStartFan",
- "PAR_rGLGenWaterCool_InletPressureSignalMax",
- "PAR_rGLGenWaterCool_InletPressureSignalMin",
- "PAR_rGLGenWaterCool_OutletPressureSignalMax",
- "PAR_rGLGenWaterCool_OutletPressureSignalMin",
- "PAR_rGearOilDiffPressureInlineFilterMax",
- "PAR_rGearOilDiffPressureInlineFilterMin",
- "PAR_rGearOilFilterInletPressSignalMax",
- "PAR_rGearOilFilterInletPressSignalMin",
- "PAR_rGearOilGBXInletPressSignalMax",
- "PAR_rGearOilGBXInletPressSignalMin",
- "PAR_rGearOilPressure_MIN",
- "PAR_rGearOilPressure_MIN_PumpHS",
- "PAR_rGearOilPressure_MIN_PumpLS",
- "PAR_rGenRPMSwitchPumpMode_LS",
- "PAR_rGenSpeedBandStartMode",
- "PAR_rGenSpeedBelowMainBrakeON",
- "PAR_rGenSpeedForConverterRdy_Run",
- "PAR_rGenSpeedForGBXOilPump",
- "PAR_rGenSpeedForWindValidation",
- "PAR_rGenSpeedOfHSBrakeFinish",
- "PAR_rGenSpeedSetValueBrakeMode50",
- "PAR_rGenSpeedStartMode",
- "PAR_rGenSpeedToCheckConverterSpeedOK",
- "PAR_rGenSpeed_GearboxHeaterOFF",
- "PAR_rGenSpeed_GearboxHeaterON",
- "PAR_rGenWaterCoolInOutPressureDiffHigh",
- "PAR_rGenWaterCoolInOutPressureDiffLow",
- "PAR_rGeneratorNominalTorque",
- "PAR_rGridFrequencyHigh_Hz",
- "PAR_rGridFrequencyLow_Hz",
- "PAR_rHVRTVolLevel1Multiplier",
- "PAR_rHVRTVolLevel2Multiplier",
- "PAR_rHighYawDegree_Sector1",
- "PAR_rHighYawDegree_Sector2",
- "PAR_rHighYawDegree_Sector3",
- "PAR_rHighYawDegree_Sector4",
- "PAR_rHydSystemPressMIN_Stop",
- "PAR_rHydSystemPressMainCircuitMIN_Stop",
- "PAR_rHydrAccuBrakePressSignalMax",
- "PAR_rHydrAccuBrakePressSignalMin",
- "PAR_rHydrAccuPreChargePressSignalMax",
- "PAR_rHydrAccuPreChargePressSignalMin",
- "PAR_rHydrAccuSumpPressSignalMax",
- "PAR_rHydrAccuSumpPressSignalMin",
- "PAR_rHystYawDegree_Sector",
- "PAR_rIncreaseTempDisableGBXOilSumpHeater",
- "PAR_rIncreaseTempEnableGBXOilSumpHeater",
- "PAR_rKpGenSpeedPT2Filter",
- "PAR_rLifeSignFrequencyWindfarmCom",
- "PAR_rLowYawDegree_Sector1",
- "PAR_rLowYawDegree_Sector2",
- "PAR_rLowYawDegree_Sector3",
- "PAR_rLowYawDegree_Sector4",
- "PAR_rMainShaftCrackAlarmRPMDiff",
- "PAR_rMarginForGenPDMTimeoutDetect",
- "PAR_rMarginForRotorPDMTimeoutDetect",
- "PAR_rMarginSensorOutOfRange",
- "PAR_rMaxDiffSetAndSensorsBladeAngle_PitchLimit3",
- "PAR_rMaxDiffSetAndSensorsBladeAngle_PitchLimit4",
- "PAR_rMaxDiffZeroPos",
- "PAR_rMaxGenSpeedAtBrakeTest",
