| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306 |
- {
- "WTG01": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "良好",
- "评估结论和维护建议": "单相绕组探头存疑,本次绕组温度取三相中位口径,不影响判定。随巡校验探头。"
- },
- "WTG02": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "已完成轴承更换,指标已恢复正常,无需处置。"
- },
- "WTG03": {
- "温升": "优秀",
- "振动": "报警",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "振动内圈特征频率处峰值为机群中位的9.2至16.1倍;温升全窗最大4.0K、近六个月中位低于机群,润滑三项正常。安排驱动端振动复测与轴承座红外测温。"
- },
- "WTG04": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "报警",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "润滑泵单次运转时长2026年1月由65秒突增至145秒,此后六个月维持115至160秒,为基线2.45倍,形态与7#同属供油阻力型。实测废油排出量与泵出口压力,排查排油回路。该台2024年11月脂样曾判超标(铜驱动),距今21个月,仅作背景,不作判定依据。"
- },
- "WTG05": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "良好",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "润滑单次运转时长历史峰值576秒已自行回落,无需处置。"
- },
- "WTG06": {
- "温升": "报警",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "前轴承温升近六个月中位高出机群11.4K、超出判定值的月份达5个月,为全场前轴承之最;后轴承仅2026年3月单月升高。测绕组绝缘与直流电阻,红外测温,调取升高月份台账。"
- },
- "WTG07": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "报警",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "润滑泵单次运转时长持续上升,指向供油管路阻力偏大。实测废油量、泵出口压力,排查排油回路。"
- },
- "WTG08": {
- "温升": "报警",
- "振动": "优秀",
- "润滑排油": "良好",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "前轴承温升近六个月中位高出机群5.7K、有3个月超出判定值,而振动六次监测频谱完全正常。红外测温与测点校验并行,先分辨真热与表偏。"
- },
- "WTG09": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "报警",
- "散热": "良好",
- "防凝露": "优秀",
- "评估结论和维护建议": "散热能力正常,同工况残差−0.46K、全场第22/38,高载工况下定子温度随环温的变化曲线与全场中位基本重合,排除慢性换热能力不足。窗内唯一一次过热为离散事件且已闭环:越过130.2℃降载线的26个时段全部集中在2025年11月10日一天,峰值152.0℃、距155℃跳闸线3.0℃,次月峰值即回落至94℃;该台其余各月定子峰值为89至114℃,均低于或接近全场同月中位。事件当日的告警链为:09时03分报出2137变频器发电机冷却器过热(早于定子温升起点17分钟),10时06分发电机温度警告,10时55分与11时41分发电机非驱动端轴承温度警告与故障,11时42分硬件要求停止;2137在本台末次发生于2025年11月13日,距数据窗末约8个月未再复发。全场越降载线的四台(9#、22#、6#、25#)均有2137告警且日期与越线日期一致,属同一机制。据此散热一项按良好管理,不作现场派工;下次登机时顺带核查冷却器换热面与风扇联锁。本台报警项为润滑排油:润滑泵连续满转在2026年5月发生4次,为2026年内全场仅有的仍在发生连续满转的机组(口径:2026年1至7月连续满转事件计数),实测泵出口压力。"
- },
- "WTG10": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "良好",
- "评估结论和维护建议": "机舱湿度全场最高档。检查除湿机与舱门密封,校验湿度探头。"
- },
- "WTG11": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "无异常。"
- },
- "WTG12": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "无异常。"
- },
- "WTG13": {
- "温升": "优秀",
- "振动": "良好",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "温升按该端判定值复核未超标;部分月份振动监测数据缺失,待数据补齐后再行判读。"
- },
- "WTG14": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "良好",
- "评估结论和维护建议": "已完成泵体更换,指标已恢复正常。加热器动作偏迟,结合湿度水平统筹处置。"
- },
- "WTG15": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "良好",
- "散热": "良好",
- "防凝露": "优秀",
- "评估结论和维护建议": "散热偏差现窗4.37K居全场第三,润滑指标略偏高,两端温升均未超判定值。清洗冷却器换热面,实测废油排出量。"
- },
- "WTG16": {
- "温升": "优秀",
- "振动": "报警",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "发电机驱动端轴承出现内圈缺陷频率及其谐波,峰值为机群中位的84.9倍、排全场第1/37(末窗因两台盲区为1/36),该线占包络谱总能量5.1%、达全场同域第90百分位的21倍,六窗全部成立,证据状态准定论·预警。优先安排振动复测、轴承座红外测温、补采脂样并判读电蚀形貌。"
- },
- "WTG17": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "温升、振动、润滑、散热四项均未超判定值。2025年4月脂样曾判超标,距今16个月,不作当前状态的判定依据;建议随全场批次补采新样以更新基线。"
- },
- "WTG18": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "良好",
- "评估结论和维护建议": "机舱湿度全场最高档。检查除湿机与舱门密封,校验湿度探头。"
- },
- "WTG19": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "已完成泵体更换,主要指标已恢复正常,单次运转时长仍略高于健康机组中位。"
- },
- "WTG20": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "报警",