- "PAR_rMaxGeneratorTorque",
- "PAR_rMaxNacelleHumidity",
- "PAR_rMaxPitchAccelleration",
- "PAR_rMaxPitchAngleForLimit91",
- "PAR_rMaxPitchAngleForLimit95",
- "PAR_rMaxPitchSpeed",
- "PAR_rMaxPower100ms",
- "PAR_rMaxWindSpeedByPitchAngle_30sec",
- "PAR_rMinGeneratorTorque",
- "PAR_rMinPitchAngleForLimit91",
- "PAR_rMinPitchAngleForLimit95",
- "PAR_rMinPitchAngleSector1",
- "PAR_rMinPitchAngleSector2",
- "PAR_rMinPitchAngleSector3",
- "PAR_rMinPitchAngleSector4",
- "PAR_rMinPitchSpeed",
- "PAR_rMinSpeedToCalcSpeedByPDM",
- "PAR_rNacelleTempEnableNacelleHeating",
- "PAR_rNacelleTempHysteresisLowerTemp",
- "PAR_rNacelleTempHysteresisUpperTemp",
- "PAR_rOffsetActiveEnergyConsum",
- "PAR_rOffsetActiveEnergyOverall",
- "PAR_rOffsetOfOverSpeedForLVRT",
- "PAR_rOffsetOfVibrationForLVRT",
- "PAR_rOffsetPitchAngle1Blade1",
- "PAR_rOffsetPitchAngle1Blade2",
- "PAR_rOffsetPitchAngle1Blade3",
- "PAR_rOffsetPitchAngle2Blade1",
- "PAR_rOffsetPitchAngle2Blade2",
- "PAR_rOffsetPitchAngle2Blade3",
- "PAR_rOffsetReactiveEnergyConsum",
- "PAR_rOffsetReactiveEnergyOverall",
- "PAR_rOffsetVane1",
- "PAR_rOffsetVane2",
- "PAR_rOffset_Azimuth_Position_Rotor",
- "PAR_rOutsideTempDisableNacelleHeating",
- "PAR_rOutsideTempEnableNacelleHeating",
- "PAR_rOverspeedRelayDetectFailSignalMax",
- "PAR_rOverspeedRelayDetectFailSignalMin",
- "PAR_rPCH_HubFFTAlarmResetValue",
- "PAR_rPCH_HubFFTAlertValue",
- "PAR_rPCH_HubFFTDangerValue",
- "PAR_rPCH_HubPPAlarmResetValue",
- "PAR_rPCH_HubPPAlertValue",
- "PAR_rPCH_HubPPDangerValue",
- "PAR_rPCH_HubPeakAlarmResetValue",
- "PAR_rPCH_HubPeakAlertValue",
- "PAR_rPCH_HubPeakDangerValue",
- "PAR_rPitchAngleSelftest1",
- "PAR_rPitchAngleSelftest2",
- "PAR_rPitchAngleSetValueBrakeMode50",
- "PAR_rPitchAxisBoxMaxTemp",
- "PAR_rPitchAxisBoxMinTemp",
- "PAR_rPitchBackupMaxTemp",
- "PAR_rPitchBackupMaxVolt",
- "PAR_rPitchBackupMinTemp",
- "PAR_rPitchBackupMinVolt",
- "PAR_rPitchDeadZoneForSelftest2",
- "PAR_rPitchHVRT_Level1",
- "PAR_rPitchHVRT_Level2",
- "PAR_rPitchHubMaxTemp",
- "PAR_rPitchHubMinTemp",
- "PAR_rPitchLBAMaxTemp",
- "PAR_rPitchLBAMinTemp",
- "PAR_rPitchMotorMaxTemp",
- "PAR_rPitchMotorMinTemp",
- "PAR_rPowerLimitDownRateSector",
- "PAR_rPowerLimitSector1",
- "PAR_rPowerLimitSector2",
- "PAR_rPowerLimitSector3",
- "PAR_rPowerLimitSector4",
- "PAR_rPowerLimitUpRateSector",
- "PAR_rPowerLimitationMargin",
- "PAR_rPowerLimitationMarginOffset",
- "PAR_rPreMAX_WCSOfCon",
- "PAR_rPreMAX_WCSOfGen",
- "PAR_rPreMIN_WCSOfCon",
- "PAR_rPreMIN_WCSOfGen",
- "PAR_rPulsesPerGeneratorRotation",
- "PAR_rPulsesPerRotorRotation",
- "PAR_rRMSHighSpeedAlarm",
- "PAR_rRMSHighSpeedNormal",
- "PAR_rRMSHighSpeedWarning",
- "PAR_rRMSLowSpeedAlarm",
- "PAR_rRMSLowSpeedNormal",
- "PAR_rRMSLowSpeedWarning",
- "PAR_rRPMLimitDownRateSector",
- "PAR_rRPMLimitSector1",
- "PAR_rRPMLimitSector2",
- "PAR_rRPMLimitSector3",
- "PAR_rRPMLimitSector4",
- "PAR_rRPMLimitUpRateSector",
- "PAR_rReactivePowerSetPointValue",
- "PAR_rRotorLockPushOutPressureHyst",
- "PAR_rRotorLock_PushOutPressureSignalMax",
- "PAR_rRotorLock_PushOutPressureSignalMin",
- "PAR_rRotorPosOffset",
- "PAR_rRotorSpeed_N_Check",
- "PAR_rRotorSpeed_N_Hyst",
- "PAR_rRuntimeSelftest1",
- "PAR_rSTD_GenSpeed_Normal",
- "PAR_rSTD_GenSpeed_VeryHigh",
- "PAR_rSTD_RotorSpeed_Normal",
- "PAR_rSTD_RotorSpeed_VeryHigh",
- "PAR_rScalingFactorEncPos",
- "PAR_rScalingFactorGenActivePower",
- "PAR_rScalingFactorGenPosition",
- "PAR_rScalingFactorGenSpeed",
- "PAR_rScalingFactorGenTorque",
- "PAR_rScalingFactorPhi",
- "PAR_rScalingFactorReactivePower",
- "PAR_rSelftestMaxWindspeed",
- "PAR_rSetValueRPMatNominalPower",
- "PAR_rShutDownFastForLowPower",
- "PAR_rSimLVRTTorque",
- "PAR_rSlipCriticallyDegree",
- "PAR_rSpeedDiffForSlipBegin",
- "PAR_rSpeedDiffForSlipEnd",
- "PAR_rSpeedOKForCVTDetection",
- "PAR_rStartCabinetHeater",
- "PAR_rSumPitchStartToCAGEMode",
- "PAR_rSumPitchStartToDFIGMode",
- "PAR_rSwitchPumpHours",
- "PAR_rSystemPressureMainCircuitSTART_HydrPump",
- "PAR_rSystemPressureMainCircuitSTOP_HydrPump",
- "PAR_rSystemPressureStart_HydrPump",
- "PAR_rSystemPressureStop_HydrPump",
- "PAR_rTCS_ECF_AirTemp_Level1_Disable",
- "PAR_rTCS_ECF_AirTemp_Level1_Enable",
- "PAR_rTCS_ECF_AirTemp_Level2_Disable",
- "PAR_rTCS_ECF_AirTemp_Level2_Enable",
- "PAR_rTCS_ECF_AirTemp_Level3_Disable",
- "PAR_rTCS_ECF_AirTemp_Level3_Enable",
- "PAR_rTCS_ECF_AirTemp_Level4_Disable",
- "PAR_rTCS_ECF_AirTemp_Level4_Enable",
- "PAR_rTCS_ECF_Disabled_Time_Min",
- "PAR_rTCS_ECF_Enabled_Time_Min",
- "PAR_rTCS_ECF_WaterTemp_Level1_Disable",
- "PAR_rTCS_ECF_WaterTemp_Level1_Enable",
- "PAR_rTCS_ECF_WaterTemp_Level2_Disable",