- "评估结论和维护建议": "机舱湿度探头读数系统性偏低:本台月中位10.4%,全场同期为28.9%,相对全场同月中位的偏差中位为-14.6个百分点(19个月区间-21.5至-8.2个百分点)。该偏差不随季节收敛——海上机舱梅雨季与冬季的真实湿度差别很大,若读数为真,偏差应随之起伏;实测偏差月月大致相同,指向探头零点偏置而非本台确实干燥。探头读低的后果是防凝露加热在应投入时不投入,故先完成温湿度探头比对校验或更换,校准后重新判读本项。本场读数同样偏低的为20#、35#、37#三台,按同一口径一并处置。"
- },
- "WTG21": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "无异常。"
- },
- "WTG22": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "良好",
- "防凝露": "优秀",
- "评估结论和维护建议": "散热能力接近机群中位(现窗偏差+0.76K、排名15/38),2026年5月偶发过热9条、峰值143.0℃、余量12.0℃。调取2023年同类故障处置档案核实是否复发。"
- },
- "WTG23": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "报警",
- "评估结论和维护建议": "机舱湿度全场第三,加热器动作迟钝,防凝露能力最弱。检查除湿机与密封,校验探头。"
- },
- "WTG24": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "轴承更换后发电机侧目标谱族已恢复;另有换后台阶与温升再上行候选,因测点归属和同工况复核尚未闭合,当前不升级,按换后世代监视。"
- },
- "WTG25": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "报警",
- "散热": "优秀",
- "防凝露": "良好",
- "评估结论和维护建议": "单次运转时长近三月205秒、205秒、240秒持续上行,已达到200秒的升级线。实测废油量、泵出口压力,排查排油回路。"
- },
- "WTG26": {
- "温升": "报警",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "报警",
- "防凝露": "良好",
- "评估结论和维护建议": "后轴承温升近六个月中位高出机群5.6K、超出判定值的月份达5个月,同时散热偏差现窗7.35K亦居全场第一,两项第一落在同一台。轴承自投运未更换;同端振动无异常、润滑连续满转在2025年11月清理废脂后已恢复正常。委托第三方分侧振动复测并作轴承座红外测温,同步清洗冷却器换热面。证据止于候选,不储备轴承备件;风扇工况本报告无实测数据,不列为依据。"
- },
- "WTG27": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "已完成非驱动端部件更换,振动六次监测频谱无异常,温升按该端判定值复核未超标。"
- },
- "WTG28": {
- "温升": "报警",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "部件更换后前轴承温升再次上升,近六个月中位超机群5.6K;非驱动端正常。红外测温并采集脂样,与17#同批次比对。"
- },
- "WTG29": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "无异常。"
- },
- "WTG30": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "接地告警需同步核查变流器侧,发电机本体温升按该端判定值复核未超标。"
- },
- "WTG31": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "报警",
- "评估结论和维护建议": "低湿工况投入率、整窗累计加热时长、月度投入率三项均列全场第一且仍在爬升,指向温控失效。核查温控器件、湿度开关与接触器,实测工作电流。"
- },
- "WTG32": {
- "温升": "优秀",
- "振动": "良好",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "更换后仍可见内圈缺陷频率,最强一处近四次监测持续上升,按复发监视,登机时一并复测。"
- },
- "WTG33": {
- "温升": "优秀",
- "振动": "报警",
- "润滑排油": "优秀",
- "散热": "良好",
- "防凝露": "优秀",
- "评估结论和维护建议": "发电机驱动端轴承出现内圈缺陷频率及其谐波,峰值为机群中位的60.5倍,该线占包络谱总能量4.3%至6.2%、达全场同域第90百分位的13至175倍,六窗中五窗成立,证据状态准定论·预警;另散热偏差现窗4.00K居全场第四。安排振动复测、轴承座红外测温、补采脂样并判读电蚀形貌,加测轴电压与接地碳刷,并清洗冷却器换热面。"
- },
- "WTG34": {
- "温升": "良好",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "良好",
- "评估结论和维护建议": "2025年12月至2026年3月两路轴承温度通道数据对调,2026年4月已自行恢复;交换回来后与机群残差仅1.6K,在正常范围。核对该两个时点前后的接线与通道配置变更记录,不必更换探头。"
- },
- "WTG35": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "报警",
- "评估结论和维护建议": "机舱湿度探头读数系统性偏低:本台月中位10.8%,全场同期为28.9%,相对全场同月中位的偏差中位为-15.0个百分点(19个月区间-22.6至-9.8个百分点)。该偏差不随季节收敛——海上机舱梅雨季与冬季的真实湿度差别很大,若读数为真,偏差应随之起伏;实测偏差月月大致相同,指向探头零点偏置而非本台确实干燥。探头读低的后果是防凝露加热在应投入时不投入,故先完成温湿度探头比对校验或更换,校准后重新判读本项。本场读数同样偏低的为20#、35#、37#三台,按同一口径一并处置。"
- },
- "WTG36": {
- "温升": "优秀",
- "振动": "良好",
- "润滑排油": "良好",
- "散热": "优秀",
- "防凝露": "优秀",
- "评估结论和维护建议": "润滑指标已自行回落,振动信号微弱,下一次监测复核。"
- },
- "WTG37": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "优秀",
- "防凝露": "报警",
- "评估结论和维护建议": "机舱湿度探头读数系统性偏低:本台月中位9.6%,全场同期为28.9%,相对全场同月中位的偏差中位为-15.9个百分点(19个月区间-25.3至5.4个百分点)。该偏差不随季节收敛——海上机舱梅雨季与冬季的真实湿度差别很大,若读数为真,偏差应随之起伏;实测偏差月月大致相同,指向探头零点偏置而非本台确实干燥。探头读低的后果是防凝露加热在应投入时不投入,故先完成温湿度探头比对校验或更换,校准后重新判读本项。本场读数同样偏低的为20#、35#、37#三台,按同一口径一并处置。"
- },
- "WTG38": {
- "温升": "优秀",
- "振动": "优秀",
- "润滑排油": "优秀",
- "散热": "报警",
- "防凝露": "优秀",
- "评估结论和维护建议": "长期散热偏差全场第二,属慢性换热能力不足。换热器芯体清洗翻新。"
- }
- }
|