- "PAR_rTCS_ECF_WaterTemp_Level2_Enable",
- "PAR_rTCS_ECF_WaterTemp_Level3_Disable",
- "PAR_rTCS_ECF_WaterTemp_Level3_Enable",
- "PAR_rTCS_ECF_WaterTemp_Level4_Disable",
- "PAR_rTCS_ECF_WaterTemp_Level4_Enable",
- "PAR_rTCS_ICF_AirTemp_Disable",
- "PAR_rTCS_ICF_AirTemp_Enable",
- "PAR_rTCS_MAXPreDescendRate",
- "PAR_rTCS_MaxTowerAirTemp",
- "PAR_rTCS_MixingValveMaxDiff",
- "PAR_rTCS_MixingValveMoveMINDiff",
- "PAR_rTCS_MixingValveMoveSpeed",
- "PAR_rTCS_OffsetTempInsideCooler",
- "PAR_rTCS_PID_AcceptErr",
- "PAR_rTCS_PID_CtrlCycleTime",
- "PAR_rTCS_PID_CutInErr",
- "PAR_rTCS_PID_DeadZoneCutOut",
- "PAR_rTCS_PID_Para_D_1",
- "PAR_rTCS_PID_Para_D_2",
- "PAR_rTCS_PID_Para_D_3",
- "PAR_rTCS_PID_Para_D_Damp",
- "PAR_rTCS_PID_Para_I_1",
- "PAR_rTCS_PID_Para_I_2",
- "PAR_rTCS_PID_Para_I_3",
- "PAR_rTCS_PID_Para_P_1",
- "PAR_rTCS_PID_Para_P_2",
- "PAR_rTCS_PID_Para_P_3",
- "PAR_rTCS_PumpInletPressureSignalMax",
- "PAR_rTCS_PumpInletPressureSignalMin",
- "PAR_rTCS_PumpInletPressureTooLow",
- "PAR_rTCS_PumpMINPressureErr",
- "PAR_rTCS_PumpOutletPreHigh",
- "PAR_rTCS_PumpOutletPressureSignalMax",
- "PAR_rTCS_PumpOutletPressureSignalMin",
- "PAR_rTCS_TempCoefficient",
- "PAR_rTCS_TowerTempHigh",
- "PAR_rTCS_TowerTempTooHigh",
- "PAR_rTCS_WaterInletTempLowWarning",
- "PAR_rTempDIFFHeaterCabinetsON",
- "PAR_rTempDiffFrontAndRearBearing",
- "PAR_rTempDisableGBXOilPumpHS",
- "PAR_rTempDisableGBXOilPumpLS",
- "PAR_rTempDriveTrainHysteresis",
- "PAR_rTempEnableGBXOilPumpHS",
- "PAR_rTempEnableGBXOilPumpLS",
- "PAR_rTempGBXBearingHSSHigh",
- "PAR_rTempGBXBearingHSSMax",
- "PAR_rTempGBXBearingIMSHigh",
- "PAR_rTempGBXBearingIMSMax",
- "PAR_rTempGearOilFilterMonitor",
- "PAR_rTempGearOilLevelMoniter",
- "PAR_rTempGearOilPump_HS_ON",
- "PAR_rTempGearOilPump_LS_ON",
- "PAR_rTempGearboxHeatingMode",
- "PAR_rTempGearbox_BearingNDE_FanHS_OFF",
- "PAR_rTempGearbox_BearingNDE_FanHS_ON",
- "PAR_rTempGearbox_BearingNDE_FanLS_OFF",
- "PAR_rTempGearbox_BearingNDE_FanLS_ON",
- "PAR_rTempGearbox_HeaterON",
- "PAR_rTempGearbox_OilSink_FanHS_OFF",
- "PAR_rTempGearbox_OilSink_FanHS_ON",
- "PAR_rTempGearbox_OilSink_FanLS_OFF",
- "PAR_rTempGearbox_OilSink_FanLS_ON",
- "PAR_rTempGenHysteresis",
- "PAR_rTempGenStatorHeaterMIN",
- "PAR_rTempHigh_GearBearingInterDE",
- "PAR_rTempHigh_GearBearingInterNDE",
- "PAR_rTempHysteresisGenStatorHeaterHigh",
- "PAR_rTempHysteresisGenStatorHeaterLow",
- "PAR_rTempHysteresisNacelleTemp",
- "PAR_rTempHysteresisToDisableOverPower",
- "PAR_rTempLow_CabinetNacelle",
- "PAR_rTempLow_RotorBearingA",
- "PAR_rTempMAX_GearBearingInterDE",
- "PAR_rTempMAX_GearBearingInterNDE",
- "PAR_rTempMAX_WCSOfCon",
- "PAR_rTempMAX_WCSOfGen",
- "PAR_rTempMIN_RotorBearingA",
- "PAR_rTempMIN_WCSOfCon",
- "PAR_rTempMIN_WCSOfGen",
- "PAR_rTempNacelle_NacelleInletDamperDisable",
- "PAR_rTempNacelle_NacelleInletDamperEnable",
- "PAR_rTempNacelle_NacelleOutletDamperDisable",
- "PAR_rTempNacelle_NacelleOutletDamperEnable",
- "PAR_rTempNacelle_NacelleOutletFanDisable",
- "PAR_rTempNacelle_NacelleOutletFanEnable",
- "PAR_rTempOutdoorOutOfSpecMAX",
- "PAR_rTempOutdoorOutOfSpecMIN",
- "PAR_rTempWCSOfCon_HeaterOFF",
- "PAR_rTempWCSOfCon_HeaterON",
- "PAR_rTempWCSOfGen_HeaterOFF",
- "PAR_rTempWCSOfGen_HeaterON",
- "PAR_rTempWindsensors_HeaterON",
- "PAR_rTemp_CS_GBXLevel1OFF",
- "PAR_rTemp_CS_GBXLevel1ON",
- "PAR_rTemp_CS_GBXLevel2OFF",
- "PAR_rTemp_CS_GBXLevel2ON",
- "PAR_rTemp_CS_GBXLevel3OFF",
- "PAR_rTemp_CS_GBXLevel3ON",
- "PAR_rTemp_CS_GBXLevel4OFF",
- "PAR_rTemp_CS_GBXLevel4ON",
- "PAR_rTemp_CS_GBXOutletHigh",
- "PAR_rTemp_CS_GBXOutletHigh_Hysteresis",
- "PAR_rTemp_CS_GENLevel2OFF",
- "PAR_rTemp_CS_GENLevel2ON",
- "PAR_rTemp_CS_GENLevel3OFF",
- "PAR_rTemp_CS_GENLevel3ON",
- "PAR_rTemp_CS_GENLevel4OFF",
- "PAR_rTemp_CS_GENLevel4ON",
- "PAR_rTemp_CS_GENOutletHigh_Hysteresis",
- "PAR_rTimeForForceSelfTest",
- "PAR_rTimeForGBXPumpLSOFFInterval",
- "PAR_rTimeForGBXPumpLSONInterval",
- "PAR_rToleranceAngleForMotorStop",
- "PAR_rToleranceYawEncoderFault",
- "PAR_rTransformerPhaseTempDifferent",
- "PAR_rTransformerTempHigh",
- "PAR_rTransformerTempVeryHigh",
- "PAR_rValueBlockYawForVibration",
- "PAR_rWCSCVTFanOn",
- "PAR_rWCSCVTHeaterOn",
- "PAR_rWCSCVTHysteresis",
- "PAR_rWCSCVTInletPreHigh1",
- "PAR_rWCSCVTInletPreHigh2",
- "PAR_rWCSCVTInletPreLow1",
- "PAR_rWCSCVTInletPreLow2",
- "PAR_rWCSCVTInletTempHigh1",
- "PAR_rWCSCVTInletTempHigh2",
- "PAR_rWCSCVTInletTempLow",
- "PAR_rWCSCVTOutletPreLow1",
- "PAR_rWCSCVTOutletPreLow2",
- "PAR_rWCSCVTTripleValve",
- "PAR_rWCSGENFan1On",
- "PAR_rWCSGENFan2On",
- "PAR_rWCSGENFan3On",
- "PAR_rWCSGENHeaterOn",
- "PAR_rWCSGENHysteresisTripleValve",
- "PAR_rWCSGENInletPreHigh1",
- "PAR_rWCSGENInletPreHigh2",
- "PAR_rWCSGENInletPreLow1",
- "PAR_rWCSGENInletPreLow2",
- "PAR_rWCSGENInletTempHigh1",
- "PAR_rWCSGENInletTempLow",
- "PAR_rWCSGENOutletPreLow1",
- "PAR_rWCSGENOutletPreLow2",
- "PAR_rWCSGENOutletTempHigh",
- "PAR_rWCSGENTripleValve",
- "PAR_rWFMSActivePowerSetValueMIN",
- "PAR_rWFMSReactivePowerSetValueMAX",
- "PAR_rWFMSReactivePowerSetValueMIN",
- "PAR_rWeight_CS_PumpHigh",
- "PAR_rWeight_CS_PumpLow",
- "PAR_rWindDirectionMaxDiffValue",
- "PAR_rWindDirectionMaxDiffValue_WindIris",
- "PAR_rWindSpeed2CalibrationCoefficientA",
- "PAR_rWindSpeed2CalibrationCoefficientB",
- "PAR_rWindSpeed2CalibrationCoefficientC",
- "PAR_rWindSpeedAbovePitchMove",
- "PAR_rWindSpeedCalibrationCoefficientA",
- "PAR_rWindSpeedCalibrationCoefficientB",
- "PAR_rWindSpeedCalibrationCoefficientC",
- "PAR_rWindSpeedEnableMaxYawUntwist",
- "PAR_rWindSpeedMaxDiffValue",
- "PAR_rWindSpeedSelectDiffYawStrategy",
- "PAR_rWindSpeedSignalMax",
- "PAR_rWindSpeedSignalMin",
- "PAR_rWindYawTreckingFastReaction",
- "PAR_rYawEncoderBacklash",
- "PAR_rYawMaxDeviationAtAllWindspeeds",
- "PAR_rYawMotorHeatersDisabled",
- "PAR_rYawMotorHeatersEnabled",
- "PAR_rYawPositionSignalMax",
- "PAR_rYawPositionSignalMin",
- "PAR_rYawSensorOffsetAtCableTwistZero",
- "PAR_rYawSpeed_grdpermin",
- "PAR_rYawTurnsAtLimitSwitchLevel2",
- "PAR_tBasicDelayForRestart",
- "PAR_tBlockYawForVibration_ResetDelay",
- "PAR_tCANConverterAutoResetDelayTime",
- "PAR_tCANConverterTimeout",
- "PAR_tCANConverterTimeoutLevel1",
- "PAR_tCANConverterTimeoutLevel1Period",
- "PAR_tCANConverterTimeoutLevel2",
- "PAR_tCANConverterTimeoutLevel2Period",
- "PAR_tCS_JudgeInterval",
- "PAR_tCS_SampleInterval",
- "PAR_tCVT_MinInterval_TwiceCharge",
- "PAR_tConverter_DCLinkChargeAutoResetDelayTime",
- "PAR_tConverter_DCLinkChargeTimeOutPeriod",
- "PAR_tConverter_MasterSlaveConfigurationPeriod",
- "PAR_tCoreControllerComTimeout",
- "PAR_tCrossReferenceCheck_WindIris",
- "PAR_tCutOffDelayConverter",
- "PAR_tDelayCloseYawMotorBrake",
- "PAR_tDelayDrivetrainRecoveryTime",
- "PAR_tDelayEl6751ResetOpInPoweringUp",
- "PAR_tDelayForCheckValvePosition",
- "PAR_tDelayForPowerUpReboot",
- "PAR_tDelayOpenYawMotorBrakes",
- "PAR_tDelayPitchRecoveryTimeLevel1",
- "PAR_tDelayPitchRecoveryTimeLevel2",
- "PAR_tDelayToStartHydrBrake",
- "PAR_tDelayToStopHydrBrake",
- "PAR_tDetecTowerVibrationDelay",
- "PAR_tDrivetrainFaultRepeatPeriod",
- "PAR_tDurationCheckYawSpeed",
- "PAR_tDurationOfVibrationOffsetForLVRT",
- "PAR_tEthercatRepeatPeriod",
- "PAR_tGJSensorComTimeout",
- "PAR_tGearOilPressureLowSetDelay",
- "PAR_tGenSpeedDelayCompareRotGen",
- "PAR_tHVRTVolLevel0SetDelay",
- "PAR_tHVRTVolLevel1SetDelay",
- "PAR_tHVRTVolLevel2SetDelay",
- "PAR_tIntervalReadBySDOAfterFault",
- "PAR_tIntervalReadTempBySDO",
- "PAR_tIntervalRebootPitchSystem",
- "PAR_tIntervalWindIrisAutoSwitch",
- "PAR_tIntervalWritePersData",
- "PAR_tLVRTSimDuration",
- "PAR_tMainBearingLubFaultDetTime",
- "PAR_tMainBearingLubOnTime",
- "PAR_tMainBearingLubPauseTime",
- "PAR_tMaxTimeAtRideThroughMode",
- "PAR_tMaxTimeReadBySDOAfterFault",
- "PAR_tPitchComTimeout",
- "PAR_tPitchFaultRepeatPeriodeLevel1",
- "PAR_tPitchFaultRepeatPeriodeLevel2",
- "PAR_tPowerupdelay",
- "PAR_tProfibusWCSCTimeout",
- "PAR_tProfibusWCSGTimeout",
- "PAR_tPulseTimeBypassFeatherLimitSwitch",
- "PAR_tSetdelayForDevicesLost",
- "PAR_tSetdelayForRecoveryEthercat",
- "PAR_tSwitchgear_Max_Time_For_Opening_Coil",
- "PAR_tSwitchgear_Time_For_Closing_Coil",
- "PAR_tT1GenSpeedPT2Filter",
- "PAR_tT1InputHighSpeedPT2Filter",
- "PAR_tT1InputLowSpeedPT2Filter",
- "PAR_tT2GenSpeedPT2Filter",
- "PAR_tT2InputHighSpeedPT2Filter",
- "PAR_tT2InputLowSpeedPT2Filter",
- "PAR_tTCS_JudgeInterval",
- "PAR_tTCS_PID_CtrlCycleTime",
- "PAR_tTCS_PID_Para_D_1",
- "PAR_tTCS_PID_Para_D_2",
- "PAR_tTCS_PID_Para_D_3",
- "PAR_tTCS_PID_Para_D_Damp",
- "PAR_tTCS_PID_Para_I_1",
- "PAR_tTCS_PID_Para_I_2",
- "PAR_tTCS_PID_Para_I_3",
- "PAR_tTCS_PumpOffSetDelay",
- "PAR_tTCS_SampleInterval",
- "PAR_tTimeOfEl6751ResetDelay",
- "PAR_tTimeOfEl6751ResetOp",
- "PAR_tTimeOutPLCWatchdog",
- "PAR_tWindfarmCOMTimeout",
- "PAR_tYawDelayRestartMotors",
- "PAR_tYawDelayStartMotors",
- "PAR_tfbPT2YawPositionT1",
- "PAR_tfbPT2YawPositionT2",
- "PAR_udGBXOilParticlePerDayAlarm",
- "PAR_udGBXOilParticlePerDayWarning",
- "PAR_udGBXOilParticleTotalAlarm",
- "PAR_udGBXOilParticleTotalWarning",
- "PAR_uiTeethOfYawBearing",
- "PAR_uiTeethOfYawEncoder",
- "PAR_uiYBox_MultiturnResolution",
- "PAR_uiYBox_SingleturnResolution"
- ]
- }
|